| The Datasheet Archive - 100 Million Datasheets from 7500 Manufacturers. |
E-Cu-rope Siliconcoat E-Cu-rope Siliconcoat yellow E-Cu-cable
Top Searches for this datasheetMarketing Information E-Cu-rope Siliconcoat E-Cu-rope Siliconcoat yellow E-Cu-cable Plug Silicon tube SW27 June 1996 Periodische Dauergrenzstrom Grenzlastintegral Kritische Stromsteilheit Kritische Spannungssteilheit Elektrische Eigenschaften Werte repetitive peak forward off-state reverse voltages non-repetitive peak forward off-state voltage non-repetitive peak reverse voltage on-state current average on-state current surge current t-value critical rate rise on-state current critical rate rise off-state voltage Electrical properties Maximum rated values -40°C.t -40°C.t +25°C.t VDRM VRRM VDSM VDRM VRSM VRRM ITRMSM 6300 5500 198000 151000 A/µs 100°C 45°C, 45°C, 67%, vL=10 0,75 G/dt =0,75 A/µs 5.Kennbuchstabe/5th letter 5.Kennbuchstabe/5th letter ITAVM ITSM (di/dt)cr (dv/dt)cr V/µs 1000 V/µs Charakteristische Werte Schleusenspannung Ersatzwiderstand Nicht Steuerstrom Nicht Steuerspannung Haltestrom Einraststrom Freiwerdezeit Characteristic values on-state voltage threshold voltage slope resistance gate trigger current gate trigger voltage gate non-trigger current gate non-trigger voltage holding current latching current forward off-state reverse currents gate controlled delay time circuit commutated turn-off time °C,v =0,75 =0,75 A/µs, max, VDRM VRRM tvj=25°C, =0,75 A,di G/dt =0,75 A/µs ITAVM 0,67 dvD/dt V/µs, T/dt A/µs Kennbuchstabe letter max. max. typ. VT(TO) max. 0,85 max. max. max. max. max. max. Innerer Thermische Eigenschaften thermal resistance, junction case max. junction temperature operating temperature storage temperature Thermal properties =180° RthJC tstg max. 0,15 °C/W max. 0,14 °C/W -40.+140 -40.+150 Betriebstemperatur Lagertemperatur Si-Elemente Druckkontakt Anzugsdrehmoment Gewicht Kriechstrecke Feuchteklasse Schwingfestigkeit Mechanische Eigenschaften Si-pellet with pressure contact tightening torque weight creepage distance humidity classification vibration resistance outline Mechanical properties design 40040 892-204B3/TO 94/TO Titelseite Front page 20.30 typ. 1000 +140°C +25°C Bild Fig. On-state characteristics f(vT) Typische Kennlinien Typical characteristics Grenzkennlinien Limiting characteristics PTAV 120° 180° [°C] 120° 180° ITAV ITAVM Bild Fig. On-state power loss PTAV f(ITAV) Parameter: Current conduction angle Bild Fig. Maximum allowable case temperature f(ITAVM) [°C] [°C] 120° 180° 120° 180° ITAVM ITAVM Bild Fig. Maximum allowable cooling medium temperature f(ITAVM) Natural air-cooling Heatsink: KL42 Bild Fig. Maximum allowable cooling medium temperature f(ITAVM) Forced air-cooling Heatsink: KL42 [°C] [°C] 120° 180° 120° 180° ITAVM ITAVM Bild Fig. Maximum allowable cooling medium temperature f(ITAVM) Natural air-cooling Heatsink: KL91 Bild Fig. Maximum allowable cooling medium temperature f(ITAVM) Forced air-cooling Heatsink: KL91 PTAV 120° 180° [°C] 120° 180° ITAVM ITAV Bild Fig. On-state power loss PTAV f(ITAV) Parameter: Current conduction angle Bild Fig. Maximum allowable case temperature f(ITAVM) [°C] [°C] 120° 180° 120° 180° ITAVM ITAVM Bild Fig. Maximum allowable cooling medium temperature f(ITAVM) Natural air-cooling Heatsink: KL42 Bild Fig. Maximum allowable cooling medium temperature f(ITAVM) Forced air-cooling Heatsink: KL42 [°C] [°C] 120° 180° 120° 180° ITAVM ITAVM Bild Fig. Maximum allowable cooling medium temperature f(ITAVM) Natural air-cooling Heatsink: KL91 Bild Fig. Maximum allowable cooling medium temperature f(ITAVM) Forced air-cooling Heatsink: KL91 0,25 ZthJC [°C/W] 0,20 0,15 0,10 120° 180° 0,05 Bild Fig. Transienter innerer sinus- Stromverlauf Transient thermal impedance, junction case sinusoidal square wave current ZthJC f(t) ITAV(vor) ITAV(vor) IT(OV) [kA] IT(OV) [kA] Bild Fig. Overload on-state current IT(OV) f(t) Natural cooling, 45°C Heatsink: KL42 Parameter: Vorlaststrom Pre-load current ITAV(vor) Bild Fig. Overload on-state current IT(OV) f(t) Forced air-cooling, 35°C Heatsink: KL42, Parameter: Vorlaststrom Pre-load current ITAV(vor) ITAV(vor) ITAV(vor) IT(OV) [kA] IT(OV) [kA] Bild Fig. Overload on-state current IT(OV) f(t) Natural cooling, 45°C Heatsink: KL91 Parameter: Vorlaststrom Pre-load current ITAV(vor) Bild Fig. Overload on-state current IT(OV) f(t) Forced air-cooling, 35°C Heatsink: KL91, Parameter: Vorlaststrom Pre-load current ITAV(vor) 1000 ITAV(vor) 1000 ITAV(vor) ITINT ITAV(vor) ITINT ITAV(vor) ITAV(vor) ITINT ITAV(vor) ITINT 10-1 ITINT 10-1 5102 ITINT Bild Fig. Aussetzbetrieb Max. allowable on-state current intermittent operation ITINT =f(ED) Natural cooling, 45°C Heatsink: KL42 Parameter: Spieldauer Cycle duration Vorlaststrom Pre-load current ITAV(vor) 1000 ITAV(vor) Bild Fig. Aussetzbetrieb Max. allowable on-state current intermittent operation ITINT =f(ED) Forced air-cooling, 35°C Heatsink: KL42 Parameter: Spieldauer Cycle duration Vorlaststrom Pre-load current ITAV(vor) 1000 ITAV(vor) =200 ITINT ITAV(vor) ITINT ITAV(vor) ITAV(vor) ITINT ITAV(vor) ITINT 10-1 ITINT 10-1 5102 ITINT 1000 Bild Fig. Aussetzbetrieb Max. allowable on-state current intermittent operation ITINT =f(ED) Natural cooling, 45°C Heatsink: KL91 Parameter: Spieldauer Cycle duration Vorlaststrom Pre-load current ITAV(vor) Bild Fig. Aussetzbetrieb Max. allowable on-state current intermittent operation ITINT =f(ED) Forced air-cooling, 35°C Heatsink: KL91 Parameter: Spieldauer Cycle duration Vorlaststrom Pre-load current ITAV(vor) IT(OV)M [kA] IT(OV)M [kA] 35°C, 35°C, 45°C, 45°C, 10-1 Bild Fig. Grenzstrom Max. overload on-state current T(OV)M f(t), VRRM Natural cooling, 45°C, Forced air-cooling, 35°C Heatsink: KL42 Belastung Surge current occurs: Leerlauf No-load conditions Betrieb Dauergrenzstrom During operation max. average on-state current ITAVM Bild Fig. Grenzstrom Max. overload on-state current IT(OV)M f(t), VRRM Natural cooling, 45°C, Forced air-cooling, 35°C Heatsink: KL91 Belastung Surge current occurs: Leerlauf No-load conditions Betrieb Dauergrenzstrom During operation max. average on-state current ITAVM [µs] 25°C 1005 10-2 10-1 10-1 Bild Fig. Steuercharakteristik Gate characteristic with trigging areas f(iG), Parameter: [ms] Steuerimpulsdauer Puls duration Spitzensteuerleistung Maximum allowable peak gate power Bild Fig. Gate controlled delay time f(iGM), 25°C, diG/dt iGM/1µs Maximaler Verlauf Limiting characteristic Typischer Verlauf Typical characteristic [µAs] 1000 Bild Fig. abkommutierenden Stromsteilheit Recovered charge versus rate decay forward on-state current f(di/dt) max, VRRM, VRRM angegebene Verlauf aller Elemente These curves valid devices Parameter: On-state current i -di/dt [A/µs] Other recent searchesPE80Q04N - PE80Q04N PE80Q04N Datasheet MC355S - MC355S MC355S Datasheet MC3458 - MC3458 MC3458 Datasheet MC3358 - MC3358 MC3358 Datasheet FMR21N50ES - FMR21N50ES FMR21N50ES Datasheet
Privacy Policy | Disclaimer |