| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
SP540 single-pole, single-throw, normally open multipurpose solid-stat
Top Searches for this datasheetSP540 SP540 single-pole, single-throw, normally open multipurpose solid-state relay designed replace electromechanical relays critical applications that require fast switching solid state reliability. composed AlGaAs optically coupled Photo Diode Array that drives On-resistance Enhancement Type DMOS transistor output, providing high load current rating. APPLICATIONS High Continuous Load Current Rating (750mA) On-resistance ohms MAX) Input control power consumption (2.5mA TYP) High input-to-output isolation Long life/high reliability Reed relay replacement Meter reading systems Medical equipment Battery monitoring Multiplexers OPTIONS/SUFFIXES* ABSOLUTE MAXIMUM RATINGS* PARAMETER Storage Temperature Operating Temperature Continuous Input Current Transient Input Current Reverse Input Control Voltage Output Power Dissipation UNIT High Output Isolation Tape Reel NOTE: Suffixes listed above included marking device part number identification. SCHEMATIC DIAGRAM *The values indicated absolute stress ratings. Functional operation device implied these conditions excess those defined electrical characteristics section this document. Exposure Absolute Ratings cause permanent damage device adversely affect reliability. APPROVALS CERTIFICATE 111581-1 FILE #E90096 2004 Solid State Optronics www.ssousa.com +1.408.293.4600 Page SP540 1.40 (10/25/2004) SP540 Form Solid State Relay ELECTRICAL CHARACTERISTICS 25°C PARAMETER INPUT SPECIFICATIONS Forward Voltage Reverse Voltage Turn-On Current Turn-Off Current 10mA 10uA UNIT TEST CONDITIONS OUTPUT SPECIFICATIONS Blocking Voltage Continuous Load Current On-Resistance Leakage Current Output Capacitance Offset Voltage 750mA 25V, 1.0MHz COUPLED SPECIFICATIONS Isolation Voltage Suffix Turn-On Time Turn-Off Time Isolation Resistance Coupled Capacitance Contact Transient Ratio 2000 7000 2500 3750 minute minute 5mA, 750mA 5mA, 750mA 2004 Solid State Optronics www.ssousa.com +1.408.293.4600 Page SP540 1.40 (10/25/2004) SP540 Form Solid State Relay PERFORMANCE DATA SP540 Typical Turn-On Time Distribution 100, Ambient Temperature 25°C SP540 Typical Turn-Off Time Distribution 100, Ambient Temperature 25°C 0.45 0.55 0.65 0.75 Turn-On 0.35 0.45 0.55 0.65 Turn-Off Device Count SP540 Typical On-Resistance Distribution 100, Ambient Temperature 25°C Device Count SP540 Typical Leakage Current Distribution 100, Ambient Temperature 25°C Device Count On-Resistance (ohm Device Count 0.15 0.25 0.35 0.45 Leakage Current (uA) SP540 Typical Blocking Voltage Distribution 100, Ambient Temperature 25°C SP540 Maximum Load Current Temperature Blocking Voltage Load Current (mA) Device Count perature 2004 Solid State Optronics www.ssousa.com +1.408.293.4600 Page SP540 1.40 (10/25/2004) SP540 Form Solid State Relay MECHANICAL DIMENSIONS SINGLE IN-LINE PACKAGE VIEW SIDE VIEW 2004 Solid State Optronics www.ssousa.com +1.408.293.4600 Page SP540 1.40 (10/25/2004) SP540 Form Solid State Relay DISCLAIMER Solid State Optronics (SSO) makes warranties representations with regards completeness accuracy this document. reserves right make changes product description, specifications time without further notice. shall assume liability arising application product circuit described herein. Neither circuit patent licenses indemnity expressed implied. Except specified SSO's Standard Terms Conditions, disclaims liability consequential other damage, make other warranty, expressed implied, including merchantability fitness particular use. LIFE SUPPORT POLICY does authorize devices life support applications wherein failure malfunction device lead personal injury death. Users devices life support applications assume risks such agree indemnify against damages resulting from such use. Life support devices defined devices systems which, intended surgical implant into body, support sustain life, whose failure perform when used properly accordance with instructions reasonably expected result significant injury user, critical component component life support device system whose failure reasonably expected cause failure life support device system, affect safety effectiveness. 2004 Solid State Optronics www.ssousa.com +1.408.293.4600 Page SP540 1.40 (10/25/2004) Other recent searchesYZ101D - YZ101D YZ101D Datasheet YZ105 - YZ105 YZ105 Datasheet YZ201 - YZ201 YZ201 Datasheet YZ563YT - YZ563YT YZ563YT Datasheet WM8766 - WM8766 WM8766 Datasheet TMS320F28027 - TMS320F28027 TMS320F28027 Datasheet TMS320F28026 - TMS320F28026 TMS320F28026 Datasheet TMS320F28023 - TMS320F28023 TMS320F28023 Datasheet TMS320F28022 - TMS320F28022 TMS320F28022 Datasheet TMS320F28021 - TMS320F28021 TMS320F28021 Datasheet TMS320F28020 - TMS320F28020 TMS320F28020 Datasheet TMS320F280200 - TMS320F280200 TMS320F280200 Datasheet MIC23031 - MIC23031 MIC23031 Datasheet LT6700-1 - LT6700-1 LT6700-1 Datasheet LT6700-2 - LT6700-2 LT6700-2 Datasheet LT6700-3 - LT6700-3 LT6700-3 Datasheet IRF230 - IRF230 IRF230 Datasheet HG4508 - HG4508 HG4508 Datasheet
Privacy Policy | Disclaimer |