update 94.03.21 AC-DC Power Module WaASC SERIES niature Modu


Datasheet Thumbnail

  

Download PDF



Top Searches for this datasheet




update 94.03.21
AC-DC Power Module
WaASC SERIES niature Modular Switching Power Supplies
FEATURES
Switching Power Module Mountable Fully Encapsulated Plastic Case Universal Input Range 90-264VAC, 47-440 Regulated Output Ripple Noise High Efficiency cUL, Approvals 2-Year Product Warranty
Watts
ELECTRICAL SPECIFICATIONS
Model Single Output ASC-3.3S
47-440
max. (115 VAC) max. (230 VAC)
max. (115 VAC) max. (230 VAC)
0.75 max.
slow blow type
3.3V
6000
470-23,000µF depending model
<0.2% Vout +40mV (Vp-p)
<0.5% Vout +50mV (Vp-p)
min.
Hiccup technique, auto-recovery
Zener diode clamp
Hiccup mode, indefinite (automatic recovery)
3000
-25°C.+70°C (with derating)
-40°C.+85°C
±0.02%/°C
>200,000 25°C (MIL-HDBK-217F)
0.98 Inches
Free convection
UL/cUL, TUV,
55022 class
55024
specifications valid nominal input voltage, full load +25°C after warm-up time unless otherwise stated.
ASC-5S
ASC-12S
ASC-15S
ASC-24S
Output Wattage Voltage
Frequency (Hz)
Input
90-264 120-370
Current (Full load)
Inrush Current (<2ms)
Leakage Current
External Fuse (recommend)
Voltage (V.DC.)
Voltage Accuracy
Current (mA)
Line Regulation (LL-HL) (typ.)
Load Regulation (5-00%) (typ.)
Minimum Load
Maximum Capacitive Load
Ripple
Noise
Efficiency
Hold-up Time
Switching Frequency
Over Power Protection
6000
2500
2000
1250
Output
Protection
Isolation
Over Voltage Protection
Short Circuit Protection
Input-Output (V.AC)
Operating Temperature
Storage Temperature
Environment
Temperature Coefficient
Humidity
MTBF
Dimension
Case Material
Weight
Cooling Method
Agency Approvals
(Conducted Radiated Emission)
(Noise Immunity)
89.0 63.5 25.0 Tolerance
Physical
Plastic resin with Fiberglass (flammability 94V-0)
Safety
http://www.archcorp.com.tw TEL: +886-2-26989508 FAX: +886-2-26981319
WWW.ASTRODYNE.COM
Myles Standish Blvd., Taunton, 02780 1-800-823-8082 Fax: 508-823-8181
update 94.03.21
AC-DC Power Module
niature Modular Switching Power Supplies
SERIES
ELECTRICAL SPECIFICATIONS
Model riple Output ASC-5D
47-440
max. (115 VAC) max. (230 VAC)
max. (115 VAC) max. (230 VAC)
0.75 max.
slow blow type
±3000
470-23,000µF depending model
<0.2% Vout +40mV (Vp-p)
<0.5% Vout +50mV (Vp-p)
min.
Hiccup technique, auto-recovery
Zener diode clamp
Hiccup mode, indefinite (automatic recovery)
3000
-25°C.+70°C (with derating)
-40°C.+85°C
±0.02%/°C
>200,000 25°C (MIL-HDBK-217F)
0.98 Inches
Free convection
UL/cUL, TUV,
55022 class
55024
Watts
series
ASC-12D
ASC-15D
ASC-5S12S
ASC-5S12D
ASC-5S15D
Output Wattage Voltage
Frequency (Hz)
Input
90-264 120-370
Current (Full load)
Inrush Current (<2ms)
Leakage Current
External Fuse (recommend)
Voltage (V.DC.)
Voltage Accuracy
Current (mA)
Line Regulation (LL-HL) (typ.)
Load Regulation (5-00%) (typ.)
Minimum Load
Maximum Capacitive Load
Ripple
Noise
Efficiency
Hold-up Time
Switching Frequency
Over Power Protection
±12V
±1250
±15V
±1000
5/12
3000/1250
5/±12
3000/±630
5/±15
3000/±500
Output
Protection
Isolation
Over Voltage Protection
Short Circuit Protection
Input-Output (V.AC)
Operating Temperature
Storage Temperature
Environment
Temperature Coefficient
Humidity
MTBF
Dimension
Case Material
Weight
Cooling Method
Agency Approvals
(Conducted Radiated Emission)
(Noise Immunity)
89.0 63.5 25.0 Tolerance
Physical
Plastic resin with Fiberglass (flammability 94V-0)
Safety
specifications valid nominal input voltage, full load +25°C after warm-up time unless otherwise stated.
Note
triple output required minimum loading output maintain specified regulation. damage these devices; however they meet listed specification. Load regulation triple output: Main output (V1): 100% with 100% balanced auxiliaries. Auxiliary outputs V3): 100% balanced outputs. Cross regulation triple output: Main output 100% load, auxiliary 100%, other auxiliary 100%. Auxiliary outputs V3): Main output 100% load, auxiliary 100%, other auxiliary 100% main output 25%, auxiliary 25%, other auxiliary 100%. Operation under no-load condition will
http://www.archcorp.com.tw TEL: +886-2-26989508 FAX: +886-2-26981319
WWW.ASTRODYNE.COM
Myles Standish Blvd., Taunton, 02780 1-800-823-8082 Fax: 508-823-8181
update 94.03.21
niature Modular Switching Power Supplies
SERIES
Dual
AC-DC Power Module
Watts
series
MECHANICAL DIMENSION
View
PIN#
SINGLE
5S/12S
Triple
+12V
COMMON
COMMON
NOCONNECT
BLOCK DIAGRAM
DERATING
WWW.ASTRODYNE.COM TEL: +886-2-26989508 FAX: +886-2-26981319
http://www.archcorp.com.tw
Myles Standish Blvd., Taunton, 02780 1-800-823-8082 Fax: 508-823-8181

Other recent searches


XO-820 - XO-820   XO-820 Datasheet
TVU0 - TVU0   TVU0 Datasheet
PA81J - PA81J   PA81J Datasheet
PA82J - PA82J   PA82J Datasheet
NTE308 - NTE308   NTE308 Datasheet
MC33272A - MC33272A   MC33272A Datasheet
MC33274A - MC33274A   MC33274A Datasheet
MC33272 - MC33272   MC33272 Datasheet
MC33274AP - MC33274AP   MC33274AP Datasheet
MC33274AD - MC33274AD   MC33274AD Datasheet
MC33272AP - MC33272AP   MC33272AP Datasheet
M62253FP - M62253FP   M62253FP Datasheet
1MBI1200U4C-170 - 1MBI1200U4C-170   1MBI1200U4C-170 Datasheet
1742520000 - 1742520000   1742520000 Datasheet

 

Privacy Policy | Disclaimer
© 2012 Datasheet Archive