| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
Single Phase AMPS. Silicon Bridge Rectifiers Voltage Range 1000 V
Top Searches for this datasheetKBU801 THRU KBU807 Single Phase AMPS. Silicon Bridge Rectifiers Voltage Range 1000 Volts Current Amperes Recognized File E-96005 High surge current capability Ideal printed circuit board Reliable cost construction technique results inexpensive product High temperature soldering guaranteed: seconds 0.375" 9.5mm lead length lbs., tension Weight: grams .160(4.1) .140(3.6) .70(17.8) .66(16.8) .935(23.7) .895(22.7) .185(4.7) .165(4.2) .085(2.2) .065(1.7) .455(11.3) .405(10.3) .280(7.1) .260(6.6) .760(19.3) 1.0(25.4) .220(5.6) .180(4.6) .260(6.8) .180(4.5) .165(4.2) .150(3.8) .052(1.3) .048(1.2) Dimensions inches (millimeters) Maximum Ratings Electrical Characteristics Rating 25ambient temperature unless otherwise specified. Single phase, half wave, resistive inductive load. capacitive load, derate current Symbol Type Number Maximum Recurrent Peak Reverse Voltage VRRM Maximum Voltage VRMS Maximum Blocking Voltage Maximum Average Forward Rectified Current Peak Forward Surge Current, Single Half Sine-wave Superimposed Rated Load (JEDEC method Maximum Instantaneous Forward Voltage 8.0A Maximum Reverse Current TA=25 Rated Blocking Voltage TA=100 Typical Thermal Resistance (Note Operating Temperature Range Storage Temperature Range Units 1000 1000 I(AV) IFSM TSTG Note: Thermal Resistance from Junction Ambient Junction Case with units Mounted 0.25" Al-Plate. +125 +150 RATINGS CHARACTERISTIC CURVES (KBU801 THRU KBU807) FIG.1- MAXIMUM NON-REPETITIVE FORWARD SURGE CURRENT BRIDGE ELEMENT 8.3ms Single Half Sine Wave JEDEC Method FIG.2- MAXIMUM FORWARD CURRENT DERATING CURVE PEAK FORWARD SURGE CURRENT. AVERAGE FORWARD CURRENT. TJ=25 MOUNTED INCH COPPER BOARD 0.5" (12.7mm) LEAD LENGTH NUMBER CYCLES 60Hz AMBIENT TEMPERATURE. FIG.3- TYPICAL INSTANTANEOUS FORWARD CHARACTERISTICS BRIDGE ELEMENT FIG.4- TYPICAL REVERSE CHARACTERISTICS BRIDGE ELEMENT INSTANTANEOUS FORWARD CURRENT. INSTANTANEOUS REVERSE CURRENT. Tj=100 Tj=25 PULSE WIDTH-300 DUTY CYCLE Tj=25 INSTANTANEOUS FORWARD VOLTAGE. PERCENT RATED PEAK REVERSE VOLTAGE. Other recent searchesSN74LVC1G79 - SN74LVC1G79 SN74LVC1G79 Datasheet SML32SLF - SML32SLF SML32SLF Datasheet SM77D - SM77D SM77D Datasheet MN39591PT - MN39591PT MN39591PT Datasheet LT1941 - LT1941 LT1941 Datasheet L8576B - L8576B L8576B Datasheet APT1001R1AVR - APT1001R1AVR APT1001R1AVR Datasheet AD8005 - AD8005 AD8005 Datasheet ACT08 - ACT08 ACT08 Datasheet
Privacy Policy | Disclaimer |