| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
Series Recognized Certified Approved EDL4C/EHL4C EDL1S/EHL1S
Top Searches for this datasheetCORCOM Product Guide Power Entry Module with Power Line Filter General Medical Applications Series Recognized Certified Approved EDL4C/EHL4C EDL1S/EHL1S Series series power entry modules compact units that combine multi-function power entry module high performance filtering capabilities. They available with either four-voltage selector DPST on/off switch. Both variations specified with North American European fusing capabilities available either flange snap-in mounting. These filters recognized, certified, approved. series modules offer choice filters general medical applications. Models filter general purpose applications where line-to-line line-to-ground noise must controlled. filter designed meet very leakage requirements portable equipment. They available three current ratings. Models This medical filter provides susceptibility protection without leakage current associated with line-to-ground capacitors. Designed allow equipment meet UL544 patient care non-patient care equipment, filter maximum leakage current Appendix more information medical applications standards. Note: When using models with connector, remember that leakage current companion line cord, GA400, more significant than that filter which disqualify this line cord from patient care applications. Voltage Selection change selected voltage: disconnect power cord; open cover using small blade screwdriver similar tool; insert tool into voltage selection slot remove wheel from unit; select desired voltage; replace wheel into unit close cover, making sure selected voltage appears connector window. Note: models have North American dual European fusing capability available either flange snap-in mounting. Voltage selection slot 4-Voltage selection wheel Fuseholder Cover Catalog 1654001 Revised 05-07 Dimensions inches millimeters unless otherwise specified. Values italics metric equivalents. Dimensions shown reference purposes only. Specifications subject change. Cust. Svc.: 1-800-468-2023 CORCOM Prods: 1-847-680-7400 Germany: 49-89-6089-0 www.corcom.com www.tycoelectronics.com CORCOM Product Guide Power Entry Module with Power Line Filter General Medical Applications (Continued) Series Electrical Schematics Models (with switch) Note Note On/Off (1a) (2a) Specifications Maximum leakage current, each line-to-ground: Models Models 0.25 0.50 Neutral Ground Cutomer Transformer Primaries @120 @250 Hipot rating (one minute): line-to-ground line-to-line Operating frequency: Operating voltages: Suffix (fixed): Suffix (selectable): Rated current: 2EDL 2EHL 4EDL 4EHL 6EL, 6EDL 6EHL Switch: Device 1500 1450 1500 1450 Power Entry Modules 50/60 Max. 100, 120, 220, Models (with 4-voltage selection) Cutomer 120V 100V 220V 240V Transformer Primaries 120V Note Note On/Off 100V Ground Neutral Double-insulated, rated 10,000 operations full load. inrush capability. Accepts .25" 1.25" fuse fuses [2.79] except switch .187 [4.8] switch Fuse (not included): Models (with switch) Note On/Off (1a) (2a) Neutral Ground Note Customer Transformer Primaries Terminals: Minimum insertion loss Device Models (with 4-voltage selection) 120V 100V 220V 240V Customer Transformer Primaries 120V Line-to-ground circuit Current Frequency-MHz Rating Models Models Line-to-line circuit Note Note On/Off 100V Ground Neutral Current Rating Models Models Frequency-MHz Note Provision dual European style fusing. Note On/Off switch present only with suffix. Resistor location reference only. Catalog 1654001 Revised 05-07 Dimensions inches millimeters unless otherwise specified. Values italics metric equivalents. Dimensions shown reference purposes only. Specifications subject change. Cust. Svc.: 1-800-468-2023 CORCOM Prods: 1-847-680-7400 Germany: 49-89-6089-0 www.corcom.com www.tycoelectronics.com CORCOM Product Guide Power Entry Module with Power Line Filter General Medical Applications (Continued) Flange mounted version Series Case Styles Unfiltered Models Flange Models Case Styles Filtered Models Flange Models Side View .221 5.61 1.52 .221 5.61 Side View 2.201* 55.91 .020 .508 1.122* 28.50 1.575 40.00 2.213* 56.21 Snap-in version Snap-In Models +.008 -.00 +.203 -.00 Back View Recommended Panel Cutout Typical dimensions: Mounting Holes: .126 [3.20 Dia. backplate terminals: .110 [2.79 terminals, except switch. Switch terminals .187 [4.765 Note: Snap-in models allow front mounting only. Snap-In Models .221 5.61 Side View Note: Metric fuse models have additional jumper from filter-to-module. Case Dimensions Side View .221 5.61 1.52 Part Flange Unfiltered Snap-in Unfiltered Flange Filtered Snap-in Filtered (max) ±.015 ±.381 (max) (max) (max) (max) 2.14 54.36 2.14 54.36 2.14 54.36 2.14 54.36 1.66 1.11 42.16 28.19 1.66 1.11 42.16 28.19 2.01 1.11 51.05 28.19 2.01 1.11 51.05 28.19 2.201* 55.91 2.213* 56.21 1.98 1.575 50.29 40.0 58.42 1.28 32.51 58.42 1.98 1.575 50.29 40.0 58.42 1.28 32.51 58.42 .020 .508 1.122* 28.50 +.008 -.00 +.203 -.00 Back View Recommended Panel Cutout panel thickness .031-.079 [0.8-2.0] panel thickness .083-.126 [2.1-3.2] snap-in application, 1.22 [28.5] sides cutout must have [.508] radius installation side. backplate terminals: .110 [2.79] terminals, except switch. Switch terminals .187 [4.75] Note: Snap-in models allow front mounting only. Catalog 1654001 Revised 05-07 Dimensions inches millimeters unless otherwise specified. Values italics metric equivalents. Dimensions shown reference purposes only. Specifications subject change. Cust. Svc.: 1-800-468-2023 CORCOM Prods: 1-847-680-7400 Germany: 49-89-6089-0 www.corcom.com www.tycoelectronics.com CORCOM Product Guide Power Entry Module with Power Line Filter General Medical Applications (Continued) Series UNFILTERED MODELS Part Number 6EL1S 6EL1SC 6EL1SM 6EL1SCM 6EL4 6EL4C 6EL4M 6EL4CM Current Rating Available Voltage Selection Position DPST On/Off Switch Mounting Style Flange Snap-In Flange Snap-In Flange Snap-In Flange Snap-in Fuseholder Type North American North American Metric Metric North American North American Metric Metric Power Entry Modules FILTERED MODELS Part Number 2EDL1S 2EDL1SC 2EDL1SM 2EDL1SCM 2EDL4 2EDL4C 2EDL4M 2EDL4CM 4EDL1S 4EDL1SC 4EDL1SM 4EDL1SCM 4EDL4 4EDL4C 4EDL4M 4EDL4CM 6EDL1S 6EDL1SC 6EDL1SM 6EDL1SCM 6EDL4 6EDL4C 6EDL4M 6EDL4CM 6EHL1S 6EHL1SC 6EHL1SM 6EHL1SCM 6EHL4 6EHL4C 6EHL4M 6EHL4CM Includes DPST switch Filter Type Linear Linear Linear Linear Linear Linear Linear Linear Linear Linear Linear Linear Linear Linear Linear Linear Linear Linear Linear Linear Linear Linear Linear Linear Medical Medical Medical Medical Medical Medical Medical Medical Current Rating Available Voltage Selection Position DPST On/Off Switch Mounting Style Flange Snap-In Flange Snap-In Flange Snap-In Flange Snap-in Flange Snap-in Flange Snap-in Flange Snap-in Flange Snap-in Flange Flange Flange Snap-in Flange Snap-in Flange Snap-in Flange Snap-in Flange Snap-in Flange Snap-in Flange Snap-in Fuseholder Type North American North American Metric Metric North American North American Metric Metric North American North American Metric Metric North American North American Metric Metric North American North American Metric Metric North American North American Metric Metric North American North American Metric Metric North American North American Metric Metric Catalog 1654001 Revised 05-07 Dimensions inches millimeters unless otherwise specified. Values italics metric equivalents. Dimensions shown reference purposes only. Specifications subject change. Cust. Svc.: 1-800-468-2023 CORCOM Prods: 1-847-680-7400 Germany: 49-89-6089-0 www.corcom.com www.tycoelectronics.com Other recent searchesXC4000XL-1 - XC4000XL-1 XC4000XL-1 Datasheet SR302 - SR302 SR302 Datasheet SR310 - SR310 SR310 Datasheet SCCS039A - SCCS039A SCCS039A Datasheet M58BW016DB - M58BW016DB M58BW016DB Datasheet M58BW016DT - M58BW016DT M58BW016DT Datasheet M58BW016FT - M58BW016FT M58BW016FT Datasheet M58BW016FB - M58BW016FB M58BW016FB Datasheet M58BW016DT - M58BW016DT M58BW016DT Datasheet M58BW016FT - M58BW016FT M58BW016FT Datasheet LT1970 - LT1970 LT1970 Datasheet CBT6800 - CBT6800 CBT6800 Datasheet BD238 - BD238 BD238 Datasheet ADS1100 - ADS1100 ADS1100 Datasheet MSP430F413 - MSP430F413 MSP430F413 Datasheet
Privacy Policy | Disclaimer |