FM-RCHN-XXXRS COMPLETE REMOTE CONTROL SYSTEM IP64 RATED ENCLOSURE


Datasheet Thumbnail

  

Download PDF



Top Searches for this datasheet



REMOTE CONTROL SYSTEM.
FM-RCHN-XXXRS
COMPLETE REMOTE CONTROL SYSTEM IP64 RATED ENCLOSURE. MINIMAL INSTALLATION SCREW TERMINALS. 240Vac 12Vdc SUPPLY. CHANNELS. INDICATION TRANSMISSION. INDICATION EACH OUTPUT CHANNEL. MOMENTARY TOGGLED OUTPUTS PROGRAMMABLE TIMED OUTPUTS (10secs-5mins). RELAY CONTACTS 240Vac. REQUIRES RADIO LICENCE. RANGE METRES HIGH SECURITY PROTOCOL. IP64 RATED ENCLOSURE USED WITH FM-ECA AUTO
DESCRIPTION
FM-RCHn-XXXRS complete remote control system supplied ready operate. Installation requires connections made only power supply which 240Vac 12Vdc. Available options channels. provides rated relays 240Vac with either momentary latching operation. system incorporates highly secure `code hopping' transmission protocol prevent grabbing scanning data. outputs programmed operate latching momentary mode. (there maximum latching three momentary outputs). timed output feature also available output four. system range metres direct line sight, requires minimal installation. decoder easy learn feature which enables learn `signature code' individual transmitter/encoders switches.(These memorised even power removed). decoder also used conjunction with FM-ECAC auto transmitting encoder. Stock code 226-3398) system supplied ready operate with remote transmitter/encoder. decoder supplied IP64 rated enclosure.
BLOCK DIAGRAM
TRANSMITTER ENCODER
RECEIVER DECODER (RLY (RLY (RLY
SUPPLY 240Vac
RELAY OUTPUTS (COM,
DS000032
July
©1999 4001, ENGLAND.
Page
REMOTE CONTROL SYSTEM.
DECODER CONNECTIONS
FM-RCHN-XXXRS
Decoder Module (FM-DH0)
LINKS
decoder requires either single 12Vdc supply 240Vac mains.
WARNING
This appliance connected mains. unit design fixed installation which connected mains supply. Before removing cover, ensure that mains input supply removed. operation product that involves removal front cover should only carried competent person qualified electrician.
DATA OUTPUTS
Output variable timed output which maybe adjusted from 10secs minutes. This controlled adjustable RV1. Outputs configured momentary latching operation link FM-DH0-418 decoder module. standard remote Control system Link MUST fitted.
DECODER LINKS
These links configure mode operation. Configuration Remote Control Remote Control with FM-ECAC Auto Transmitting Encoder Note Link Connected Connected Open Link Open Connected Don't Care O/P1 Latch Auto O/P2 Latch O/P3 Battery O/P4 Timed Timed Trig I/P's
Link status read only power after changing links please remember remove re-apply power.
DS000032
July
©1999 4001, ENGLAND.
Page
REMOTE CONTROL SYSTEM.
LEARNING TRANSMITTER SWITCH
FM-RCHN-XXXRS
These decoders capable `learning' transmitter/Encoder signature code, individual switch number. decoder allocates specific transmitter/encoder's switch, against chosen decoder output. decoder maximum memory capacity learning eight unique encoder switches. These from single many different encoders allocated single output combination outputs decoder. learn transmitter switch follow these procedures; Firstly determine which switch encoder which output channel decoder wish allocate each other. order select appropriate decoder output channel, user must step through outputs until desired channel selected (these through Each time decoders programming switch briefly pressed released, will flash number times indicate which channel currently selected. desired channel overstepped missed, simply wait seconds decoder will start from channel again, step right through outputs, decoder will automatically return channel Note that after flashing times select channel decoder flashes times. This normal detailed below "Erase memory" section. enter "Programming mode" user must hold down programming switch whilst desired channel (indicated appropriate number flashes) currently selected. After flashing required number flashes, will approx. seconds then illuminate. decoder learn mode. (Keep programming switch depressed) Depress transmitter once, decoder will flash. (PSW still depressed). Wait stop flashing. Depress transmitter again, will turn off. (PSW still depressed). Release programming switch (PSW). decoder learnt encoder switch will operate system. Note: teach same switch more than output same decoder!
ERASING DECODER'S MEMORY
completely erase FM-ECAC signature code form FM-DH0 decoder's memory; Press FM-DH0 decoder briefly. (The will flash once). Press FM-DH0 decoder again briefly. (The will flash twice). Press FM-DH0 decoder again briefly. (The will flash three times). Press FM-DH0 decoder again briefly. (The will flash four times). Press FM-DH0 decoder hold. (The will flash nine times, several seconds then illuminate again. FM-DH0 decoder switch released. (When goes out, FM-DH0 decoder memory erased)
SYNCHRONISATION (Hopping Models only)
This equipment requires transmitter receiver synchronised. transmitter been pressed more than times outside range receiver, receiver will loose synchronisation with transmitter. re-synchronise: Press transmitter seconds within range receiver, Release momentarily, press again.
DS000032
July
©1999 4001, ENGLAND.
Page
REMOTE CONTROL SYSTEM.
TECHNICAL SPECIFICATIONS Dimension Length Width Depth
Storage Temperature; +70o Celsius. Operating Temperature; +55o Celsius.
FM-RCHN-XXXRS
Transmitter 107mm 60mm 22mm
Decoder Enclosure 112mm 83mm 38mm
TRANSMITTER/ENCODER ELECTRICAL CHARACTERISTICS Supply Voltage Supply Current Quiescent Supply Current Operating RECEIVER DECODER ELECTRICAL CHARACTERISTICS Supply Voltage Supply Current Quiescent Relays operating Relay Rating (240Vac)
TYPICAL
DIMENSION
TYPICAL 12.0
16.0
DIMENSION note
Note relays rated @240Vac, however track from relay screw terminals rated Care must taken ensure that power ratings overloaded. Relays output connections totally isolated from Decoder circuitry.
PART FM-RCH1-418RS FM-RCH2-418RS FM-RCH4-418RS PART FM-RCH1-433RS FM-RCH2-433RS FM-RCH4-433RS
DESCRIPTION Remote control System Channel, 418MHz Remote control System Channel, 418MHz Remote control System Channel, 418MHz DESCRIPTION Remote control System Channel, 433MHz Remote control System Channel, 433MHz Remote control System Channel, 433MHz
Stock Code 226-3499 226-3506 226-3512 Stock Code 250-0596 250-0603 250-0619
more information general enquiries, please call; Solutions Ltd., Unit Cliffe Industrial Estate, Lewes, Sussex. 6JL. England. Email sales@rfsolutions.co.uk http://www.rfsolutions.co.uk Tel: (0)1273 Fax: (0)1273
Solutions member Power Radio Association.
Information contained this document believed accurate however representation warranty given liability assumed R.F. Solutions Ltd. with respect accuracy such information. R.F.Solutions critical components life support systems authorised except with express written approval from R.F.Solutions Ltd.
DS000032
July
©1999 4001, ENGLAND.
Page

Other recent searches


TFDU4300 - TFDU4300   TFDU4300 Datasheet
Si4701DY - Si4701DY   Si4701DY Datasheet
SDV251S - SDV251S   SDV251S Datasheet
RL820 - RL820   RL820 Datasheet
RL826 - RL826   RL826 Datasheet
NP82N055CLE - NP82N055CLE   NP82N055CLE Datasheet
NP82N055DLE - NP82N055DLE   NP82N055DLE Datasheet
NP82N055ELE - NP82N055ELE   NP82N055ELE Datasheet
MBRP30060CT - MBRP30060CT   MBRP30060CT Datasheet
ESDA05C-4 - ESDA05C-4   ESDA05C-4 Datasheet
DP83840 - DP83840   DP83840 Datasheet
ADSP-21364 - ADSP-21364   ADSP-21364 Datasheet
2N6058 - 2N6058   2N6058 Datasheet
2N6059 - 2N6059   2N6059 Datasheet

 

Privacy Policy | Disclaimer
© 2012 Datasheet Archive