LPT25 Series
Watts
Total Power: Input Voltage: Outputs: Watts 300VDC Triple
Rev. 04.13.06 LPT25 Series
RoHS
Electrical Specifications
Special Features
Universal input footprint Less than high Remote sense main output Terminal block option (-T) Built-in filter output ripple Adjustable main output Overvoltage protection Overload protection switching frequency LPX40 enclosure available
Input
Input range Frequency Inrush current Input current Efficiency 85-264 120-300 47-440 <15A peak 115VAC; <30A peak 230VAC, cold start 25°C max. (RMS) typical full load Class conducted; CISPR Class conducted EN55022 Class conducted; 0878 Class conducted <0.5 50/60 input
Safety ground leakage current
Output
Maximum Power Cross regulation Adjustment range Hold-up time Overload protection Overvoltage protection Remote sense convection; with 30CFW forced output outputs +10% minimum load, nominal line Short circuit protection outputs. Case overload protected 110% 145% above peak rating main output Compensates lead drop min. Will operate without remote sense connected. Reverse connection protected.
Safety
0805 EN60950 (IEC950) 11774-3336-1241 (LC#84936) UL1950 E132002 22.2-234 Level LR53982C NEMKO 60950/EMKO-TUE P95100411 (74-sec) Certificate report 1569, 1570, 1571, 1572 Mark (LVD)
Environmental Specifications
Operating temperature: Electromagnetic susceptibility: Humidity: Vibration: 50°C ambient derate each output 2.5% degree from 70°C, -20°C start Designed meet 801, Level Operating; non-condensing Three orthogonal axes, sweep oct/min, min. dwell four major resonances 0.75G peak operational -40° 85°C ±.04% >550,000 hours full load 25°C ambient conditions
Rev. 04.13.06 LPT25 Series
Storage temperature: Temperature coefficient: MTBF demonstrated:
Ordering Information
Model Number LPT22(-T) Output Voltage -12V -12V -15V Minimum Load 0.3A 0.1A 0.4A 0.3A 0.1A 0.3A 0.1A Maximum Load with Convnection cooling 1.5A 0.5A 0.5A 0.5A 1.5A 0.5A 1.5A 0.5A Maximum Load with 30CFM Forced 0.7A 0.7A 0.7A 0.7A 0.7A Peak Load1 Regulation2 Ripple (PARD)3 50mV 120mV 120mV 50mV 120mV 120mV 50mV 120mV 50mV 50mV 150mV 150mV
LPT23(-T)
LPT24(-T)
LPT25(-T)
Peak current lasting seconds with maximum duty cycle. 25°C including initial tolerance, line voltage, load currents output voltages adjusted factory settings. Peak-to-peak with bandwidth parallel with capacitor rated line voltage load ranges. Minimum Loads required. (-T) indicates Terminal Block option input output (instead Molex type).
Power Derating Curve
Forced Cooling Output Power (Watts)
Natural Convection Cooling
12.5W
10°C 20°C 30°C 40°C 50°C 60°C 70°C Ambient Temperature
Mechanical Drawing
5.00" (127)
Astec Power
5810 Allen Carlsbad, 92008 Telephone: 4600 Facsimile: 0698 Technical Support: ASTEC 2752 Waterfront Business Park Merry Hill, Dudley West Midlands, United Kingdom Telephone: 1384 Facsimile: 1384 Units 2111-2116, Level Tower Metroplaza 223, Hing Fong Road Kwai Fong, Territories Hong Kong Telephone: +852 2437 9662 Facsimile: +852 2402 4426
Rev. 04.13.06 LPT25 Series
0.22" (5.6)
4.55" (115.6)
SK201
3.00" (76.2) 2.55" (64.8)
Remote Sense Connector Voltage Adj.
0.15" places)
global contact, visit:
www.astecpower.com technicalsupport@astec.com
1.14" (29)
While every precaution been taken ensure accuracy completeness this literature, Astec Power assumes responsibility, disclaims liability damages resulting from this information errors omissions.
0.12"
Printed
Assignments
Connector LPT22 SK1-1 SK1-3 SK2-1 SK2- SK2- SK2-4 SK2-5 SK2-6 SK201-1 SK201-2 Line Neutral +12V Common Common -12V +Sense -Sense LPT23 Line Neutral +12V Common Common -12V +Sense -Sense LPT24 Line Neutral +12V Common Common +Sense -Sense LPT25 Line Neutral +15V Common Common -15V +Sense -Sense
Mating Connectors
Input: Molex 09-50-8031 (USA) required (-T) option 09-91-0300 (UK) PINS: 08-52-0113
Emerson Network Power. global leader enabling business-critical continuity. Power Connectivity Power Embedded Power Inbound Power Integrated Cabinet Solutions Outside Plant Precision Cooling Site Monitoring Services EmersonNetworkPower.
Emerson Network Power Emerson Network Power logo trademarks service marks Emerson Electric ©2006 Emerson Electric
Outputs: Molex 09-50-8061 (USA) required (-T) option 09-91-0600 (UK) PINS: 08-52-0113 Remote Molex 22-01-2025 PINS: 08-52-0123 Sense: Astec Connector #70-841-006, includes above Specifications subject change without notice. dimensions inches (mm), tolerance ±0.02" (±0.5mm) Mounting holes should grounded purposes. Mounting hole safety ground connection. Specifications convection rating factory settings input, 25°C unless otherwise stated. Warranty: year Weight: 0.5lbs/0.23kg

Other recent searches


USB3250 - USB3250   USB3250 Datasheet
TMDA05-18 - TMDA05-18   TMDA05-18 Datasheet
LM3S1N16 - LM3S1N16   LM3S1N16 Datasheet
ISL88731C - ISL88731C   ISL88731C Datasheet
FDS6690AS - FDS6690AS   FDS6690AS Datasheet
BCW71 - BCW71   BCW71 Datasheet
BCW72 - BCW72   BCW72 Datasheet
BCM8501 - BCM8501   BCM8501 Datasheet
AN5369 - AN5369   AN5369 Datasheet
AN5369-2 - AN5369-2   AN5369-2 Datasheet

 

Privacy Policy | Disclaimer
© 2012 Datasheet Archive