| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
Input Field Configurable Isolator Provides Fully Isolated Output
Top Searches for this datasheetULTRA SLIMPAK® G408-0001 G408-1001 Input Field Configurable Isolator Provides Fully Isolated Output Proportion Input Benefits Eliminates Ground Loops Field Configurable Input Ranges: 10mV 100V, 100mA Field Configurable Output Ranges: 0-5V, 0-10V, 0-1mA, 0-20mA, 4-20mA, ±5v, ±10V Ultra Slim Housing High Density Installations Flexible Power Supply Accepts 30VDC ASIC Technology Ultra SlimPak G408 rail mount, input signal conditioner with 1800VDC isolation between input, output power. field configurable input output offers flexible, wide ranging capability current voltage signals. input configured voltage ranges from 10mV 100V current ranges from 100mA (see Table output linear input either 0-5V, 0-10V, 0-1mA, 0-20mA 4-20mA (for models G408-0001) +10V (for model G408-1001). Wide ranging, precision zero span pots allow adjustability offset span turn-down within each switch selectable ranges. example, 0-2mA input range could turned down 0-1mA provide full scale output signal (e.g. 4-20mA), turned down offset achieve 1-2mA/4-20mA combination. G408 also accepts bipolar inputs (e.g. range bipolar +10V) offers selectable normal reverse operation (e.g. 4-20mA/20-4mA). ASIC based channel optically isolated 1800VDC transformer isolated from power supply. Application G408 useful eliminating ground loops, converting signal levels, providing signal drive. field configurable, wide ranging capability ensures maximum flexibility most applications, minimizing spare part requirements. Diagnostic G408 equipped with dual function signal monitor. green, front mounted indicates both power input signal status. Active power indicated illuminated LED. input signal more than 110% full scale range, will flash 8Hz. Below -10%, flash rate 4Hz. Figure G408 Block Diagram Configuration G408 input range settings. Trim potentiometers allow input zero span adjustability within each full scale input ranges. Unless otherwise specified, factory presets Model G408-0001 G408-1001 follows: G408-0001 Input Range: Output Range: Calibration After configuring switches, connect input calibrated source. Connect output actual device load load approximately equivalent device load) apply power. Note: maximize thermal stability, final calibration should performed operating installation, allowing approximately hours warm thermal equilibrium system. calibrator desired minimum input adjust zero potentiometer desired minimum output. calibrator desired maximum input adjust span potentiometer desired maximum output. Repeat steps necessary, best accuracy. 4-20mA 4-20mA G408-1001 Input Range: 4-20mA Output Range: +10V Table G408 Input Range Settings Table G408-0001 Output Settings G408-0001 Ranges 20mA Key: Closed Selector power input accepts source between 30V; typically 24VDC source used (see Accessories). minumize interference from electrical magnetic fields, shielded, twisted pair wires input output recommended. WARNING! change switch settings with power applied. Severe damage will result! Refer Tables through proper switch settings. switches select input type (voltage current) also select desired input range function setting. select desired output type. Ranges Voltage 20mV 50mV 100mV 200mV 500mV 100V Key: Closed Current 10mA 20mA 50mA 100mA Selector Table G408-1001 Output Settings G408-1001 Ranges -10V +10V Key: Closed Selector Table G408 Function Settings Function Unipolar Reverse Current Voltage Key: Closed Selector Figure G408-0001 Factory Cal; 4-20mA, Unipolar Input, Normal Operation, 4-20mA Output. Figure G408-1001 Factory Cal; 4-20mA, Unipolar Input, Normal Operation Output. Note: Ultra SlimPak modules designed operate ambient temperatures from 55°C when mounted horizontal rail. five more modules mounted vertical rail, circulating model HS01 Heat Sink recommended. Refer HS01 Technical Bulletin (#721-0549-00) contact factory assistance. Figure Wiring Diagram G408-0001 G408-1001 Figure Mounting Multiple Modules SPECIFICATIONS Input Voltage Range Limits: 10mV 100V Impedance: >100K Ohms Overvoltage: Vrms, max.(Intermittent); Vrms,max. (Continous) Current Range Limits: 100mA Impedance: Ohms, typical Overcurrent: 170mA RMS, max. Overvoltage: 60VDC Zero Turn-Up: full scale input Span Turn-Down: full scale input Common Mode (Input Ground) 1800 VDC, max. Output (G408-0001) Voltage Output: 0-5V, 0-10V Source Impedance: Ohms Drive: 10mA, max. Current Output: 0-1mA,4-20mA,0-20mA Source Impedance: >100K Ohms Compliance: 0-1mA: 7.5V, (7.5K Ohms) 4-20mA: 12V, (600 Ohms) 0-20mA: 12V, (600 Ohms) Output (G408-1001) Voltage Output: +5V, +10V Source Impedance: Ohms Drive: 10mA, max. Indication (green) Input Range >110%(approx) input:8Hz flash -10%(approx) input: flash Accuracy (Including Linearity, Hysteresis) <2mA/<20mV:± 0.35% full scale, typical; 0.5%,max. >2mA/>20mV:± 0.1% full scale, typical; 0.2%, max. Response Time (10-90%) 200mSec., typical Stability (Temperature) ±0.025% full scale/°C,typical; ±0.05%/°C, max. Common Mode Rejection 60Hz: 100dB Isolation (Input Output) 1800VDC between input, output power Compliance Mark) Emissions: EN50081-1 Immunity: EN50082-2 Safety: EN50178 Mean Time Between Failures Hours Humidity (Non-Condensing) Operating: 45°C Soak: hours 65°C Temperature Range Operating: 55°C 131°F) Storage: 70°C (-13 158°F) Wire Terminals Screw terminals 12-22AWG Power Consumption: 1.5W typical, 2.5W max. Range: 30VDC Weight lbs. Agency Approvals certified standard C22.2, 0-M91 142-M1987 (File LR42272). recognized standard UL508 (File No.E99775). Conformance directive 89/336/EEC Voltage 73/23/EEC (Input 75VDC, only). Models Accessories Ordering Information Specify: Model: G408-0001 (standard outputs) G408-1001 (bipolar outputs) Accessories: (see Accessories) Optional Custom Factory Calibration; specify C620 with desired input output range. Dimensions Accessories SlimPak series modules will mount standard TS32 (model MD02) TS35 (model MD03) rail include model HS01 heat sink. addition, following accessories available: MD03 TS35x7.5 rail WV905 24VDCPower Supply (0.5 Amp) H910 24VDC Power Supply Amp) H915 24VDC Power Supply (2.3 Amp) MB03 Bracket MD03 C664 Descriptive Tags C006 Ohm, shunt resistor Factory Assistance Eurotherm Controls additional information calibration, operation installation contact Technical Services Group: actionsupport@eurotherm.com 721-0657-00-F 09/04 Copyright© Eurotherm, 2004 741-F Miller Drive Leesburg, 20175-8993 703-443-0000 info@eurotherm.com actionio.com 703-669-1318 Action Instruments Barber-Colman Eurotherm Chessell Eurotherm Controls Other recent searchesuPD65949GJ-OSO7 - uPD65949GJ-OSO7 uPD65949GJ-OSO7 Datasheet TCO-734A - TCO-734A TCO-734A Datasheet SAA8110G - SAA8110G SAA8110G Datasheet CHM8811JPT - CHM8811JPT CHM8811JPT Datasheet BAR42FILM - BAR42FILM BAR42FILM Datasheet BAR43 - BAR43 BAR43 Datasheet SFILM - SFILM SFILM Datasheet AD9549 - AD9549 AD9549 Datasheet
Privacy Policy | Disclaimer |