Single triple output MEDIUM POWER AC/DC POWER SUPPLIES 80-110W AC


Datasheet Thumbnail

  

Download PDF



Top Searches for this datasheet



NLP110 Medical Series
Single triple output
MEDIUM POWER AC/DC POWER SUPPLIES 80-110W AC/DC Universal Input Switch Mode Power Supplies Provides voltage outputs Compliance EN61000-3-2 (Power Factor 0.98) Smallest industry standard package 1.26 inches 90VAC 264VAC universal input range cUL, safety approvals CE-Marked Overvoltage short circuit protection VDE0871-A, EN55022-A, EN55011-A conducted noise VDE0871-A, EN55022-A, EN55011-A radiated noise Meets applicable relevant immunity standards EN61000-4-2,4,5
NLP110 Medical series 110W AC/DC open-frame power supplies 6.5" 1.26" package. NLP110 Medical power factor corrected meet EN61000-3-2 available single multiple output models. multiple output models have capability that unique power supply market they deliver equal amounts current multiple voltage outputs support designs that will span industry transition from logic 3.3V logic. NLP110 Medical practically same size Watt product, e.g. NLP65 Medical difference that footprint mere inches longer. NLP110 Medical series, with full medical safety approval UL2601-1, C22.2 601.1-M90, VDE0750, IEC60601-1 EN60601-1 marked, greatly accelerating design-in time reducing system compliance costs.
specifications typical nominal input, full load 25°C unless otherwise stated
YEAR WARRANTY
SPECIFICATIONS
OUTPUT SPECIFICATIONS Total regulation (Line load) Rise time Transient response Main output Auxiliary outputs turn-on Main output 100% step 0.1A/µs ±2.0% ±5.0% 1.0s, max. 5.0% 250mV max. dev., max. recovery ±0.02%/°C Main outputs Cyclic operation Single multiple 125%, ±10% Continuous table
CHARACTERISTICS (continued) Surge Fast transients Radiated immunity Conducted immunity EN61000-4-5 EN61000-4-4 EN61000-4-3 EN61000-4-6 Level Level Level Level
GENERAL SPECIFICATIONS Hold-up time Efficiency Isolation voltage Approvals standards Weight 120VAC, 60Hz 120VAC, (-9605) Input/output Input/chassis 16.7ms 110W min. 4000VAC 1500VAC
Temperature coefficient Overvoltage protection Short circuit protection Minimum output current INPUT SPECIFICATIONS Input voltage range (See Note Input frequency range Input surge current (cold start) Safety ground leakage current Input current 120VAC 230VAC 230VAC, 50Hz 120VAC 120VAC 230VAC 230VAC 110W 110W Universal input
EN60601-1, IEC60601-1,VDE0750, UL2601-1, C22.2 601.1-M90 283g (10oz) MIL-HDBK-217F
264VAC 47Hz 63Hz max. max. <100µA 0.9A 1.3A 0.48A 0.7A
MTBF 25°C)
220,000 hours min.
ENVIRONMENTAL SPECIFICATIONS Thermal performance
Operating ambient, +50°C (See derating curve) Non-operating -40°C +85°C 50°C 70°C, ambient, Derate convection cooled load 50°C, ambient, convection cooled 50°C ambient, 110W 150LFM forced Peak (0°C +50°C, 60s) (See Note Non-condensing Operating Non-operating 500Hz MIL-STD-810E 10,000 feet max. 30,000 feet max. 2.4G peak 516.4 Part
Input fuse
UL/IEC127
(12)
F3.15A 250VAC
Relative humidity Altitude
CHARACTERISTICS Conducted emissions Radiated emissions Harmonic current emission correction contact
EN55022, part EN55022, part EN61000-3-2 EN61000-4-2 EN61000-4-2
Level Level Compliant Level Level
Vibration (See Note Shock
File Name: NLP110M.PDF Rev: 2002
NLP110 Medical Series
Single triple output
MEDIUM POWER AC/DC POWER SUPPLIES 80-110W AC/DC Universal Input Switch Mode Power Supplies
most current data application support visit
OUTPUT CURRENT PEAK
OUTPUT VOLTAGE +12V +48V +24V +3.3V +12V +3.3V +2.5V +12V +12V +3.3V -12V +12V -12V Notes
RIPPLE 50mV
TOTAL REGULATION
MODEL NUMBERS NLP110-9905 NLP110-9912 NLP110-9917 NLP110-9924 NLP110-9993
150LFM 9.2A 2.3A 4.6A 1.0A 1.0A 8.5A 1.0A 8.5A 1.0A
300LFM 9.2A 2.3A 4.6A 8.5A 8.5A
0.5A 0.3A 0.2A 0.5A 0.2A 0.5A 0.1A 0.2A 0.5A 0.2A 0.2A
6.4A 1.6A 3.2A 0.65A 0.65A 6.5A 0.65A 6.5A 0.65A
11.5A 2.5A 6.0A 1.0A 1.0A 1.0A 1.0A
±2.0% ±2.0% ±2.0% ±2.0% ±2.0% ±2.0% ±5.0% ±2.0% ±2.0% ±5.0% ±2.0% ±2.0% ±5.0% ±2.0% ±2.0% ±5.0%
120mV 240mV 240mV 50mV 50mV 120mV 50mV 50mV 120mV 1200mV 50mV 120mV 120mV 50mV 120mV
NLP110-9994
NLP110-9995
NLP110-9908
Free convection. Multiple output units: maximum continuous output power exceed 80W. -9993; I3.3V max.; I5.0V max.; I3.3V I5.0V 16A. -9994; I3.3V max.; I2.5V max.; I3.3V I2.5V -9995; I3.3V max.; I12V 6.5A max.; I3.3V I12V 16A. -9908; I5.0V max.; I12V 6.5A max.; I5.0V I12V 16A. Single output units: maximum continuous output power exceed; -9905; 76.8W -9912,-9924, -9917. 150LFM forced cooling from side. Multiple output units: maximum continuous output power exceed 105W. -9993; I3.3V max.; I5.0V max.; I3.3V I5.0V 20A. -9994; I3.3V max.; I2.5V max.; I3.3V I2.5V -9995; I3.3V max.; I12V 8.5A max.; I3.3V I12V 20A. -9908; I5.0V max.; I12V 8.5A max.; I5.0V I12V 20A. Single output units: maximum continuous output power exceed 110W models. 300LFM forced cooling from side. Multiple output units: maximum continuous output power exceed 110W. -9993; I3.3V max.; I5.0V max.; I3.3V I5.0V 22A. -9994; I3.3V max.; I2.5V max.; I3.3V I2.5V -9995; I3.3V max.; I12V 8.5A max.; I3.3V I12V 22A. -9908; I5.0V max.; I12V 8.5A max.; I5.0V I12V 22A. Single output units: maximum continuous output power exceed 110W models. Peak output current lasting less than seconds with duty cycle less than During peak loading, output voltage exceed total regulation limits. Figure peak-to-peak convection power rating. Output noise measurements made across 20MHz bandwidth using twisted pair, terminated with 10µF electrolytic capacitor 0.1µF ceramic capacitor.
Minimum load required correct start-up operation single outputs main output multiple versions. Failure observe minimum load main output will allow supply start-up correctly. Some electronic test loads have large delay time before they start drawing current even though voltage from supply present. During this time delay, there load output result, supply cannot start-up properly maintain correct output voltage. these instances, dummy resistive load across output necessary load output supply until test load function correctly draw intended minimum load. Minimum load required auxiliary outputs maintain regulation. models NLP110-9908 NLP110-9995, output floating. -12V output, connected Return making -12V output Three orthogonal axes, random vibration minutes each axes, 2.4G 500Hz. optimum reliability, part heatsink should exceed 110oC, semiconductor case temperature should exceed 120oC. CAUTION: Allow minimum second after disconnecting line power when making thermal measurements. This product only inclusion professional installers within other equipment must operated stand alone product. specifications reference measurements made with power supply mounted grounded metal sheet extending inch beyond each edge, using unshielded cable. external filtering required during conducted emissions testing some applications require additional filtering achieve system compliance. line choke, input cords looped twice through suppression toroid) used during radiated emissions testing. Considerable radiated testing six-sided boxes shown that units meet level typical systems. Application support available from factory assist with compliance. models require minimum mounting stand-off 6.35mm (0.25 inches) product.
International Safety Standard Approvals
VDE0750/IEC60601-1 EN60601-1 UL2601-1 C22.2 601.1-M90.
www.artesyn.com
File Name: NLP110M.PDF Rev: 2002
NLP110 Medical Series
Single triple output
MEDIUM POWER AC/DC POWER SUPPLIES 80-110W AC/DC Universal Input Switch Mode Power Supplies
most current data application support visit
Mechanical Notes
dimensions inches (mm).
6.50 (165.10) 6.050 (153.670) 0.23 (5.842)
2.550 (64.770) 3.00 (76.20)
(REF.)
DIMENSIONS INCHES (mm) MAXIMUM COMPONENT HEIGHT 1.26 (32.00)
Recommended direction forced relative power supply orientation shown below.
Optimum. Very good. Good. recommended.
0.23 (5.842)
INPUT CONNECTIONS Neutral Connection Line Sense Sense Safety Earth Sense Sense Input output connectors
(J1) connector type Molex 26-60-4030 equivalent.
OUTPUT CONNECTIONS SINGLE TRIPLE Connection Connection Connection Return Return Return Return Return Return Return Return Connection Connection Return
DERATING CURVE
Output Power (Watts)
110W
FORCED COOLING
NATURAL CONVECTION COOLING
10°C20°C30°C40°C50°C60°C 70°C
Mating connectors
(J1) mating connector type Molex 09-50-3031 equivalent with Molex 08-50-0105 equivalent crimp terminals. (J2) mating connector type Molex Spox type 26-03-3121 contact 08-52-0113. Sense (J3) mating connector type Molex 22-01-3027 contact 08-50-0113. Earth (J4) mating connector type Molex 90028. Sense (J5) mating connector type Leoco 2420S020000 contact 2453TPB00V1.
(J2) connector type position Molex Spox type 26-48-1125 equivalent. Sense (J3) connector type Molex 22-23-2021 equivalent. Earth (J4) connector type Male 0.250 quick disconnect. Sense (J5) connector type Leoco 2421P02H000.
Data Sheet Artesyn Technologies® 2002 information specifications contained this data sheet believed correct time publication. However, Artesyn Technologies accepts responsibility consequences arising from printing errors inaccuracies. Specifications subject change without notice. rights under patent accompany sale such product(s) information contained herein.
www.artesyn.com
File Name: NLP110M.PDF Rev: 2002

Other recent searches


TDA8177F - TDA8177F   TDA8177F Datasheet
STW18NK60Z - STW18NK60Z   STW18NK60Z Datasheet
PCA9548 - PCA9548   PCA9548 Datasheet
IRFI9Z24G - IRFI9Z24G   IRFI9Z24G Datasheet
CRM1076NS - CRM1076NS   CRM1076NS Datasheet
CRM1033D - CRM1033D   CRM1033D Datasheet
TSP0701 - TSP0701   TSP0701 Datasheet
C732J3 - C732J3   C732J3 Datasheet
ATF-58143 - ATF-58143   ATF-58143 Datasheet
2N5195 - 2N5195   2N5195 Datasheet

 

Privacy Policy | Disclaimer
© 2012 Datasheet Archive