The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers.    


Datasheet Search Engine   
 
Part # or Description: • 5V RS232 Driver • 2SC5066* • "Real Time Clock" • "USB connector" • "blue led" 5mm • 10 watt zener diode • 2N3055* motorola
 
Search Tip: Try entering the part number only. Include a wildcard (eg. lm317* or 1n4148*)

 

 

Jumo Instrument Ltd. Temple Bank, Riverway Harlow, Essex CM20 Phone (0


Datasheet Thumbnail

  

Download PDF



Top Searches for this datasheet



Juchheim GmbH
Jumo Instrument Ltd. Temple Bank, Riverway Harlow, Essex CM20 Phone (01279) (01279)
Jumo Process Control Inc. Chase Coatesville, 19320 Phone 8002 JUMO 8009
Data Sheet 40.4381
Page
Pressure transmitter JUMO dTRANS
Type 404381 Application
Pressure transmitters used measure relative (gauge) absolute pressures liquids gases. measuring device pressure transmitter piezo-resistive thin-film strain gauge. measured value pressure digitised made available further processing "CANopen" serial protocol (CAN slave). pressure transmitter provides following functions: conversion measured signal with resolution 0.5% accuracy Output measured value format (PDO) IEEE-float format (SDO) Adjustable scaling measured value unit Filtering measured value, damping, adjustable filter time constant Measurement output only change pressure (trigger) adjustable delta value Limit monitoring measurement against freely adjustable limit values Out-of-limit condition initiates high-priority alarm (emergency telegram) Defined response error sensor fault, electronics failure, CAN-bus failure Setting CAN-module baud rate either switch software (parameters CAN-bus) settings made using standard CANopen software tools.
Repeatability 0.1% full scale Response time msec
Technical data
Reference conditions 770/5.3 Measurement ranges ordering details Overload limits ranges (but max. bar) ranges ranges Bursting pressure ranges (but max. bar) ranges ranges ranges resolution measured value Zero offset (adjustment accuracy) 0.3% max. full scale Thermal hysteresis 0.5% max. full scale compensated temperature range) max. ranges mbar mbar mbar Ambient temperature error range +100°C (compensated temperature range) ranges mbar zero: 0.02%/°C typical, 0.04% max. span: 0.02%/°C typical, 0.04%/°C max. ranges from mbar zero: 0.01%/°C typical, 0.03%/°C max. span: 0.01%/°C typical, 0.03%/°C max. Deviation from characteristic 0.5% full scale (limit point adjustment) Hysteresis 0.1% full scale
Stability year 0.5% full scale (for nominal range under reference conditions) Supply max. current consumption approx. CAN-bus electronics pressure transmitter electrically isolated. Cabling screened 5-core cable. systems with more than instruments, instruments connected parallel. cable must continuous loop. Cable termination cable termination resistor. Permitted ambient temperature +85°C Storage temperature +85°C Permitted temperature medium +120°C Electromagnetic compatibility electrostatic discharge: 1000-4-2 61000-4-2 contact; discharge; contact discharge NAMUR Electromagnetic fields: 1000-4-3 61000-4-3
full scale
full scale full scale full scale
full scale full scale full scale
Parts contact with fluid/gas standard: steel, Mat. Ref. 1.4571 1.4435 ranges above bar, Mat. Ref. 1.4571 1.4542 Output CANopen protocol 7.99 00369065
JUCHHEIM GmbH 36035 Fulda, Germany
Data Sheet 40.4381
Page
frequency range 1000 MHz, test field strength V/m, kHz) 50204 MHz, V/m, (200 (The output signal pressure transmitter remains within error limit ±0.5% when subject disturbance) Transient disturbance (burst): 1000-4-4 61000-4-4 minute NAMUR; minutes capacitive coupling (The output signal pressure transmitter exceed error limit ±1.0% max. when subject disturbance) Immunity voltage pulses (surge): 1000-4-5 61000-4-5 ±500 symmetrical (The output signal pressure transmitter exceed error limit when subject disturbance. instrument permanently damaged destroyed, does lose measuring characteristics.) Immunity conductor-borne interference induced high-frequency fields: 1000-4-6 50141 frequency range 150kHz MHz, test voltage kHz) frequency range 9kHz NAMUR (The output signal pressure transmitter remains within error limit ±1.0% when subject disturbance). pressure transmitter fulfills requirements 082-2 mark) industrial areas. Interference emission 55011, Class measurement distance frequency range 030-0230 MHz, dBµV/m 230-1000 MHz, dBµV/m quasi-peak value Mechanical shock msec Mechanical vibration max. 2000 Nominal position upright vertical (pressure connection below); operating position unrestricted Protection IP65 Housing steel, Mat. Ref. 1.4301 polycarbonate Insulation resistance Breakdown strength (electrical connection housing) Veff
Pressure connection ordering details; other connections special order Weight
CAN-bus
Protocol CANopen slave 301) Profile Analogue input module 401) Baud rate kbaud Mbaud Module-ID 1-127 Emergency Node guarding Operation project planning parameters accessible CANopen object directory (EDS) using standard CANopen software tools baud rate module-ID also switches
Block diagram
Functions
analogue signal from pressure cell digitised with resolution (1). pressure signal digitally calibrated factory. (2). Undesirable signal fluctuations suppressed adjustable filter time constant (3). output signal pressure transmitter measurement unit range) (4). event-controlled signal output possible trigger (5). trigger reacts following adjustable criteria: Delta: adjustable change pressure (Limit comparator): infringement adjustable upper lower limit Sensor test: pressure cell fault "Limit comparator" "Sensor test" signals trigger high-priority emergency telegram.
7.99 00366791
JUCHHEIM GmbH 36035 Fulda, Germany
Data Sheet 40.4381
Page
Electrical connection
Connection Supply Output CANopen VCAN_GND CAN_H CAN_L Caution: Earth instrument pressure connection! CAN-bus electronics pressure transmitter electrically isolated.
Round connector
5-pole 947-5-2 Plug Socket
Dimensions
7.99 00366791
JUCHHEIM GmbH 36035 Fulda, Germany
Data Sheet 40.4381
Page
Ordering details
Basic type 404381 JUMO dTRANS pressure transmitter with sensor element piezo-resistive thin-film technology Input 0.25 gauge pressure gauge pressure gauge pressure gauge pressure gauge pressure gauge pressure gauge pressure gauge pressure gauge pressure gauge pressure gauge pressure gauge pressure gauge pressure gauge pressure gauge pressure gauge pressure gauge pressure gauge pressure absolute pressure absolute pressure absolute pressure absolute pressure absolute pressure absolute pressure absolute pressure absolute pressure absolute pressure special range Output CANopen (digital) Process connection pipe pressure connection pipe pressure connection 1/4-18 pressure connection 1/2-14 pressure connection pipe pressure connection 3852 pipe pressure connection 3852 7/16-20 pressure connection Material process connection stainless steel Electrical connection round connector 947-5-2 Preis 396,00
0,00 0,00 0,00 0,00 0,00 0,00 0,00 0,00 0,00 0,00 0,00 0,00 30,00 30,00 30,00 30,00 30,00 30,00 0,00 0,00 0,00 0,00 0,00 0,00 0,00 0,00 0,00
24,00 0,00 0,00 7,50 7,50 9,60 9,60 9,60 0,00 0,00
404381
Ordering code
Preis
7.99 00366791

Other recent searches


T1929N - T1929N   T1929N Datasheet
S380F - S380F   S380F Datasheet
MJH10012 - MJH10012   MJH10012 Datasheet
LTC1594L - LTC1594L   LTC1594L Datasheet
LTC1598L - LTC1598L   LTC1598L Datasheet
CWR09 - CWR09   CWR09 Datasheet
CWR19 - CWR19   CWR19 Datasheet
CWR29 - CWR29   CWR29 Datasheet

 

Privacy Policy | Disclaimer
© 2012 Datasheet Archive