| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
1300 Watts Distributed Power System Distributed Power Bulk F
Top Searches for this datasheetDS1300-3 1300 Watts Distributed Power System Distributed Power Bulk Front-End Total Output Power: 1300 Watts +12vdc Main Output; +3.3vdc Stand-by Output Wide Range Input voltage: 264VAC 264vac 1300w 264vac 910W Rev. 01.26.06 DS1300-3 Electrical Specifications Special Features Active Power Factor Correction EN61000-3-2 Harmonic Compliance Active Inrush Control Form Factor 7.5" long 13W/ +12vdc Output +3.3vdc Stand-By Plug Operation Redundant Internal OR'ing Main Stand-by Active Current Sharing Internal Cooling Fans (60mm 38mm) Communication Interface EERPOM Data Green Status, Power Amber Status, Power Failed Internal Speed Control Fail Output Signal INTEL, Std. Logic Timing INTEL, Std. Data Format shutdown <85VAC 170VAC Year Warranty Input Input range Frequency Inrush current Efficiency Conducted Radiated Power factor Leakage current Hold time 90-264 VAC, 910w vac, 1300w 47-63 single phase maximum inrush current >80% typical full load, high line Subpart EN55022 Class Subpart EN55022 Class 0.99 typical 0.75mA 240VAC 12ms minimum +12v (90VAC) 106A (180VAC) +3.3vsb Factory Set, adjustments +12vdc; ±3%; +3.3vsb; +12vdc; 130% latches overcurrent lasts over seconds, otherwise auto recovery. +3.3vsb, 105% 130% +12vdc; 13.7v +3.3vsb; 4.0v +12vdc; 11.0 11.4vdc Second <200mS, Monotonic Rise from 100% load Output Main voltage Stand-By Adjustment range Regulation Over current Over voltage Under voltage Turn-on delay +12vOutput Rise Time Share Safety UL/cUL 60950 Recognized) edition (UL)60950-1-03 NEMKO+ Report EN60950 EN60950 Mark China Test Report Logic Control PS_ON active signal that turns 12vdc power rail. When this signal High, left open, 12vdc output turn off. 3.3Vsb output remains power good signal pulled power supply indicate that outputs within regulation limits power supply. (turn-on delay 500mS) event power supply failure (OVP output, output, other electrical failure), this signal shall High state. High when Present, High Present; Pull high system. both fans have failed This shall quickly turn power supply prevent arching output contacts. Rev. 01.26.06 DS1300-3 FAIL PRESENT FAIL PS_KILL Environmental Specifications Operating temperature: Storage temperature: Altitude, operating 10,000ft. -10° 50°C power derating 70°C -40°C +85°C Electromagnetic EN61000-3-2, -3-3 susceptibility Input transients: EN61000-4-2, 4.3, 4-4, -4-5, 4-11 Level EN55024:1998 RoHS, Humidity: non-condensing Shock vibration specificatons complies with Astec Std. Specifications, Q3205 MTBF (Demonstrated) 500K full load, 50°C Anti-smoke Emission internal overload internal failures life: 70,000 40°C Ordering Information Output Main (>90VAC) Main (180VAC) Std-By Nominal Output Voltage Point 12.00vdc 12.00vdc 3.3vdc Point Tolerance ±0.2% ±0.2% Total Regulation Minimum Current 1.0A 0.5A Maximum Current 106A 7.0A Output Ripple 120mV 120mV 50mV Rev. 01.26.06 DS1300-3 AIRFLOW DIRECTION 190.5 7.5" (162.9) 65.5 2.58" 19.3 CABLE RETAINER VIEW BLACK GREEN CLIP LAIRD 771062031 0.283" 165.6 6.52" MODEL LABEL (2X) CLIP LAIRD 77-020 71.1 2.80" 143.3 5.65" (4X) CLIP LAIRD 77-020 124.45 4.90" STATUS INDICATORS INLET TYCO 1-1450330-8 51939-055 NOTE: Dimensions given inches. Power Supply Condition power power this only (includes output, over voltage, over temperature) present Standby Output Power supply outputs Power supply failure (over current) Power Supply LED's FAIL (green) (amber) Blinking Blinking Output Connector Pinout Assignment Astec Power 5810 Allen Carlsbad, 92008 Telephone: 4600 Facsimile: 0698 Technical Support: ASTEC 2752 Rev. 01.26.06 DS1300-3 Male connector viewed from rear supply Unit Power blade 51939-055 Signal Name +12V +12V RETURN (Pre-mate) +12V +12V RETURN (Pre-mate) +12V +12V RETURN (Pre-mate) +12V +12V RETURN (Pre-mate) +3V3 STAND-BY +3V3SB RETURN PS_PRESENT Power Supply Seated) (short pin) (Output Power FAIL (Failure Signal) SPARE SPARE +3V3 STAND-BY +3V3SB RETURN PSON (Power Enable Signal) PSKILL (Power Supply Fast Shutdown) (short pin) (I2C Data Signal (I2C Address Signal) FAIL (Fan Fail Signal) +3V3 STAND-BY +3V3SB RETURN Input Present) +12V SENSE +12V SENSE RETURN (I2C Address Signal) +3V3 STAND-BY SENSE Return +3V3 STAND-BY +3V3SB RETURN 12IS (+12V Current Share) SPARE (I2C Clock Signal) (I2C Address Signal) +3V3 STAND-BY SENSE Waterfront Business Park Merry Hill, Dudley West Midlands, United Kingdom Telephone: 1384 Facsimile: 1384 Units 2111-2116, Level Tower Metroplaza 223, Hing Fong Road Kwai Fong, Territories Hong Kong Telephone: +852 2437 9662 Facsimile: +852 2402 4426 Mate Mating Connector (System side) Power blade Part number 51915-023 global contact, visit: Input Connector EN60320 Type www.astecpower.com technicalsupport@astec.com While every precaution been taken ensure accuracy completeness this literature, Astec Power assumes responsibility, disclaims liability damages resulting from this information errors omissions. Printed Emerson Network Power. global leader enabling business-critical continuity. Power Connectivity Power Embedded Power Inbound Power Integrated Cabinet Solutions Outside Plant Precision Cooling Site Monitoring Services EmersonNetworkPower. Emerson Network Power Emerson Network Power logo trademarks service marks Emerson Electric ©2006 Emerson Electric Other recent searchesZX95-4795+ - ZX95-4795+ ZX95-4795+ Datasheet RT9187 - RT9187 RT9187 Datasheet MAX1437B - MAX1437B MAX1437B Datasheet G1201 - G1201 G1201 Datasheet BAT54SLT1 - BAT54SLT1 BAT54SLT1 Datasheet 1794450000 - 1794450000 1794450000 Datasheet
Privacy Policy | Disclaimer |