K3NR High-speed, Intelligent Interface Modules with Seven Operati
Top Searches for this datasheetFrequency/Rate Meter K3NR High-speed, Intelligent Interface Modules with Seven Operating Modes Convert Single Dual Input Pulses Display Values 50-kHz input range 0.006% accuracy sophisticated control. wide selection outputs: relay, transistor, BCD, linear, communications. Maximum/Minimum value hold, value write protection, more. Banks with four comparative output values four prescale values. Prescale function available, which displays units actual physical parameters (length, volume, etc.). value teaching, linear output range teaching, prescale teaching available using actual measured values. Displays values hours, minutes, seconds operating mode startup compensation time parameter keeps measurement operation from sending unnecessary output preset period 99.9 Built-in sensor power supply VDC, mA). Compact size. Conforms standards, EN61010-1 (IEC61010-1). UL/CSA approved. Model Number Structure Model Number Legend Base Units Output Boards ordered individually sets. Refer Output Board Combinations table page 130. Base Units K3NR Output Boards Base Units with Output Boards K3NR Linear output VDC) (see note) Linear output mV/10 digits) (see note) Linear output, transistor outputs (NPN open collector) Linear output, transistor outputs (NPN open collector) Linear output, mV/10 digits+ transistor outputs (NPN open collector) Linear output, (see note) Linear output, (see note) Linear output, transistor outputs (NPN open collector) L10: Linear output, transistor outputs (NPN open collector) FLK1: Communication RS-232C (see note) FLK2: Communication RS-485 (see note) FLK3: Communication RS-422 (see note) FLK4: RS-232C transistor outputs (NPN open collector) FLK5: RS-485 transistor outputs (NPN open collector) FLK6: RS-422 transistor outputs (NPN open collector) Input Sensors Codes inputs/Voltage pulse inputs inputs Supply Voltage Display A:Basic C:Set Value Display Output Type Codes comparative relay contact outputs PASS, SPDT) comparative relay contact outputs (HH, SPSTNO; PASS: SPDT) comparative relay contact outputs (HH, SPSTNC; PASS: SPDT) comparative transistor outputs (NPN open collector) comparative transistor outputs (PNP open collector) output (NPN open collector) (see note) output transistor outputs (NPN open collector) Linear output (see note) Note: These output types available Basic Models only. Frequency/Rate Meter K3NR K-129 Panel indicators Ordering Information Base Unit Input type Supply voltage NPN/Voltage pulse K3NR-NB1A K3NR-NB2A K3NR-PB1A K3NR-PB2A Basic Models These models provide present value front-panel control keys. connected Output Board, used display only without Output Board. Value Models These models provide present value LED, value LED, front-panel control keys. connected Relay, Transistor, Combination Output Boards. K3NR-NB1C K3NR-NB2C K3NR-PB1C K3NR-PB2C Available Output Board Combinations Output type Output configuration Output boards Base units Basic Relay contact outputs: PASS, (SPDT) outputs: (SPST-NO), PASS (SPDT) outputs: (SPST-NC), PASS (SPDT) Transistor (see note) Linear outputs (NPN open collector) outputs (PNP open collector) 5-digit output (NPN open collector) mV/10 digits Communication boards (see note) Combination output communication boards RS-232C RS-485 RS-422 output transistor outputs (NPN open collector) transistor outputs (NPN open collector) transistor outputs (NPN open collector) mV/10 digits transistor outputs (NPN open collector) transistor outputs (NPN open collector) transistor outputs (NPN open collector) RS-232C transistor outputs (NPN open collector) RS-485 transistor outputs (NPN open collector) RS-422 transistor outputs (NPN open collector) Note: details, refer Communication Operation Manual. K31-C1 K31-C2 K31-C5 K31-T1 K31-T2 K31-B2 K31-L1 K31-L2 K31-L3 K31-L7 K31-L8 K31-FLK1 K31-FLK2 K31-FLK3 K31-B4 K31-L4 K31-L5 K31-L6 K31-L9 K31-L10 K31-FLK4 K31-FLK5 K31-FLK6 Value Display -Yes K-130 Frequency/Rate Meter K3NR Specifications Ratings Supply voltage Operating voltage range Power consumption (see note) Sensor power supply Insulation resistance Dielectric strength Noise immunity Vibration resistance Shock resistance Ambient temperature Ambient humidity (50/60 Hz); 110% supply voltage max. (max. load with indicators lit) max. (max. load with indicators lit) VDC±10% min. VDC) between external terminal case. Insulation provided between inputs, outputs, power supply. 2,000 between external terminal case. Insulation provided between inputs, outputs, power supply. ±1,500 power supply terminals normal common mode square-wave noise with Malfunction: 0.5-mm each directions Destruction: 0.75-mm each directions Malfunction: m/s2 times each directions Destruction: m/s2 times each directions Operating: Storage: Operating: -10°C 55°C (with icing) -20°C 65°C (with icing) (with condensation) (EMI) Emission Enclosure: Emission Mains: (EMS) Immunity ESD: EN61326+A1 Industry CISPR Group class CISRP16-1/-2 CISPR Group class CISRP16-1/-2 EN61326+A1 Industry EN61000-4-2: contact discharge (level discharge (level Immunity RF-interference: EN61000-4-3: (amplitude-modulated, GHz) (level Immunity Fast Transient Noise: EN61000-4-4: (power line) (level Immunity Burst Noise: line line (I/O signal line) Immunity Surge: EN61000-4-5: line line line ground (power line) Immunity Conducted Disturbance EN61000-4-6: (0.15 MHz) (level Immunity Voltage Dip/Interrupting EN61000-4-11: cycles, 180°, 100% (rated voltage) UL508, CSA22.2; Conforms EN61326+A1, EN61010-1 (IEC61010-1) Conforms VDE0106/P100 (finger protection) when terminal cover mounted. Approx. Approved standards Weight Note: K3NR with supply voltage requires approximately control power supply current moment K3NR turned forget take this into consideration when using several K3NR units. When K3NR measuring operation (e.g., K3NR been just turned operating startup compensation time), display will read "00000" outputs will OFF. Frequency/Rate Meter K3NR K-131 Panel indicators Characteristics Input signal No-voltage contact max., ON/OFF pulse width: min.) Voltage pulse max., ON/OFF pulse width: min., voltage: V/OFF voltage: Open collector max., ON/OFF pulse width: min.) Connectable Sensors residual voltage: max. leakage current: max. Load current: Must have switching capacity min. Must able dependably switch load current max. Operating modes ±0.006%rdg±1 digit Operating modes ±0.02%rdg±1 digit Operating mode Operating mode Operating mode Operating mode Operating mode Operating mode Operating mode 7-segment displayed automatically with negative input signal. Leading zeros displayed. Programming front-panel inputs. (0.0001 10-9 9.9999 109, decimal point freely) using prescale value teaching. Max. value (peak) hold, Min. value (bottom) hold HOLD (Process value held) RESET (Maximum/minimum data reset, counting value reset) BANK (Selection bank banks values) (Selection bank banks prescale values) Programmable with front-panel inputs 9999). Variable linear output range (for models with linear outputs only) (note Remote/Local processing (available communications output models only) Maximum/Minimum value data reset with front panel keys Comparative output pattern selection Process time averaging measured values Startup compensation time (0.0 99.9 Time unit display Security Memory power failure Relay contact output outputs) Transistor output (NPN open collector), (NPN open collector) Parallel (NPN open collector) transistor output (NPN open collector) Linear output transistor output (NPN open collector) Communication functions (RS-232C, RS-485, RS-422) Communication functions (RS-232C, RS-485, RS-422) transistor output (NPN open collector) Rotational/circumferential speed 0.0005 50,000 Absolute ratio 0.0005 50,000 Error ratio 0.0005 50,000 Rotational difference 0.0005 50,000 Flow rate ratio 0.0005 50,000 Passing time 0.0005 50,000 Pulse counting count (32-bit counter) Measuring accuracy 23±5°C) Measuring modes ranges (Operating modes no-contact sensor models) Max. displayed digits Display Polarity display Zero display Prescale function HOLD functions (see note External control digits (-19999 99999) Comparative output hysteresis setting Other functions Output configuration Operating modes max. Delay comparative max. outputs transistor output) Operating mode Linear output response time Operating modes max. Operating mode max. Degree protection Front panel: NEMA4X indoor (equivalent IP66) Rear case: standard IP20 Terminals: standard IP00 Non-volatile memory (EEPROM) (possible rewrite 100,000 times) Memory protection Note: linear output range cannot when connected mV/10-digit Linear Output Board. effective operating mode K-132 Frequency/Rate Meter K3NR Input/Output Ratings Relay Contact Output (Incorporating Relay) Item Rated load Rated carry current Max. contact voltage Max. contact current Max. switching capacity Min. permissible load level, reference value) Mechanical life Electrical life ambient temperature 23°C) Resistive load (cos VAC; max. terminal) VAC, max. terminal) 1,250 50,000,000 times min. switching frequency 18,000 times/hr) 100,000 times min. rated load switching frequency 1,800 times/hr) Inductive load (cos 0.4, VAC, Transistor Output Rated load voltage Max. load current Leakage current max. max. Output signal name Inputs REQUEST, HOLD, MAX, MIN, RESET Input signal Input current with no-voltage input Signal level Outputs DATA, POLARITY, OVERFLOW, DATA VALID, Rated load voltage Max. load current Leakage current Note: Logic method: negative logic Item voltage: max. voltage: min. max. max. Rating No-voltage contact input Linear Output Item Resolution Output error Permissible load resistance 4,096 ±0.5% max. min. ±1.5% min. mV/10 digits (see note) Note: mV/10-digit output, output voltage changes every increment display value. Communications Specifications Item Transmission method Synchronization method Baud rate Transmission code Communications Write Read RS-232C, RS-422 4-wire, half-duplex Start-stop synchronization ASCII (7-bit) Comparative value, prescaling value, remote/local programming, reset control maximum/minimum values, other setting mode items excluding communications conditions. Process value, comparative value, maximum value, minimum value, model data, error code, others 2-wire, half-duplex Panel indicators RS-485 details, refer Communication Operation Manual. Frequency/Rate Meter K3NR K-133 Connections Terminal Arrangement Terminal Numbers Output unit Output unit Input unit Input unit Note: Terminals connected internally. Terminals mutually isolated. Input Unit Signal input terminal Note: Check power supply specifications model used before connecting power supply. When inputting external control signals input signals through open collector: Transistor Inputs: Residual voltage must max. OFF: Leakage current must max. switching capacity must greater. When external signal input short-circuited, voltage approximately will applied between terminals terminal, current approximately (nominal value) will flow. Inputs External sensor power supply Voltage Pulse Inputs PNP-Inputs External sensor power supply Input Internal circuits Input Internal circuits Input Input Input External sensor power supply External sensor power supply K3NR-NB (NPN Input/Voltage Pulse Input) Open Collector Output (NPN Linear 2-wire Output) Contact Output Voltage Output Input resistance: Internal circuits Input K3NR-PB (PNP Input) Open Collector Output Contact +12V +12V output sensor Note: When contact shortcircuited, current approximately will flow voltage approximately Voltage pulse output sensor output sensor Note: Connect side linear 2-wire input terminal side terminal Note: With voltage pulse input from 3-wire sensor, connect side terminal side terminal K-134 Frequency/Rate Meter K3NR Output Units K31-C1: Relay Outputs) Outputs max. VAC) PASS K31-C2: Relay Outputs) Outputs max. VAC) PASS K31-C5: Relay Outputs) Outputs max. VAC) PASS K31-T1: Transistor (NPN Open Collector) Outputs max. VDC) PASS PASS DATA OVERFLOW DATA VALID COMMON REQUEST MAX. REQ. MIN. REQ. HOLD RESET POLARITY PASS COMMON K31-L1, L3,-L4, -L5, -L6, -L7, -L8, -L9, -L10: Linear (Terminals provided only K31-L4, -L5, -L6, -L9, -L10.) mV/10 digit L10: COMMON Outputs max. VDC) PASS K31-FLK1: RS-232C Note: With K31-L4/-L5/-L6/-L9/-L10 models, terminals connected internally. K31-FLK2, -FLK5: RS-485 (Terminals provided only K31-FLK5.) Terminator RS-485 Outputs max. VDC) PASS K31-FLK3, -FLK6: RS-422 (The right connector provided only K31-FLK6) RS-422 Output max. VDC) Terminator K31-FLK4: RS-232C Transistor (NPN Open Collector) D-sub Connectors output (attachment) Plug: XM2A-3701 Hood: XM2S-3711 D-sub connectors RS-232C output (K31-FLK1) (order separately) Plug: XM2A-2501 Hood: XM2S-2511 D-sub connectors RS-422 output (K31-FLK3 K31FLK6) (order separately) Plug: XM2A-0901 Hood: XM2S-0911 D-sub connectors RS-232C output (K31-FLK4) (order separately) Plug: XM2D-0901 Hood: XM2D-0911 RS-232C Output max. VDC) PASS PASS Frequency/Rate Meter K3NR K-135 Panel indicators Block Diagram switch Power supply sensor Sensor Sensor Input circuit Frequency measurement circuit 8-bit microcomputer Output circuit Control input Control input circuit Waveform adjustment circuit Voltage stabilizing circuit Voltage stabilizing circuit Voltage stabilizing circuit Control power supply Power supply circuit Power supply sensor (input circuit) Frequency measurement circuit Waveform adjustment circuit 8-bit microcomputer Control input circuit K-136 Frequency/Rate Meter K3NR Operation Main Functions Output Pattern Selection c-out patterns comparative output selectable according level change. Select pattern according application. Startup Compensation Time stime startup compensation time parameter keeps measurement operation from sending unnecessary output corresponding instantaneous, fluctuating input from moment K3NR turned until preset period. compensation time range from 99.9 seconds waiting time until devices subject measurement become stable after startup power supply. Display Startup compensation time Standard Output value value value value Comparative output Comparative output PASS Comparative output Comparative output value 00000 displayed Time Zone Output value value value value Comparative output Power supply Hysteresis Comparative output Comparative output PASS Comparative output Comparative output hysteresis comparative outputs prevent chattering comparative outputs. Refer page more details. Linear Output Range lset Level Output linear output range required. value corresponding maximum output value that corresponding minimum output value set. value value value value Output 20-mA output type Comparative output Comparative output Comparative output Comparative output PASS Lower limit Upper limit Display Note: following setting conditions must satisfied, otherwise zone output will turn correctly. Remote/Local Selection Select remote programming when performing settings through host devices select local programming when performing settings through operation. Process Time Averaging Measured Value Process time averaging measured value time over which measured values will averaged. this time shorter than input pulse interval, processing will based input pulse interval. Frequency/Rate Meter K3NR K-137 Panel indicators Output Timing Chart request signal from external device (such Programmable Controller) required read data. Single Sampling Data Output REQ. Max. Min. DATA data "high" Pulse with width less than more than ms.) Data data "high" DATA VALID Approx. Approximately after signal rises, sample taken DATA VALID signal output. Read data when DATA VALID signal DATA VALID signal will turn then data will OFF. Models with output have open collector output configuration that wired-OR connection possible. REQ. Programmable controller REQ. REQ. K3NR K3NR K3NR DATA (incl. OVER) DATA VALID wired-OR processed. RUN, PASS, signals always output regardless status signal. OR-wire these signals. DATA DATA VALID *The period between DATA VALID signal signal should less than max. Continuous Data Output REQ. Max. Min. DATA data "high" Data Data DATA VALID 40ms Approx. 64ms 24ms 40ms 64ms 24ms K3NR outputs each measurement interval when signal continuously. HOLD signal moment DATA output switched from Data Data vice versa, output data will either Data Data according timing HOLD signal. However, output data will never below. K-138 Frequency/Rate Meter K3NR Example Connection Programmable Controller K3NR (SYSMAC) Input Unit COMMON DATA VALID COMMON Transistor Output Boards REQUEST Internal circuit Internal circuit RESET POLARITY (Polarity: power supply Internal circuit Frequency/Rate Meter K3NR K-139 Panel indicators Example Connection Display Unit K3NR 1.COMMON 23.DATA VALID 24.RUN 25.COMMON 26.REQUEST 30.RESET 31.POLARITY (Polarity: Connected M7E-01D@N2 M7E-01H@N2 Digital Display Unit K-140 Frequency/Rate Meter K3NR Nomenclature Display Status Indicators Display Comparative Output Status Indicators Display Status Teaching Indicator Mode Name display display Comparative output status indicators display status Mode Functions Displays value parameter. Available Value Models only. Displays process value addition max./min. value parameter. Displays status comparative output. Indicates which comparative value currently display. RESET/TEACH Shift Used return mode from Setting, Protect, Maintenance mode. process value, maximum value, minimum value displayed selected. Used enter Setting mode. Used allow display indicate values sequentially. Available Basic Models only. Used indicate values sequentially display. Available Value Models only. HOLD: MAX: MIN: PROG: when HOLD input when maximum value indicated display. when minimum value indicated display. flashes while parameters being set. Status indicators Teaching indicator RESET/TEACH Shift when teaching function enabled flashes when K3NR teaching operation. maximum value, minimum value, counting values reset pressing this key. Teaching available when teaching function enabled. digit being scrolled pressing Shift Key. value increases whenever pressed. Frequency/Rate Meter K3NR K-141 Panel indicators Engineering Data Derating Curve Sensor Power Supply Max. current (mA) Note: derating curve shown standard installation. derating curve depends mounting direction. Ambient temperature (°C) K-142 Frequency/Rate Meter K3NR Dimensions Note: units millimeters unless otherwise indicated. Display 14.2 Panel Cutouts 45+0.8 92+0.8 min. Note: K3NR uses M3.5 terminals. terminal cover provided. min. Frequency/Rate Meter K3NR K-143 Panel indicators Precautions !WARNING touch terminals while power being supplied. Doing result electric shock. Correct Long-term products within specified ranges. When using inside control panel, ensure that temperature around product, rather than temperature around control panel, does exceed specified temperature range. Electronic products, such this product, have lifetime that dependent lifetime internal electronic components, opposed lifetime related number relay switching operations. lifetime these components varies with temperature; higher temperature, shorter lifetime. Therefore, product lifetime extended lowering internal temperature product. When several Frequency/Rate Meters mounted close together (either horizontally vertically), internal temperature Frequency/Rate Meters rise, leading reduction lifetime. this case, take measures cool Frequency/Rate Meters, such installing fans. Ensure, however, that terminals cooled this lead incorrect measurement. !Caution allow metal objects conductive wire cuttings enter product. Doing result electric shock, fire, malfunction. !Caution attempt take product apart touch internal parts while power being supplied. Doing result electric shock. !Caution product locations subject flammable explosive gases. Doing result explosion. !Caution lifetime output relays varies greatly with switching capacity conditions. Consider actual operating conditions, relays within rated load without exceeding number operations specified rated electrical life. Using relays beyond their rated electrical life result contact deposit burning. Operating Environment product locations subject temperatures humidity levels above specified ranges, locations subject condensation. product locations subject severe shocks vibrations. Separate product from machines that generate high-frequency noise, such high-frequency welding machines high-frequency sewing machines. product locations subject dust corrosive gases. product outdoors locations subject direct sunlight. !Caution loads exceeding rated value. Doing result damage burning. !Caution power supply voltage within specified range. doing result damage burning. !Caution settings that appropriate control system. Discrepancies between settings actual control conditions result unexpected operation leading damage accidents. Operation When using models with comparative outputs, error occurs Frequency/Rate Meter, comparative output operate correctly. therefore recommend that consider providing alarm system separately countermeasure. Parameter settings that allow functions operate properly made, using setting menu, factory prior delivery. When using product, change settings required application. !Caution sure tighten terminal screws specified torque. Specified torque M3.5 screws: 0.74 0.90 Loose screws result burning malfunction. Application Precautions power supply voltage within specified range. doing result damage burning. sure perform wiring correctly, verifying terminal names. Incorrect wiring result burning. sure tighten screws terminal block properly. connect anything unused terminals. Mounting Recommended panel thickness Panel K-144 Frequency/Rate Meter K3NR Attach mounting bracket left right sides Frequency/Rate Meter shown illustration above gradually tighten each screw evenly turn considering balance tightening force until ratchets start slipping without being further tightened. Mount Frequency/Rate Meter horizontally possible. Unit Label (Provided) product shipped with unit label attached. Select unit label from sheet provided attach Frequency/Rate Meter. Waterproof Specifications Products which degree protection specified models with IP@0 degree protection have waterproof specifications. Noise Countermeasures Separate product possible from machines that generate high-frequency noise, such high-frequency welding machines high-frequency sewing machines, machines that generate surges. Attach surge absorbers noise filters noise-generating peripheral devices particular, devices with inductance such motors, transformers, solenoids, magnet coils). Line filter Power input K3NR Surge absorber K3NR order prevent inductive noise, wire lines connected terminal block separately from power lines carrying high voltages large currents. Also, wire parallel same cable power lines. There other methods that effective reducing noise, such running wires along ducts using shield lines. When using noise filter power supply, check voltage current install close Frequency/Rate Meter possible. Inductive Noise Countermeasure Input Line Analog Input Signal input Two-conductor shield wire Processor Temperature Input Panel indicators order prevent influence induction, separate lead wire joining temperature sensor Frequency/Rate Meter from power load lines. Using product near radios, television sets, other wireless devices result reception interference. Power input Signal input Frequency/Rate Meter K3NR K-145 Operating Procedures Operation Mode Reset (Enabled operating mode only.) incremental display value reset using operations. Display value Bank Selection BANK1 BANK2 Incremental value Incremental value after reset Switch between comparative values prescaling values banks using BANK BANK signals. relationship between BANK BANK signals bank numbers shown following table. Bank number BANK BANK Comparat Prescaling value value sU1.** sU1. sU2.** sU2. sU3.** sU3. sU4.** sU4. ps1.** ps1. ps2.** ps2. ps3.** ps3. ps4.** ps4. Reset input RESET Press RESET/TEACH /TEACH during incremental display reset incremental value continue incremental counting operation. RESET Reset using RESET/TEACH /TEACH possible reset counting values prohibited Protect Mode. Checking Bank Number Press Shift min. during measurement display bank number display. (The display will return measurement value there operation seconds.) Note: prescale value bank OFF, then prescaling value each bank fixed. Confirming Maximum Minimum Values Press during measurement display maximum minimum values. Measurement value Maximum value Minimum value RESET Press RESET/TEACH /TEACH while maximum minimum value displayed reset value. (This possible, however, maximum/minimum value reset prohibited Protect Mode.) Confirming Setting Comparative Values When measurement value, maximum value, minimum value displayed, press Mode repeatedly display comparative values order (With models that have display, comparative values displayed display.) Measurement value Maximum value Minimum value Comparative value Comparative value Comparative value Comparative value operation operation operation operation Note: When comparative value displayed, changed using Shift protection OFF). K-146 Frequency/Rate Meter K3NR Setting Procedures K3NR four modes: mode normal operations, Setting mode initial parameter input, Protect mode lock-out configuration, Maintenance mode initializing values. parameters that accessible individual K3NR will vary depending Output Board installed. Refer K3NR Operation Manual details. Mode: Remains this mode under normal operation. process value max./min. value monitored. Using front panel keys, comparative value changed max./min. value counting value reset performed. Used making initial settings. Includes settings four menus (Set value (sUset prescaling (pscl setup (setup option (opt output test. sUset), pscl), setup), opt)) sUset pscl setup Used locking front operation parameter changes. Used initializing values. Setting Mode: Protect Mode: Maintenance Mode: Power When power Maintenance mode mode Setting mode sUset Program values s.bank Select bank values sU*.hh Enter value bank sU*. Enter value bank sU*. Enter value bank sU*. Enter value bank Note: above example when bank number pscl Display prescaling p.bank Select bank prescale values ps*.ax mantissa prescale value input ps*.ay exponent prescale value input ps*.bx mantissa prescale value input ps*.by exponent prescale value input decp.* Select decimal point decp. Note: above example when bank number setup Program operating mode/input sensor/serial communications Specify operating mode func Select sensor type input Select sensor type input =ro.ax mantissa auto zero time input =ro.ay exponent auto zero time input =ro.bx mantissa auto zero time input =ro.by exponent auto zero time input Supplementary settings related display control process time averaging measured value stime startup compensation time Select power failure memory function memo Enter hysteresis value c-out Select output pattern lset.h Enter upper limit linear output range lset.l Enter lower limit linear output range Select remote/local programming test Generating simulated input testing output function Protect mode prot Program lock-out configuration sUset reset mm.rst secr Enable protection Enable value change prohibition Enable prohibition counting value reset using front panel keys Enable prohibition max./min. value reset using front panel keys Specify menus protected against setting setting mode time u-no sbit prty Select display time unit Enter unit host Select baud rate Select word length Select stop bits Select parity bits Panel indicators Frequency/Rate Meter K3NR K-147 Initial Settings Power Parameters Power Press Mode Mode. min. move Setting Mode Refer Operation Mode. Press Select setup menu with Mode operating mode, input type, other settings. required, prescale value prescaling menu Setting Mode value menu comparative values value menu Comparative value bank Make settings option menu required. operation (See note Comparative value operation necessary, generate simulated input testing output function output test (See note Comparative value operation After completing settings, press return Mode. Output test (See note Comparative value operation (See note Measurement starts. Prescaling display rotational speeds, circumferential speeds, other values based input pulse calculations, rotational speed must multiplied factor input before input pulses measured. This factor called prescale value. K3NR Proximity Sensor Comparative value operation Option menu Process time averaging measured value operation Rotation speed (rpm) Where, Input pulse frequency (p/s) Prescale value there pulses rotation, then accurate rotation speed calculated 10-1). actual application, input follows: Mantissa 2.0000 Exponent 10-1 Auto-zero Time (Set before use.) operation modes time force-zero frequency pulse received specified period set. This time called auto-zero time. auto-zero time value that somewhat longer than longest input pulse interval. time setting long factory-set value used, display return zero even input pulse received.) Time Unit Setting Setting Meaning prescaling menu Seconds Minutes Minutes seconds Startup compensation time operation Power failure memory operation Hysteresis operation Output pattern operation Upper limit linear output range operation Selecting Sensor Type Voltage Voltage pulse pulse Lower limit linear output range operation No-contact voltage pulse input Contact input Remote/local programming operation Hours, minutes, seconds Note: time unit only operating mode (passing time) selected. Note: there large discrepancies display select Note, however, that maximum counting frequency K-148 Frequency/Rate Meter K3NR Changing Values pressing Shift while parameter displayed, value changed (setting status). PROG status indicator will flash. Change value required, press Mode register setting move next parameter. Setting Status Protect Mode func Change value using Shift PROG flashes. there operation Next parameter seconds, setting registered parameter displayed again. Prescaling menu Prescale value bank (See note operation operation Setup menu Operating mode operation (See note Input prescale value mantissa Input sensor type operation (See note Input prescale value exponent operation operation operation Input sensor type (See note operation (See note Input prescale value mantissa (See note Input auto-zero time mantissa operation Input auto-zero time exponent operation (See note Input prescale value exponent (See note Input auto-zero time mantissa (See note operation Decimal point operation Input auto-zero time exponent (See note operation Time unit (See note operation Communications unit number operation Setting Mode, measurement stops outputs turn OFF. Depending output type model used, some parameters (indicated displayed (and hence cannot set). operating mode changed, prescale values linear output range parameters will reset their initial values. operating mode first. Note number range more than prescale value (i.e., display measurements more than unit). These parameters will displayed (i.e., operating mode set. This parameter displayed (i.e., operating mode set. parameter other than 5cal set, prescaling menu p5cl will displayed. number range will displayed. Baud rate 1200/2400/4800/ 9600 /19200/38400bps operation Word length /8bit operation Stop bits operation Parity bits Settings displayed reverse colors defaults. Frequency/Rate Meter K3NR K-149 Panel indicators Power Measurement stops Protect Mode. Mode Press Depending output type model used, some parameters (indicated displayed (and hence cannot set). Protect Mode Protect menu protection value change prohibition Reset prohibition Maximum/minimum value reset prohibition prot (See note.) sUset Displayed only models with comparative outputs. reset mm.rst Menus protected Setting Mode secr Note: Press Shift make possible change parameters. Key-protection kpon Key-protection OFF: kpoff Menu display Parameter display Meaning parameter protection: operations prohibited Mode. protection only going Protect Mode enabled.) Setting range Setting (See note.) change setting. prot Press Mode display parameter. Setting: kpon kpoff Next parameter: sUset Setting: Next parameter: reset Press return menu. Setting: Next parameter: value change prohibition: Changes comparative values prohibited Mode. (Displayed only models with comparative outputs.) kpon protection Reset prohibition: protection OFF: kpoff Resetting using front panel keys prohibited. (Resetting external signals prohibited.) Maximum/minimum value reset prohibition: Resetting maximum minimum values using front panel keys prohibited. (Resetting external signals prohibited.) Menus protected Setting Mode: Setting operations Setting Mode prohibited shown below. Setting menu value menu Prescaling menu Setup menu Option menu Setting Mode enable setting move next parameter. mm.rst Setting: Next parameter: secr Setting: Next parameter: change setting. /1/2 Mode enable setting move next parameter. Note: there operation seconds, setting automatically registered. K-150 Frequency/Rate Meter K3NR Troubleshooting When error occurs, error details will displayed display. Take appropriate countermeasures according error displayed. Error display Error contents Comparative output m1.err (M1.ERR) Memory error m2.err (M2.ERR) m3.err (M3.ERR) Output status output (all outputs status) (all outputs status) Communications output Linear output Reset power. same error occurs, repair necessary. Reset power while holding down Key, Key, RESET/TEACH Key. settings will returned their initial values. Redo settings. same error occurs, repair necessary. Reset power. same error occurs, repair necessary. normal operation restored, possible that original error caused influence noise. Check that there sources noise vicinity. Take steps ensure that input values display values within allowable ranges. attempt change setting using operations made with remote/local selection remote, this error will flash enable settings changed, remote/local selection local. Countermeasure err-o (ERR-O) chg-o (CHG-O) Output error (all outputs status) (minimum value) (Display value flashes.) input range Continues display range were exceeded. Continues Continues Continues Continues OVER signal OVER UNturns signal turns Continues Continues Continues remote/local (RMT) (Flashes section remote. Frequency/Rate Meter K3NR K-151 Panel indicators Additional Information Output Operation Timing Mode (Relay Transistor Outputs) following timing chart 5-comparative Output Board when standard output pattern selected. Operating Mode Display Display value value value Hysteresis value value comparative output comparative output PASS output comparative output comparative output Note: hysteresis setting mode hysteresis value will applied values. Operating Mode input RESET Display value value Display value value value comparative output comparative output PASS output comparative output comparative output Note: Comparative output turns when measured value exceeds value. K-152 Frequency/Rate Meter K3NR Operating Modes K3NR provides operating modes converting input pulses display values. mode selected operations front panel. Basically, operating modes divided into following groups. Operating Modes Rotational speed other displays based calculations continuous pulses (frequency). Operating Mode number pulses measured. Each pulse counted count maximum 99,999 counts. Decrementing count possible. Although limits display enables displaying only 99,999 counts, prescaling used count gigacounts. Operating mode Pulse counting Example Processing Conveyor line count reset shorting terminals (RESET pressing RESET/TEACH front panel Operating mode Mode Absolute ratio Error ratio Rotation difference Flow rate ratio Passing time Rotational circumferential speed display input Passing time display based input frequency processing length Rotational/Circumferential speed Because only incrementing possible, comparative outputs turn when measured values exceed values. Mode Display calculations rotational speeds Mode Basic Principles Rotational Speed Displays ON/OFF time sensor input other input measured with internal system clock automatically calculate frequency. This frequency multiplied displayed rotational speed. Input sensor pulse ON/OFF time Frequency Rotational speed (rpm) Circumferential speed Circumference Rotational speed Passing time Processing length/Circumferential speed Automatic measuring K3NR enabled simply providing input pulse. Operating Mode Rotational/Circumferential Speed frequency input calculated displayed rotational circumferential speed. Units: rpm; rps; rph; kHz; mm/s; m/s; m/min; km/h; l/min; l/h; etc. Application Example Panel indicators Measuring Roller Winding Speed Measuring Motor Speed (for Product Testing) PASS Pass/fail determination Frequency/Rate Meter K3NR K-153 Operating Mode Absolute Ratio Input divided input (B/A) then multiplied display percentage. Unit: Application Example Measuring Ratio between Rotational Speed Rollers Alarm PASS Operating Mode Error Ratio error between input input (B/A multiplied display percentage. Unit: Application Example Measuring Difference between Line Speeds (Two Conveyors) Communication output (remote monitoring) computer Operating Mode Rotational Difference difference between input input displayed rotational speed error circumferential speed error. Units: rpm; rps; rph; kHz; mm/s; m/s; m/min; km/h; l/min; l/h; etc. Application Example Measuring Absolute Difference between Speeds Conveyors Alarm PASS Operating Mode Flow Rate Ratio Input input used find concentration (B/(A+B)) percentage. Unit: Application Example Monitoring Concentration Liquid Mixture Linear output Recorder K-154 Frequency/Rate Meter K3NR Operating Mode Passing Time pulse frequency input calculated displayed passing time preset distance. Units: min; min, min, 1/10 etc. passing time measurement operation operating mode ideal measuring time corresponding frequency change. Operating mode allows real-time, continuous time measurement revolutions rotating object without recovery time. Application Example Passing Time Conveyor Line Distance Alarm output Operating Mode Pulse Counting total number pulses input displayed. Application Example Counting Workpieces Input Input Hold input Reset input Display Units: count; etc. Note: operation comparative outputs operating mode different that other modes. Because only incrementing possible, comparative outputs turn when measured values exceed values. Frequency/Rate Meter K3NR K-155 Panel indicators DIMENSIONS SHOWN MILLIMETERS. convert millimeters into inches, multiply 0.03937. convert grams into ounces, multiply 0.03527. Cat. N087-E1-02 interest product improvement, specifications subject change without notice. K-156 Frequency/Rate Meter K3NR Other recent searchesVCW1127WDX - VCW1127WDX VCW1127WDX Datasheet STMEC001 - STMEC001 STMEC001 Datasheet MW500-1118 - MW500-1118 MW500-1118 Datasheet LM27212LM27213LM27292 - LM27212LM27213LM27292 LM27212LM27213LM27292 Datasheet HA0209T - HA0209T HA0209T Datasheet 2SC5359 - 2SC5359 2SC5359 Datasheet
Privacy Policy | Disclaimer |