| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
15.5 DC-4GHz, Serial Digital Attenuator Very Power Consumption At
Top Searches for this datasheetHRF-AT4511 15.5 DC-4GHz, Serial Digital Attenuator Very Power Consumption Attenuation Steps From 15.5 Single Dual Power Supply Voltages Serial Data Interface Compatible Impedance Space Saving LPCC Surface Mount Packaging Package Photo goes here Product Description Honeywell HRF-AT4511 5-bit digital attenuator that ideal broadband communication system applications that require accuracy, speed power consumption. HRF-AT4511 manufactured with Honeywell's patented Silicon Insulator (SOI) CMOS manufacturing technology, which provides performance GaAs with economy integration capabilities conventional CMOS. HRF-AT4511 LPCCPackage Electrical Specifications 25oC Parameter Insertion Loss Test Condition Frequency Minimum Typical 1.60 2.00 2.20 3.60 23.0 21.5 29.0 28.0 35.5 Maximum 1.80 2.10 2.40 3.80 Units Compression Compression Input Input Power Input Power Two-tone inputs Attenuation Input Two-tone inputs Attenuation Return Loss* Combination Bits Attenuation Accuracy attenuation states attenuation states attenuation states attenuation states Trise, Tfall* Ton, Toff (Tpd) Cntl 90%/10%RF Transients In-Band clock Period (Tprd)* high minimum clock period data (Tsup)* rising edge clock data hold (Thld)* Data hold after rising edge clock latch (Tlsup)* Data falling edge 0.01uF Decoupling Capacitors Required Power Supply Rails. design Site: Email: 2002 4511W www.mysoiservices.com mysoiservices@honeywell.com Published June 2002 Page 37.0 +/-(0.17 programmed +/-(0.22 programmed +/-(0.33 programmed +/-(0.45 programmed Honeywell Solid State Electronics Center 12001 State Highway Plymouth, Minnesota 55441-4799 1-800-323-8295 HRF-AT4511 Functional Schematic Electrical Specifications 25oC Parameter Minimum 3.3* Power Supply Current CMOS Logic level CMOS Logic level Input Leakage Current Note, performance curves VDD= +5.0 Typical Maximum -5.0 Units Absolute Maximum Ratings2 Parameter Input Power Voltage Operating Temperature Storage Temperature Digital Inputs Absolute Maximum +6.0 -5.5 +125 VDD+0.6 -0.6 Units Degrees Degrees (Note Operation this Device beyond these parameters cause permanent damage. Latch-Up: Unlike conventional CMOS digital attenuators, Honeywell's HRF-AT4511 immune latch-up. Protection: Although HRF-AT4511 contains protection circuitry digital inputs, conventional precautions should taken ensure that Absolute Maximum Ratings exceeded. Site: Email: 2002 4511W www.mysoiservices.com mysoiservices@honeywell.com Published June 2002 Page Honeywell Solid State Electronics Center 12001 State Highway Plymouth, Minnesota 55441-4799 1-800-323-8295 HRF-AT4511 Package Outline Drawing This package conforms LPCC4 lead body dimensions. ASAT LPCC Marketing Outline Dwg. DGMJ00004 Latest Rev. http://www.asat.com additional dimensional information. Configuration Function GROUND INPUT GROUND GROUND GROUND GROUND GROUND Function GROUND OUTPUT GROUND DIGITAL GROUND DATA Serial Data Load Serial data shifted into register rising edge clock, first. state "OE" will affect shifting data. rising edge "OE" signal will clock transfer shifted data. Latched data occurs prop delay after rising edge "OE". Electrical Spec Table parameters. Site: Email: 2002 4511W www.mysoiservices.com mysoiservices@honeywell.com Published June 2002 Page Honeywell Solid State Electronics Center 12001 State Highway Plymouth, Minnesota 55441-4799 1-800-323-8295 HRF-AT4511 Truth Table Output Reference Input 15.5 Operation: Data serial input clocked into internal registers high transition Clock signal (CK). register sampled during Output Enable (OE) state clocked into register during low-to-high transition Evaluation Circuit Board Honeywell's evaluation board provides easy method evaluating performance attenuator. Simply connect power, signals measuring attenuator performance less than minutes. HRF-AT4511 Evaluation Board Evaluation Circuit Board Layout Design Details Item Attenuator Chip Capacitor Connector Description Impedance Matched Multi-Layer HRF-AT4511 Digital Attenuator Panasonic Model ECU-E1C103KBQ Capacitor, .01uf 0402 Johnson Connectors Model 142-0701-801 Coaxial Connector Mil-Max Model 800-10-064-10-001 Header Pins Site: Email: 2002 4511W www.mysoiservices.com mysoiservices@honeywell.com Published June 2002 Page Honeywell Solid State Electronics Center 12001 State Highway Plymouth, Minnesota 55441-4799 1-800-323-8295 HRF-AT4511 Evaluation Circuit Board Connections Digital Data HRF-AT4511 Evaluation Board View HRF-AT4511 Honeywell Performance Curves Insertion Loss AT4511 Insertion Loss Attenuation State Frequency Frequency (GHz) S12(00000) S12(00001) S12(00010) S12(00011) S12(00100) S12(00101) S12(00110) S12(00111) S12(01000) S12(01001) S12(01010) S12(01011) S12(01100) S12(01101) S12(01110) S12(01111) S12(10000) S12(10001) S12(10010) S12(10011) S12(10100) S12(10101) S12(10110) S12(10111) S12(11000) S12(11001) S12(11010) S12(11011) S12(11100) S12(11101) S12(11110) S12(11111) Insertion Loss (dB) Site: Email: 2002 4511W www.mysoiservices.com mysoiservices@honeywell.com Published June 2002 Page Honeywell Solid State Electronics Center 12001 State Highway Plymouth, Minnesota 55441-4799 1-800-323-8295 HRF-AT4511 Return Loss AT4511 Return Loss Attenuation State Frequency Frequency (GHz) S11(00000) S11(00001) S11(00010) S11(00011) S11(00100) S11(00101) S11(00110) S11(00111) S11(01000) S11(01001) S11(01010) S11(01011) S11(01100) S11(01101) S11(01110) S11(01111) S11(10000) S11(10001) S11(10010) S11(10011) S11(10100) S11(10101) S11(10110) S11(10111) S11(11000) S11(11001) S11(11010) S11(11011) S11(11100) S11(11101) S11(11110) S11(11111) Return Loss (dB) AT4511 Return Loss Attenuation State Frequency Frequency (GHz) S22(00000) S22(00001) S22(00010) S22(00011) S22(00100) S22(00101) S22(00110) S22(00111) S22(01000) S22(01001) S22(01010) S22(01011) S22(01100) S22(01101) S22(01110) S22(01111) S22(10000) S22(10001) S22(10010) S22(10011) S22(10100) S22(10101) S22(10110) S22(10111) S22(11000) S22(11001) S22(11010) S22(11011) S22(11100) S22(11101) S22(11110) S22(11111) Site: Email: 2002 4511W www.mysoiservices.com mysoiservices@honeywell.com Published June 2002 Page Honeywell Solid State Electronics Center 12001 State Highway Plymouth, Minnesota 55441-4799 1-800-323-8295 Return Loss (dB) HRF-AT4511 Step Accuracy AT4511 Step Accuracy Attenuation Step Step Delta (dB) -0.1 StepAcc@0.01GHz -0.3 -0.5 -0.7 -0.9 -1.1 -1.3 -1.5 StepAcc@0.1GHz StepAcc@0.5GHz StepAcc@1GHz StepAcc@2GHz StepAcc@3GHz StepAcc@4GHz Programmed Attenuation (dB) Relative Accuracy AT4511 Relative Accuracy Attenuation RelAcc@0.01GHz RelAcc@0.1GHz RelAcc@0.5GHz RelAcc@1GHz RelAcc@2GHz RelAcc@3GHz RelAccMax RelAccMin Relative Accuracy (dB) -0.5 -1.5 Programmed Attenuation (dB) Site: Email: 2002 4511W www.mysoiservices.com mysoiservices@honeywell.com Published June 2002 Page Honeywell Solid State Electronics Center 12001 State Highway Plymouth, Minnesota 55441-4799 1-800-323-8295 HRF-AT4511 Ordering Information Ordering Number HRF-AT4511-B HRF-AT4511-TR HRF-AT4511-E (Note Call Honeywell details Delivery Method Chip Tubes Tape Reel Individual Engineering Evaluation Board Units Shipment Customer Specific, Usually Minimum Chip Tube 3000 Units Reel Board LPCCis registered Trademark ASAT Ltd. Honeywell reserves right make changes improve reliability, function design. Honeywell does assume liability arising application product circuit described herein; neither does convey license under patent rights rights others. Site: Email: 2002 4511W www.mysoiservices.com mysoiservices@honeywell.com Published June 2002 Page Honeywell Solid State Electronics Center 12001 State Highway Plymouth, Minnesota 55441-4799 1-800-323-8295 Other recent searchesTA1067A - TA1067A TA1067A Datasheet PLL2115X - PLL2115X PLL2115X Datasheet pll2115x - pll2115x pll2115x Datasheet PDI-E825 - PDI-E825 PDI-E825 Datasheet Edge4707 - Edge4707 Edge4707 Datasheet DE5S6M - DE5S6M DE5S6M Datasheet AQS75O - AQS75O AQS75O Datasheet
Privacy Policy | Disclaimer |