Frequency/Rate Meter
K3NR
High-speed, Intelligent Interface Modules with Seven Operating Modes Convert Single Dual Input Pulses Display Values
50-kHz input range 0.006% accuracy sophisticated control. wide selection outputs: relay, transistor, BCD, linear, communications. Maximum/Minimum value hold, value write protection, more. Banks with four comparative output values four prescale values. Prescale function available, which displays units actual physical parameters (length, volume, etc.). value teaching, linear output range teaching, prescale teaching available using actual measured values. Displays values hours, minutes, seconds operating mode startup compensation time parameter keeps measurement operation from sending unnecessary output preset period 99.9 Built-in sensor power supply VDC, mA). Compact size. Conforms standards, EN61010-1 (IEC61010-1). UL/CSA approved.
Model Number Structure
Model Number Legend
Base Units Output Boards ordered individually sets. Refer Output Board Combinations table page 130.
Base Units K3NR
Output Boards
Base Units with Output Boards K3NR Linear output VDC) (see note) Linear output mV/10 digits) (see note) Linear output, transistor outputs (NPN open collector) Linear output, transistor outputs (NPN open collector) Linear output, mV/10 digits+ transistor outputs (NPN open collector) Linear output, (see note) Linear output, (see note) Linear output, transistor outputs (NPN open collector) L10: Linear output, transistor outputs (NPN open collector) FLK1: Communication RS-232C (see note) FLK2: Communication RS-485 (see note) FLK3: Communication RS-422 (see note) FLK4: RS-232C transistor outputs (NPN open collector) FLK5: RS-485 transistor outputs (NPN open collector) FLK6: RS-422 transistor outputs (NPN open collector)
Input Sensors Codes inputs/Voltage pulse inputs inputs Supply Voltage Display A:Basic C:Set Value Display Output Type Codes comparative relay contact outputs PASS, SPDT) comparative relay contact outputs (HH, SPSTNO; PASS: SPDT) comparative relay contact outputs (HH, SPSTNC; PASS: SPDT) comparative transistor outputs (NPN open collector) comparative transistor outputs (PNP open collector) output (NPN open collector) (see note) output transistor outputs (NPN open collector) Linear output (see note) Note: These output types available Basic Models only.
Frequency/Rate Meter
K3NR
K-129
Panel indicators
Ordering Information
Base Unit
Input type Supply voltage NPN/Voltage pulse K3NR-NB1A K3NR-NB2A K3NR-PB1A K3NR-PB2A
Basic Models These models provide present value front-panel control keys. connected Output Board, used display only without Output Board. Value Models These models provide present value LED, value LED, front-panel control keys. connected Relay, Transistor, Combination Output Boards.
K3NR-NB1C
K3NR-NB2C
K3NR-PB1C
K3NR-PB2C
Available Output Board Combinations
Output type Output configuration Output boards Base units Basic Relay contact outputs: PASS, (SPDT) outputs: (SPST-NO), PASS (SPDT) outputs: (SPST-NC), PASS (SPDT) Transistor (see note) Linear outputs (NPN open collector) outputs (PNP open collector) 5-digit output (NPN open collector) mV/10 digits Communication boards (see note) Combination output communication boards RS-232C RS-485 RS-422 output transistor outputs (NPN open collector) transistor outputs (NPN open collector) transistor outputs (NPN open collector) mV/10 digits transistor outputs (NPN open collector) transistor outputs (NPN open collector) transistor outputs (NPN open collector) RS-232C transistor outputs (NPN open collector) RS-485 transistor outputs (NPN open collector) RS-422 transistor outputs (NPN open collector) Note: details, refer Communication Operation Manual. K31-C1 K31-C2 K31-C5 K31-T1 K31-T2 K31-B2 K31-L1 K31-L2 K31-L3 K31-L7 K31-L8 K31-FLK1 K31-FLK2 K31-FLK3 K31-B4 K31-L4 K31-L5 K31-L6 K31-L9 K31-L10 K31-FLK4 K31-FLK5 K31-FLK6 Value Display -Yes
K-130
Frequency/Rate Meter K3NR
Specifications
Ratings
Supply voltage Operating voltage range Power consumption (see note) Sensor power supply Insulation resistance Dielectric strength Noise immunity Vibration resistance Shock resistance Ambient temperature Ambient humidity (50/60 Hz); 110% supply voltage max. (max. load with indicators lit) max. (max. load with indicators lit) VDC±10% min. VDC) between external terminal case. Insulation provided between inputs, outputs, power supply. 2,000 between external terminal case. Insulation provided between inputs, outputs, power supply. ±1,500 power supply terminals normal common mode square-wave noise with Malfunction: 0.5-mm each directions Destruction: 0.75-mm each directions Malfunction: m/s2 times each directions Destruction: m/s2 times each directions Operating: Storage: Operating: -10°C 55°C (with icing) -20°C 65°C (with icing) (with condensation)
(EMI) Emission Enclosure: Emission Mains: (EMS) Immunity ESD:
EN61326+A1 Industry CISPR Group class CISRP16-1/-2 CISPR Group class CISRP16-1/-2 EN61326+A1 Industry EN61000-4-2: contact discharge (level discharge (level Immunity RF-interference: EN61000-4-3: (amplitude-modulated, GHz) (level Immunity Fast Transient Noise: EN61000-4-4: (power line) (level Immunity Burst Noise: line line (I/O signal line) Immunity Surge: EN61000-4-5: line line line ground (power line) Immunity Conducted Disturbance EN61000-4-6: (0.15 MHz) (level Immunity Voltage Dip/Interrupting EN61000-4-11: cycles, 180°, 100% (rated voltage) UL508, CSA22.2; Conforms EN61326+A1, EN61010-1 (IEC61010-1) Conforms VDE0106/P100 (finger protection) when terminal cover mounted. Approx.
Approved standards
Weight
Note: K3NR with supply voltage requires approximately control power supply current moment K3NR turned forget take this into consideration when using several K3NR units. When K3NR measuring operation (e.g., K3NR been just turned operating startup compensation time), display will read "00000" outputs will OFF.
Frequency/Rate Meter
K3NR
K-131
Panel indicators
Characteristics
Input signal No-voltage contact max., ON/OFF pulse width: min.) Voltage pulse max., ON/OFF pulse width: min., voltage: V/OFF voltage: Open collector max., ON/OFF pulse width: min.) Connectable Sensors residual voltage: max. leakage current: max. Load current: Must have switching capacity min. Must able dependably switch load current max. Operating modes ±0.006%rdg±1 digit Operating modes ±0.02%rdg±1 digit Operating mode Operating mode Operating mode Operating mode Operating mode Operating mode Operating mode 7-segment displayed automatically with negative input signal. Leading zeros displayed. Programming front-panel inputs. (0.0001 10-9 9.9999 109, decimal point freely) using prescale value teaching. Max. value (peak) hold, Min. value (bottom) hold HOLD (Process value held) RESET (Maximum/minimum data reset, counting value reset) BANK (Selection bank banks values) (Selection bank banks prescale values) Programmable with front-panel inputs 9999). Variable linear output range (for models with linear outputs only) (note Remote/Local processing (available communications output models only) Maximum/Minimum value data reset with front panel keys Comparative output pattern selection Process time averaging measured values Startup compensation time (0.0 99.9 Time unit display Security Memory power failure Relay contact output outputs) Transistor output (NPN open collector), (NPN open collector) Parallel (NPN open collector) transistor output (NPN open collector) Linear output transistor output (NPN open collector) Communication functions (RS-232C, RS-485, RS-422) Communication functions (RS-232C, RS-485, RS-422) transistor output (NPN open collector) Rotational/circumferential speed 0.0005 50,000 Absolute ratio 0.0005 50,000 Error ratio 0.0005 50,000 Rotational difference 0.0005 50,000 Flow rate ratio 0.0005 50,000 Passing time 0.0005 50,000 Pulse counting count (32-bit counter)
Measuring accuracy 23±5°C) Measuring modes ranges (Operating modes no-contact sensor models)
Max. displayed digits Display Polarity display Zero display Prescale function HOLD functions (see note External control
digits (-19999 99999)
Comparative output hysteresis setting Other functions
Output configuration
Operating modes max. Delay comparative max. outputs transistor output) Operating mode Linear output response time Operating modes max. Operating mode max. Degree protection Front panel: NEMA4X indoor (equivalent IP66) Rear case: standard IP20 Terminals: standard IP00 Non-volatile memory (EEPROM) (possible rewrite 100,000 times)
Memory protection
Note: linear output range cannot when connected mV/10-digit Linear Output Board. effective operating mode
K-132
Frequency/Rate Meter K3NR
Input/Output Ratings
Relay Contact Output
(Incorporating Relay) Item Rated load Rated carry current Max. contact voltage Max. contact current Max. switching capacity Min. permissible load level, reference value) Mechanical life Electrical life ambient temperature 23°C) Resistive load (cos VAC; max. terminal) VAC, max. terminal) 1,250 50,000,000 times min. switching frequency 18,000 times/hr) 100,000 times min. rated load switching frequency 1,800 times/hr) Inductive load (cos 0.4, VAC,
Transistor Output
Rated load voltage Max. load current Leakage current max. max.
Output
signal name Inputs REQUEST, HOLD, MAX, MIN, RESET Input signal Input current with no-voltage input Signal level Outputs DATA, POLARITY, OVERFLOW, DATA VALID, Rated load voltage Max. load current Leakage current Note: Logic method: negative logic Item voltage: max. voltage: min. max. max. Rating No-voltage contact input
Linear Output
Item Resolution Output error Permissible load resistance 4,096 ±0.5% max. min. ±1.5% min. mV/10 digits (see note)
Note: mV/10-digit output, output voltage changes every increment display value.
Communications Specifications
Item Transmission method Synchronization method Baud rate Transmission code Communications Write Read RS-232C, RS-422 4-wire, half-duplex Start-stop synchronization ASCII (7-bit) Comparative value, prescaling value, remote/local programming, reset control maximum/minimum values, other setting mode items excluding communications conditions. Process value, comparative value, maximum value, minimum value, model data, error code, others 2-wire, half-duplex Panel indicators RS-485
details, refer Communication Operation Manual.
Frequency/Rate Meter
K3NR
K-133
Connections
Terminal Arrangement
Terminal Numbers Output unit Output unit Input unit
Input unit
Note: Terminals connected internally. Terminals mutually isolated.
Input Unit
Signal input terminal
Note: Check power supply specifications model used before connecting power supply.
When inputting external control signals input signals through open collector: Transistor Inputs: Residual voltage must max. OFF: Leakage current must max. switching capacity must greater. When external signal input short-circuited, voltage approximately will applied between terminals terminal, current approximately (nominal value) will flow.
Inputs
External sensor power supply
Voltage Pulse Inputs
PNP-Inputs
External sensor power supply Input Internal circuits
Input
Internal circuits
Input
Input
Input
External sensor power supply
External sensor power supply
K3NR-NB (NPN Input/Voltage Pulse Input)
Open Collector Output (NPN Linear 2-wire Output) Contact Output Voltage Output
Input resistance:
Internal circuits
Input
K3NR-PB (PNP Input)
Open Collector Output
Contact
+12V
+12V
output sensor
Note: When contact shortcircuited, current approximately will flow voltage approximately
Voltage pulse output sensor
output sensor
Note: Connect side linear 2-wire input terminal side terminal
Note: With voltage pulse input from 3-wire sensor, connect side terminal side terminal
K-134
Frequency/Rate Meter K3NR
Output Units
K31-C1: Relay Outputs)
Outputs max. VAC) PASS
K31-C2: Relay Outputs)
Outputs max. VAC) PASS
K31-C5: Relay Outputs)
Outputs max. VAC) PASS
K31-T1: Transistor (NPN Open Collector)
Outputs max. VDC) PASS
PASS
DATA OVERFLOW DATA VALID COMMON REQUEST MAX. REQ. MIN. REQ. HOLD RESET POLARITY PASS COMMON
K31-L1, L3,-L4, -L5, -L6, -L7, -L8, -L9, -L10: Linear (Terminals provided only K31-L4, -L5, -L6, -L9, -L10.)
mV/10 digit L10:
COMMON
Outputs max. VDC) PASS
K31-FLK1: RS-232C
Note:
With K31-L4/-L5/-L6/-L9/-L10 models, terminals connected internally.
K31-FLK2, -FLK5: RS-485 (Terminals provided only K31-FLK5.)
Terminator RS-485 Outputs max. VDC) PASS
K31-FLK3, -FLK6: RS-422 (The right connector provided only K31-FLK6)
RS-422
Output max. VDC)
Terminator
K31-FLK4: RS-232C Transistor (NPN Open Collector) D-sub Connectors output (attachment) Plug: XM2A-3701 Hood: XM2S-3711 D-sub connectors RS-232C output (K31-FLK1) (order separately) Plug: XM2A-2501 Hood: XM2S-2511 D-sub connectors RS-422 output (K31-FLK3 K31FLK6) (order separately) Plug: XM2A-0901 Hood: XM2S-0911 D-sub connectors RS-232C output (K31-FLK4) (order separately) Plug: XM2D-0901 Hood: XM2D-0911
RS-232C Output max. VDC)
PASS
PASS
Frequency/Rate Meter
K3NR
K-135
Panel indicators
Block Diagram
switch Power supply sensor Sensor Sensor Input circuit Frequency measurement circuit 8-bit microcomputer
Output circuit
Control input Control input circuit
Waveform adjustment circuit Voltage stabilizing circuit Voltage stabilizing circuit Voltage stabilizing circuit
Control power supply Power supply circuit
Power supply sensor (input circuit) Frequency measurement circuit Waveform adjustment circuit 8-bit microcomputer Control input circuit
K-136
Frequency/Rate Meter K3NR
Operation
Main Functions
Output Pattern Selection c-out
patterns comparative output selectable according level change. Select pattern according application.
Startup Compensation Time stime
startup compensation time parameter keeps measurement operation from sending unnecessary output corresponding instantaneous, fluctuating input from moment K3NR turned until preset period. compensation time range from 99.9 seconds waiting time until devices subject measurement become stable after startup power supply.
Display Startup compensation time
Standard Output
value value value value
Comparative output Comparative output PASS Comparative output Comparative output
value
00000 displayed
Time
Zone Output
value value value value Comparative output Power supply
Hysteresis
Comparative output Comparative output PASS Comparative output Comparative output
hysteresis comparative outputs prevent chattering comparative outputs. Refer page more details.
Linear Output Range lset
Level Output
linear output range required. value corresponding maximum output value that corresponding minimum output value set.
value value value value
Output
20-mA output type
Comparative output Comparative output Comparative output Comparative output PASS
Lower limit
Upper limit
Display
Note: following setting conditions must satisfied, otherwise zone output will turn correctly.
Remote/Local Selection
Select remote programming when performing settings through host devices select local programming when performing settings through operation.
Process Time Averaging Measured Value
Process time averaging measured value time over which measured values will averaged. this time shorter than input pulse interval, processing will based input pulse interval.
Frequency/Rate Meter
K3NR
K-137
Panel indicators
Output Timing Chart
request signal from external device (such Programmable Controller) required read data.
Single Sampling Data Output
REQ. Max. Min. DATA data "high" Pulse with width less than more than ms.)
Data
data "high"
DATA VALID Approx.
Approximately after signal rises, sample taken DATA VALID signal output. Read data when DATA VALID signal DATA VALID signal will turn then data will OFF. Models with output have open collector output configuration that wired-OR connection possible.
REQ. Programmable controller REQ. REQ.
K3NR
K3NR
K3NR
DATA (incl. OVER) DATA VALID wired-OR processed. RUN, PASS, signals always output regardless status signal. OR-wire these signals.
DATA DATA VALID
*The period between DATA VALID signal signal should less than max.
Continuous Data Output
REQ. Max. Min. DATA data "high" Data Data
DATA VALID 40ms Approx. 64ms 24ms 40ms 64ms 24ms
K3NR outputs each measurement interval when signal continuously. HOLD signal moment DATA output switched from Data Data vice versa, output data will either Data Data according timing HOLD signal. However, output data will never below.
K-138
Frequency/Rate Meter K3NR
Example Connection Programmable Controller
K3NR (SYSMAC) Input Unit COMMON
DATA VALID
COMMON Transistor Output Boards REQUEST
Internal circuit
Internal circuit
RESET POLARITY (Polarity:
power supply
Internal circuit
Frequency/Rate Meter
K3NR
K-139
Panel indicators
Example Connection Display Unit
K3NR 1.COMMON
23.DATA VALID 24.RUN
25.COMMON 26.REQUEST 30.RESET 31.POLARITY (Polarity:
Connected
M7E-01D@N2 M7E-01H@N2
Digital Display Unit
K-140
Frequency/Rate Meter K3NR
Nomenclature
Display Status Indicators
Display Comparative Output Status Indicators Display Status Teaching Indicator
Mode
Name display display Comparative output status indicators display status Mode Functions Displays value parameter. Available Value Models only. Displays process value addition max./min. value parameter. Displays status comparative output. Indicates which comparative value currently display.
RESET/TEACH
Shift
Used return mode from Setting, Protect, Maintenance mode. process value, maximum value, minimum value displayed selected. Used enter Setting mode. Used allow display indicate values sequentially. Available Basic Models only. Used indicate values sequentially display. Available Value Models only. HOLD: MAX: MIN: PROG: when HOLD input when maximum value indicated display. when minimum value indicated display. flashes while parameters being set.
Status indicators
Teaching indicator RESET/TEACH Shift
when teaching function enabled flashes when K3NR teaching operation. maximum value, minimum value, counting values reset pressing this key. Teaching available when teaching function enabled. digit being scrolled pressing Shift Key. value increases whenever pressed.
Frequency/Rate Meter
K3NR
K-141
Panel indicators
Engineering Data
Derating Curve Sensor Power Supply
Max. current (mA)
Note: derating curve shown standard installation. derating curve depends mounting direction.
Ambient temperature (°C)
K-142
Frequency/Rate Meter K3NR
Dimensions
Note: units millimeters unless otherwise indicated.
Display
14.2
Panel Cutouts
45+0.8 92+0.8 min.
Note: K3NR uses M3.5 terminals. terminal cover provided.
min.
Frequency/Rate Meter
K3NR
K-143
Panel indicators
Precautions
!WARNING
touch terminals while power being supplied. Doing result electric shock.
Correct
Long-term
products within specified ranges. When using inside control panel, ensure that temperature around product, rather than temperature around control panel, does exceed specified temperature range. Electronic products, such this product, have lifetime that dependent lifetime internal electronic components, opposed lifetime related number relay switching operations. lifetime these components varies with temperature; higher temperature, shorter lifetime. Therefore, product lifetime extended lowering internal temperature product. When several Frequency/Rate Meters mounted close together (either horizontally vertically), internal temperature Frequency/Rate Meters rise, leading reduction lifetime. this case, take measures cool Frequency/Rate Meters, such installing fans. Ensure, however, that terminals cooled this lead incorrect measurement.
!Caution
allow metal objects conductive wire cuttings enter product. Doing result electric shock, fire, malfunction.
!Caution
attempt take product apart touch internal parts while power being supplied. Doing result electric shock.
!Caution
product locations subject flammable explosive gases. Doing result explosion.
!Caution
lifetime output relays varies greatly with switching capacity conditions. Consider actual operating conditions, relays within rated load without exceeding number operations specified rated electrical life. Using relays beyond their rated electrical life result contact deposit burning.
Operating Environment
product locations subject temperatures humidity levels above specified ranges, locations subject condensation. product locations subject severe shocks vibrations. Separate product from machines that generate high-frequency noise, such high-frequency welding machines high-frequency sewing machines. product locations subject dust corrosive gases. product outdoors locations subject direct sunlight.
!Caution
loads exceeding rated value. Doing result damage burning.
!Caution
power supply voltage within specified range. doing result damage burning.
!Caution
settings that appropriate control system. Discrepancies between settings actual control conditions result unexpected operation leading damage accidents.
Operation
When using models with comparative outputs, error occurs Frequency/Rate Meter, comparative output operate correctly. therefore recommend that consider providing alarm system separately countermeasure. Parameter settings that allow functions operate properly made, using setting menu, factory prior delivery. When using product, change settings required application.
!Caution
sure tighten terminal screws specified torque. Specified torque M3.5 screws: 0.74 0.90 Loose screws result burning malfunction.
Application Precautions
power supply voltage within specified range. doing result damage burning. sure perform wiring correctly, verifying terminal names. Incorrect wiring result burning. sure tighten screws terminal block properly. connect anything unused terminals.
Mounting
Recommended panel thickness
Panel
K-144
Frequency/Rate Meter K3NR
Attach mounting bracket left right sides Frequency/Rate Meter shown illustration above gradually tighten each screw evenly turn considering balance tightening force until ratchets start slipping without being further tightened. Mount Frequency/Rate Meter horizontally possible.
Unit Label (Provided)
product shipped with unit label attached. Select unit label from sheet provided attach Frequency/Rate Meter.
Waterproof Specifications
Products which degree protection specified models with IP@0 degree protection have waterproof specifications.
Noise Countermeasures
Separate product possible from machines that generate high-frequency noise, such high-frequency welding machines high-frequency sewing machines, machines that generate surges. Attach surge absorbers noise filters noise-generating peripheral devices particular, devices with inductance such motors, transformers, solenoids, magnet coils).
Line filter Power input K3NR Surge absorber
K3NR
order prevent inductive noise, wire lines connected terminal block separately from power lines carrying high voltages large currents. Also, wire parallel same cable power lines. There other methods that effective reducing noise, such running wires along ducts using shield lines. When using noise filter power supply, check voltage current install close Frequency/Rate Meter possible.
Inductive Noise Countermeasure Input Line
Analog Input
Signal input Two-conductor shield wire Processor
Temperature Input
Panel indicators order prevent influence induction, separate lead wire joining temperature sensor Frequency/Rate Meter from power load lines. Using product near radios, television sets, other wireless devices result reception interference.
Power input
Signal input
Frequency/Rate Meter
K3NR
K-145
Operating Procedures
Operation Mode
Reset (Enabled operating mode only.)
incremental display value reset using operations.
Display value
Bank Selection
BANK1 BANK2
Incremental value Incremental value after reset
Switch between comparative values prescaling values banks using BANK BANK signals. relationship between BANK BANK signals bank numbers shown following table. Bank number BANK BANK Comparat Prescaling value value sU1.** sU1. sU2.** sU2. sU3.** sU3. sU4.** sU4. ps1.** ps1. ps2.** ps2. ps3.** ps3. ps4.** ps4.
Reset input
RESET Press RESET/TEACH /TEACH during incremental display reset incremental value continue incremental counting operation. RESET Reset using RESET/TEACH /TEACH possible reset counting values prohibited Protect Mode.
Checking Bank Number
Press Shift min. during measurement display bank number display. (The display will return measurement value there operation seconds.)
Note: prescale value bank OFF, then prescaling value each bank fixed.
Confirming Maximum Minimum Values
Press during measurement display maximum minimum values.
Measurement value
Maximum value
Minimum value
RESET Press RESET/TEACH /TEACH while maximum minimum value displayed reset value. (This possible, however, maximum/minimum value reset prohibited Protect Mode.)
Confirming Setting Comparative Values
When measurement value, maximum value, minimum value displayed, press Mode repeatedly display comparative values order (With models that have display, comparative values displayed display.)
Measurement value Maximum value Minimum value
Comparative value
Comparative value
Comparative value
Comparative value
operation
operation
operation
operation
Note: When comparative value displayed, changed using
Shift
protection OFF).
K-146
Frequency/Rate Meter K3NR
Setting Procedures
K3NR four modes: mode normal operations, Setting mode initial parameter input, Protect mode lock-out configuration, Maintenance mode initializing values. parameters that accessible individual K3NR will vary depending Output Board installed. Refer K3NR Operation Manual details. Mode: Remains this mode under normal operation. process value max./min. value monitored. Using front panel keys, comparative value changed max./min. value counting value reset performed. Used making initial settings. Includes settings four menus (Set value (sUset prescaling (pscl setup (setup option (opt output test. sUset), pscl), setup), opt)) sUset pscl setup Used locking front operation parameter changes. Used initializing values.
Setting Mode: Protect Mode: Maintenance Mode:
Power
When power Maintenance mode
mode
Setting mode
sUset Program values s.bank Select bank values sU*.hh Enter value bank sU*. Enter value bank sU*. Enter value bank sU*. Enter value bank Note: above example when bank number pscl Display prescaling p.bank Select bank prescale values ps*.ax mantissa prescale value input ps*.ay exponent prescale value input ps*.bx mantissa prescale value input ps*.by exponent prescale value input decp.* Select decimal point decp. Note: above example when bank number setup Program operating mode/input sensor/serial communications Specify operating mode func Select sensor type input Select sensor type input =ro.ax mantissa auto zero time input =ro.ay exponent auto zero time input =ro.bx mantissa auto zero time input =ro.by exponent auto zero time input Supplementary settings related display control process time averaging measured value stime startup compensation time Select power failure memory function memo Enter hysteresis value c-out Select output pattern lset.h Enter upper limit linear output range lset.l Enter lower limit linear output range Select remote/local programming test Generating simulated input testing output function
Protect mode
prot Program lock-out configuration sUset reset mm.rst secr Enable protection Enable value change prohibition Enable prohibition counting value reset using front panel keys Enable prohibition max./min. value reset using front panel keys Specify menus protected against setting setting mode
time u-no sbit prty
Select display time unit Enter unit host Select baud rate Select word length Select stop bits Select parity bits Panel indicators
Frequency/Rate Meter
K3NR
K-147
Initial Settings
Power
Parameters
Power
Press Mode Mode.
min. move Setting
Mode Refer Operation Mode.
Press
Select setup menu with Mode operating mode, input type, other settings.
required, prescale value prescaling menu
Setting Mode
value menu
comparative values value menu
Comparative value bank
Make settings option menu
required.
operation
(See note
Comparative value operation
necessary, generate simulated input testing output function output test
(See note
Comparative value operation
After completing settings, press return Mode.
Output test
(See note
Comparative value operation
(See note
Measurement starts. Prescaling display rotational speeds, circumferential speeds, other values based input pulse calculations, rotational speed must multiplied factor input before input pulses measured. This factor called prescale value. K3NR
Proximity Sensor
Comparative value operation
Option menu
Process time averaging measured value
operation
Rotation speed (rpm) Where, Input pulse frequency (p/s) Prescale value there pulses rotation, then accurate rotation speed calculated 10-1). actual application, input follows: Mantissa 2.0000 Exponent 10-1 Auto-zero Time (Set before use.) operation modes time force-zero frequency pulse received specified period set. This time called auto-zero time. auto-zero time value that somewhat longer than longest input pulse interval. time setting long factory-set value used, display return zero even input pulse received.) Time Unit Setting Setting Meaning
prescaling menu Seconds Minutes Minutes seconds
Startup compensation time
operation
Power failure memory
operation
Hysteresis
operation
Output pattern
operation
Upper limit linear output range
operation
Selecting Sensor Type
Voltage Voltage pulse pulse
Lower limit linear output range
operation
No-contact voltage pulse input Contact input
Remote/local programming
operation
Hours, minutes, seconds
Note: time unit only operating mode (passing time) selected.
Note: there large discrepancies display select Note, however, that maximum counting frequency
K-148
Frequency/Rate Meter K3NR
Changing Values
pressing Shift while parameter displayed, value changed (setting status). PROG status indicator will flash. Change value required, press Mode register setting move next parameter.
Setting Status
Protect Mode
func
Change value using Shift
PROG flashes. there operation Next parameter seconds, setting registered parameter displayed again.
Prescaling menu
Prescale value bank (See note
operation operation
Setup menu
Operating mode
operation
(See note
Input prescale value mantissa
Input sensor type
operation
(See note
Input prescale value exponent operation operation operation
Input sensor type (See note
operation
(See note
Input prescale value mantissa (See note
Input auto-zero time mantissa
operation
Input auto-zero time exponent
operation
(See note
Input prescale value exponent (See note
Input auto-zero time mantissa (See note
operation
Decimal point operation
Input auto-zero time exponent (See note
operation
Time unit (See note
operation
Communications unit number
operation
Setting Mode, measurement stops outputs turn OFF. Depending output type model used, some parameters (indicated displayed (and hence cannot set). operating mode changed, prescale values linear output range parameters will reset their initial values. operating mode first.
Note number range more than prescale value (i.e., display measurements more than unit). These parameters will displayed (i.e., operating mode set. This parameter displayed (i.e., operating mode set. parameter other than 5cal set, prescaling menu p5cl will displayed. number range will displayed.
Baud rate
1200/2400/4800/ 9600 /19200/38400bps
operation
Word length
/8bit
operation
Stop bits
operation
Parity bits
Settings displayed reverse colors defaults.
Frequency/Rate Meter
K3NR
K-149
Panel indicators
Power Measurement stops Protect Mode.
Mode
Press
Depending output type model used, some parameters (indicated displayed (and hence cannot set).
Protect Mode
Protect menu
protection
value change prohibition
Reset prohibition
Maximum/minimum value reset prohibition
prot
(See note.)
sUset
Displayed only models with comparative outputs.
reset
mm.rst
Menus protected Setting Mode
secr
Note: Press Shift make possible change parameters.
Key-protection kpon Key-protection OFF: kpoff
Menu display
Parameter display
Meaning parameter protection: operations prohibited Mode. protection only going Protect Mode enabled.)
Setting range
Setting (See note.) change setting.
prot
Press Mode display parameter.
Setting:
kpon
kpoff
Next parameter:
sUset
Setting:
Next parameter:
reset
Press return menu.
Setting:
Next parameter:
value change prohibition: Changes comparative values prohibited Mode. (Displayed only models with comparative outputs.) kpon protection Reset prohibition: protection OFF: kpoff Resetting using front panel keys prohibited. (Resetting external signals prohibited.) Maximum/minimum value reset prohibition: Resetting maximum minimum values using front panel keys prohibited. (Resetting external signals prohibited.) Menus protected Setting Mode: Setting operations Setting Mode prohibited shown below. Setting menu value menu Prescaling menu Setup menu Option menu Setting
Mode enable setting move next parameter.
mm.rst
Setting:
Next parameter:
secr
Setting:
Next parameter:
change setting.
/1/2
Mode enable setting move next parameter.
Note: there operation seconds, setting automatically registered.
K-150
Frequency/Rate Meter K3NR
Troubleshooting
When error occurs, error details will displayed display. Take appropriate countermeasures according error displayed. Error display Error contents Comparative output m1.err (M1.ERR) Memory error m2.err (M2.ERR) m3.err (M3.ERR) Output status output (all outputs status) (all outputs status) Communications output Linear output Reset power. same error occurs, repair necessary. Reset power while holding down Key, Key, RESET/TEACH Key. settings will returned their initial values. Redo settings. same error occurs, repair necessary. Reset power. same error occurs, repair necessary. normal operation restored, possible that original error caused influence noise. Check that there sources noise vicinity. Take steps ensure that input values display values within allowable ranges. attempt change setting using operations made with remote/local selection remote, this error will flash enable settings changed, remote/local selection local. Countermeasure
err-o (ERR-O) chg-o (CHG-O)
Output error
(all outputs status)
(minimum value)
(Display value flashes.)
input range Continues display range were exceeded. Continues
Continues Continues Continues OVER signal OVER UNturns signal turns Continues Continues Continues
remote/local (RMT) (Flashes section remote.
Frequency/Rate Meter
K3NR
K-151
Panel indicators
Additional Information
Output Operation Timing Mode (Relay Transistor Outputs)
following timing chart 5-comparative Output Board when standard output pattern selected.
Operating Mode
Display Display value
value value
Hysteresis
value value
comparative output comparative output PASS output comparative output comparative output
Note: hysteresis setting mode hysteresis value will applied values.
Operating Mode
input
RESET Display
value value
Display value
value
value
comparative output comparative output PASS output comparative output comparative output
Note: Comparative output turns when measured value exceeds value.
K-152
Frequency/Rate Meter K3NR
Operating Modes
K3NR provides operating modes converting input pulses display values. mode selected operations front panel. Basically, operating modes divided into following groups.
Operating Modes
Rotational speed other displays based calculations continuous pulses (frequency).
Operating Mode
number pulses measured. Each pulse counted count maximum 99,999 counts. Decrementing count possible. Although limits display enables displaying only 99,999 counts, prescaling used count gigacounts. Operating mode Pulse counting
Example
Processing
Conveyor line
count reset shorting terminals (RESET pressing RESET/TEACH front panel Operating mode Mode Absolute ratio Error ratio Rotation difference Flow rate ratio Passing time Rotational circumferential speed display input Passing time display based input frequency processing length Rotational/Circumferential speed Because only incrementing possible, comparative outputs turn when measured values exceed values.
Mode Display calculations rotational speeds Mode
Basic Principles Rotational Speed Displays ON/OFF time sensor input other input measured with internal system clock automatically calculate frequency. This frequency multiplied displayed rotational speed.
Input sensor pulse ON/OFF time Frequency
Rotational speed (rpm) Circumferential speed Circumference Rotational speed Passing time Processing length/Circumferential speed Automatic measuring K3NR enabled simply providing input pulse.
Operating Mode Rotational/Circumferential Speed
frequency input calculated displayed rotational circumferential speed. Units: rpm; rps; rph; kHz; mm/s; m/s; m/min; km/h; l/min; l/h; etc.
Application Example
Panel indicators
Measuring Roller Winding Speed
Measuring Motor Speed (for Product Testing)
PASS Pass/fail determination
Frequency/Rate Meter
K3NR
K-153
Operating Mode Absolute Ratio
Input divided input (B/A) then multiplied display percentage. Unit:
Application Example
Measuring Ratio between Rotational Speed Rollers
Alarm PASS
Operating Mode Error Ratio
error between input input (B/A multiplied display percentage. Unit:
Application Example
Measuring Difference between Line Speeds (Two Conveyors)
Communication output (remote monitoring) computer
Operating Mode Rotational Difference
difference between input input displayed rotational speed error circumferential speed error. Units: rpm; rps; rph; kHz; mm/s; m/s; m/min; km/h; l/min; l/h; etc.
Application Example
Measuring Absolute Difference between Speeds Conveyors
Alarm PASS
Operating Mode Flow Rate Ratio
Input input used find concentration (B/(A+B)) percentage. Unit:
Application Example
Monitoring Concentration Liquid Mixture
Linear output
Recorder
K-154
Frequency/Rate Meter K3NR
Operating Mode Passing Time
pulse frequency input calculated displayed passing time preset distance. Units: min; min, min, 1/10 etc. passing time measurement operation operating mode ideal measuring time corresponding frequency change. Operating mode allows real-time, continuous time measurement revolutions rotating object without recovery time.
Application Example
Passing Time Conveyor Line
Distance
Alarm output
Operating Mode Pulse Counting
total number pulses input displayed.
Application Example
Counting Workpieces
Input Input
Hold input Reset input Display
Units: count; etc.
Note: operation comparative outputs operating mode different that other modes. Because only incrementing possible, comparative outputs turn when measured values exceed values.
Frequency/Rate Meter
K3NR
K-155
Panel indicators
DIMENSIONS SHOWN MILLIMETERS. convert millimeters into inches, multiply 0.03937. convert grams into ounces, multiply 0.03527. Cat. N087-E1-02 interest product improvement, specifications subject change without notice.
K-156
Frequency/Rate Meter K3NR

Other recent searches


VCW1127WDX - VCW1127WDX   VCW1127WDX Datasheet
STMEC001 - STMEC001   STMEC001 Datasheet
MW500-1118 - MW500-1118   MW500-1118 Datasheet
LM27212LM27213LM27292 - LM27212LM27213LM27292   LM27212LM27213LM27292 Datasheet
HA0209T - HA0209T   HA0209T Datasheet
2SC5359 - 2SC5359   2SC5359 Datasheet

 

Privacy Policy | Disclaimer
© 2012 Datasheet Archive