| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
GP1FD300RK Thin type (4.2mm) fiber optic receiver Compact (adopti
Top Searches for this datasheetGP1FD300RK GP1FD300RK Thin type (4.2mm) fiber optic receiver Compact (adoption small jack mini plug) C6560 Both optical electrical signal distinguished received voltage operation (VCC 3.6V) High speed data transmission (Signal transmission speed MAX, 8Mbps (NRZ signal)) Thin Voltage Operation Type Optical Mini-jack Digital Audio Equipment Outline Dimensions 7±0.2 (Unit Applications players Portable players (Optic receiver part) 4.2±0.1 8.5±0.2 3.6±0.05 12.2 (R0.2) 17+0.2 -0.1 (Ta=25°C) Unit 14.425 Output current times less) Absolute Maximum Ratings(Jack) Parameter Symbol Rating D.C. 12V, Total power dissipation Ptot Operating temperature Topr Tstg Storage temperature Tsol Soldering temperature Viso A.C. 500V Isolation voltage times less) 1min Unit Internal equivalent circuit 12.2 Parameter Supply voltage Operating temperature Storage temperature Soldering temperature Symbol Rating -0.5 +7.0 Topr Tstg Tsol (source current) (sink current) 3-0.4 2-1.2-0.1 C0.15 (R0.25) 0.5-0.1 Absolute Maximum Ratings (Photoelectric conversion element) 5-0.1 +0.3 0.25-0.1 2-1.4 Jack terminal Jack body Device terminal Jack terminal configuration Vout OPIC light detector Unspecified tolerance ±0.3mm Reference dimensions "OPIC"(Optical trademark SHARP Corporation. OPIC consists light-detecting element signalprocessing circuit integrated onto signal chip. Notice absence confirmation device specification sheets, SHARP takes responsibility defects that occur equipment using SHARP devices shown catalogs, data books, etc. Contact SHARP order obtain latest device specification sheets before using SHARP device. Internet Internet address Electronic Components Group http://www.sharp.co.jp/ecg/ GP1FD300RK Recommended Operating Conditions Parameter Symbol MIN. TYP. MAX. Unit Operating supply voltage Operating transfer rate Mbps Receiver input optical power level -24.0 -14.5 Electro-optical Characteristics Parameter Peak sensitivity wavelength Dissipation current High level output voltage level output voltage Rise time Fall time High delay time High delay time Pulse width distortion Jitter Symbol tpLH tpHL Conditions Refer Fig.1 Refer Fig.2 Refer Fig.2 Refer Fig.2 Refer Fig.2 Refer Fig.2 Refer Fig.2 Refer Fig.2 Refer Fig.3, -14.5dBm Refer Fig.p3, -24dBm MIN. TYP. (Ta=25°C, Vcc=3.0V) MAX. Unit Mechanical Electrical Characteristics(Jack) Parameter Insertion force, with drawal force Contact resistance Isolation resistance Symbol Rcon Riso Conditions D.C. 500V, 1min. MIN. TYP. MAX. Unit Note) This jack designed applicable compact single head plug (JIS C6560). Measuring method insertion force withdrawal force. Insertion withdrawal force shall measured after inserting withdrawing times using C6560 standard plug test. Measuring method contact resistance. measures 100mA less 1000Hz condition inserting C6560 standard plug test which movable contact terminal make contacts described. Fig.1 Dissipation Current Supply voltage Optical output coupling with fiber Standard transmitter input signal Input conditions VCC=3.0±0.05V PC=-14.5dBm 6Mbps NRZ, Duty 3Mbps biphase mark PRBS signal Fiber optic cable Standard transmitter Ammeter GP1FD300RK Unit measured Vout Measuring method Measured ammeter average amperage) Input GP1FD300RK Fig.2 Measuring Method Output Voltage Pulse Response Fiber optic cable Standard transmitter Input GP1FD300RK Unit measured Vout 6Mbps NRZ, Duty Tektronix 7834 7934 type Oscilloscope Test item Test item High pulse delay time High pulse delay time Rise time Fall time Pulse width distortion tw=tPHL-tPLH High level output voltage level output voltage Notes Symbol tPLH tPHL Standard transmitter Input signal (CH1) GP1FD300RK Output signal (CH2) VCC=3.0±0.05V (State operating) fiber coupling light output -14.5dBm/-24.0dBm. probe oscilloscope must more than less than 10pF. output (H/L level) GP1FD300RK fixed constantly when receives modulating light (including light, input light) less than 0.1Mbps. tPLH tPHL GP1FD300RK Fig.3 Measuring Method Jitter Fiber optic cable Standard transmitter GP1FD300RK Unit measured Vout Oscilloscope Input Tektronix7834 7934 type Trigger Storage mode Sweep AUTO/NORM Input signal 3Mbps biphase PRBS signal Test item Test item Symbol Jitter Jitter Test condition trigger rise input signal measure jitter rise output trigger fall input signal measure jitter fall output Input signal Notes fiber coupling light output -14.5dBm/-24.0dBm. waveform write time shall seconds. allow waveform distorted increasing brightness much. VCC=3.0±0.05V (State operating) probe oscilloscope must more than less than 10pF. GP1FD300RK output Application Circuits NOTICE qThe circuit application examples this publication provided explain representative applications SHARP devices intended guarantee circuit design license intellectual property rights. SHARP takes responsibility problems related intellectual property right third party resulting from SHARP's devices. qContact SHARP order obtain latest device specification sheets before using SHARP device. SHARP reserves right make changes specifications, characteristics, data, materials, structure, other contents described herein time without notice order improve design reliability. Manufacturing locations also subject change without notice. qObserve following points when using devices this publication. SHARP takes responsibility damage caused improper devices which does meet conditions absolute maximum ratings used specified relevant specification sheet meet following conditions: devices this publication designed general electronic equipment designs such Personal computers Office automation equipment Telecommunication equipment [terminal] Test measurement equipment Industrial control Audio visual equipment Consumer electronics (ii)Measures such fail-safe function redundant design should taken ensure reliability safety when SHARP devices used connection with equipment that requires higher reliability such Transportation control safety equipment (i.e., aircraft, trains, automobiles, etc.) Traffic signals leakage sensor breakers Alarm equipment Various safety devices, etc. (iii)SHARP devices shall used connection with equipment that requires extremely high level reliability safety such Space applications Telecommunication equipment [trunk lines] Nuclear power control equipment Medical other life support equipment (e.g., scuba). qContact SHARP representative advance when intending SHARP devices "specific" applications other than those recommended SHARP when unclear which category mentioned above controls intended use. SHARP devices listed this publication fall within scope strategic products described Foreign Exchange Foreign Trade Control Japan, necessary obtain approval export such SHARP devices. qThis publication proprietary product SHARP copyrighted, with rights reserved. Under copyright laws, part this publication reproduced transmitted form means, electronic mechanical, purpose, whole part, without express written permission SHARP. Express written permission also required before this publication made third party. qContact consult with SHARP representative there questions about contents this publication. Other recent searchesVDE0106 - VDE0106 VDE0106 Datasheet P100 - P100 P100 Datasheet IEC60664-1 - IEC60664-1 IEC60664-1 Datasheet VDE0110 - VDE0110 VDE0110 Datasheet TPCF8302 - TPCF8302 TPCF8302 Datasheet SPS-53160G - SPS-53160G SPS-53160G Datasheet SN74AHCT573 - SN74AHCT573 SN74AHCT573 Datasheet SN54AHCT573 - SN54AHCT573 SN54AHCT573 Datasheet NT-1 - NT-1 NT-1 Datasheet NT-2 - NT-2 NT-2 Datasheet BYW80PI-200 - BYW80PI-200 BYW80PI-200 Datasheet AN1068 - AN1068 AN1068 Datasheet 2SK3525-01MR - 2SK3525-01MR 2SK3525-01MR Datasheet
Privacy Policy | Disclaimer |