500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Top Results

Part Manufacturer Description Datasheet BUY
HSP50214BVI Intersil Corporation Programmable Downconverter; MQFP120; Temp Range: See Datasheet visit Intersil Buy
HSP50214BVIZ Intersil Corporation Programmable Downconverter; MQFP120; Temp Range: See Datasheet visit Intersil Buy
HSP50214BVC Intersil Corporation Programmable Downconverter; MQFP120; Temp Range: See Datasheet visit Intersil Buy
HSP50214BVCZ Intersil Corporation Programmable Downconverter; MQFP120; Temp Range: See Datasheet visit Intersil Buy
CP82C50A-5 Intersil Corporation CMOS Asynchronous Communications Element; PDIP40, PLCC44; Temp Range: See Datasheet visit Intersil Buy
ISL6115AIBZ-T Intersil Corporation 12V Power Distribution Controllers; SOIC8; Temp Range: See Datasheet visit Intersil Buy

datasheet of blown fuse indicator

Catalog Datasheet MFG & Type PDF Document Tags

weidmuller fuse

Abstract: weidmuller fuse slug but µA! This makes the circuit safe and still provides an excellent visual indication of a blown fuse , Datasheet ASK 1 / KDKS 1 25 Years old and still the most innovative and flexible fuse terminal , shield. One of the unique features of the versions with LED indicator is the high impedance circuit. Located in parallel with the fuse, the LED indicator is energized when the fuse fails. Since this circuit , (blown fuse), hinge -, beige lever, UL94-V2: 24V 980272 120V 980276 230V 980278 with LED indication (fuse
Weidmüller
Original
weidmuller fuse weidmuller fuse slug ask-1 ASK1LD MEXICO FUSE of blown fuse indicator UL94-V0
Abstract: Cartridge Fuse Holders Enclosed Fuseholders > Panel Mounted 344/348 Series Blown Fuse , ) Product Characteristics Compatible Fuses For 3AG Type Fuses Features Low profile design Blown fuse indicator Electrical 348 Series: Rated at 15 amps for any voltage up to 250 volts. 344 , designing indicating type fuseholders into a circuit, consideration should be given to the resistance of fractional amperage fuses and the parallel resistance of the indicator lamp and its resistor. Mounting Littelfuse
Original

IEC60947-7

Abstract: 1SNK 505 061 R0000 -7-3 standard. The wiring of the terminal block is facilitated and can be done when the fuse holder is in closed position. -Easy blown fuse control with the ZS4-SF-R1 and ZS4-SF-R3 available with blown fuse indicator 24-60 V or 110-230 V for quick identification of fuse failures, with low leakage current (< 0.5 , . 40 ZS4-SF-R1. . With fuse indicator 24-60 V. 41 ZS4-SF-R3. . With fuse indicator 115-250 V
-
Original
S0201 IEC60947-7 1SNK 505 061 R0000 HTP500 JB26-10 MC512 D0201 DIN3-TH35 R0000 C0201 MC812

10-60Vac

Abstract: ) have undergone a little face lift. · BFI (Blown Fuse Indicator) circuit using new high efficiency, high , . Derating required based on inline resistance of fuse used. Check with fuse manufactureer for details , cross-connection bridges. Order data Version No LED Indication 10-60V ac/dc Blown Fuse Indication Hinge Negative 10-60V ac/dc Blown Fuse Indication Hinge Positive 100-250V ac/dc Blown Fuse Indication Hinge Negative 100-250V ac/dc Blown Fuse Indication Hinge Positive Qty. Order No. 100 0474560000 ASK1EN/SMT10
Weidmüller
Original
10-60Vac 111HA 141HA 240HA 495HA 630HA 152HA

MEXICO FUSE

Abstract: 0545300000 ) have undergone a little face lift. · BFI (Blown Fuse Indicator) circuit using new high efficiency , required based on inline resistance of fuse used. Check with fuse manufactureer for details. Rated , bridges. Order data Type Version No LED Indication 10-60V ac/dc Blown Fuse Indication Hinge Negative 10-60V ac/dc Blown Fuse Indication Hinge Positive 100-250V ac/dc Blown Fuse Indication Hinge Negative 100-250V ac/dc Blown Fuse Indication Hinge Positive Qty. Order No. 100 0474560000 ASK1EN
Weidmüller
Original
0545300000 9118290001 SMT10-60VUC 250Vuc datasheet of blown fuse indicator transistor marking QB 172HA 337HA 352HA 383HA 10-60V 100-250V
Abstract: Technical Datasheet 1SNK162045D0201 Catalogue Page 1SNK162022S0201 ZK2.5-SF-R PI-Spring Terminal Blocks For 5x20 fuses - with blown fuse indicator - Protect your circuits with 5x20 fuse terminal blocks compliant with IEC 60947-7-3 standard (fuse not supplied with the terminal blocks), - , .5-S-R1 disconnect terminal blocks, - Quickly identify the defective circuit thanks to the blown fuse indicator , Classification Group Category Protection Method Ex e: increased security In the presence of explosive ABB Semiconductors
Original
1SNK162091V0014 1SNK500181F0000 1SNC500511 F0000 1SNK706411R0000 1SNK706412R0000

JTD60ID

Abstract: LR29862 POWR-GARD® Fuse Datasheet UL Class J JTD_ID Series Indicator ® POWR-PRO ® FUSES , JTD_ID 60 JTD60ID non-indicating JTD 60 JTD60 The Littelfuse POWR-PRO JTD_ID Indicator Class J fuse provides visual blown fuse indication and maximum protection in a compact package. The , www.littelfuse.com 1 © JUNE 2011 Littelfuse POWR-GARD Products POWR-GARD® Fuse Datasheet UL Class J , © JUNE 2011 Littelfuse POWR-GARD Products POWR-GARD® Fuse Datasheet UL Class J Peak Let-Thru
Littelfuse
Original
LR29862 E81895 0JTD060
Abstract: Cartridge Fuse Holders Enclosed Fuseholders > Panel Mounted 344 Series Blown Fuse Indicating , be given to the resistance of fractional amperage fuses and the parallel resistance of the indicator , Parts LOCK WASHER HEX NUT RUBBER WASHER .11" DIA. .94" .81" 2.38" MAXIMUM WITH FUSE , .11" DIA. .94" Ordering Information 1.10" 2.67" MAXIMUM WITH FUSE INSTALLED Catalog , .002 amp Clear 344 000 Series (Bar Knob) 344 006 Additional Information Datasheet Littelfuse
Original
E14721
Abstract: POWR-GARD® Fuse Datasheet JTD SERIES INDICATOR ® POWR-PRO ® FUSES 600 , ) www.littelfuse.com 1 of 3 © 2012 Littelfuse POWR-GARD® Products Rev: 081712 POWR-GARD® Fuse Datasheet , ® Products Rev: 081712 POWR-GARD® Fuse Datasheet JTD SERIES CLASS J FUSE Current-Limiting Effects of , Material Approvals Description The Littelfuse POWR-PRO® JTD_ID Indicator Class J fuse provides visual blown fuse indication and maximum protection in a compact package. The current-limiting time Littelfuse
Original
Abstract: POWR-GARD® Fuse Datasheet JTD Series Indicator ® POWR-PRO ® FUSES 600 , The Littelfuse POWR-PRO® JTD_ID Indicator Class J fuse provides visual blown fuse indication and , www.littelfuse.com 2 of 3 © 2013 Littelfuse POWR-GARD® Products Rev: 103013 POWR-GARD® Fuse Datasheet JTD SERIES Class J FUSE Current-Limiting Effects of JTD_ID (600 V) Fuses Short Circuit Current â , ® Products Rev: 103013 POWR-GARD® Fuse Datasheet jTD dimensions and current-limiting effects Littelfuse
Original

din 68-150

Abstract: LFJ60 POWR-GARD® Fuse Datasheet JTD Series Indicator ® POWR-PRO ® FUSES 600 VAC · , ) www.littelfuse.com 1 of 3 © 2012 Littelfuse POWR-GARD® Products Rev: 081712 POWR-GARD® Fuse Datasheet , Material Approvals Description The Littelfuse POWR-PRO® JTD_ID Indicator Class J fuse provides visual blown fuse indication and maximum protection in a compact package. The current-limiting time delay JTD_ID offers a patented design which reduces nuisance fuse openings. Country of Origin AC : 600 V
Littelfuse
Original
din 68-150 LFJ60

NH3 fuse aM

Abstract: NH fuse 500 A All NH fuse links incorporate a blown fuse indicator Description Littelfuse ® European style NHfuse links are designed for the protection of conductors and motors. The gL-gG characteristic fuse , POWR-GARD® Fuse Datasheet NH Fuse links 500 Volts · 2-630 A Specifications Voltage Rating , aM characteristic fuse links are used for the short-circuit protection of motors and switchgear. They , Littelfuse POWR-GARD® Products Rev: 013013 POWR-GARD® Fuse Datasheet NH Fuse links DIMENSIONS
Littelfuse
Original
NH00CG10 NH0G63 NH3 fuse aM NH fuse 500 A FUSE base NH2 690 V AC 315 A Fuse NH2 fuse aM a 7800 NH1CG25 NH00C NH00CG2 NH00CG4 NH00CG6

UL-94-V0 wemid

Abstract: 0430700000 Datasheet W S I F u s e Te r m i n a l s w i t h L o w C u r re n t S t a t u s I n d i c a t i o n Weidmuller offers versions of the WSI fuse terminals with low current blown fuse indication (BFI). The BFI circuit is located in parallel with the fuse so that a current goes through the indicator only when the fuse blows. As this current is an unwanted off-state leakage current it is important , lever. If the fuse of the LED variants is defective, the downstream circuit is still under current
Weidmüller
Original
UL-94-V0 wemid 0430700000 1012300001 94-V0 10-36VAC/DC 30-70VAC/DC 60-150VAC/DC 250VAC/110VDC 5/10-LIT0914
Abstract: Datasheet W S I F u s e Te r m i n a l s w i t h L o w Current Status Indication Weidmuller offers versions of the WSI fuse terminals with low current blown fuse indication (BFI). The BFI circuit is located in parallel with the fuse so that a current goes through the indicator only when the fuse blows. As this current is an unwanted off-state leakage current it is important that the level be , disconnected by opening the disconnect lever. If the fuse of the LED variants is defective, the follow-on Weidmüller
Original

1050000000

Abstract: WSI-6 Datasheet W S I F u s e Te r m i n a l s w i t h L o w C u r re n t S t a t u s I n d i c a t i o n Weidmuller offers versions of the WSI fuse terminals with low current blown fuse indication (BFI). The BFI circuit is located in parallel with the fuse so that a current goes through the indicator only when the fuse blows. As this current is an unwanted off-state leakage current it is important , lever. If the fuse of the LED variants is defective, the downstream circuit is still under current
Weidmüller
Original
1050000000 WSI-6 5/09-LIT0914

101130000

Abstract: UL-94-V0 wemid Datasheet W S I F u s e Te r m i n a l s w i t h L o w Current Status Indication Weidmuller offers versions of the WSI fuse terminals with low current blown fuse indication (BFI). The BFI circuit is located in parallel with the fuse so that a current goes through the indicator only when the fuse , disconnected by opening the disconnect lever. If the fuse of the LED variants is defective, the follow-on , : www.weidmuller.com.mx WSI 6 LD and WSI 6/2 LD xyzljsdöaklsd WSI 6 LD with LED indicator for DC or AC voltage
Weidmüller
Original
101130000 DIN 2510 043060 101230000
Abstract: demands. Plated End Caps Blown Fuse Indicator Assembly Precision Formed Short Circuit Element , Littelfuse.com 2 of 3 © 2013 Littelfuse POWR-GARD® Products Rev: 040913 POWR-GARD® Fuse Datasheet , POWR-GARD® Fuse Datasheet Class RK1 ­ LLNRK · LLSRK · LLSRK_ID Series FUSES 250/600 VAC , POWR-GARD® Products Rev: 040913 POWR-GARD® Fuse Datasheet Class RK1 ­ LLNRK · LLSRK · LLSRK_ID , above are Indicator® fuses. *75 A is only available for the 600 V. 600 V type Description RK1 Littelfuse
Original
LLSRK060ID LLSRK060 LLNRK080 LSRK060 LNRK080
Abstract: demands. Plated End Caps Blown Fuse Indicator Assembly Precision Formed Short Circuit Element , www.littelfuse.com 2 of 3 © 2012 Littelfuse POWR-GARD® Products Rev: 100112 POWR-GARD® Fuse Datasheet , POWR-GARD® Fuse Datasheet Class RK1 ­ LLNRK · LLSRK · LLSRK_ID Series FUSES 250/600 VAC , Littelfuse POWR-GARD® Products Rev: 100112 POWR-GARD® Fuse Datasheet Class RK1 ­ LLNRK · LLSRK · , above are Indicator® fuses. *75 A is only available for the 600 V. 600 V type Description RK1 Littelfuse
Original

043060000

Abstract: weidmuller fuse Blown fuse indication by means of LED voltage ranges (10 - 250 V) · Combi-foot for mounting on TS 32 and TS 35 DIN-rails (WSI 4/2 only) · Special interlocking of levers for multiple phase disconnection · , Datasheet Fuse terminal 5 x 20 mm and 1 1/4" x 1/4" with screw connection technology (clamping yoke) WSI 4, 5 x 20 mm WSI 4/2, 1 1/4" x 1/4" NEW The new WSI 4 and 4/2 fuse terminal series , 1880390000 Accessories Fuse cartridges 1 1/4" x 1/4" without indicator 33 kA breaking capacity (F) = fast
Weidmüller
Original
043060000 20/1A/F 20/2A/F 5X100 5M-LIT0607

EW35

Abstract: 02958 Blown fuse indication by means of LED voltage ranges (10 - 250 V) · Combi-foot for mounting on TS 32 and TS 35 DIN-rails (WSI 4/2 only) · Special interlocking of levers for multiple phase disconnection · , Datasheet Fuse terminal 5 x 20 mm and 1 1/4" x 1/4" with screw connection technology (clamping yoke) WSI 4, 5 x 20 mm WSI 4/2, 1 1/4" x 1/4" NEW The new WSI 4 and 4/2 fuse terminal series , : www.weidmuller.com Fuse terminal WSI 4 Fuse terminal 5 x 20 mm 4 mm2 WSI 4/2 Fuse terminal 1 1/4" x 1/4
Weidmüller
Original
EW35 02958 Weidmuller TS35x7.5 GZ Series TS32x15 CLASS J blown fuse indicator
Showing first 20 results.