| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
PPS350 *Universal input/ Built-in filter *Optional remote sense m
Top Searches for this datasheetTOTAL POWER INT. SWITCHING MODE 350W CHANNEL POWER SUPPLIES TPS350 SWITCHING MODE 350W CHANNEL POWER SUPPLY PPS350 *Universal input/ Built-in filter *Optional remote sense main output *Optional constant current charger *Optional Power Good signal/ fail signal *Optional remote signal/ Optional cover *Optional±12VDC/±24VDC/±48VDC input *Optional constant current change (for single output) APPLICATIONS *Telecommunications/ Medical instruments *Computer peripherals/ Business machines *Test, Burn-In industrial equipments ELECTRICAL SPECIFICATIONS *Input range-90~264 VAC, auto ranging *Frequency-47~63Hz *Inrush current-45A typical,. Cold start @25,115VAC *Efficiency-65%~85% typical full load *EMI filter- Class conducted, CISPR Class conducted, EN55022 class Conducted *Line regulation- 0.5% typical *FCC part Class *CISPR EN55022, Class *VCCI ,Class *CE,EN 61000-3-2 (Class A)(Optional) INPUT 61000-4-2,-3,-4,-5,-6 SAFETY APPROVAL OUTPUT *Maximum power- 350W with forced (Refer next page) *Hold-up time -10ms typical full load nominal line *Overload protection-Short circuit protection *Overvoltage protection -Main output above nominal output *Ripple/Noise Max. @full load (Optional +/-0.5% inquiry) *UL1950 *Optional 22.2, LEVEL (COMPLY WITH) *TUV EN60950 *Optional 2601 (EMI Class (COMPLY WITH) ENVIRONMENTAL *Operating temperature 50ambient; derate each output 2.5% degree from 50to *Humidity: Operating; non-condensing, *Vibration 10~55 minutes period, minutes along axis *Storage temperature: *Temperature coefficient: 0.05% degree *MTBF demonstrated: >100,000 hours full load 25ambient conditions Power Derating Curve 350W Forced Cooling Output Power 150W (Watts) 100W 200W 175W Natural Convection Cooling 100W Ambient Temperature( TOTAL POWER, INC. TEL:877-646-0900 FAX:978-453-7395 E-mail:sales@total-power.com http://www.total-power.com TOTAL POWER MODEL OUTPUT VOLTAGE RANGE TPS350 CURRENT SWITCHING MODE 350W CHANNEL POWER SUPPLIES PEAK OUTPUT CURRENT(NOTE1) MINIMUM OUTPUT CURRENT TOTAL REGULATION(NOTE3) RIPPLE NOISE %P-P(NOTE2) PEAK OUTPUT POWER(NOTE1) ADJUSTMENT MAXIMUM OUTPUT SINGLE OUTPUT MODEL SELECTION CHART TPS350-10 TPS350-11 TPS350-12 TPS350-13 TPS350-14 TPS350-15 TPS350-16 TPS350-17 TPS350-18 +12V +15V +24V +48V +36V +56V +18V +3.3V ±10% Typical ±10% Typical ±10% Typical ±10% Typical ±10% Typical ±10% Typical ±10% Typical ±10% Typical ±10% Typical 29.2A 23.3A 14.6A 7.3A 9.7A 6.25A 19.4A 33.6A 26.8A 16.8A 8.4A 11.2A 7.2A 22.3A ±1.5% 400W Typical 400W Typical 400W Typical 400W Typical 400W Typical 400W Typical 400W Typical 400W Typical 400W Typical DUAL OUTPUT MODEL SELECTION CHART TPS350-20Y TPS350-21Y TPS350-22Y TPS350-23Y TPS350-24Y TPS350-25Y TPS350-26Y TPS350-27Y TPS350-28Y +12V +24V +12V +3.3V 3.3V ±10% Typical Typical ±10% Typical Typical ±10% Typical Typical ±10% Typical Typical ±10% Typical Typical ±10% Typical Typical ±10% Typical Typical ±10% Typical Typical ±10% Typical Typical 54.6A 18.2A 45.5A 9.1A 54.6A 54.6A 19.5A 19.5A 15.6A 15.6A 62.4A 19.5A 20.8A 10.4A 32.5A 58.5A 58.5A 4.2A 1.4A 3.7A 0.7A 4.2A 4.2A 1.5A 1.5A 1.2A 1.2A 4.8A 1.5A 1.6A 0.8A 2.5A 4.5A 4.5A ±1.5% ±1.5% 400W Typical 400W Typical 400W Typical 400W Typical 400W Typical 400W Typical 400W Typical 400W Typical 400W Typical TRIPLE OUTPUT MODEL SELECTION CHART TPS350-30 ±10% Typical Fixed Fixed ±10% Typical Fixed Fixed ±10% Typical Fixed Fixed ±10% Typical Fixed Fixed ±10% Typical Fixed Fixed ±10% Typical Fixed Fixed ±10% Typical Fixed Fixed ±10% Typical Fixed Fixed ±10% Typical Fixed Fixed 3.5A 3.5A 3.5A 3.5A 3.5A 7.2A 3.5A 3.5A 3.5A 40.3A 16.1A 40.3A 13.8A 40.3A 11.5A 40.3A 9.2A 40.3A 9.2A 40.3A 8.3A 34.5A 17.3A 5.8A 40.3A 13.8A 40.3A 6.9A 3.5A 1.4A 0.35A 3.5A 1.2A 0.35A 3.5A 0.35A 3.5A 1.1A 0.35A 3.5A 0.9A 0.35A 3.5A 0.72A 0.35A 1.5A 0.5A 3.5A 1.2A 0.35A 3.5A 0.35A ±10% ±10% ±10% ±10% ±10% ±10% ±10% ±10% ±10% 400W Typical 400W Typical 400W Typical 400W Typical 400W Typical 400W Typical 400W Typical 400W Typical 400W Typical +12V TPS350-31 +12V TPS350-32 +15V -15V TPS350-33Y +15V TPS350-34Y +15V -12V TPS350-35 +24V -12V TPS350-36 +12V TPS350-37 +12V +24V TPS350-38Y +24V +48V TOTAL POWER, INC. TEL:877-646-0900 FAX:978-453-7395 E-mail:sales@total-power.com http://www.total-power.com TOTAL POWER MODEL OUTPUT VOLTAGE RANGE PPS350 CURRENT SWITCHING MODE 350W CHANNEL POWER SUPPLIES PEAK OUTPUT CURRENT(NOTE1) MINIMUM OUTPUT CURRENT TOTAL REGULATION(NOTE3) RIPPLE NOISE %P-P(NOTE2) PEAK OUTPUT POWER(NOTE1) ADJUSTMENT MAXIMUM OUTPUT TRIPLE OUTPUT MODEL SELECTION CHART +3.3V TPS350-39 ±10% Typical Fixed Fixed 40.3A 3.5A 0.7A ±10% ±1.5% 400W Typical +12V QUAD OUTPUT MODEL SELECTION CHART TPS350-40 ±10% Typical Fixed Fixed Typical ±10% Typical Fixed Fixed Typical ±10% Typical Fixed Fixed Typical ±10% Typical Fixed Fixed Typical ±10% Typical Fixed Fixed Typical ±10% Typical Fixed Fixed Typical ±10% Typical Fixed Fixed Typical ±10% Typical Fixed Fixed Typical ±10% Typical Fixed Fixed Typical ±10% Typical Fixed Fixed 3.5A 2.5A 6.5A 2.5A 3.5A 2.5A 1.5A 1.5A 40.3A 13.8A 2.3A 40.3A 11.5A 4.6A 3.5A 40.3A 8.1A 4.5A 3.5A 28.8A 4.6A 2.9A 7.5A 28.8A 4.6A 3.5A 4.6A 28.8A 12.7A 2.9A 40.3A 3.5A 6.9A 2.9A 34.5A 4.6A 28.8A 5.8A 5.2A 7.5A 40.3A 6.9A 3.5A 1.2A 0.35A 0.2A 3.5A 0.4A 0.3A 3.5A 0.7A 0.3A 0.3A 2.5A 0.4A 0.25A 0.65A 2.5A 0.4A 0.3A 0.4A 2.5A 1.1A 0.25A 0.35A 3.5A 0.3A 0.6A 0.25A 0.15A 0.15A 0.4A 2.5A 0.2A 0.2A 0.4A 3.5A 0.6A ±10% ±10% ±10% ±10% ±10% ±10% ±10% ±10% ±10% ±10% ±1.5% 400W Typical 400W Typical 400W Typical 400W Typical 400W Typical 400W Typical 400W Typical 400W Typical 400W Typical 400W Typical +12V +12V +12V +15V +12V +24V +12V +48V +12V -12V +24V +12V +48V +15V +48V +24V +48V +3.3V +12V TPS350-41 TPS350-42 TPS350-43 TPS350-44 TPS350-45 TPS350-46 TPS350-47Y TPS350-48Y TPS350-49 Typical 6.9A 0.6A NOTES: Peak loads lasting seconds with maximum duty cycle acceptable. Please contact need special peak load. Maximum peak peak noise expressed percentage output voltage, 20MHz bandwidth, input less nominal line, 0.1F Cap. outputs. Loading test conditions outputs minimum, middle maximum loads. Special cross loading requirement welcomed. Detailed engineering specification each model available inquiry. Special output voltage/current inquiry welcomed. Specifications subject change without notice. derated input version; derated input version; derated additional cover. TOTAL POWER, INC. TEL:877-646-0900 FAX:978-453-7395 E-mail:sales@total-power.com http://www.total-power.com Other recent searchesUG388 - UG388 UG388 Datasheet SHD3251 - SHD3251 SHD3251 Datasheet SG1577 - SG1577 SG1577 Datasheet SAK16 - SAK16 SAK16 Datasheet OSY5MAA201A - OSY5MAA201A OSY5MAA201A Datasheet CSQ-3402Y - CSQ-3402Y CSQ-3402Y Datasheet 3403Y - 3403Y 3403Y Datasheet BHC68 - BHC68 BHC68 Datasheet AN221D04 - AN221D04 AN221D04 Datasheet AN120E04 - AN120E04 AN120E04 Datasheet AN121E04 - AN121E04 AN121E04 Datasheet AN220E04 - AN220E04 AN220E04 Datasheet AN221E04 - AN221E04 AN221E04 Datasheet AN221D04-EVAL - AN221D04-EVAL AN221D04-EVAL Datasheet
Privacy Policy | Disclaimer |