The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers.    


Datasheet Search Engine   
 
Part # or Description: • 5V RS232 Driver • 2SC5066* • "Real Time Clock" • "USB connector" • "blue led" 5mm • 10 watt zener diode • 2N3055* motorola
 
Search Tip: Try entering the part number only. Include a wildcard (eg. lm317* or 1n4148*)

 

 

MAXIMUM THREE PHASE MOTOR HORSEPOWER 200V(FLC) 230V(FLC) 460V(FLC) 575


Datasheet Thumbnail

  

Download PDF



Top Searches for this datasheet



MOTOR CONTROLLER FUSE SELECTION TABLE TYPE PROTECTION VERIFIED)
MAXIMUM THREE PHASE MOTOR HORSEPOWER 200V(FLC) 230V(FLC) 460V(FLC) 575V(FLC)
PROTECTION .5(2.2) .5(1.1) .75(1.6) 1(2.1) 1.5(3.0) 2(3.4) 3(4.8) 3(4.8) 5(7.6) 5(7.6) 7.5(11.0) 7.5(11.0) 10(14.0) 15(21.0) 20(27.0) 25(34.0) 30(40.0) 40(52.0) 50(65.0) 60(77.0) 75(96.0) 100(124.0) 125(156.0) 150(180.0) 200(240.0) 250(302.0) 300(361.0)
CONTACTOR
3TF30/40 3TF30/40 3TF30/40 3TF30/40 3TF30/40 3TF30/40 3TF30/40 3TF30/40 3TF30/40 3TF30/40 3TF31/41 3TF31/41 3TF31/41 3TF32/42 3TF32/42 3TF33/43 3TF34/44 3TF46 3TF46 3TF46 3TF47 3TF48 3TF50 3TF50 31T52 31T52 3TF54 3TF54 3TF54 3TF56 3TF56
3UA5000-1A 3UA5000-1A 3UA5000-1C 3UA5000-1D 3UA5000-1E 3UA5000-1F 3UA5000-1F 3UA5000-1G 3UA5000-1H 3UA5000-1J 3UA5000-1J 3UA5000-1K 3UA5000-2S 3UA5200-2A 3UA5200-2B 3UA5200-2C 3UA5500-2D 3UA5800-2E 3UA5800-2F 3UA5800-2T 3UA5800-2V 3UA5800-8W 3UA6000-2X 3UA6000-3J 3UA6200-3L 3UA6200-3L 3UA6600-3B 3UA6600-3C 3UA6600-3D 3UA6600-3D 3UA6600-3E
LPN/LPS LP-CC CLASS CLASS CLASS
2.25 2.25
TYPE PROTECTION BUSSMANN/ SIEMENS
.5(2.5) .75(3.7) 1(4.8) 1(4.8) 1.5(6.9) 2(7.8) 3(11.0) 3(11.0)
.75(3.2) 1(4.2) 1.5(6.0) 2(6.8) 3(9.6) 3(9.6)
5(15.2) 5(17.5) 7.5(25.3) 10(32.2) 7.5(22.0) 10(28.0) 15(42.0) 20(54.0) 25(68.0) 30(80.0) 40(104.0) 50(130.0) 60(154.0)
Maximum ratings sized based maximum tested value that offers Type protection, maximum allowed 1996/1999 NEC®, whichever lower. Refer Bussmann Bulletin SPD, "Electrical Protection Handbook" more information Motor Circuit Protection.
15(48.3) 20(62.1) 25(78.2) 30(92.0) 40(120.0) 50(150.0)
75(221.0) 75(221.0) 100(285.2) 125(359.0)
75(192.0) 100(248.0) 125(312.0) 150(360.0)
12-28-98 SB98107
Rev.
Form T2-S-BOTH Page #8112
MOTOR CONTROLLER FUSE SELECTION TABLE TYPE PROTECTION VERIFIED)
MAXIMUM THREE PHASE MOTOR HORSEPOWER 200V(FLC) 230V(FLC) 460V(FLC) 575V(FLC)
PROTECTION .5(2.2) .5(1.1) .75(1.6) 1(2.1) 1.5(3.0) 2(3.4)
STARTER
SXLA SXLA SXLA SXLA SXLA SXLA SXLA SXLB SXLA SXLB SXLB SXLB SXLB SXLC SXLC SXLC SXLC SXLD SXLC SXLD SXLD SXLD SXLE SXLE SXLE SXLE SXLF SXLE SXLF SXLF SXLF SXLG SXLG SXLG SXLG SXLG SXLG
3UA5000-1A 3UA5000-1A 3UA5000-1C 3UA5000-1D 3UA5000-1E 3UA5000-1F 3UA5000-1G 3UA5400-1G 3UA5000-1H 3UA5400-1H 3UA5400-1J 3UA5400-1K 3UA5400-1K 3UA5400-1K 3UA5400-2A 3UA5400-2B 3UA5400-2C 3UA5800-2C 3UA5400-2D 3UA5800-2D 3UA5800-2E 3UA5800-2F 3UA5800-2F 3UA5800-2T 3UA5800-2V 3UA5800-2V 3UA6200-2W 3UA5800-8W 3UA6200-2X 3UA6200-3H 3UA6200-3J 3UA6600-3B 3UA6600-3C 3UA6600-3C 3UA6600-3C 3UA6600-3D 3UA6600-3D
LPN/LPS LP-CC CLASS CLASS CLASS
2.25 2.25
TYPE PROTECTION BUSSMANN/ SIEMENS
.5(2.5) .75(3.7) 1(4.8)
.75(3.2) 1(4.2) 1.5(6.0)
3(4.8) 1.5(6.9) 2(6.8) 2(7.8) 3(9.6) 3(11.0) 5(7.6)
NEMA
5(17.5) 5(15.2) 7.5(22.0)
7.5(11.0) 10(14.0)
15(21.0)
Maximum ratings sized based maximum tested value that offers Type protection, maximum allowed 1996/1999 NEC®, whichever lower. Refer Bussmann Bulletin SPD, "Electrical Protection Handbook" more information Motor Circuit Protection.
7.5(25.3) 10(28.0) 10(32.2) 15(42.0) 15(48.3) 20(62.1) 20(54.0) 25(68.0) 60(77.0) 25(78.2) 30(92.0) 40(120.0) 50(150.0) 60(177.0) 30(80.0) 75(96.0) 40(104.0) 50(130.0) 60(154.0) 100(124.0) 125(156.0) 150(180.0) 75(192.0) 75(221.0) 100(248.0) 200(240.0) 30(40.0) 40(52.0) 50(65.0) 20(27.0) 25(34.0)
12-28-98 SB98107
Rev.
only controlled copy this document electronic read-only version located Bussmann Network Drive. other copies this document definition uncontrolled. This bulletin intended clearly present comprehensive product data provide technical information that will help user with design applications. Bussmann reserves right, without notice, change design construction products discontinue limit distribution products. Bussmann also reserves right change update, without notice, technical information contained this bulletin. Once product been selected, should tested user possible applications.
Form T2-S-BOTH Page #8112

Other recent searches


XPS-43100WG - XPS-43100WG   XPS-43100WG Datasheet
TMS320C62x - TMS320C62x   TMS320C62x Datasheet
SL0902A - SL0902A   SL0902A Datasheet
SIP13HJ - SIP13HJ   SIP13HJ Datasheet
MB86687A - MB86687A   MB86687A Datasheet
MAXQ3120 - MAXQ3120   MAXQ3120 Datasheet
HC-49 - HC-49   HC-49 Datasheet
U-GULL - U-GULL   U-GULL Datasheet
HC-49 - HC-49   HC-49 Datasheet
U-SMD - U-SMD   U-SMD Datasheet
CAP200 - CAP200   CAP200 Datasheet
BU2727DF - BU2727DF   BU2727DF Datasheet

 

Privacy Policy | Disclaimer
© 2012 Datasheet Archive