| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
update 94.03.21 AC-DC Power Module WaASC SERIES niature Modu
Top Searches for this datasheetupdate 94.03.21 AC-DC Power Module WaASC SERIES niature Modular Switching Power Supplies FEATURES Switching Power Module Mountable Fully Encapsulated Plastic Case Universal Input Range 90-264VAC, 47-440 Regulated Output Ripple Noise High Efficiency cUL, Approvals 2-Year Product Warranty Watts ELECTRICAL SPECIFICATIONS Model Single Output ASC-3.3S 47-440 max. (115 VAC) max. (230 VAC) max. (115 VAC) max. (230 VAC) 0.75 max. slow blow type 3.3V 6000 470-23,000µF depending model <0.2% Vout +40mV (Vp-p) <0.5% Vout +50mV (Vp-p) min. Hiccup technique, auto-recovery Zener diode clamp Hiccup mode, indefinite (automatic recovery) 3000 -25°C.+70°C (with derating) -40°C.+85°C ±0.02%/°C >200,000 25°C (MIL-HDBK-217F) 0.98 Inches Free convection UL/cUL, TUV, 55022 class 55024 specifications valid nominal input voltage, full load +25°C after warm-up time unless otherwise stated. ASC-5S ASC-12S ASC-15S ASC-24S Output Wattage Voltage Frequency (Hz) Input 90-264 120-370 Current (Full load) Inrush Current (<2ms) Leakage Current External Fuse (recommend) Voltage (V.DC.) Voltage Accuracy Current (mA) Line Regulation (LL-HL) (typ.) Load Regulation (5-00%) (typ.) Minimum Load Maximum Capacitive Load Ripple Noise Efficiency Hold-up Time Switching Frequency Over Power Protection 6000 2500 2000 1250 Output Protection Isolation Over Voltage Protection Short Circuit Protection Input-Output (V.AC) Operating Temperature Storage Temperature Environment Temperature Coefficient Humidity MTBF Dimension Case Material Weight Cooling Method Agency Approvals (Conducted Radiated Emission) (Noise Immunity) 89.0 63.5 25.0 Tolerance Physical Plastic resin with Fiberglass (flammability 94V-0) Safety http://www.archcorp.com.tw TEL: +886-2-26989508 FAX: +886-2-26981319 WWW.ASTRODYNE.COM Myles Standish Blvd., Taunton, 02780 1-800-823-8082 Fax: 508-823-8181 update 94.03.21 AC-DC Power Module niature Modular Switching Power Supplies SERIES ELECTRICAL SPECIFICATIONS Model riple Output ASC-5D 47-440 max. (115 VAC) max. (230 VAC) max. (115 VAC) max. (230 VAC) 0.75 max. slow blow type ±3000 470-23,000µF depending model <0.2% Vout +40mV (Vp-p) <0.5% Vout +50mV (Vp-p) min. Hiccup technique, auto-recovery Zener diode clamp Hiccup mode, indefinite (automatic recovery) 3000 -25°C.+70°C (with derating) -40°C.+85°C ±0.02%/°C >200,000 25°C (MIL-HDBK-217F) 0.98 Inches Free convection UL/cUL, TUV, 55022 class 55024 Watts series ASC-12D ASC-15D ASC-5S12S ASC-5S12D ASC-5S15D Output Wattage Voltage Frequency (Hz) Input 90-264 120-370 Current (Full load) Inrush Current (<2ms) Leakage Current External Fuse (recommend) Voltage (V.DC.) Voltage Accuracy Current (mA) Line Regulation (LL-HL) (typ.) Load Regulation (5-00%) (typ.) Minimum Load Maximum Capacitive Load Ripple Noise Efficiency Hold-up Time Switching Frequency Over Power Protection ±12V ±1250 ±15V ±1000 5/12 3000/1250 5/±12 3000/±630 5/±15 3000/±500 Output Protection Isolation Over Voltage Protection Short Circuit Protection Input-Output (V.AC) Operating Temperature Storage Temperature Environment Temperature Coefficient Humidity MTBF Dimension Case Material Weight Cooling Method Agency Approvals (Conducted Radiated Emission) (Noise Immunity) 89.0 63.5 25.0 Tolerance Physical Plastic resin with Fiberglass (flammability 94V-0) Safety specifications valid nominal input voltage, full load +25°C after warm-up time unless otherwise stated. Note triple output required minimum loading output maintain specified regulation. damage these devices; however they meet listed specification. Load regulation triple output: Main output (V1): 100% with 100% balanced auxiliaries. Auxiliary outputs V3): 100% balanced outputs. Cross regulation triple output: Main output 100% load, auxiliary 100%, other auxiliary 100%. Auxiliary outputs V3): Main output 100% load, auxiliary 100%, other auxiliary 100% main output 25%, auxiliary 25%, other auxiliary 100%. Operation under no-load condition will http://www.archcorp.com.tw TEL: +886-2-26989508 FAX: +886-2-26981319 WWW.ASTRODYNE.COM Myles Standish Blvd., Taunton, 02780 1-800-823-8082 Fax: 508-823-8181 update 94.03.21 niature Modular Switching Power Supplies SERIES Dual AC-DC Power Module Watts series MECHANICAL DIMENSION View PIN# SINGLE 5S/12S Triple +12V COMMON COMMON NOCONNECT BLOCK DIAGRAM DERATING WWW.ASTRODYNE.COM TEL: +886-2-26989508 FAX: +886-2-26981319 http://www.archcorp.com.tw Myles Standish Blvd., Taunton, 02780 1-800-823-8082 Fax: 508-823-8181 Other recent searchesXO-820 - XO-820 XO-820 Datasheet TVU0 - TVU0 TVU0 Datasheet PA81J - PA81J PA81J Datasheet PA82J - PA82J PA82J Datasheet NTE308 - NTE308 NTE308 Datasheet MC33272A - MC33272A MC33272A Datasheet MC33274A - MC33274A MC33274A Datasheet MC33272 - MC33272 MC33272 Datasheet MC33274AP - MC33274AP MC33274AP Datasheet MC33274AD - MC33274AD MC33274AD Datasheet MC33272AP - MC33272AP MC33272AP Datasheet M62253FP - M62253FP M62253FP Datasheet 1MBI1200U4C-170 - 1MBI1200U4C-170 1MBI1200U4C-170 Datasheet 1742520000 - 1742520000 1742520000 Datasheet
Privacy Policy | Disclaimer |