| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
2010TC Differential Pressure, Pressure Temperature (Mass Flow) Sp
Top Searches for this datasheetMulti VisionMultivariable Transmitter 2010TC Differential Pressure, Pressure Temperature (Mass Flow) Spans: mbar 10/15-4.12 2010TCSW.TIF Compensated mass flow measurement Measured media: gases, vapours, liquids Accuracy: 0.075% (option 0.05%) sided overload rated pressure; max. Large turn down ratio Span zero externally adjustable conjunction with indicator, transmitter configured with external keys Communication protocol: PROFIBUS Foundation Fieldbus HART, 4.20mA Explosion protection: "Intrinsic Safety" "Flameproof Enclosure" connection "Zone Surge voltage resistant acc. 61000-4 Interchangeable electronics with self reconfiguration Application transmitter 2010TC Multi Vision series mass flow measuring device with analogue digital output signal process industry. transmitter 2010TC measures accurately simultaneously differential pressure, static pressure with four-wire technique process temperature aggressive non-agressive media. electronics calculate compensated mass flow using these dynamic fluid conditions. measuring ranges from mbar MPa), each nominal pressure ranges bar. 2010TC Differential Pressure, Pressure Temperature (Mass Flow) Technical data Principle Operation Construction transmitter modular design consists differential pressure sensor module with integrated electronic matching unit, amplifier with control unit well input four-wire technique process temperature. mbar mbar 10/15-4.12 mbar pabs sensor: adjusted span must lower than minimum span Measuring ranges Code min. max. Process temperature External four-wire technique RTD: +650 Output Output signal Transmitters with 4.20mA Analogue signal Output signal limits: Imin Imax 22.5 (configurable). Standard setting: Imin Imax 20.5 Alarm current Min. alarm current: configurable from standard setting: Max. alarm current: configurable from 22.5 standard setting: Standard setting: max. alarm current Load Transmitters with 4.20 kOhm Transmitter 2010TC completely welded sensor module twin-chamber system with integral overload diaphragm, internal absolute pressure sensor silicon differential pressure sensor. absolute pressure sensor, which only exposed pressure high pressure side acts reference value compensate static pressure. differential pressure sensor connected capillary tube negative side sensor module. applied differential pressure (dp) transferred separating diaphragm fill fluid diaphragms silicon differential pressure sensor. minimal deflection silicon diaphragm changes output voltage pick-up system. This pressure proportional output voltage digialized machting electronics amplifier. amplifier linearizes temperature compensates this signal before together with values converted into compensated mass flow proportional signal. Apart from mass flow (qm) values also available further use. Input Measured value Differential pressure, static pressure (absolute pressure) process temperature Upper lower range values dp-sensor Lower range value (continuously adjustable) -100% +100% Upper range value (continuously adjustable) 100% Spans dp-sensor: adjusted span must lower than minimum span (recommendation square root function: least range). Measuring ranges Code min. max. mbar mbar mbar mbar Imax 22.5 (configurable) supply voltage min. power supplyy: 10.5 VDC, with backlit LCD-indicator min. load digital communications Field units (communication code: Digital signal Transmission technique: acc. 61158-2 Power supply: Base current: Transmission rate: 31.25 kbits/s PROFIBUS-PA: Version 3.0, Profile pressure transmitters; Ident No.: 04C2 Foundation Fieldbus: FF-890 FF-902 Characteristic Mass flow calculation, compensating pressure temperature effects completely. Calculation performed formula: Accuracy Reference conditions Temperature: Relative humidity: Atmospheric pressure: 1013mbar (1013 hPa) additional conditions: Separating diaphragm material "Hastelloy filll fluid "silicone oil" specifications limits relate output range calibrated range. influences marked relate measuring range (URL) multiplied turn down factor. turn down factor should kept minimum. Page 08.2000 2010TC Differential Pressure, Pressure Temperature (Mass Flow) Technical data Conformity dp-sensor: 0.075 terminal based, including hysteresis dead band (optional 0.05 pabs-sensor: Process temperature measurement (RTD): Reproducibility 0.01 Hysteresis 0.05 Warm-up time Rise time dependent range turn down ratio 0.1s 1.6s range mbar additional adjustable time constant 0.60s 10/15-4.12 effect appearing output square rooting function depends function calculated accordingly. Long-term drift 0.05% months Effect position Ranges mbar zero approx. mbar angular deviation degrees from nominal mounting position) Ambient temperature effect (dp- pabs-sensor) Thermal change (-40°C +80°C) 3)4) zero span dp-sensor pabs-sensor 3)4) Temperature coefficient (-40°C +80°C) zero 0.04 span dp-sensor 0.04 pabs-sensor 0.04 Static pressure effect Range mbar zero 0.05 span 0.05 Ranges mbar zero 0.05 span 0.05 Ambient conditions Ambient temperature Observe approvals explosion-protected transmitters. Storage temperature transport temperature with LCD-indicator Humidity Relative humidity: annual average Condensation, icing: admissible Protection class Paintwork epoxy resin, greywhite, 9002 Shock resistant Acceleration: Duration: 11ms Vibration resistance 1000 Electromagnetic compatibility (EMC) acc. 61000-4-2 Definition: Class Frequency range (IEC 61000-4-3): 1000 Radio suppression 011): Limit class Fulfills NAMUR recommendation. Process conditions Temperature limits process connection +400 conjunction with remote seals. O-rings Viton (FPM) Pressure limits Static pressure limits: from abs. mbar abs.) nominal pressure Proof pressure 1.5-times nominal pressure simultaleously both sides transmitter admissible. Overload limit One-sided overload rated pressure. Weight Material Measuring cell: stainless steel Separating diaphragm(s): Hastelloy stainless steel (1.4435) Tantalum Monel gold plated Process flange: stainless steel (1.4571)* Hastelloy Monel* PVDF Nuts bolts: stainless steel (A4)* Plugs: process flange material Fill fluid: Silicone carbon fluoride O-rings: Viton (FPM) Perbunan (NBR) PTFE* EPDM* Amplifier housing Housing cover: aluminium with epoxy resin coat stainless steel compliance with NACE MR0175 Class Process connection Flange with fixing thread 7/16-20 1/4-18 female thread both sides flange connection with thread 1/4-18 female thread both sides. with Tantalum, Monel Gold Plated Isolating Diaphragm, factor taken into account with static pressure ambient temperature effect with conformity additionally with turn-down factor 1:10 measuring range 0.005 0.05 adjusted span with range 10mbar: with carbon fluoride filling liquid: General conditions Installation conditions Notes installation Installation position: transmitter directly flanged position. Preferably such position that process flange axes vertical (horizontal with barrel-type amplifier housing). Deviations from this cause shift zero, which corrected. electronic housing rotated through 360° fixed position. stop prevents housing beeing turned far. 08.2000 Page 2010TC Differential Pressure, Pressure Temperature (Mass Flow) Technical data Electrical connections female threads 1/2-14 plug Screw terminals wire cross-sections mm2. Cable connection compartment electrical connection 10/15-4.12 indicator 2-line, 6-character 19-segment alphanumeric display with additional chart display, optionally with back illumination. User-specific displays: mass flow value physical unit percentage output current mass flow value percentage, alternating every seconds output current instrument temperature freely selectable units free process variable Diagnostic messages, alarms, measuring range infringements changes configuration also displayed. Power supply Transmitters with 4.20mA (communication code: Power supply: 10.5 with backlit indicator), inverse polarity protection, explosion-protected transmitters, observe approvals. Harmonic distortion: Maximal permissible voltage ripple power supply during communication: 50Hz 100Hz 100Hz 200Hz 200Hz 300Hz Field units (communication code: Power supply: withbacklit indicator), inverse polarity protection, explosion-protected transmitters, observe approvals. Electrical connection with plug Dimensions inches (millimeters). Certificates Approvals (pending) Explosion protection, intrinsically safe Marking (DIN 014): Connection intrinsically safe circuit with maximum values: Temperature class Ambient temp. maximum Umax Imax Pmax ,,barrel-type" ,,DIN-type" Display operation interface Operation with keys Retrofit optional unit external adjustment zero span write protect switch. There physical connections through housing keys. conjunction with indicator, transmitter configured with keys follows: Zero span with without applied pressure, oblique sensor, damping, output current during faults, displayed value, pressure unit, linear square rooting, incl. zero suppression change over temperature unit. Operation remote communications Communication protocol: PROFIBUS-PA© Foundation Fieldbus© HART© Bailey-FSK Hardware: HART© Bailey-FSK: modem notebook Handheld Terminal: Internal capacitance 0.01 internal inductance negligible Explosion protection, flameproof enclosure Marking (DIN 014): Operating conditions: max. ambient temperature Factory Mutual (FM) Explosion protection: Explosion protected areas: Degree protection: Class Division Groups Class II/III, Division Groups Indoor outdoor NEMA Type Canadian Standard (CSA) Explosion protection: Class Division Groups Class Division Groups Class Explosion protected areas: Indoor outdoor Degree protection: NEMA Type Page 08.2000 2010TC Differential Pressure, Pressure Temperature (Mass Flow) Model ordering number 2010TC Differential Pressure, Pressure Temperature (Mass Flow) Catalog V15714P adj. adj. adj. adj. adj. adj. Code 10/15-4.12 EURO Multivariable Transmitter 2010TC mass flow Communication PROFIBUS-PA Foundation Fieldbus HART, 4.20 Measuring Ranges mbar (1kPa inch H2O) (max. bar) mbar (6kPa inch H2O) mbar (40kPa inch H2O) (250kPa 1000 inch H2O) (2MPa psi) (10MPa 1500 psi) Measuring Ranges pabs-sensor Measuring sensor Fill fluid Silicone Carbon fluoride stainless steel (1.4435) Silicone (not 2010TA) Carbon fluoride Tantalum Silicone Carbon fluoride Monel Silicone Carbon fluoride Gold plated Silicone Carbon fluoride Process flange, sides identical Diaphragm Hastelloy intern 368,00 699,00 921,00 479,00 921,00 479,00 74,00 stainless steel (1.4571) Nominal pressure Hastelloy corresponding Monel measuring range pabs-sensor Process Connection Position thread holes drain vent valves (scope delivery: plugs only) 7/16 1/4-18 upright female thread side acc. 19213 upright (M10/M12 1/4-18 NPT) side Bolts Flange O-rings Stainless Steel Viton Perbunan PTFE EPDM NACE application Continued next page. 08.2000 Page 2010TC Differential Pressure, Pressure Temperature (Mass Flow) Model ordering number Continued from preceding page. Catalog Type Barrel Type, Plate Plastic Barrel Type, Plate Plastic Type, Plate Plastic Function Customer-specific adjustment Conformity 0.05 Amplifier housing accessories Local keys indicator indicator, back Transient Suppression Explosion Protection Explosion Proof Intrinsically Safe Intrinsically Safe Zone Mounting Bracket Wall pipe mounting, carbon steel Wall pipe mounting, stainless steel Vent drain plug Stainless Steel Hastelloy Flange Adapter (material: oval flange screws) (material: oval flange bolts) Oval flange 1/2-14 NPT(stainless steel carbon steel) Oval flange 1/2-14 NPT(stainless steel stainless steel) Tag-No. Stainless Steel Plate Operating anual German English Material Aluminium Electrical connection cable gland Plug cable gland cable gland Plug Code 10/15-4.12 EURO intern Stainless Steel Aluminium Continued next page. Page 08.2000 2010TC Differential Pressure, Pressure Temperature (Mass Flow) Model ordering number Continued from preceding page. Catalog Certificates Factory Certificate ,,EN 204" instrument design Acceptance Test Certificate ,,EN 204" conformity, hysteresis Acceptance Test Certificate ,,EN 204" pressure testing Factory Certificate ,,EN 204" process wetted parts Acceptance Test Certificate ,,10 204" Cleanliness Stage acc. 25410 Acceptance Test Certificate ,,EN 204" Helium leakage test sensor module Acceptance Test Certificate ,,EN 204" pressure-bearing process wetted parts with analysis certificates material verification (minor parts with Factory Certificate acc. 204) Factory Certificate ,,EN 204" pressure-bearing process wetted parts Measuring mechanism leak-tested with helium Scope Delivery Instructions Instrument socket with plug connector Plugs Code 10/15-4.12 EURO intern Supplied against special order: Remote Seal, Power supply e.g. (Data Sheet 18-8.39 Spare Parts Transmitter 2010TD 2010TA (Data Sheets 10-3.22 10-3.24 08.2000 Page 2010TC Differential Pressure, Pressure Temperature (Mass Flow) Dimensional drawings Construction Transmitter with barrel-type amplifier housing Errors omissions excepted. Dimensions inches (mm). 10/15-4.12 Connections this side 1/4-18 female thread process connection sealing plug. Thread fixing screws: 7/16-20 UNF, 16mm deep. Minimum screw-in length 12mm, however 15mm with PN400. With flange according 19213: with bar, with bar, minimum screw-in length according 19213. Electrical connections: cable gland both sides 1/2-14 female threads both sides plug Type plate. Measuring mechanism plate. Threaded side-mounted entry 1/4-18 drain vent valves. Captive screw unit cover. Housing rotation stop screw. Blind plug. Enclosure cover. Tie-on plate, e.g. number (optional). Plate, also with legend. Page 08.2000 2010TC Differential Pressure, Pressure Temperature (Mass Flow) Dimensional drawings Transmitter with DIN-type amplifier housing Errors omissions excepted. Dimensions inches (mm). 10/15-4.12 1/4-18 female thread process connection sealing plug. Thread fixing screws: 7/16-20 UNF, 16mm deep. Minimum screw-in length 12mm, however 15mm with PN400. With flange according 213: with bar, with bar, minimum screw-in length according 213. Electrical connections: cable gland both sides 1/2-14 female threads both sides plug Type plate. Measuring mechanism plate. Threaded side-mounted entry 1/4-18 drain vent valves. Captive screw unit cover. Housing rotation stop screw. Blind plug. Enclosure cover. Tie-on plate, e.g. number (optional). Plate, also with legend. Connections this side 08.2000 Page Automation Products GmbH D-32425 Minden Tel. http://www.abb.de/automation Subject technical changes. Printed Fed. Rep. Germany 10/15-4.12 08.2000 Other recent searchesVFTX160 - VFTX160 VFTX160 Datasheet VDL1584 - VDL1584 VDL1584 Datasheet STPS2L40 - STPS2L40 STPS2L40 Datasheet FAN5099 - FAN5099 FAN5099 Datasheet AN9405 - AN9405 AN9405 Datasheet AMS431 - AMS431 AMS431 Datasheet 2SC5488A - 2SC5488A 2SC5488A Datasheet
Privacy Policy | Disclaimer |