NDIR TYPE INFRARED ANALYZER
This infrared analyzer measures concentration utilizing characteristic (molecule consisting different-kind atoms) that absorbs infrared specific wavelength. Stable accurate measurement ensured mass flow sensor with high sensitivity, interferencecompensating detector, etc. This analyzer built sampling equipment optimally usable measuring concentrations various gases.
ZRC6
FEATURES
Most suited incorporation equipment This analyzer readily built customer's sampling equipment, because analyzing block, signal processing circuit power unit accommodated compact case. High measurement accuracy stability single light source/double beam system, highsensitivity mass flow sensor ensure accurate stable measurement. Minimum influence other gases interference-compensating detector substantially suppresses interference disturbing gases coexisting sample gas. Wide dynamic range range ratio max. 1:20 secured standard ranges. Range selection follows external selection input signal. inlet, outlet, purge inlet size: Rc1/4, NPT1/4 female screw Purge flow rate: 1L/min± 0.5L/min Purging required when combustible corrosive gases contained atmosphere range less than 100ppm. other cases, purging should made necessary. Scope delivery: Analyzer power fuse Instruction manual Mounting method: table-top Installation condition: Install analyzer place exposed direct sunlight radiation from high temperature object. Avoid vibration, select clean place free from corrosive and/or combustible gasses. installing outdoors, provide suitable casing cover protect analyzer from wind, rain, etc. Standard Requirements measuring gases: Temperature: 50°C Moisture: Below level where saturation occurs (condensation unallowable). Dust: 0.3µm less (Recommended membrane filter; ZBBM6) Pressure: 10kPa less (Flow rate: 0.5L/min)(Gas outlet side should open atmospheric air) Standard control sample gas: Calibration gas: Interfere control gas: saturation Measuring system: Infrared-ray absorption method, non-dispersion, differential flow system, single light source, double-beam system.
SPECIFICATIONS
Power Supply: 100V-240V 50/60Hz Power supply voltage variation running time; within 10%. Power consumption:130VA Ambient temperature: +45°C Ambient humidity: less Enclosure temperature: +60°C Enclosure humidity: less Casing: Zinc plated steel (Special chromate) (JIS: SECC-C equivalent) steel color Indoor-use Dimensions Table-top Mass (Weight): Approx. Warm-up time: About hours (after power Materials gas-contacting parts: Sample cell: SUS304, chloroprene rubber Infrared-ray transmitting window: CaF2 sapphire Internal tubing: fluoride ethylene resin
EDS3-126
Date May. 2003
ZRC6
Measurable components measuring ranges:
Measurable components Carbon monoxide Carbon dioxide Nitric oxide Sulfur dioxide Minimum Maximum measuring range measuring range 100ppm 50ppm 100ppm 100ppm 100vol 100vol 2000ppm 10vol
CODE SYMBOLS
ZRC6
Description Basic structure Single-component analyzer (bench)
Measuring ranges: Shown another table Range selection: Short circuit between external terminal and14 switches high range side. Output signal: DC/4 20mA Simultaneous output Linearity: full scale DC/permissible load resistance; 100k more 20mA DC/permissible load resistance; less Repeatability: 0.5% full scale Zero drift: full scale/week Span drift: full scale/week Response time: Maximum within seconds including replacement time sample gas. (for response) differs from length sample cell. Measured flow rate: Standard 0.5L/min± 0.1L/min
Measuring components (Carbon monoxide) (Carbon dioxide) (Nitric oxide) (Sulfur dioxide) measuring range Note: measuring range, refer Table. 50ppm 100ppm 200ppm 250ppm 500ppm 1000ppm 2000ppm 5000ppm 100% measuring range range aperture shape Rc1/4 female screw Power Supply 100V 240V 50/60Hz Measurable type Atmosphere Combustion exhaustion Converter exhaustion
Principle diagram infrared type measurement
Motor Distribution cell Trimmer (interference filter) Reference cell Interference compensation detector
Rotation sector
Sector sync signal
Sample cell Infrared light source (Single-beam light source) Sample inlet Converter
Sample outlet amplification Range switching
Output 20mA (Simultaneous output)
Smooth- Synchronous Linearizer amplification genarator
Table Measurable component range availability check table
Single-component analyzer (NO,
analyzer measurable range analyzer measurable range range range 50ppm 100ppm 200ppm 250ppm 500ppm 1000ppm 2000ppm 5000ppm 100%
100ppm
analyzer measurable range analyzer measurable range
500ppm
200ppm
1000ppm
2000ppm
5000ppm
250ppm
100%
range range 50ppm 100ppm 200ppm 250ppm 500ppm 1000ppm 2000ppm 5000ppm 100%
ZRC6
OUTLINE DIAGRAM (Unit:mm)
Analyzer main unit
Connecting terminal BACK Fuse
Purge inlet RC1/4 NPT1/4 Sampling outlet RC1/4 NPT1/4 Sampling inlet RC1/4 NPT1/4
PURGE
SIDE
UPPER
(229)
(210)
FRONT (432.5)
(176)
(164)
SPAN CAL. (VR4)
ZERO CAL. (VR7)
CONNECTING DIAGRAM
Zero Adj./Span Adj.
Power supply 100V 240V
Output Output Range 20mA
Check (0.04 0.2V
Caution Safety *Before using this product, sure read instruction manual advance.
Head office
6-17, Sanbancho, Chiyoda-ku, Tokyo 102-0075, Japan http://www.fesys.co.jp
Sales Div. International Sales Dept.
No.1, Fuji-machi, Hino-city, Tokyo, 191-8502 Japan Phone: 81-42-585-6201, 6202 Fax: 81-42-585-6187 http: //www.fic-net.co.jp
Information this catalog subject change without notice.
SOURCE FUSE INLET OUTLET
Printed Japan

Other recent searches


XC95216 - XC95216   XC95216 Datasheet
PLL401-2150A - PLL401-2150A   PLL401-2150A Datasheet
MN1300 - MN1300   MN1300 Datasheet
LT9841-81 - LT9841-81   LT9841-81 Datasheet
IDT709279 - IDT709279   IDT709279 Datasheet
CXA3791EN - CXA3791EN   CXA3791EN Datasheet

 

Privacy Policy | Disclaimer
© 2012 Datasheet Archive