| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
This infrared analyzer measures concentration utilizing characteristic
Top Searches for this datasheetNDIR TYPE INFRARED ANALYZER This infrared analyzer measures concentration utilizing characteristic (molecule consisting different-kind atoms) that absorbs infrared specific wavelength. Stable accurate measurement ensured mass flow sensor with high sensitivity, interferencecompensating detector, etc. This analyzer built sampling equipment optimally usable measuring concentrations various gases. ZRC6 FEATURES Most suited incorporation equipment This analyzer readily built customer's sampling equipment, because analyzing block, signal processing circuit power unit accommodated compact case. High measurement accuracy stability single light source/double beam system, highsensitivity mass flow sensor ensure accurate stable measurement. Minimum influence other gases interference-compensating detector substantially suppresses interference disturbing gases coexisting sample gas. Wide dynamic range range ratio max. 1:20 secured standard ranges. Range selection follows external selection input signal. inlet, outlet, purge inlet size: Rc1/4, NPT1/4 female screw Purge flow rate: 1L/min± 0.5L/min Purging required when combustible corrosive gases contained atmosphere range less than 100ppm. other cases, purging should made necessary. Scope delivery: Analyzer power fuse Instruction manual Mounting method: table-top Installation condition: Install analyzer place exposed direct sunlight radiation from high temperature object. Avoid vibration, select clean place free from corrosive and/or combustible gasses. installing outdoors, provide suitable casing cover protect analyzer from wind, rain, etc. Standard Requirements measuring gases: Temperature: 50°C Moisture: Below level where saturation occurs (condensation unallowable). Dust: 0.3µm less (Recommended membrane filter; ZBBM6) Pressure: 10kPa less (Flow rate: 0.5L/min)(Gas outlet side should open atmospheric air) Standard control sample gas: Calibration gas: Interfere control gas: saturation Measuring system: Infrared-ray absorption method, non-dispersion, differential flow system, single light source, double-beam system. SPECIFICATIONS Power Supply: 100V-240V 50/60Hz Power supply voltage variation running time; within 10%. Power consumption:130VA Ambient temperature: +45°C Ambient humidity: less Enclosure temperature: +60°C Enclosure humidity: less Casing: Zinc plated steel (Special chromate) (JIS: SECC-C equivalent) steel color Indoor-use Dimensions Table-top Mass (Weight): Approx. Warm-up time: About hours (after power Materials gas-contacting parts: Sample cell: SUS304, chloroprene rubber Infrared-ray transmitting window: CaF2 sapphire Internal tubing: fluoride ethylene resin EDS3-126 Date May. 2003 ZRC6 Measurable components measuring ranges: Measurable components Carbon monoxide Carbon dioxide Nitric oxide Sulfur dioxide Minimum Maximum measuring range measuring range 100ppm 50ppm 100ppm 100ppm 100vol 100vol 2000ppm 10vol CODE SYMBOLS ZRC6 Description Basic structure Single-component analyzer (bench) Measuring ranges: Shown another table Range selection: Short circuit between external terminal and14 switches high range side. Output signal: DC/4 20mA Simultaneous output Linearity: full scale DC/permissible load resistance; 100k more 20mA DC/permissible load resistance; less Repeatability: 0.5% full scale Zero drift: full scale/week Span drift: full scale/week Response time: Maximum within seconds including replacement time sample gas. (for response) differs from length sample cell. Measured flow rate: Standard 0.5L/min± 0.1L/min Measuring components (Carbon monoxide) (Carbon dioxide) (Nitric oxide) (Sulfur dioxide) measuring range Note: measuring range, refer Table. 50ppm 100ppm 200ppm 250ppm 500ppm 1000ppm 2000ppm 5000ppm 100% measuring range range aperture shape Rc1/4 female screw Power Supply 100V 240V 50/60Hz Measurable type Atmosphere Combustion exhaustion Converter exhaustion Principle diagram infrared type measurement Motor Distribution cell Trimmer (interference filter) Reference cell Interference compensation detector Rotation sector Sector sync signal Sample cell Infrared light source (Single-beam light source) Sample inlet Converter Sample outlet amplification Range switching Output 20mA (Simultaneous output) Smooth- Synchronous Linearizer amplification genarator Table Measurable component range availability check table Single-component analyzer (NO, analyzer measurable range analyzer measurable range range range 50ppm 100ppm 200ppm 250ppm 500ppm 1000ppm 2000ppm 5000ppm 100% 100ppm analyzer measurable range analyzer measurable range 500ppm 200ppm 1000ppm 2000ppm 5000ppm 250ppm 100% range range 50ppm 100ppm 200ppm 250ppm 500ppm 1000ppm 2000ppm 5000ppm 100% ZRC6 OUTLINE DIAGRAM (Unit:mm) Analyzer main unit Connecting terminal BACK Fuse Purge inlet RC1/4 NPT1/4 Sampling outlet RC1/4 NPT1/4 Sampling inlet RC1/4 NPT1/4 PURGE SIDE UPPER (229) (210) FRONT (432.5) (176) (164) SPAN CAL. (VR4) ZERO CAL. (VR7) CONNECTING DIAGRAM Zero Adj./Span Adj. Power supply 100V 240V Output Output Range 20mA Check (0.04 0.2V Caution Safety *Before using this product, sure read instruction manual advance. Head office 6-17, Sanbancho, Chiyoda-ku, Tokyo 102-0075, Japan http://www.fesys.co.jp Sales Div. International Sales Dept. No.1, Fuji-machi, Hino-city, Tokyo, 191-8502 Japan Phone: 81-42-585-6201, 6202 Fax: 81-42-585-6187 http: //www.fic-net.co.jp Information this catalog subject change without notice. SOURCE FUSE INLET OUTLET Printed Japan Other recent searchesXC95216 - XC95216 XC95216 Datasheet PLL401-2150A - PLL401-2150A PLL401-2150A Datasheet MN1300 - MN1300 MN1300 Datasheet LT9841-81 - LT9841-81 LT9841-81 Datasheet IDT709279 - IDT709279 IDT709279 Datasheet CXA3791EN - CXA3791EN CXA3791EN Datasheet
Privacy Policy | Disclaimer |