| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
DC/DC CONVERTERS VOLT INPUT MHP270 SERIES WATT MODELS O
Top Searches for this datasheet-55° +100°C operation input Fully isolated Magnetic feedback Fixed frequency, typical Topology Switch, Single Ended Forward transient protection Inhibit input side output side Sync Indefinite short circuit protection Remote sense single models efficiency Parallelable: converters DC/DC CONVERTERS VOLT INPUT MHP270 SERIES WATT MODELS OUTPUT SINGLE DUAL Size (max.): 3.005 1.505 0.400 inches (76.33 38.23 10.16 "Case Maximum Dimensions" "Case Weight: grams maximum Screening: MHP270 Standard MHP270 Screening: MHP270" more information DESCRIPTION MHP270 SeriesDC/DC converters provide watts output power over full -55°C 100°C temperature range. MHP270 models operate from MIL-STD-704 nominal volt power from continuous operation with surges volts provide isolated outputs VDC. Parallel operation loading conditions supported without requirement external components. MHP270 DC/DC converters constant frequency, pulse width modulated switching power supplies which quasi-square wave, two-switch single-ended forward converter design. Tight load regulation achieved through wide-bandwidth magnetic feedback circuit. five single output converters used parallel power single load simply connecting share pins units. Units this configuration have current sharing accuracy over loading conditions. Series converters feature flexible synchronization scheme which units synchronized external clock another using sync sync pins provided each unit. converters have nominal switching frequency kHz, synchronized frequency from kHz. converters meet wide variety military/aerospace performance environmental specifications. Their continuous operation input voltage (160 400) meets normal operating limits MILSTD-704. unit shuts down above approximately volts, rated withstand surge volts msec. units built fully hermetic thick film hybrids Interpoint's MILSTD-1772 certified facilities. MHP270 Series offer complete list standard features which include: Undervoltage lock-out shuts down when input line voltage falls below approximately provide smooth initialization. Continuous short circuit protection current limit approximately 125%. Soft-start controlled start-up turn-on, release from inhibit, recovery from load fault conditions. Remote sense provide automatic compensation voltage drops output lines single output models. MHP270 SERIES WATT ABSOLUTE MAXIMUM RATINGS Input Voltage Output Power watts depending model Lead Soldering Temperature sec) 300°C Storage Temperature Range (Case) -65°C +150°C DC/DC CONVERTERS SYNC INHIBIT (INH1, INH2) Sync (525 kHz) Duty cycle min, Logic Logic high used, connect input common Referenced input common Sync Referenced input common Inhibit (INH1, INH2) Open Collector Logic (output disabled) INH1 referenced input common Logic INH2 referenced output common Logic Logic high (output enabled) Open collector TYPICAL CHARACTERISTICS Output Voltage Temperature Coefficient ppm/°C typical Isolation megohm minimum Conversion Frequency Free mode typical kHz. min., External sync range: Inhibit Voltage (unit enabled) INH1 typ., INH2 Line Drop Vout drops Input voltage Undervoltage Lockout Input voltage Current Limit 125% full load typical RECOMMENDED OPERATING CONDITIONS Input Voltage Range continuous msec transient Case Operating Temperature (Tc) +100°C full power PINS Inhibit (INH1, INH2) Sync Sync Share Sense Lines connection connection Connect input common Connect output common Must connected appropriate outputs Electrical Characteristics: 25°C Vin, 100% load, free run, unless otherwise specified. SINGLE OUTPUT MODELS PARAMETER OUTPUT VOLTAGE OUTPUT CURRENT OUTPUT POWER OUTPUT RIPPLE VOLTAGE LINE REGULATION LOAD REGULATION INPUT VOLTAGE INPUT CURRENT LOAD FULL CONTINUOUS TRANSIENT1 LOAD INHIBITED INH1 INHIBITED INH2 INPUT RIPPLE CURRENT EFFICIENCY LOAD FAULT2 POWER DISSIPATION SHORT CIRCUIT VOUT STEP LOAD RESP. 100% TRANSIENT RECOVERY3 1800 1000 CONDITION MHP27005S 4.95 5.00 5.05 MHP27012S 11.88 12.00 12.12 MHP27015S 14.85 15.00 15.15 4.33 MHP27028S 27.22 28.00 28.28 2.32 UNITS Notes Unit will shut down above approximately 425V will undamaged will restart when voltage drops into normal range. Indefinite short circuit protection guaranteed above 100°C case. Recovery time measured from application transient point which Vout within final value. DC/DC CONVERTERS DUAL OUTPUT MODELS1 PARAMETER OUTPUT VOLTAGE OUTPUT CURRENT2 OUTPUT POWER2 OUTPUT RIPPLE VOLTAGE LINE REGULATION LOAD REGULATION3 CROSS REGULATION4 INPUT VOLTAGE INPUT CURRENT CONDITIONS +VOUT -VOUT MHP27005D 4.95 5.00 5.05 4.95 5.00 5.05 MHP27012D 11.88 12.00 12.12 11.88 12.00 12.12 ±2.5 MHP270 SERIES WATT MHP27015D 14.85 15.00 15.15 14.85 15.00 15.15 ±2.16 3.46 UNITS Electrical Characteristics: 25°C Vin, 100% load, free run, unless otherwise specified. VOUT VOUT LOAD FULL VOUT EFFECT -VOUT CONTINUOUS TRANSIENT5 LOAD INHIBITED INH1 INHIBITED INH2 BALANCED LOAD POWER DISSIPATION SHORT CIRCUIT VOUT %-100% LOAD7 TRANSIENT RECOVERY8 1000 ±2.0 ±1.0 ±1.5 INPUT RIPPLE CURRENT EFFICIENCY LOAD FAULT6 STEP LOAD RESPONSE VOUT Notes Share operation characterized dual outputs. total output power (current) available from either output providing opposite output carrying power (current) use. Assumes balanced loads outputs. Effect negative output from 50%/50% loads 70%/30% 70%/30% loads. Unit will shut down above approximately 425V will undamaged will restart when voltage drops into normal range. Indefinite short circuit protection guaranteed above 125°C case. Second output Recovery time measured from application transient point which Vout within final value. SINGLE OUTPUT MODELS CONNECTION DIAGRAM SENSE Positive Input Input Common INH2 INH1 Sync Sync Share Pos. Sense Inhibit Sync Sense Return Output Common Positive Output REMOTE SENSE CONNECTION FIGURE SENSE CONNECTIONS MHP270 SERIES WATT 270V Positive Input Input Common INH2 INH1 DC/DC CONVERTERS Share Pos. Sense Sense Return Output Common Positive Output SINGLE OUTPUT MODELS CONNECTION DIAGRAM PARALLEL MHP270 Sync Sync MODEL NUMBERING Positive Input Input Common INH2 INH1 Share Pos. Sense Sense Return Output Common Positive Output Base Model Input Voltage Output Voltage Number Outputs single, dual) MHP270 Sync Sync Screening (Standard screening designator this position.) Positive Input Input Common INH2 MHP270 INH1 Sync Sync Share Sense Return Pos. Sense Output Common Positive Output FIGURE PARALLEL CONNECTIONS Single Output Positive Input Input Common Inhibit (INH2) Inhibit (INH1) Sync Sync Positive Output Output Common Sense Return Positive Sense connection Share Dual Output Positive Input Input Common Inhibit (INH2) Inhibit (INH1) Sync Sync Positive Output Output Common Negative Output connection connection Share Angled corner indicates one. VIEW (Pin side, marked side) "Case Maximum Dimensions" "Case FIGURE MHP270 This revision supercedes previous releases. technical information believed accurate, responsibility assumed errors omissions. Interpoint reserves right make changes products specifications without notice. MHP270 Series trademark Interpoint. Copyright 1994 2005 Interpoint Corporation. rights reserved. CASES CASE MAXIMUM DIMENSIONS VIEW (PIN SIDE) Angled corner indicates 1.505 (38.23) Case configuration 3.005 (76.33) max. Note: Pins shown Case Materials Header Cold Rolled Steel/Nickel/Gold Cover Kovar/Nickel Pins alloy/Gold compression glass seal Case dimensions inches (mm) Tolerance ±0.005 (0.13) three decimal places ±0.01 (0.2) decimal places unless otherwise specified CAUTION Heat from reflow wave soldering damage device. Solder pins individually with heat application exceeding 300°C seconds Case maximum dimensions, September 2005 Please refer numerical dimensions accuracy. information believed accurate, responsibility assumed errors omissions. Interpoint reserves right make changes products specifications without notice. Copyright 1999-2005 Interpoint Corp. rights reserved. CASES VIEW CASE Series, Series, Series, MFLHP Series, FMTR Series. SMFL Series, SMFLHP Series, SMHP Series, Filter, FMD270 Filter, SFCS Filter, SFME Filter, HUM70 Module, Module Angled corner indicates one. 1.505 (38.23) max. 1.380 (35.05) 1.250 (31.75) 1.050 (26.67) 0.850 (21.59) 0.650 (16.51) 0.450 (11.43) 0.250 (6.35) 0.120 (3.05) 0.000 Seam Seal 0.23 (5.8) Lead Length 0.128 (3.25). 0.040 (1.02) 0.120 (3.05) 0.250 (6.35) 2.750 (69.85) 2.880 (73.15) 3.005 (76.33) max. Seal hole: 0.100 ±0.002 (2.54 ±0.05) Case dimensions inches (mm) Tolerance ±0.005 (0.13) three decimal places ±0.01 (0.3) decimal places unless otherwise specified CAUTION Heat from reflow wave soldering damage device. Solder pins individually with heat application exceeding 300°C seconds Case September 2005 Please refer numerical dimensions accuracy. information believed accurate, responsibility assumed errors omissions. Interpoint reserves right make changes products specifications without notice. Copyright 1999-2005 Interpoint Corp. rights reserved. 0.400 (10.16) max. 0.050 (1.27) 0.000 0.000 0.220 (5.59 SCREENING: MHP270 (STANDARD MHP270 SCREENING (STANDARD TEST MHP270 STANDARD MHP270 Pre-cap Inspection Method 2017, 2032 Temperature Cycle times) Method 1010, Cond. -55°C 125°C, ambient Constant Acceleration Method 2001, Burn-In hours 100°C case, typical Final Electrical Test MIL-PRF-38534, Group Subgroups +25°C case Hermeticity Test Fine Leak, Method 1014, Cond. Gross Leak, Method 1014, Cond. Gross Leak, 10-3) Final Visual Inspection Method 2009 Test methods referenced MIL-STD-883 determined MIL-PRF-38534. MHP270 Screening Standard page Screening MHP270 Standard September 2005. This revision supercedes previous releases. technical information believed accurate, responsibility assumed errors omissions. Interpoint reserves right make changes products specifications without notice. Copyright 2005 Interpoint Corporation. rights reserved. Other recent searchesTLE42644 - TLE42644 TLE42644 Datasheet TLE214x - TLE214x TLE214x Datasheet TLE214xA - TLE214xA TLE214xA Datasheet SD103ATW - SD103ATW SD103ATW Datasheet RN1701RN1706 - RN1701RN1706 RN1701RN1706 Datasheet RN1702 - RN1702 RN1702 Datasheet RN1703 - RN1703 RN1703 Datasheet RN1704 - RN1704 RN1704 Datasheet RN1705 - RN1705 RN1705 Datasheet MAX4162 - MAX4162 MAX4162 Datasheet MAX4163 - MAX4163 MAX4163 Datasheet MAX4164 - MAX4164 MAX4164 Datasheet FDS6676 - FDS6676 FDS6676 Datasheet FCW321G - FCW321G FCW321G Datasheet AEC-Q200 - AEC-Q200 AEC-Q200 Datasheet
Privacy Policy | Disclaimer |