MEMBRAPOR
SPECIFICATION SHEET FOR FOR H2 SENSOR TYPE H2 / CA-1000
MEMBRAPOR
SPECIFICATION SHEET FOR FOR H2 SENSOR TYPE H2 / CA-1000
PERFORMANCE CHARACTERISTICS Nominal Range Maximum Overload Expected Operation Life Output Signal Resolution Temperature Range Pressure Range Pressure Coefficient T90 Response Time Relative Humidity Range Typical Baseline Range (pure air, 20°C) Maximum Zero Shift (+20°C to +40°C) Long Term Output Drift Recommended Load Resistor Bias Voltage Repeatability Output Linearity
PHYSICAL CHARACTERISTICS Weight Position Sensitivity Storage Life Recommended Storage Temperature Warranty Period ~ 13 g None Six months in container 5 °C - 20 °C 12 months from date of dispatch
Compact-Size Outline Dimensions BOTTOM VIEW 45° Reference 45° Sensing Counter
17.0 mm PCD Nonconnected Pin 24 mm
CROSS-SENSITIVITY DATA Interfering Gas Concentration CO
SIDE VIEW
27.1 mm O-Ring 23.7 mm
100 ppm
for temperature 20 °C
3.5 mm Pin Projection
APPLICATIONS H2 Detection in H2 / CO-Mixtures Medical Applications Safety and Environmental Control Note: The sensor must be operated by using a suitable gas ket for gas flow exposure
1 mm Pins on 17.0 mm PCD
The data contained in this document is for guidance only. Membrapor AG accepts no liability for any consequential losses, injury or damage resulting from the use of this document or the information contained within it. The data is given for guidance only. Customers should test under their own conditions, to ensure that the sensors are suitable for their own requirements.
REV.: 6 / 2004 Phone: +41 43 311 72 00 Fax : +41 43 311 72 01 Email: info@membrapor.ch www.membrapor.ch
|