| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
High Performance Level Pressure Sensor Schaevitz® P1500 Series St
Top Searches for this datasheetP1500 Series High Performance Level Pressure Sensor Schaevitz® P1500 Series Strain Gauge Pressure Transducers high grade sensors that provide highly precise measurement absolute vented gauge pressures over wide temperature ranges. Standard versions this transducer 17-4 stainless steel diaphragm sense pressure. deflection diaphragm transferred double cantilever beam force transfer rod. Strain beam, therefore, input pressure measured four foil strain gauges. all-welded construction provides high reliablility stability. Capable sensing extremely small changes applied pressure, transducers relatively insensitive vibration, altitude shock. P1500 Series available range electrical inputs outputs. Zero span potentiometers availbable special option with P1540, P1550, P1560 P1590 models. Features Applications High overload capability Operation high temperatures Shock vibration resistant wire 4-20 option: Intrinsic safety approval (Tamb=60°C), BASEFA, CENELEC EN50-020 Specifications Model 77°F (25°C) Model Number P1502/4 Input Voltage max) Current Output (F.R.O.) Full Range Output (±1%) mbar mbar mbar Impedance (ohm) Current (max) Frequency Response P1542/4 Pneumatic pressure monitoring Climate room control Vehicle brake system monitoring Military commercial aircraft P1552/4 11-18 P1562/4 18-32 P1582/4 10-36 P1592/4 4-20 4-20 Load Resist. 1300 max. Approx. mbar approx. mbar ±0.008 ±0.015 12.5 (350) (250) 11.4 (320) (220) ±0.008 ±0.015 13.2 (370) (270) 12.1 (340) (240) Combined Thermal Zero Sensitivity Shift F.R.O./°F F.R.O./°C Residual Unbalance (%FRO) Weight (gm) Cable mbar Cable mbar Connector mbar Connector mbar ±0.008 ±0.015 13.2 (370) (270) 12.1 (340) (240) ±0.008 ±0.015 13.2 (370) (270) 12.1 (340) (240) ±0.008 ±0.015 +1-0% 13.2 (370) (270) 12.1 (340) (240) ±0.008 ±0.015 13.2 (370) (270) 12.1 (340) (240) Internet: www.schaevitz.com North America Tel: 800/745-8008 Document Back: 916/431-6541 Europe Tel: (01753) 537622 Select P1500 models, when correctly installed, certified comply with Directive 89/336/EEC Generic Standards Residential, Commercial, Light Industrial Industrial Environments. P1500 Series Pressure Ranges: 0-1.5 (0-100 mbar) Accuracy: 0.25% F.R.O. Common Specifications Pressure Ranges (psi) 0-1.5; 3.0; (mbar) 0-100; 200; Pressure References Vented gauge1 Absolute Pressure Limit full range pressure. Will cause zero offset exceeding 0.05% (recoverable within hour) Burst Pressure full range pressure Pressure Media Liquids gases compatible with 17-4 17-7 stainless steel Shunt Calibration full range pressure (not fitted P1580 Series) Combined Nonlinearity, Hysteresis Nonrepeatability ±0.25% F.R.O. (BSL) Temperature Range Operable -65°F 250°F (-54°C 120°C) Compensated 32°F 212°F (0°C 100°C) Storage -65°F 300°F (-54°C 150°C) Humidity Connector Version Relative humidity Cable Version Immersible IP67 (fluid must enter ends cable) Acceleration Response 0-100 mbar ±1.0% F.R.O./g nominal 0-200 mbar ±0.5% F.R.O./g nominal 0-350 mbar ±0.4% F.R.O./g nominal Vibration Surpasses STD810C Method 514-2 Curve EUROCAE 14A/RTCA 160A Shock 1000 msec will damage sensor P1540, P1550, P1560, P1580 P1590 Series marked, when correctly installed comply with Directive 89/336/EEC Generic Standards Residential Commercial, Light Industrial Industrial environments. Note: P1580 Series when used Intrinsic Safety applications does comply with Industrial environment directive. Insulation Resistance Mohm 25°C Vented gauge units must only used dry, noncorrosive environments will breathe through cable vent tube hole 6-way receptacle. P1500 Series High Performance Level Pressure Sensor Dimensions (mm) 0.75 (19.0) 1.984 (50.4) 0.59 (15.0) 39.4 Meter) Standard Pressure Adaptor (See Table Below) (29.5) (25.4) P1502/4 3.37 (85.5) 0.59 (15.0) Connector Pressure Adaptor (See Table Below) (29.5) (25.4) P15X2/4 Adapters Thread Size 1/4" 1/4" 7/16"-20UNF-SA 1/4"-18NPT 1/4"-18NPT Code Welded 0001 0002 0003 0004 0005 0006 0009 Dimensions (mm) 0.47 (11.9) 0.46 (11.7) 0.40 (10.2) 0.56 (14.2) 0.55 (14.0) 0.39 (9.9) 0.57 (14.4) Range (100 mbar) (200 mbar) (350 mbar) Diameter (mm) 1.976 (50.19) 1.976 (50.19) 1.644 (41.75) Connector Orientation Connections Cable White Yellow Blue1,3 Violet Grey Connector2 C1,3 Excitation Excitation (-)4 Output Output (-)4 Connector Orientation shunt calibration Note: Screen connected case marked units. Screen connected case optional units (P1580). certification revokes certification. 2-wire transmitter connections (max cable length meters when I.S.) Vented gauge units must breathe through receptacle (mating connector must have vent hole) Volt P1590 Series Connected internally P1540, P1550, P1560 Series (3-wire) Shunt calibration fitted P1580 Series Internet: www.schaevitz.com North America Tel: 800/745-8008 Document Back: 916/431-6541 Europe Tel: (01753) 537622 Select P1500 models, when correctly installed, certified comply with Directive 89/336/EEC Generic Standards Residential, Commercial, Light Industrial Industrial Environments. P1500 Series Pressure Ranges: 0-1.5 (0-100 mbar) Accuracy: 0.25% F.R.O. P1592/4 Excitation Wiring P1502/4 Excitation Output Output Blue Yellow Excitation Output White Blue Output Yellow Excitation White Violet Calibration Violet Calibration Gray Grey P1582/4 Positive Negative Blue P1542/4, P1552/4 P1562/4 Excitation Output Yellow Output Blue Excitation White Order Specify transducer excitation, electrical interface, pressure port, pressure range, units, pressure reference. Example: P562-0005-200 mbar signifies pressure transducer with output operating from 18-32V, cable outlet inch-18 male pressure port, ranged mbar, with absolute pressure reference. Model Number Code Intrinsic Safety (P1580 only) Adaptor Welded Screw R.Cal Violet Calibration Grey internally connected Input/Output output output supply) output (11-18 supply) output (18-32 supply) 4-20 output (10-36 supply) output (±15 supply) Cable/Connector (Please reference selected pressure range) Range cable outlet Range connector outlet Unit mbar Pressure Reference absolute vented gauge Pressure Port female male male 7/16 male male (taper) Arsero Ermeto female female Pressure Range (Enter full scale pressure range without units) (psi) 0-1.5; 3.0; (mbar) 0-100; 200; Other recent searchesWay-0 - Way-0 Way-0 Datasheet SCA-4-15-75+ - SCA-4-15-75+ SCA-4-15-75+ Datasheet VF540 - VF540 VF540 Datasheet MC10EP56 - MC10EP56 MC10EP56 Datasheet LPV7215 - LPV7215 LPV7215 Datasheet ALR100 - ALR100 ALR100 Datasheet
Privacy Policy | Disclaimer |