| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
EX-F1 SERIES Pipe-mountable Liquid Level Detection Sensor Am
Top Searches for this datasheetSENSORS SEMICONDUCTOR INDUSTRY EX-F1 SERIES Pipe-mountable Liquid Level Detection Sensor Amplifier Built-in FD-F4 FD-F8Y EX-F1 Liquid Leak Liquid Level Sensing Reliable liquid level detection with amplifier built-in low-priced sensor FT-Z8Y Chemical-resistant Conforming Directive Space-saving amplifier built-in type EX-F1 amplifier built-in sensor saves space there need install separate amplifier. price EX-F1 very cost-effective. Easily mountable adjustable Just attach pipe with tying bands. position easily changed with release lever even after mounting, that there need tying bands. Release lever Other Products Position adjustable Easy check operation Indicator operation checked glance from different directions. Operation mode switch Either Light-ON Dark-ON selected switch. This useful check operation during installation because forces output turned even without liquid being inside pipe. Operation indicator (Red) Lights when output APPLICATIONS Detecting liquid level tank Principle Detection When pipe empty, beam reflected from inner surface pipe wall returns beamreceiving part, since difference refractive indexes pipe large. When there liquid pipe, beam enters liquid through wall does return beamreceiving part, since difference refractive indexes pipe liquid small. EX-F1 <Empty pipe> <Filled pipe> beam reflected from inner surface pipe wall returns beam-receiving part. beam passes through wall into liquid. ORDER GUIDE Type Appearance Sensing object Applicable pipe diameter Model Amplifier Built-in Pipe-mountable 16.404 cable length type Liquid (Note (Fluorine resin) equivalently transparent pipe, wall thickness 0.039 Outer dia."6 "0.236 "0.512 EX-F1 (Note EX-F1-C5 Notes: Unclear highly viscous liquid detected stably. sensor with pipes other than above specified. Other Products Chemical-resistant FT-Z8Y Liquid Leak Liquid Level Sensing FD-F4 FD-F8Y EX-F1 SENSORS SEMICONDUCTOR INDUSTRY EX-F1 SENSORS SEMICONDUCTOR INDUSTRY EX-F1 SPECIFICATIONS Type Item Sensing object Amplifier built-in Pipe-mountable EX-F1 Liquid (Note Outer dia. "0.236 "0.512 transparent pipe [PFA (Fluorine resin) equivalently transparent pipe, wall thickness 0.039 (Note 0.020 less Ripple less less open-collector transistor Maximum sink current: Applied voltage: less (between output Residual voltage: less sink current) less sink current) DC-12 DC-13 Switchable either Light-ON (Liquid-absent-ON) Dark-ON (Liquid-present-ON) Incorporated less (lights when output (Industrial environment) condensation icing allowed), Storage: Storage: Sunlight: 10,000 light-receiving face, lncandescent light: 3,000 light-receiving face 50081-2, 50082-2, 60947-5-2 1,000 min. between supply terminals connected together enclosure more, with megger between supply terminals connected together enclosure frequency, 0.75 0.030 amplitude directions hours each m/s2 acceleration approx.) directions five times each Infrared (modulated) Enclosure: Polycarbonate, Tying band: Nylon, Anti-slip tube: Silicone 3-core cabtyre cable, 3.281 long Extension total 164.042 possible with mm2, more, cable. approx. Tying band: pcs., Anti-slip tube: pcs. Model FD-F4 FD-F8Y EX-F1 Liquid Leak Liquid Level Sensing Applicable pipe diameter Repeatability Supply voltage Current consumption Output Utilization category Output operation Short-circuit protection Response time Operation indicator FT-Z8Y Chemical-resistant Pollution degree Ambient temperature (Note Environmental resistance Ambient humidity Ambient illuminance Voltage withstandability Insulation resistance Vibration resistance Shock resistance Emitting element Material Cable Cable extension Weight Accessories Other Products Notes: Unclear highly viscous liquid detected stably. sensor with pipes other than above specified. Liquid being detected should also kept within rated ambient temperature range. CIRCUIT WIRING DIAGRAMS circuit diagram Color code Sensor circuit (Black) Output max. (Blue) Blue (Brown) Load Black Brown Load Wiring diagram Internal circuit Users' circuit Symbols Reverse supply polarity protection diode Surge absorption zener diode output transistor PRECAUTIONS PROPER This product safety sensor. intended designed protect life prevent body injury property damage from dangerous parts machinery. normal object detection sensor. Mounting Mount sensor pipe with attached tying bands anti-slip tubes shown figure below. Make sure that release lever retracted (position figure) before mounting. Fasten tying bands, shown, excess portions. Anti-slip tube Upper side Tying band Refer p.1135l general precautions. Operation mode switch Light-ON (Liquid-absent-ON) Dark-ON (Liquid-present-ON) indicator operation output operation change with setting operation mode switch given table below. Release lever Lower side other tying bands used, dimension shown figure below should 0.098 less. Liquid-absent Liquid-present Lights Lights Position adjustment After mounted pipe with tying bands, sensor position easily adjusted. Adjustment MODE Sensing condition Operation indicator Output operation Light-ON Liquid-absentON Dark-ON Liquid-presentON Liquid-present Liquid-absent Liquid-present Liquid-absent Press Lock release lever original place. Release lever Note: lever mechanism must used only adjust position, tightening tying bands. tying bands tightened while lever open, then lever locked, sensor damaged. DIMENSIONS (Unit: Beam axis 1.063 0.512 Beam axis 0.906 1.142 data dimensions downloaded from SUNX website: http://www.sunx.co.jp/ 0.512 0.315 Operation mode switch 0.157 0.591 Operation indicator (Red) "2.5 "0.098 cable,1 3.281 long Position adjustable Press movable center holders forward loosen tying bands adjust position. Loosen Others during initial transient time after power supply switched this sensor with pipe which transparent. Unclear highly viscous liquid detected. sensor pipe securely, otherwise operation erroneous. Outer Inner wall wall Take care that condenses Liquid drops pipe's sensing surface pipe's inside wall that bubble attaches pipe's inside wall, since affect operation. Bubbles liquid drop flows down across sensing point bubble sticks wall sensing point, operation erroneous. Make sure that bubble arises liquid, that liquid drop present either surface pipe wall. EX-F1 water-proof chemical-resistant. Installation should avoided place where could come direct contact with water chemicals. Other Products Unlock release lever direction arrow). Release lever Chemical-resistant FT-Z8Y Liquid Leak Liquid Level Sensing FD-F4 FD-F8Y EX-F1 Selecting output operation Either Light-ON (Liquidabsent-ON) Dark-ON (Liquid-present-ON) selected with operation mode switch according your application. Operation indicator (Red) Lights when output SENSORS SEMICONDUCTOR INDUSTRY EX-F1 Other recent searchesUL94V-0or94V-2 - UL94V-0or94V-2 UL94V-0or94V-2 Datasheet IDT71V65603 - IDT71V65603 IDT71V65603 Datasheet IDT71V65803 - IDT71V65803 IDT71V65803 Datasheet EN6212B - EN6212B EN6212B Datasheet LB11987 - LB11987 LB11987 Datasheet DCF1300-T0810 - DCF1300-T0810 DCF1300-T0810 Datasheet CM75DY-12H - CM75DY-12H CM75DY-12H Datasheet B5094 - B5094 B5094 Datasheet
Privacy Policy | Disclaimer |