This NDIR analyzer used measuring CO2, features high accuracy, multipl
Top Searches for this datasheetNDIR TYPE INFRARED ANALYZER This NDIR analyzer used measuring CO2, features high accuracy, multiple functions easy operation through microprocessor. housed inch rack case suitable mounting panel table-top. analyzer provides performance superior conventional double-beam system, easy maintain, offers excellent long-term stability. thus optimum continuous measurement combustion control various industrial furnaces, research garden-plants, FEATURES microprocessor provides high accuracy, multiple functions easy operation. Zero span calibration accurate easy just pressing calibrating keys. self-diagnosis function included. automatic calibrating function provided option. Range changed over external signal option. improved optical system provides long term stability, there minimum drift caused contamination measuring cell, long-term stability excellent. Adopting serial dual-layer type transmission detector minimizes remarkable interface from other components. Easy maintenance. single-beam photometric system uses sample cell only eliminates necessity delicate adjustment optical balance. instrument designed unit simple construction featuring easy maintenance checks. SPECIFICATIONS Measurable components: Single-component SO2, CH4: Dual-component CO2/CO: Landfill garbage application CO2: Measuring range: Refer measurable range combination table (page Measuring system: Non-dispersion infrared-ray absorption method, deviation method, single light source single beam Output signal: Output Output 20mA (optional allowable load resistance less). Repeatability: range (low range) Within 0.5% full scale range (high range) Within full scale Linearity: full scale Zero drift: Within full scale/week Span drift: Within full scale/week Response time: Within seconds max. (for response) depending cell length Power supply: 100V, 115V, 220V 240V 60Hz Power consumption: 37VA max. EDS3-111c Date Oct. 1998 Ambient temperature: +45°C Ambient humidity: less Enclosure: Steel casing, indoor Storage condition: Temperature; +60°C Humidity; 100% max. (free from condensation) Outer dimensions Rack mounting type; Panel flush mounting type; Table-top type; Mass weight: Approx. 12Kg Finish color: Munsell 2.5Y8.4/1.2 Display: digit concentration display digit sub-display Output hold: Output value before manual automatic calibration hold. Whether effect hold function selected. Sample condition: Temperature; 50°C Dust; less than Pressure; less than Standard adjustment gas: Balance Warm time: Approx. hours Material gas-contacting parts: Sample cell, SUS304, neoprene rubber Infrared-ray transmitting window; CaF2 sapphire Internal tubing; Toaron tube inlet/outlet, purge inlet size: Rc1/4 (PT1/4 internal thread) NPT1/4 internal thread Measured flow rate: liter/minutes Purge flow rate: Approx. liter/minute Scope delivery:Analyzer, power fuse, manual, mounting bracket case panel mounting type Mounting method: Mounted inch rack, panel, table-top Optional specifications Remote output hold: Analog output (DC0-1V, 4-20mA) held external signal. Input signal: Remote range changeover: Range changeable external signal. Range changeover input signal: Range identification signal output: Contact output; contact Contact capacity; 250V (resistive load) Automatic calibration: Zero span automatically calibrated preset cycle. Calibration supplied sequentially driving electromagnetic value installed outside. Calibration channel: components calibrated simultaneously. Zero calibration point: Fixed Span calibration point: 100% full scale Calibration start: built-in timer remote start signal Output hold calibration: Possible Calibration flow mode: Zero Zero span Zero span Zero span span Calibration flow time: Settable from sec. Calibration cycle: hours 1-hour step) Calibration failure alarm: Provided when fault occurs during auto calibration. Contact output: During calibration; (N.O) contact, contact capacity 250V (resistive load) Calibration failure; (N.O) contact, contact capacity 250V (resistive load) Electromagnetic valve drive; (N.O) contact, contact capacity 250V (resistive load) Remote start: Remote start signal; voltage input approx. 250mm Support Remark: more analyzer weight should supported bottom case. case mounting panel inch rack, provide support rear casing.) Installation conditions: Install analyzer place exposed direct sunlight radiation from high temperature object. void vibration, select clean place free corrosive and/or combustible gases. installing outdoors, provide suitable casing cover protect analyzer from wind, rain, etc. CODE SYMBOLS Single-component analyzer Description measurable components Single component Measurable component Measuring range (1st range) (Note 1000 2000 2500 5000 100% Others Power supply, Piping connection 100V 50Hz 100V 60Hz 115V 60Hz 220V 50Hz 100V 50Hz 100V 60Hz 115V 60Hz 220V 50Hz 240V 50Hz 240V 50Hz Structure Table type inch rack mounting type Panel mounting type Output signal (Output 1/2) (Notes 20mA Optional function None With auto-calibration Optional function None With remote range, range identification remote output hold Measuring range (2nd range) (Note None 1000 2000 2500 5000 100% Others Adjustment Standard carburizing furnace Others (Note Paint Fuji standard standard specifications standard Notes Refer measurable range combined table Output signal provided simultaneously 100mV, 10mV available request adviced components sample Dual-component analyzer RH2G Description measurable components Dual component RH2G Description Measuring range (1st comp. range) None 100% Others Measuring range (2nd comp. range) None 1000 2000 5000 100% Others Measurable component CO2/CO Measuring range (1st comp. range) Note 5000 100% Others Measuring range (2nd comp. range) Note 1000 2000 5000 100% Others Power supply, Piping connection 100V 50Hz 100V 60Hz 115V 60Hz 220V 50Hz 100V 50Hz 100V 60Hz 115V 60Hz 220V 50Hz 240V 50Hz 240V 50Hz Structure Table type inch rack mounting type Panel mounting type Output signal (Output 1/2) (Notes 1V/DC 20mA Optional function None With auto-calibration Optional function None With remote range, range identification remote output hold Adjustment Standard carburizing furnace Others Paint Fuji standard standard specifications standard product conforms requirements Electromagnetic compatibility Directive 89/336/EEC detailed within technical construction file number TZ734576. applicable standards used demonstrate compliance 50081-1 1991 CLASS Conducted Radiated emissions 50082-1 1992 Radiated immunity, Note Refer measurable range combination table comp. CO2, comp. Measurable range combination table Single-component CH4) range range 1000 2000 2500 1000 2000 2500 5000 100% 5000 100% :CO2 :SO2 Impossible Also single range possible Dual-components (CO2/CO) component range component 500ppm 1000ppm 2000ppm 5000ppm range 100% 5000 100% * component CO2, component Dual-components possible Both components able have range. range range, choose Code symbols Dual-components possible only component, able have range. range range, choose Code Symbols. Impossible. FUNDAMENTAL PRINCIPLE DIAGRAM Infrared-ray light source inlet outlet Detector Synchronuous motor Measuring cell Mass flow sensor Rotary sector amplifier Input Remote range Contact output Output 20mA Operating panel Display Operation Rectifier amplifier Remote output hold Range identification signal Output during calibration OUTLINE DIAGRAM (Unit:mm) 124.5 Power switch Operating panel (Rack mounting plate) 57.2 <Front View> <Side View> Sample inlet 1/4) Sample outlet 1/4) Panel cutout dimensions case panel mounting) 126+2 External connection terminal (1st component) (2nd component) (AUTO CAL) Power terminals Purge inlet 1/4) <Rear View> CONNECTION DIAGRAM component Output component Range identification contact output (option) Remote hold input(option) Remote range input(option) Output AUTO Range identification contact output (option) Under calibration contact output Auto calibration failure contact output Remote start input (option) Zero contact output Span contact output Span contact output Output 20mA Output 20mA Remote range input(option) Fault SCOPE DELIVERY analyzer main unit test report instruction manual Power fuse panel mounting bracket ORDERING INFORMATION Analyzer type. Maximum, normal minimum concentrations sample well type content (percent volume) concomitant gas. Temperatures (maximum, normal minimum), pressure humidity sample gas. Dust conditions (mg/Nm3 particle size, characteristics, etc.) environmental conditions. Other items RELATED DEVICES sampling device Accommodating locker Standard (for calibration) Receiving instrument Caution Safety *Before using this product, sure read instruction manual advance. Head office 6-17, Sanbancho, Chiyoda-ku, Tokyo 102-0075, Japan http://www.fesys.co.jp Sales Div. International Sales Dept. No.1, Fuji-machi, Hino-city, Tokyo, 191-8502 Japan Phone: 81-42-585-6201, 6202 Fax: 81-42-585-6187 http: //www.fic-net.co.jp Information this catalog subject change without notice. Printed Japan Other recent searchesTDA7402 - TDA7402 TDA7402 Datasheet SC1211VX - SC1211VX SC1211VX Datasheet S5K437CX - S5K437CX S5K437CX Datasheet NJU6535 - NJU6535 NJU6535 Datasheet IRFY9230 - IRFY9230 IRFY9230 Datasheet CV210-1A - CV210-1A CV210-1A Datasheet 620ES050 - 620ES050 620ES050 Datasheet
Privacy Policy | Disclaimer |