2,415,919,104-BIT 33,554,432-WORD 72-BIT Synchronous DYNAMIC MH32


Datasheet Thumbnail

  

Download PDF



Top Searches for this datasheet



MH32S72BAFA -7,-8
2,415,919,104-BIT 33,554,432-WORD 72-BIT Synchronous DYNAMIC
MH32S72BAFA 33554432 word 72-bit Synchronous DRAM stacked structural module. This consist thirty-six industry standard Synchronous DRAMs TSOP. stacked structure TSOP card edge dual in-line package provides application where high densities large quantities memory required. This socket-type memory module ,suitable easy interchange addition module.
85pin
1pin
FEATURES
Type name Max. Frequency Access Time [latch mode]
94pin 95pin
10pin 11pin
MH32S72BAFA-7 MH32S72BAFA-8
100MHz 100MHz
Back side
Front side
124pin 125pin
40pin 41pin
Utilizes industry standard Synchronous DRAMs TSOP package industry standard Resister TSSOP package industry standard TSSOP package. Single 3.3V 0.3V supply Burst length 1/2/4/8/Full Page (programmable) Burst type sequential interleave (programmable) Column access random Burst Write Single Write (programmable) Auto precharge Auto bank precharge controlled Auto refresh Self refresh LVTTL Interface 4096 refresh cycles every 64ms Intel specifiation(rev. 1.0)compliant 1.2A
APPLICATION
Main memory unit computers, Microcomputer memory.
168pin
84pin
MIT-DS-0243-0.0
29.July.1998
MITSUBISHI ELECTRIC
MH32S72BAFA -7,-8
2,415,919,104-BIT 33,554,432-WORD 72-BIT Synchronous DYNAMIC
NAME DQ10 DQ11 DQ12 DQ13 DQ14 DQ15 /WE0 DQMB0 DQMB1
NAME DQMB2 DQMB3 DQ16 DQ17 DQ18 DQ19 DQ20 DQ21 DQ22 DQ23 DQ24 DQ25 DQ26 DQ27 DQ28 DQ29 DQ30 DQ31
NAME DQ32 DQ33 DQ34 DQ35 DQ36 DQ37 DQ38 DQ39 DQ40 DQ41 DQ42 DQ43 DQ44 DQ45 DQ46 DQ47 /CAS DQMB4 DQMB5 /RAS
NAME CKE0 DQMB6 DQMB7 DQ48 DQ49 DQ50 DQ51 DQ52 REGE DQ53 DQ54 DQ55 DQ56 DQ57 DQ58 DQ59 DQ60 DQ61 DQ62 DQ63
Connection
MIT-DS-0243-0.0
29.July.1998
MITSUBISHI ELECTRIC
MH32S72BAFA -7,-8
2,415,919,104-BIT 33,554,432-WORD 72-BIT Synchronous DYNAMIC
CKE0 /S0-3 DQM0-7 /RAS /CAS REGE
DQ10 DQ11 DQ12 DQ13 DQ14 DQ15 DQ16 DQ17 DQ18 DQ19 DQ20 DQ21 DQ22 DQ23 DQ24 DQ25 DQ26 DQ27 DQ28 DQ29 DQ30 DQ31 Registered Buffer
RCKE0 R/S0-3 RDQM0-7
DQ32 DQ33 DQ34 DQ35 DQ36 DQ37 DQ38 DQ39 DQ40 DQ41 DQ42 DQ43 DQ44 DQ45 DQ46 DQ47 DQ48 DQ49 DQ50 DQ51 DQ52 DQ53 DQ54 DQ55 DQ56 DQ57 DQ58 DQ59 DQ60 DQ61 DQ62 DQ63
From
RCKE0 R/S0 R/S1 R/S2 R/S3
Terminated
D0-35 D0-3,D8-12,D17 D18-21,D26-30,D35 D4-7,D13-16 D22-25,D31-34
RDQM RDQM RDQM RDQM RDQM RDQM RDQM RDQM
SERIAL D0-1,D18-19 D2-3,D8,D20-21,D26 D4-5,D22-23 D6-7,D24-25 D9-10,D27-28 D11-12,D17,D29-30,D35 D13-14,D31-32 D15-16,D33-34
MIT-DS-0243-0.0
29.July.1998
MITSUBISHI ELECTRIC
MH32S72BAFA -7,-8
2,415,919,104-BIT 33,554,432-WORD 72-BIT Synchronous DYNAMIC
FUNCTION
Input Master Clock:All other inputs referenced rising edge Clock Enable:CKE controls internal clock.When low,internal clock following cycle ceased. also used select auto self refresh. After self refresh mode started, becomes asynchronous input.Self refresh maintained long low. Chip Select: When high,any command means Operation. Combination /RAS,/CAS,/W defines basic commands. A0-11 specify Row/Column Address conjunction with BA.The Address specified A0-11.The Column Address specified A0-9.A10 also used indicate precharge option.When high read write command, auto precharge performed. When high precharge command, both banks precharged. Bank Address:BA0,1 simply BA.BA0,1 specifies bank which command applied.BA must with ACT,PRE,READ,WRITE commands
CKE0
Input
/RAS,/CAS,/W
Input Input
A0-11
Input
BA0-1 DQ0-63 CB0-7
Input
Data Data referenced rising edge Input/Output Mask/Output Disable:When DQMB high burst write.Din current cycle masked.When DQMB high burst read,Dout disabled next cycle.
DQM0-7
Input
Vdd,Vss
Power Supply Power Supply memory mounted module. Register enable:When REGE low,All control signals address buffered. (Buffer mode) When REGE high,All control address latched. (Latch mode)
REGE
Output
MIT-DS-0243-0.0
29.July.1998
MITSUBISHI ELECTRIC
MH32S72BAFA -7,-8
2,415,919,104-BIT 33,554,432-WORD 72-BIT Synchronous DYNAMIC
BASIC FUNCTIONS
MH32S72BAFA provides basic read write, bank(row)precharge,and auto self refresh. Each command defined control signals /RAS,/CAS rising edge. addition signals,/S,CKE used chip select,refresh option,and precharge option,respectively. know detailed definition commands please command truth table.
/RAS /CAS
Chip Select L=select, H=deselect Command Command Command Refresh Option @refresh command Precharge Option @precharge read/write command define basic commands
Activate(ACT) [/RAS /CAS command activates idle bank indicated Read(READ) [/RAS =H,/CAS READ command starts burst read from active bank indicated BA.First output data appears after /CAS latency. When this command,the bank deactivated after burst read(auto-precharge,READA). Write(WRITE) [/RAS /CAS WRITE command starts burst write active bank indicated Total data length written burst length. When this command, bank deactivated after burst write(auto-precharge,WRITEA). Precharge(PRE) [/RAS /CAS =H,/WE command deactivates active bank indicated This command also terminates burst read write operation. When this command, both banks deactivated(precharge all, PREA). Auto-Refresh(REFA) [/RAS =/CAS =CKE PEFA command starts auto-refresh cycle. Refresh address including bank address generated internally. After this command, banks precharged automatically.
MIT-DS-0243-0.0
29.July.1998
MITSUBISHI ELECTRIC
MH32S72BAFA -7,-8
2,415,919,104-BIT 33,554,432-WORD 72-BIT Synchronous DYNAMIC
COMMAND TRUTH TABLE
COMMAND Deselect Operation Address Entry Bank Activate Single Bank Precharge Precharge Banks Column Address Entry Write Column Address Entry Write with AutoPrecharge Column Address Entry Read Column Address Entry Read with AutoPrecharge Auto-Refresh Self-Refresh Entry Self-Refresh Exit Burst Terminate Mode Register MNEMONIC DESEL PREA WRITE /RAS /CAS BA0,1 A0-9
WRITEA
READ
READA REFA REFS REFSX TBST
H=High Level, L=Low Level, V=Valid, X=Don't Care, n=CLK cycle number NOTE: A7-A9 A0-A6 =Mode Address
MIT-DS-0243-0.0
29.July.1998
MITSUBISHI ELECTRIC
MH32S72BAFA -7,-8
2,415,919,104-BIT 33,554,432-WORD 72-BIT Synchronous DYNAMIC
FUNCTION TRUTH TABLE
Current State IDLE ACTIVE READ /RAS /CAS BA,CA,A10 BA,RA BA,A10 Op-Code, Mode-Add BA,CA,A10 BA,CA,A10 BA,RA BA,A10 Op-Code, Mode-Add BA,CA,A10 Address Command DESEL TBST PRE/PREA REFA DESEL TBST READ/READA WRITE/ WRITEA PRE/PREA REFA DESEL TBST ILLEGAL*2 Bank Active,Latch NOP*4 Auto-Refresh*5 Mode Register Set*5 Begin Read,Latch Determine Auto-Precharge Begin Write,Latch Determine Auto-Precharge Bank Active/ILLEGAL*2 Precharge/Precharge ILLEGAL ILLEGAL NOP(Continue Burst END) NOP(Continue Burst END) Terminate Burst Terminate Burst,Latch READ/READA Begin Read,Determine Auto-Precharge*3 Terminate Burst,Latch BA,CA,A10 BA,RA BA,A10 Op-Code, Mode-Add WRITE/WRITEA Begin Write,Determine AutoPrecharge*3 PRE/PREA REFA Bank Active/ILLEGAL*2 Terminate Burst,Precharge ILLEGAL ILLEGAL Action
READ/WRITE ILLEGAL*2
MIT-DS-0243-0.0
29.July.1998
MITSUBISHI ELECTRIC
MH32S72BAFA -7,-8
2,415,919,104-BIT 33,554,432-WORD 72-BIT Synchronous DYNAMIC
FUNCTION TRUTH TABLE(continued)
Current State WRITE /RAS /CAS Address BA,CA,A10 Action NOP(Continue Burst END) NOP(Continue Burst END) Terminate Burst Terminate Burst,Latch READ/READA Begin Read,Determine AutoPrecharge*3 Terminate Burst,Latch WRITE/ Begin Write,Determine AutoWRITEA Precharge*3 Bank Active/ILLEGAL*2 PRE/PREA REFA DESEL TBST READ/READA WRITE/ WRITEA PRE/PREA REFA DESEL TBST READ/READA WRITE/ WRITEA PRE/PREA REFA Terminate Burst,Precharge ILLEGAL ILLEGAL NOP(Continue Burst END) NOP(Continue Burst END) ILLEGAL ILLEGAL ILLEGAL Bank Active/ILLEGAL*2 ILLEGAL*2 ILLEGAL ILLEGAL NOP(Continue Burst END) NOP(Continue Burst END) ILLEGAL ILLEGAL ILLEGAL Bank Active/ILLEGAL*2 ILLEGAL*2 ILLEGAL ILLEGAL Command DESEL TBST
READ with AUTO PRECHARGE WRITE with AUTO PRECHARGE
BA,CA,A10 BA,RA BA,A10 Op-Code, Mode-Add BA,CA,A10 BA,CA,A10 BA,RA BA,A10 Op-Code, Mode-Add BA,CA,A10 BA,CA,A10 BA,RA BA,A10 Op-Code, Mode-Add
MIT-DS-0243-0.0
29.July.1998
MITSUBISHI ELECTRIC
MH32S72BAFA -7,-8
2,415,919,104-BIT 33,554,432-WORD 72-BIT Synchronous DYNAMIC
FUNCTION TRUTH TABLE(continued)
Current State CHARGING ACTIVATING WRITE RECOVERING /RAS /CAS BA,CA,A10 BA,RA BA,A10 Op-Code, Mode-Add BA,CA,A10 BA,RA BA,A10 Op-Code, Mode-Add BA,CA,A10 BA,RA BA,A10 Op-Code, Mode-Add Address Command DESEL TBST PRE/PREA REFA DESEL TBST PRE/PREA REFA DESEL TBST PRE/PREA REFA Action NOP(Idle after tRP) NOP(Idle after tRP) ILLEGAL*2 ILLEGAL*2 NOP*4(Idle after tRP) ILLEGAL ILLEGAL NOP(Row Active after tRCD NOP(Row Active after tRCD ILLEGAL*2 ILLEGAL*2 ILLEGAL*2 ILLEGAL ILLEGAL ILLEGAL*2 ILLEGAL*2 ILLEGAL*2 ILLEGAL ILLEGAL
READ/WRITE ILLEGAL*2
READ/WRITE ILLEGAL*2
READ/WRITE ILLEGAL*2
MIT-DS-0243-0.0
29.July.1998
MITSUBISHI ELECTRIC
MH32S72BAFA -7,-8
2,415,919,104-BIT 33,554,432-WORD 72-BIT Synchronous DYNAMIC
FUNCTION TRUTH TABLE(continued)
Current State REFRESHING MODE REGISTER SETTING /RAS /CAS BA,CA,A10 BA,RA BA,A10 Op-Code, Mode-Add BA,CA,A10 BA,RA BA,A10 Op-Code, Mode-Add Address Command DESEL TBST Action NOP(Idle after tRC) NOP(Idle after tRC) ILLEGAL
READ/WRITE ILLEGAL PRE/PREA REFA DESEL TBST ILLEGAL ILLEGAL ILLEGAL ILLEGAL NOP(Idle after tRSC) NOP(Idle after tRSC) ILLEGAL
READ/WRITE ILLEGAL PRE/PREA REFA ILLEGAL ILLEGAL ILLEGAL ILLEGAL
ABBREVIATIONS: Hige Level, Level, Don't Care Bank Address, Address, Column Address, Operation NOTES: entries assume that High during preceding clock cycle current clock cycle. ILLEGAL bank specified state; function legal bank indicated depending state that bank. Must satisfy contention, turn around, write recovery requirements. bank precharging idle state.May precharge bank indicated ILLEGAL bank idle. ILLEGAL Device operation date-integrity guaranteed.
MIT-DS-0243-0.0
29.July.1998
MITSUBISHI ELECTRIC
MH32S72BAFA -7,-8
2,415,919,104-BIT 33,554,432-WORD 72-BIT Synchronous DYNAMIC
FUNCTION TRUTH TABLE
Current State SELF REFRESH*1 POWER DOWN BANKS IDLE*2 STATE other than listed above /RAS /CAS INVALID Exit Self-Refresh(Idle after tRC) Exit Self-Refresh(Idle after tRC) ILLEGAL ILLEGAL ILLEGAL NOP(Maintain Self-Refresh) INVALID Exit Power Down Idle NOP(Maintain Self-Refresh) Refer Function Truth Table Enter Self-Refresh Enter Power Down Enter Power Down ILLEGAL ILLEGAL ILLEGAL Refer Current State Power Down Refer Function Truth Table Begin Suspend Next Cycle*3 Exit Suspend Next Cycle*3 Maintain Suspend Action
ABBREVIATIONS: High Level, Level, Don't Care NOTES: High transition will re-enable other inputs asynchronously. minimum setup time must satisfied before command other than EXIT. Power-Down Self-Refresh entered only form banks idle State. Must legal command.
MIT-DS-0243-0.0
29.July.1998
MITSUBISHI ELECTRIC
MH32S72BAFA -7,-8
2,415,919,104-BIT 33,554,432-WORD 72-BIT Synchronous DYNAMIC
POWER SEQUENCE
Before starting normal operation, following power sequence necessary prevent SDRAM from damaged malfunctioning. Apply power start clock. Attempt maintain high, DQMB high condition inputs. Maintain stable power, stable cock, input conditions minimum 500µs. Issue precharge commands banks. (PRE PREA) After banks become idle state (after tRP), issue more auto-refresh commands. Issue mode register command initialize mode register. After these sequence, SDRAM idle state ready normal operation.
MODE REGISTER
Burst Length, Burst Type /CAS Latency programmed setting mode register(MRS). mode register stores these date until next command, which issue when both banks idle state. After tRSC from command, SDRAM ready command.
/RAS /CAS BA0,1 A11-A0
LTMODE
LATENCY MODE
/CAS LATENCY BURST SINGLE
BURST LENGTH
WRITE MODE
BURST TYPE
SEQUENTIAL INTERLEAVED Reserved Future Full Page 29.July.1998
MIT-DS-0243-0.0
MITSUBISHI ELECTRIC
MH32S72BAFA -7,-8
2,415,919,104-BIT 33,554,432-WORD 72-BIT Synchronous DYNAMIC
Command Address /CAS Latency
Read Write
Burst Length Burst Type
Burst Length
Initial Address Sequential
Column Addressing Interleaved
MIT-DS-0243-0.0
29.July.1998
MITSUBISHI ELECTRIC
MH32S72BAFA -7,-8
2,415,919,104-BIT 33,554,432-WORD 72-BIT Synchronous DYNAMIC
ABSOLUTE MAXIMUM RATINGS
Symbol Topr Tstg Parameter Supply Voltage Input Voltage Output Voltage Output Current Power Dissipation Operating Temperature Storage Temperature Ta=25°C Condition with respect with respect with respect Ratings -0.5 -0.5 -0.5 Unit
RECOMMENDED OPERATING CONDITION
(Ta=0 70°C, unless otherwise noted) Symbol Parameter Min. Supply Voltage Supply Voltage High-Level Input Voltage inputs Low-Level Input Voltage inputs -0.3 Limits Typ. Max. Vdd+0.3 Unit
CAPACITANCE
(Ta=0 70°C, 0.3V, unless otherwise noted) Symbol CI(A) CI(C) CI(K) CI/O Parameter Input Capacitance, address Input Capacitance, control Input Capacitance, Input Capacitance, Test Condition f=1MHz Vi=25mVrms Limits(max.) Unit
MIT-DS-0243-0.0
29.July.1998
MITSUBISHI ELECTRIC
MH32S72BAFA -7,-8
2,415,919,104-BIT 33,554,432-WORD 72-BIT Synchronous DYNAMIC
AVERAGE SUPPLY CURRENT from
(Ta=0 ~70°C, 0.3V, unless otherwise noted)
Parameter
operating current bank active (discrete)
Symbol Icc1 Icc2P
Test Condition tRC=min.tCLK=min, BL=1, IOL=min
Limits (max) 2411
Unit
precharge stanby current power-down mode precharge stanby current power-down mode active stanby current power-down mode active stanby current power-down mode
bank active (discrete)
CKE=VILmax,tCLK=15ns Icc2PS CKE=CLK=VILmax(fixed) Icc2N CKE=/CS=VIHmin,tCLK=15ns(Note) Icc2NS CKE=VIHmin,CLK=VILmax(fixed) Icc3P CKE=VILmax,tCLK=15ns Icc3PS CKE=CLK=VILmax(fixed) Icc3N CKE=/CS=VIHmin,tCLK=15ns Icc3NS CKE=VIHmin,CLK=VILmax(fixed) Icc4 tCLK=min, BL=4, CL=3,IOL=0mAall banks active(discerte) tRC=min, tCLK=min Icc5 Icc6 <0.2V
2015 1475 2501 5435
burst current auto-refresh current self-refresh current
Note:Input signals changed time during 30ns.
OPERATING CONDITIONS CHARACTERISTICS
(Ta=0 70°C, 0.3V, unless otherwise noted)
Symbol VOH(DC) VOL(DC) VOH(AC VOL(AC) Parameter High-Level Output Voltage(DC) Low-Level Output Voltage(DC) Off-stare Output Current High-Level Output Voltage(AC) Input Current Low-Level Output Voltage(AC) Test Condition IOH=-2mA IOL=2mA floating CL=50pF, VO=0 IOH=-2mAIOL=2mA VIH=0 Vdd+0.3V CL=50pF, Limits Unit Min. Max.
MIT-DS-0243-0.0
29.July.1998
MITSUBISHI ELECTRIC
MH32S72BAFA -7,-8
2,415,919,104-BIT 33,554,432-WORD 72-BIT Synchronous DYNAMIC
TIMING REQUIREMENTS
(Ta=0 70°C, 0.3V, unless otherwise noted) Input Pulse Levels: 0.8V 2.0V Input Timing Measurement Level: 1.4V LATCH MODE Limits Symbol Parameter Min. tCLK tRCD tRAS tRRD tCCD tRSC tSRX tREF cycle time CL=3 CL=4
Max. Min.
Max.
Unit
High pulse width pilse width Transition time Input Setup time(all inputs) Input Hold time(all inputs) cycle time Column Delay Active time Precharge time Write Recovery time Deley time Delay time Mode Register Cycle time Self Refresh Exit time Refresh Interval time
100000
100000
Note:1 timing requirements assumed tT=1ns. longer than 1ns, (tT-1)ns should added parameter.
1.4V
timing referenced input signal crossing through 1.4V.
Signal
1.4V
MIT-DS-0243-0.0
29.July.1998
MITSUBISHI ELECTRIC
MH32S72BAFA -7,-8
2,415,919,104-BIT 33,554,432-WORD 72-BIT Synchronous DYNAMIC
BUFFER MODE Limits Symbol Parameter Min. tCLK tRCD tRAS tRRD tCCD tRSC tSRX tREF cycle time CL=2 CL=3
Max. Min.
Max.
Unit
High pulse width pilse width Transition time Input Setup time(all inputs) Input Hold time(all inputs) cycle time Column Delay Active time Precharge time Write Recovery time Deley time Delay time Mode Register Cycle time Self Refresh Exit time Refresh Interval time
100000
100000
Note:1 timing requirements assumed tT=1ns. longer than 1ns, (tT-1)ns should added parameter.
SWITCHING CHARACTERISTICS
(Ta=0 70°C, 0.3V, unless otherwise noted) LATCH MODE Limits Symbol Parameter Min. tOLZ tOHZ Access time from Output Hold time from Delay time, output impedance from Delay time, output high impedance from CL=3 CL=4 Max.
Min. Max.
Unit
MIT-DS-0243-0.0
29.July.1998
MITSUBISHI ELECTRIC
MH32S72BAFA -7,-8
2,415,919,104-BIT 33,554,432-WORD 72-BIT Synchronous DYNAMIC
BUFFER MODE Limits Symbol Parameter Min. tOLZ tOHZ Access time from Output Hold time from Delay time, output impedance from Delay time, output high impedance from CL=2 CL=3 Max.
Min. Max.
Unit
Output Load Condition
VTT=1.4V VOUT 50pF Output Timing Measurement Reference Point 1.4V 1.4V
1.4V
tOHZ
1.4V
MIT-DS-0243-0.0
29.July.1998
MITSUBISHI ELECTRIC
MH32S72BAFA -7,-8
2,415,919,104-BIT 33,554,432-WORD 72-BIT Synchronous DYNAMIC
WRITE CYCLE (single bank)
BL=4,Buffer mode(REGE="L")
tRAS
/RAS
tRCD tRCD
/CAS
A0-9
BA0,1 REGE
ACT#0
WRITE#0
PRE#0
ACT#0
WRITE#0
Italic parameter indicates minimum case MIT-DS-0243-0.0 29.July.1998
MITSUBISHI ELECTRIC
MH32S72BAFA -7,-8
2,415,919,104-BIT 33,554,432-WORD 72-BIT Synchronous DYNAMIC
WRITE CYCLE (dual bank)
BL=4,Buffer mode(REGE="L")
tRRD tRRD
tRAS
tRCD
/RAS
tRCD
/CAS
A0-9
BA0,1
REGE
ACT#0
WRITE#0 ACT#1
PRE#0 WRITE#1
ACT#0
ACT#2 WRITE#0 PRE#1
Italic parameter indicates minimum case MIT-DS-0243-0.0 29.July.1998
MITSUBISHI ELECTRIC
MH32S72BAFA -7,-8
2,415,919,104-BIT 33,554,432-WORD 72-BIT Synchronous DYNAMIC
WRITE CYCLE (single bank)
BL=4,Lacth mode(REGE="H")
tRAS
/RAS
tRCD tRCD
/CAS
A0-9
BA0,1 REGE
ACT#0
WRITE#0
PRE#0
ACT#0
WRITE#0
Italic parameter indicates minimum case 29.July.1998
MIT-DS-0243-0.0
MITSUBISHI ELECTRIC
MH32S72BAFA -7,-8
2,415,919,104-BIT 33,554,432-WORD 72-BIT Synchronous DYNAMIC
WRITE CYCLE (dual bank)
BL=4,Latch mode(REGE="H")
tRRD tRRD
tRAS
tRCD
/RAS
tRCD
/CAS
A0-9
BA0,1 REGE
ACT#0
WRITE#0 ACT#1
PRE#0 WRITE#1
ACT#0
ACT#2 WRITE#0 PRE#1
Italic parameter indicates minimum case MIT-DS-0243-0.0 29.July.1998
MITSUBISHI ELECTRIC
MH32S72BAFA -7,-8
2,415,919,104-BIT 33,554,432-WORD 72-BIT Synchronous DYNAMIC
READ CYCLE (single bank)
BL=4,CL=3,Buffer mode(REGE="L")
tRAS
/RAS
tRCD tRCD
/CAS
read latency
A0-9
BA0,1 REGE
CL=3
ACT#0 READ#0
PRE#0
ACT#0
READ#0
READ allows full data
Italic parameter indicates minimum case MIT-DS-0243-0.0 29.July.1998
MITSUBISHI ELECTRIC
MH32S72BAFA -7,-8
2,415,919,104-BIT 33,554,432-WORD 72-BIT Synchronous DYNAMIC
READ CYCLE (dual bank)
BL=4,CL=3,Buffer mode(REGE="L")
tRRD tRAS tRCD tRRD
/RAS
tRCD
/CAS
read latency
A0-9 BA0,1
REGE
CL=3 CL=3
ACT#0 READ#0 ACT#1
PRE#0 READ#1
ACT#0 PRE#1
READ#0 ACT#2
Italic parameter indicates minimum case MIT-DS-0243-0.0 29.July.1998
MITSUBISHI ELECTRIC
MH32S72BAFA -7,-8
2,415,919,104-BIT 33,554,432-WORD 72-BIT Synchronous DYNAMIC
READ CYCLE (single bank)
BL=4, CL=3,Latch mode(REGE="H")
tRAS
/RAS
tRCD tRCD
/CAS
read latency
A0-9
BA0,1 REGE
CL=3
ACT#0 READ#0
PRE#0
ACT#0
READ#0
READ allows full data
Italic parameter indicates minimum case MIT-DS-0243-0.0 29.July.1998
MITSUBISHI ELECTRIC
MH32S72BAFA -7,-8
2,415,919,104-BIT 33,554,432-WORD 72-BIT Synchronous DYNAMIC
READ CYCLE (dual bank)
BL=4,CL=3,Latch mode(REGE="H")
tRRD tRAS tRCD tRRD
/RAS
tRCD
/CAS
read latency
A0-9 BA0,1
REGE
CL=3 CL=3
ACT#0 READ#0 ACT#1
PRE#0 READ#1
ACT#0 PRE#1
READ#0 ACT#2
Italic parameter indicates minimum case MIT-DS-0243-0.0 29.July.1998
MITSUBISHI ELECTRIC
MH32S72BAFA -7,-8
2,415,919,104-BIT 33,554,432-WORD 72-BIT Synchronous DYNAMIC
Burst WRITE (multi bank) with AUTO-PRECHARGE BL=4,Buffer mode(REGE="L")
tRRD tRRD
/RAS
tRCD tRCD BL-1+ BL-1+ tRCD
/CAS A0-9
BA0,1
REGE
ACT#0 ACT#1
WRITE#0 with AutoPrecharge
ACT#0 WRITE#1 with AutoPrecharge
WRITE#0 ACT#1
WRITE#1
Italic parameter indicates minimum case MIT-DS-0243-0.0 29.July.1998
MITSUBISHI ELECTRIC
MH32S72BAFA -7,-8
2,415,919,104-BIT 33,554,432-WORD 72-BIT Synchronous DYNAMIC
Burst WRITE (multi bank) with AUTO-PRECHARGE BL=4,Latch mode(REGE="H")
tRRD tRRD
/RAS
tRCD tRCD BL-1+ BL-1+ tRCD
/CAS A0-9
BA0,1
REGE
ACT#0 ACT#1
WRITE#0 with AutoPrecharge
ACT#0 WRITE#1 with AutoPrecharge
WRITE#0 ACT#1
WRITE#1
Italic parameter indicates minimum case MIT-DS-0243-0.0 29.July.1998
MITSUBISHI ELECTRIC
MH32S72BAFA -7,-8
2,415,919,104-BIT 33,554,432-WORD 72-BIT Synchronous DYNAMIC
Burst READ (multi bank) with AUTO-PRECHARGE
BL=4,Buffer mode(REGE="L")
tRRD tRRD
/RAS
tRCD tRCD BL+tRP BL+tRP tRCD
/CAS
read latency
A0-9
BA0,1 REGE
CL=3
CL=3
CL=3
ACT#0 ACT#1
READ#0 with Auto-Precharge
ACT#0 READ#1 with Auto-Precharge
READ#0 ACT#1
Italic parameter indicates minimum case MIT-DS-0243-0.0 29.July.1998
MITSUBISHI ELECTRIC
MH32S72BAFA -7,-8
2,415,919,104-BIT 33,554,432-WORD 72-BIT Synchronous DYNAMIC
Burst READ (multi bank) with AUTO-PRECHARGE
BL=4,Latch mode(REGE="H")
tRRD tRRD
/RAS
tRCD tRCD BL+tRP BL+tRP tRCD
/CAS
read latency
A0-9
BA0,1 REGE
CL=3
CL=3
CL=3
ACT#0 ACT#1
READ#0 with Auto-Precharge
ACT#0 READ#1 with Auto-Precharge
READ#0 ACT#1
Italic parameter indicates minimum case MIT-DS-0243-0.0 29.July.1998
MITSUBISHI ELECTRIC
MH32S72BAFA -7,-8
2,415,919,104-BIT 33,554,432-WORD 72-BIT Synchronous DYNAMIC
Page Mode Burst Write (multi bank)
BL=4,Buffer mode(REGE="L")
tRRD
/RAS
tRCD
/CAS A0-9
BA0,1 REGE
ACT#0
WRITE#0 ACT#1
WRITE#0 WRITE#1
WRITE#0
Italic parameter indicates minimum case MIT-DS-0243-0.0 29.July.1998
MITSUBISHI ELECTRIC
MH32S72BAFA -7,-8
2,415,919,104-BIT 33,554,432-WORD 72-BIT Synchronous DYNAMIC
Page Mode Burst Write (multi bank)
BL=4,Latch mode(REGE="H")
tRRD
/RAS
tRCD
/CAS A0-9
BA0,1 REGE
ACT#0
WRITE#0 ACT#1
WRITE#0 WRITE#1
WRITE#0
Italic parameter indicates minimum case MIT-DS-0243-0.0 29.July.1998
MITSUBISHI ELECTRIC
MH32S72BAFA -7,-8
2,415,919,104-BIT 33,554,432-WORD 72-BIT Synchronous DYNAMIC
Page Mode Burst Read (multi bank)
BL=4,Buffer mode(REGE="L")
tRRD
/RAS
tRCD
/CAS
read latency=2
A0-9
BA0,1 REGE
CL=3
CL=3
CL=3
ACT#0 READ#0 ACT#1
READ#0 READ#1
READ#0
Italic parameter indicates minimum case MIT-DS-0243-0.0 29.July.1998
MITSUBISHI ELECTRIC
MH32S72BAFA -7,-8
2,415,919,104-BIT 33,554,432-WORD 72-BIT Synchronous DYNAMIC
Page Mode Burst Read (multi bank)
BL=4,Latch mode(REGE="H")
tRRD
/RAS
tRCD
/CAS
read latency=3
A0-9
BA0,1 REGE
CL=3
CL=3
CL=3
ACT#0 READ#0 ACT#1
READ#0 READ#1
READ#0
Italic parameter indicates minimum case MIT-DS-0243-0.0 29.July.1998
MITSUBISHI ELECTRIC
MH32S72BAFA -7,-8
2,415,919,104-BIT 33,554,432-WORD 72-BIT Synchronous DYNAMIC
Write Interrupted Write Read
BL=4,Buffer mode(REGE="L")
tRRD
/RAS
tRCD tCCD
/CAS A0-9
BA0,1 REGE
CL=3
ACT#0 WRITE#0 WRITE#0 WRITE#0 READ#0 ACT#1 WRITE#1 Burst Write interrupted Write Read active bank. Italic parameter indicates minimum case MIT-DS-0243-0.0 29.July.1998
MITSUBISHI ELECTRIC
MH32S72BAFA -7,-8
2,415,919,104-BIT 33,554,432-WORD 72-BIT Synchronous DYNAMIC
Write Interrupted Write Read
BL=4,Latch mode(REGE="H")
tRRD
/RAS
tRCD tCCD
/CAS A0-9
BA0,1 REGE
CL=3
ACT#0 WRITE#0 WRITE#0 WRITE#0 READ#0 ACT#1 WRITE#1 Burst Write interrupted Write Read active bank. Italic parameter indicates minimum case MIT-DS-0243-0.0 29.July.1998
MITSUBISHI ELECTRIC
MH32S72BAFA -7,-8
2,415,919,104-BIT 33,554,432-WORD 72-BIT Synchronous DYNAMIC
Read Interrupted Read Write
BL=4,Buffer mode(REGE="L")
tRRD
/RAS
tRCD
/CAS
read latency=2
A0-9
BA0,1 REGE
ACT#0
READ#0 READ#0 READ#0 READ#0 WRITE#0 ACT#1 READ#1 blank prevent contention
Burst Read interrupted Read Write active bank. Italic parameter indicates minimum case MIT-DS-0243-0.0 29.July.1998
MITSUBISHI ELECTRIC
MH32S72BAFA -7,-8
2,415,919,104-BIT 33,554,432-WORD 72-BIT Synchronous DYNAMIC
Read Interrupted Read Write
BL=4,Latch mode(REGE="H")
tRRD
/RAS
tRCD
/CAS
read latency=3
A0-9
BA0,1 REGE
ACT#0
READ#0 READ#0 READ#0 READ#0 WRITE#0 ACT#1 READ#1 blank prevent contention
Burst Read interrupted Read Write active bank. Italic parameter indicates minimum case MIT-DS-0243-0.0 29.July.1998
MITSUBISHI ELECTRIC
MH32S72BAFA -7,-8
2,415,919,104-BIT 33,554,432-WORD 72-BIT Synchronous DYNAMIC
Write Interrupted Precharge
BL=4,Buffer mode(REGE="L")
tRRD
/RAS
tRCD
/CAS A0-9
BA0,1 REGE
ACT#0 WRITE#0 ACT#1
PRE#0 WRITE#1 PRE#1
ACT#1
WRITE#1
Burst Write interrupted Precharge other bank.
Burst Write interrupted Precharge same bank. Italic parameter indicates minimum case
MIT-DS-0243-0.0
29.July.1998
MITSUBISHI ELECTRIC
MH32S72BAFA -7,-8
2,415,919,104-BIT 33,554,432-WORD 72-BIT Synchronous DYNAMIC
Write Interrupted Precharge
BL=4,Latch mode(REGE="H")
tRRD
/RAS
tRCD
/CAS A0-9
BA0,1 REGE
ACT#0 WRITE#0 ACT#1
PRE#0 WRITE#1 PRE#1
ACT#1
WRITE#1
Burst Write interrupted Precharge other bank.
Burst Write interrupted Precharge same bank. Italic parameter indicates minimum case
MIT-DS-0243-0.0
29.July.1998
MITSUBISHI ELECTRIC
MH32S72BAFA -7,-8
2,415,919,104-BIT 33,554,432-WORD 72-BIT Synchronous DYNAMIC
Read Interrupted Precharge
BL=4,Buffer mode(REGE="L")
tRRD
/RAS
tRCD tRCD
/CAS
read latency=2
A0-9
BA0,1 REGE
ACT#0
READ#0 ACT#1
PRE#0 READ#1 PRE#1
ACT#1
READ#1
Burst Read interrupted Precharge other bank.
Burst Read interrupted Precharge same bank. Italic parameter indicates minimum case
MIT-DS-0243-0.0
29.July.1998
MITSUBISHI ELECTRIC
MH32S72BAFA -7,-8
2,415,919,104-BIT 33,554,432-WORD 72-BIT Synchronous DYNAMIC
Read Interrupted Precharge
BL=4,Latch mode(REGE="H")
tRRD
/RAS
tRCD tRCD
/CAS
read latency=3
A0-9
BA0,1 REGE
ACT#0
READ#0 ACT#1
PRE#0 READ#1 PRE#1
ACT#1
READ#1
Burst Read interrupted Precharge other bank.
Burst Read interrupted Precharge same bank. Italic parameter indicates minimum case
MIT-DS-0243-0.0
29.July.1998
MITSUBISHI ELECTRIC
MH32S72BAFA -7,-8
2,415,919,104-BIT 33,554,432-WORD 72-BIT Synchronous DYNAMIC
Mode Register Setting
tRSC
/RAS
tRCD
/CAS A0-9
BA0,1 REGE
Auto-Ref (last cycles)
Mode Register Setting
ACT#0
WRITE#0
Italic parameter indicates minimum case MIT-DS-0243-0.0 29.July.1998
MITSUBISHI ELECTRIC
MH32S72BAFA -7,-8
2,415,919,104-BIT 33,554,432-WORD 72-BIT Synchronous DYNAMIC
Auto-Refresh @BL=4
/RAS
tRCD
/CAS A0-9
BA0,1 REGE
Auto-Refresh Before Auto-Refresh, banks must idle state.
ACT#0
WRITE#0
After from Auto-Refresh, banks idle state. Italic parameter indicates minimum case
MIT-DS-0243-0.0
29.July.1998
MITSUBISHI ELECTRIC
MH32S72BAFA -7,-8
2,415,919,104-BIT 33,554,432-WORD 72-BIT Synchronous DYNAMIC
Self-Refresh
stopped
/RAS /CAS
tSRX
must maintain Self-Refresh
A0-9 BA0,1 REGE
Self-Refresh Entry Before Self-Refresh Entry, banks must idle state.
Self-Refresh Exit After from Self-Refresh Exit, banks idle state.
ACT#0
Italic parameter indicates minimum case MIT-DS-0243-0.0 29.July.1998
MITSUBISHI ELECTRIC
MH32S72BAFA -7,-8
2,415,919,104-BIT 33,554,432-WORD 72-BIT Synchronous DYNAMIC
Write Mask @BL=4
BL=4,Buffer mode(REGE="L")
/RAS
tRCD
/CAS A0-9
BA0,1 REGE
masked
masked
ACT#0
WRITE#0
WRITE#0
WRITE#0
Italic parameter indicates minimum case MIT-DS-0243-0.0 29.July.1998
MITSUBISHI ELECTRIC
MH32S72BAFA -7,-8
2,415,919,104-BIT 33,554,432-WORD 72-BIT Synchronous DYNAMIC
Write Mask @BL=4
BL=4,Latch mode(REGE="H")
/RAS
tRCD
/CAS A0-9
BA0,1 REGE
masked
masked
ACT#0
WRITE#0
WRITE#0
WRITE#0
Italic parameter indicates minimum case MIT-DS-0243-0.0 29.July.1998
MITSUBISHI ELECTRIC
MH32S72BAFA -7,-8
2,415,919,104-BIT 33,554,432-WORD 72-BIT Synchronous DYNAMIC
Read Mask @BL=4 CL=3
BL=4,Buffer mode(REGE="L")
/RAS
tRCD
/CAS
read latency=2
A0-9
BA0,1 REGE
masked
masked
ACT#0
READ#0
READ#0
READ#0
Italic parameter indicates minimum case MIT-DS-0243-0.0 29.July.1998
MITSUBISHI ELECTRIC
MH32S72BAFA -7,-8
2,415,919,104-BIT 33,554,432-WORD 72-BIT Synchronous DYNAMIC
Read Mask @BL=4 CL=3
BL=4,Latch mode(REGE="H")
/RAS
tRCD
/CAS
read latency=3
A0-9
BA0,1 REGE
masked
masked
ACT#0
READ#0
READ#0
READ#0
Italic parameter indicates minimum case MIT-DS-0243-0.0 29.July.1998
MITSUBISHI ELECTRIC
MH32S72BAFA -7,-8
2,415,919,104-BIT 33,554,432-WORD 72-BIT Synchronous DYNAMIC
Power Down
/RAS /CAS
Standby Power Down
latency=1
Active Power Down
A0-9
BA0,1 REGE
Precharge
ACT#0
Italic parameter indicates minimum case MIT-DS-0243-0.0 29.July.1998
MITSUBISHI ELECTRIC
MH32S72BAFA -7,-8
2,415,919,104-BIT 33,554,432-WORD 72-BIT Synchronous DYNAMIC
Suspend @BL=4 CL=3
BL=4,Buffer mode(REGE="L")
/RAS
tRCD
/CAS
latency=1 latency=1
A0-9
BA0,1 REGE
ACT#0
WRITE#0 READ#0 suspended
suspended Italic parameter indicates minimum case 29.July.1998
MIT-DS-0243-0.0
MITSUBISHI ELECTRIC
MH32S72BAFA -7,-8
2,415,919,104-BIT 33,554,432-WORD 72-BIT Synchronous DYNAMIC
Suspend @BL=4 CL=3
BL=4,Latch mode(REGE="H")
/RAS
tRCD
/CAS
latency=1 latency=1
A0-9
BA0,1 REGE
ACT#0
WRITE#0 READ#0 suspended
suspended Italic parameter indicates minimum case 29.July.1998
MIT-DS-0243-0.0
MITSUBISHI ELECTRIC
MH32S72BAFA -7,-8
2,415,919,104-BIT 33,554,432-WORD 72-BIT Synchronous DYNAMIC
133.35
11.43
6.35 36.83 24.495 42.18
6.35 54.61 127.35
1.27
43.18 6.88Min
29.July.1998
8.89
MIT-DS-0243-0.0
17.78
MITSUBISHI ELECTRIC
MH32S72BAFA -7,-8
2,415,919,104-BIT 33,554,432-WORD 72-BIT Synchronous DYNAMIC
Keep safety first your circuit designs!
Mitsubishi Electric Corporation puts maximum effort into making semiconductor products better more reliable,but there always possibility that trouble occur with them. Trouble with semiconductors consideration safety when making your circuit designs,with appropriate measures such placement substitutive,auxiliary circuits,(ii) non-flammable material (iii) prevention against malfunction mishap.
Notes regarding these materials
1.These materials intended reference assist customers selection Mitsubishi semiconductor product best suited customer's application;they convey license under intellectual property rights,or other rights,belonging Mitsubishi Electric Corporation third party. 2.Mitsubishi Electric Corporation assumes responsibility damage, infringement third-party's rights,originating product data,diagrams,charts circuit application examples contained these materials. 3.All information contained these materials,including product data, diagrams charts,represent information products time publication these materials,and subject change Mitsubishi Electric Corporation without notice product improvements other reasons. therefore recommended that customers contact Mitsubishi Electric Corporation authorized Mitsubishi Semiconductor product distributor latest product information before purchasing product listed herein. 4.Mitsubishi Electric Corporation semiconductors designed manufactured device system that used under circumstances which human life potentially stake. Please contact Mitsubishi Electric Corporation authorized Mitsubishi Semiconductor product distributor when considering product contained herein special applications,such apparatus systems transportation, undersea repeater use. 5.The prior written approval Mitsubishi Electric Corporation necessary reprint reproduce whole part these materials. 6.If these products technologies subject Japanese export control restrictions,they must exported under license from Japanese government cannot imported into country other than approved destination. diversion reexport contrary export control laws regulations Japan and/or country destination prohibited. 7.Please contact Mitsubishi Electric Corporation authorized Mitsubishi Semiconductor product distributor further details these materials products contained therein.
MIT-DS-0243-0.0
29.July.1998
MITSUBISHI ELECTRIC

Other recent searches


XP132A1275SR - XP132A1275SR   XP132A1275SR Datasheet
TMD10099CS - TMD10099CS   TMD10099CS Datasheet
TMD10100CS - TMD10100CS   TMD10100CS Datasheet
TMD10101CS - TMD10101CS   TMD10101CS Datasheet
TMD10102CS - TMD10102CS   TMD10102CS Datasheet
TMD10103CS - TMD10103CS   TMD10103CS Datasheet
TMD10104CS - TMD10104CS   TMD10104CS Datasheet
TMD10105CS - TMD10105CS   TMD10105CS Datasheet
TMD10106CS - TMD10106CS   TMD10106CS Datasheet
TMD10107CS - TMD10107CS   TMD10107CS Datasheet
TMD10108CS - TMD10108CS   TMD10108CS Datasheet
TMD10109CS - TMD10109CS   TMD10109CS Datasheet
TMD10110CS - TMD10110CS   TMD10110CS Datasheet
TMD10111CS - TMD10111CS   TMD10111CS Datasheet
TMD10112CS - TMD10112CS   TMD10112CS Datasheet
TMD10113CS - TMD10113CS   TMD10113CS Datasheet
TMD10114CS - TMD10114CS   TMD10114CS Datasheet
TMD10115CS - TMD10115CS   TMD10115CS Datasheet
TMD10116CS - TMD10116CS   TMD10116CS Datasheet
TMD10117CS - TMD10117CS   TMD10117CS Datasheet
TMD10118CS - TMD10118CS   TMD10118CS Datasheet
TMD10119CS - TMD10119CS   TMD10119CS Datasheet
TMD20013 - TMD20013   TMD20013 Datasheet
NTE1024 - NTE1024   NTE1024 Datasheet
MURS320 - MURS320   MURS320 Datasheet
M27V405 - M27V405   M27V405 Datasheet
LDD495 - LDD495   LDD495 Datasheet
64-10 - 64-10   64-10 Datasheet
SRPX-X - SRPX-X   SRPX-X Datasheet
DD-30 - DD-30   DD-30 Datasheet
DD-29 - DD-29   DD-29 Datasheet
DD-28 - DD-28   DD-28 Datasheet
DD-27 - DD-27   DD-27 Datasheet
DD-26 - DD-26   DD-26 Datasheet
DD-25 - DD-25   DD-25 Datasheet

 

Privacy Policy | Disclaimer
© 2012 Datasheet Archive