| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
Single triple output MEDIUM POWER AC/DC POWER SUPPLIES 80-110W AC
Top Searches for this datasheetNLP110 Medical Series Single triple output MEDIUM POWER AC/DC POWER SUPPLIES 80-110W AC/DC Universal Input Switch Mode Power Supplies Provides voltage outputs Compliance EN61000-3-2 (Power Factor 0.98) Smallest industry standard package 1.26 inches 90VAC 264VAC universal input range cUL, safety approvals CE-Marked Overvoltage short circuit protection VDE0871-A, EN55022-A, EN55011-A conducted noise VDE0871-A, EN55022-A, EN55011-A radiated noise Meets applicable relevant immunity standards EN61000-4-2,4,5 NLP110 Medical series 110W AC/DC open-frame power supplies 6.5" 1.26" package. NLP110 Medical power factor corrected meet EN61000-3-2 available single multiple output models. multiple output models have capability that unique power supply market they deliver equal amounts current multiple voltage outputs support designs that will span industry transition from logic 3.3V logic. NLP110 Medical practically same size Watt product, e.g. NLP65 Medical difference that footprint mere inches longer. NLP110 Medical series, with full medical safety approval UL2601-1, C22.2 601.1-M90, VDE0750, IEC60601-1 EN60601-1 marked, greatly accelerating design-in time reducing system compliance costs. specifications typical nominal input, full load 25°C unless otherwise stated YEAR WARRANTY SPECIFICATIONS OUTPUT SPECIFICATIONS Total regulation (Line load) Rise time Transient response Main output Auxiliary outputs turn-on Main output 100% step 0.1A/µs ±2.0% ±5.0% 1.0s, max. 5.0% 250mV max. dev., max. recovery ±0.02%/°C Main outputs Cyclic operation Single multiple 125%, ±10% Continuous table CHARACTERISTICS (continued) Surge Fast transients Radiated immunity Conducted immunity EN61000-4-5 EN61000-4-4 EN61000-4-3 EN61000-4-6 Level Level Level Level GENERAL SPECIFICATIONS Hold-up time Efficiency Isolation voltage Approvals standards Weight 120VAC, 60Hz 120VAC, (-9605) Input/output Input/chassis 16.7ms 110W min. 4000VAC 1500VAC Temperature coefficient Overvoltage protection Short circuit protection Minimum output current INPUT SPECIFICATIONS Input voltage range (See Note Input frequency range Input surge current (cold start) Safety ground leakage current Input current 120VAC 230VAC 230VAC, 50Hz 120VAC 120VAC 230VAC 230VAC 110W 110W Universal input EN60601-1, IEC60601-1,VDE0750, UL2601-1, C22.2 601.1-M90 283g (10oz) MIL-HDBK-217F 264VAC 47Hz 63Hz max. max. <100µA 0.9A 1.3A 0.48A 0.7A MTBF 25°C) 220,000 hours min. ENVIRONMENTAL SPECIFICATIONS Thermal performance Operating ambient, +50°C (See derating curve) Non-operating -40°C +85°C 50°C 70°C, ambient, Derate convection cooled load 50°C, ambient, convection cooled 50°C ambient, 110W 150LFM forced Peak (0°C +50°C, 60s) (See Note Non-condensing Operating Non-operating 500Hz MIL-STD-810E 10,000 feet max. 30,000 feet max. 2.4G peak 516.4 Part Input fuse UL/IEC127 (12) F3.15A 250VAC Relative humidity Altitude CHARACTERISTICS Conducted emissions Radiated emissions Harmonic current emission correction contact EN55022, part EN55022, part EN61000-3-2 EN61000-4-2 EN61000-4-2 Level Level Compliant Level Level Vibration (See Note Shock File Name: NLP110M.PDF Rev: 2002 NLP110 Medical Series Single triple output MEDIUM POWER AC/DC POWER SUPPLIES 80-110W AC/DC Universal Input Switch Mode Power Supplies most current data application support visit OUTPUT CURRENT PEAK OUTPUT VOLTAGE +12V +48V +24V +3.3V +12V +3.3V +2.5V +12V +12V +3.3V -12V +12V -12V Notes RIPPLE 50mV TOTAL REGULATION MODEL NUMBERS NLP110-9905 NLP110-9912 NLP110-9917 NLP110-9924 NLP110-9993 150LFM 9.2A 2.3A 4.6A 1.0A 1.0A 8.5A 1.0A 8.5A 1.0A 300LFM 9.2A 2.3A 4.6A 8.5A 8.5A 0.5A 0.3A 0.2A 0.5A 0.2A 0.5A 0.1A 0.2A 0.5A 0.2A 0.2A 6.4A 1.6A 3.2A 0.65A 0.65A 6.5A 0.65A 6.5A 0.65A 11.5A 2.5A 6.0A 1.0A 1.0A 1.0A 1.0A ±2.0% ±2.0% ±2.0% ±2.0% ±2.0% ±2.0% ±5.0% ±2.0% ±2.0% ±5.0% ±2.0% ±2.0% ±5.0% ±2.0% ±2.0% ±5.0% 120mV 240mV 240mV 50mV 50mV 120mV 50mV 50mV 120mV 1200mV 50mV 120mV 120mV 50mV 120mV NLP110-9994 NLP110-9995 NLP110-9908 Free convection. Multiple output units: maximum continuous output power exceed 80W. -9993; I3.3V max.; I5.0V max.; I3.3V I5.0V 16A. -9994; I3.3V max.; I2.5V max.; I3.3V I2.5V -9995; I3.3V max.; I12V 6.5A max.; I3.3V I12V 16A. -9908; I5.0V max.; I12V 6.5A max.; I5.0V I12V 16A. Single output units: maximum continuous output power exceed; -9905; 76.8W -9912,-9924, -9917. 150LFM forced cooling from side. Multiple output units: maximum continuous output power exceed 105W. -9993; I3.3V max.; I5.0V max.; I3.3V I5.0V 20A. -9994; I3.3V max.; I2.5V max.; I3.3V I2.5V -9995; I3.3V max.; I12V 8.5A max.; I3.3V I12V 20A. -9908; I5.0V max.; I12V 8.5A max.; I5.0V I12V 20A. Single output units: maximum continuous output power exceed 110W models. 300LFM forced cooling from side. Multiple output units: maximum continuous output power exceed 110W. -9993; I3.3V max.; I5.0V max.; I3.3V I5.0V 22A. -9994; I3.3V max.; I2.5V max.; I3.3V I2.5V -9995; I3.3V max.; I12V 8.5A max.; I3.3V I12V 22A. -9908; I5.0V max.; I12V 8.5A max.; I5.0V I12V 22A. Single output units: maximum continuous output power exceed 110W models. Peak output current lasting less than seconds with duty cycle less than During peak loading, output voltage exceed total regulation limits. Figure peak-to-peak convection power rating. Output noise measurements made across 20MHz bandwidth using twisted pair, terminated with 10µF electrolytic capacitor 0.1µF ceramic capacitor. Minimum load required correct start-up operation single outputs main output multiple versions. Failure observe minimum load main output will allow supply start-up correctly. Some electronic test loads have large delay time before they start drawing current even though voltage from supply present. During this time delay, there load output result, supply cannot start-up properly maintain correct output voltage. these instances, dummy resistive load across output necessary load output supply until test load function correctly draw intended minimum load. Minimum load required auxiliary outputs maintain regulation. models NLP110-9908 NLP110-9995, output floating. -12V output, connected Return making -12V output Three orthogonal axes, random vibration minutes each axes, 2.4G 500Hz. optimum reliability, part heatsink should exceed 110oC, semiconductor case temperature should exceed 120oC. CAUTION: Allow minimum second after disconnecting line power when making thermal measurements. This product only inclusion professional installers within other equipment must operated stand alone product. specifications reference measurements made with power supply mounted grounded metal sheet extending inch beyond each edge, using unshielded cable. external filtering required during conducted emissions testing some applications require additional filtering achieve system compliance. line choke, input cords looped twice through suppression toroid) used during radiated emissions testing. Considerable radiated testing six-sided boxes shown that units meet level typical systems. Application support available from factory assist with compliance. models require minimum mounting stand-off 6.35mm (0.25 inches) product. International Safety Standard Approvals VDE0750/IEC60601-1 EN60601-1 UL2601-1 C22.2 601.1-M90. www.artesyn.com File Name: NLP110M.PDF Rev: 2002 NLP110 Medical Series Single triple output MEDIUM POWER AC/DC POWER SUPPLIES 80-110W AC/DC Universal Input Switch Mode Power Supplies most current data application support visit Mechanical Notes dimensions inches (mm). 6.50 (165.10) 6.050 (153.670) 0.23 (5.842) 2.550 (64.770) 3.00 (76.20) (REF.) DIMENSIONS INCHES (mm) MAXIMUM COMPONENT HEIGHT 1.26 (32.00) Recommended direction forced relative power supply orientation shown below. Optimum. Very good. Good. recommended. 0.23 (5.842) INPUT CONNECTIONS Neutral Connection Line Sense Sense Safety Earth Sense Sense Input output connectors (J1) connector type Molex 26-60-4030 equivalent. OUTPUT CONNECTIONS SINGLE TRIPLE Connection Connection Connection Return Return Return Return Return Return Return Return Connection Connection Return DERATING CURVE Output Power (Watts) 110W FORCED COOLING NATURAL CONVECTION COOLING 10°C20°C30°C40°C50°C60°C 70°C Mating connectors (J1) mating connector type Molex 09-50-3031 equivalent with Molex 08-50-0105 equivalent crimp terminals. (J2) mating connector type Molex Spox type 26-03-3121 contact 08-52-0113. Sense (J3) mating connector type Molex 22-01-3027 contact 08-50-0113. Earth (J4) mating connector type Molex 90028. Sense (J5) mating connector type Leoco 2420S020000 contact 2453TPB00V1. (J2) connector type position Molex Spox type 26-48-1125 equivalent. Sense (J3) connector type Molex 22-23-2021 equivalent. Earth (J4) connector type Male 0.250 quick disconnect. Sense (J5) connector type Leoco 2421P02H000. Data Sheet Artesyn Technologies® 2002 information specifications contained this data sheet believed correct time publication. However, Artesyn Technologies accepts responsibility consequences arising from printing errors inaccuracies. Specifications subject change without notice. rights under patent accompany sale such product(s) information contained herein. www.artesyn.com File Name: NLP110M.PDF Rev: 2002 Other recent searchesTDA8177F - TDA8177F TDA8177F Datasheet STW18NK60Z - STW18NK60Z STW18NK60Z Datasheet PCA9548 - PCA9548 PCA9548 Datasheet IRFI9Z24G - IRFI9Z24G IRFI9Z24G Datasheet CRM1076NS - CRM1076NS CRM1076NS Datasheet CRM1033D - CRM1033D CRM1033D Datasheet TSP0701 - TSP0701 TSP0701 Datasheet C732J3 - C732J3 C732J3 Datasheet ATF-58143 - ATF-58143 ATF-58143 Datasheet 2N5195 - 2N5195 2N5195 Datasheet
Privacy Policy | Disclaimer |