| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
LC75392, 75392M Single-Chip Electronic Volume Control System
Top Searches for this datasheetOrdering number EN5681 LC75392, 75392M Single-Chip Electronic Volume Control System Overview LC75392 (DIP-30SD) LC75392M (MFP30S) electronic volume control that provide input output switching, volume, tone control functions controlled data transferred over serial interface. Package Dimensions unit: 3196-DIP30SD [LC75392] Functions Input output switching: Four inputs outputs switched independently. Volume control: balance function implemented controlling left right levels independently. Each channel steps, steps, steps, steps, controls: Internal switches provided select between four sets frequency characteristics. buffer function implemented using external components. SANYO: DIP30SD unit: 3216-MFP30S [LC75392M] Features Serial data interface: Support control communication format. SANYO: MFP30S Specifications Absolute Maximum Ratings 25°C, Parameter Maximum supply voltage Maximum input voltage Allowable power dissipation Operating temperature Storage temperature Symbol Topr Tstg 85°C Conditions Ratings +125 Unit trademark SANYO ELECTRIC CO., LTD. SANYO's original format addresses controlled SANYO. SANYO Electric Co.,Ltd. Semiconductor Bussiness Headquarters TOKYO OFFICE Tokyo Bldg., 1-10, Chome, Ueno, Taito-ku, TOKYO, JAPAN 73097HA(OT) 5681-1/12 LC75392, 75392M Allowable Operating Ranges 25°C, Parameter Supply voltage Input high-level voltage Input low-level voltage Input voltage amplitude Input pulse width Setup time Hold time Operating frequency Symbol tsetup thold fopg Conditions Ratings 11.0 Unit Vp-p Electrical Characteristics 25°C, Parameter [Input Block] Input resistance [Overall] THD1 Total harmonic distortion THD2 Crosstalk Output maximum attenuation Output noise voltage Current drain Input high-level current Input low-level current rms, kHz, overall, buffer mode off, flat state rms, kHz, overall, buffer mode off, flat state rms, kHz, overall, buffer mode off, flat state rms, kHz, main volume buffer mode Flat overall (IHF-A), buffer mode off, flat state Flat overall (DIN-AUDIO), buffer mode off, flat state 0.013 0.013 Symbol Conditions Ratings Unit Equivalent Circuit Block Diagram Latch Decoder Control Shift register 5681-2/12 LC75392, 75392M Test Circuit Total Harmonic Distortion circuit constants identical those right channel. Distortion analyzer 5681-3/12 LC75392, 75392M Output Noise Voltage Noise meter circuit constants identical those right channel. 5681-4/12 LC75392, 75392M Crosstalk Volt meter circuit constants identical those right channel. 5681-5/12 LC75392, 75392M Assignment view Functions Function Circuit LVROUT RVROUT Volume control outputs LVRIN RVRIN Volume control inputs LTOUT RTOUT Tone control circuit outputs LTCOM RTCOM Tone control circuit operational amplifier inverting inputs Connections tone control pattern external constants Continued next page. 5681-6/12 LC75392, 75392M Continued from preceding page. Function Circuit Audio signal inputs outputs Vref Power supply Analog system ground Ground Serial data clock inputs device control Chip enable Data read into internal latch analog switches operate when this goes from high low. Data transfers enabled when this high. 5681-7/12 LC75392, 75392M Volume Control Equivalent Circuit 5681-8/12 LC75392, 75392M Control System Timing Data Format control LC75392, applications must apply data stipulated format pins. This data consists bits, which bits address bits control data. tDEST Don't care Volume control data Don't Don't care care Tone pattern control data Don't care Buffer mode Test mode Don't care Function switch control data Channel selection Left right same time Note: bits D20, D21, test mode control data. User applications must always these bits 5681-9/12 LC75392, 75392M Sample Application Circuit (Three-input type) circuit constants identical those right channel. Usage Notes states internal analog switches undefined immediately after power first applied. Applications should apply muting outputs this using external circuits until control data been lines should shielded ground pattern shielded lines should used prevent high-frequency digital signals that transmitted over these lines from entering analog system noise. recommend that applications sequence several smaller steps approach final setting when changing value volume control setting significantly. example, sequence shown below should used when changing from This reduce switching noise. Example: 5681-10/12 LC75392, 75392M Main Volume Step Characteristics Tone Control Characteristics Main volume attenuation Overall Output level Steps Frequency, Frequency Characteristics Total harmonic distortion, Total harmonic distortion, Power-Supply Voltage Characteristics low-pass filter Overall low-pass filter Overall Buffer mode Flat Frequency, Power-supply voltage, Input Level Characteristics Total harmonic distortion, low-pass filter Overall Buffer mode Flat Input level, 5681-11/12 LC75392, 75392M products described contained herein intended surgical implants, life-support systems, aerospace equipment, nuclear power control systems, vehicles, disaster/crime-prevention equipment like, failure which directly indirectly cause injury, death property loss. Anyone purchasing products described contained herein above-mentioned shall: Accept full responsibility indemnify defend SANYO ELECTRIC CO., LTD., affiliates, subsidiaries distributors their officers employees, jointly severally, against claims litigation damages, cost expenses associated with such use: impose responsibility fault negligence which cited such claim litigation SANYO ELECTRIC CO., LTD., affiliates, subsidiaries distributors their officers employees jointly severally. Information (including circuit diagrams circuit parameters) herein example only; guaranteed volume production. SANYO believes information herein accurate reliable, guarantees made implied regarding infringements intellectual property rights other rights third parties. This catalog provides information July, 1997. Specifications information herein subject change without notice. 5681-12/12 Other recent searchesLMC6492 - LMC6492 LMC6492 Datasheet nat2000 - nat2000 nat2000 Datasheet KSK-1A83- - KSK-1A83- KSK-1A83- Datasheet DO219-AB - DO219-AB DO219-AB Datasheet B69842N1507A580 - B69842N1507A580 B69842N1507A580 Datasheet ACTR8002 - ACTR8002 ACTR8002 Datasheet
Privacy Policy | Disclaimer |