500 MILLION PARTS FROM 12000 MANUFACTURERS

Datasheet Archive - Datasheet Search Engine

 

contactor 50 A

Catalog Datasheet MFG & Type PDF Document Tags
Abstract: A Typical Contactor Drop-out Time Settings Typical Contactor Drop-out Time Settings (Table A , application with a Bulletin 1502 contactor by a third party (OEM). Scope This document applies to , contactor pick-up time (at a given supply voltage) ensures repeatable performance Selectable vacuum , IntelliVAC with a newer one, note that the Module and Contactor Status outputs may function differently , coordinate with the power supply and contactor. The fuse ratings shown in Table 3.A allow the passage of ... Rockwell Automation
Original
datasheet

46 pages,
630.9 Kb

1503-UM052C-EN-P Allen-Bradley bulletin 1502 ALLEN BRADLEY DIPS 1503-UM051 Allen-Bradley SMC 150 series B 1503-UM05 basic wiring diagram contactor relay contactor wiring diagrams EH 80 contactor 48 VDC interposing relay 80158 contactor 1503VC timer contactor 1503VC INTELLIVAC 1503VC wiring diagram contactor 1503VC Allen-Bradley bulletin 1500 1503VC contactor wiring diagram with timer 1503VC 1503VC 1503VC TEXT
datasheet frame
Abstract: ) < 40oC A 25 25 32 45 50 50 60 Rated making capacity Irms conforming to IEC , 32 45 50 50 60 Rated making capacity Irms conforming to IEC-947-4 IEC-947-4 A 250 , operating coil Selection 3 Pole Contactor with AC operating coil Maximum Current Inductive AC-3 A Resistive AC-1 A Maximum HP Aux. Contacts Coil Built-in contactor per contactor Voltage RS Contactor Stock No. 50/60Hz NC 120V 230V 200V 230V 480V 600V N O Single Phase Three Phase 9 ... Original
datasheet

14 pages,
627.61 Kb

IEC 158-1, VDE 0660 CONTACTORS 230V AC-3 IEC60947-4 instantaneous auxilliary contact contactor coils 220v BS5424 IEC 158-1 VDE 0660 bs5424 CONTACTORS 230V AC-32A contactor coils 24v VDE0660 nfc63110 DC contactor 220V iec 947-4 JEM1038 32A 4 pole relay 230v ac NFC63-110 NFC-63110 IEC 158-1 VDE 0660 VDE 0660 iec 158-1 TEXT
datasheet frame
Abstract: 400 A Medium Voltage Contactor User Manual Maintenance Chapter 4 Tool Requirements , contactor consists of three vacuum bottles. An electro-magnet assembly and a mechanical linkage are used to , opens the contactor. Note: The contactor requires external control relays and a rectification circuit , contactor operates in much the same way as the electrically held with only a few exceptions. · When the , hold-in coil is not supplied). · Once the contactor is closed, a spring-loaded mechanism moves a roller ... Rockwell Automation
Original
datasheet

54 pages,
2869.33 Kb

Allen-Bradley 800t-xd2 contact block IEC60470 basic wiring diagram contactor wiring diagram starter fvnr 1502-UM050C-EN-P FVNR contactor 3 phase 1502-V4DBDA-1 dc relay economizing coil ac contactor AEROSHELL 43 contactor JHP-70A mitsubishi contactor Allen-Bradley bulletin 1502 wiring diagram contactor TEXT
datasheet frame
Abstract: 45-45 45-45 45-45 25-25 25-25 25-25 25-25 (1) A new 45 mm ­ 50 A version will be available at , I(A) 5 20 15 10 5 0 0 10 20 30 40 50 60 70 80 t (°C) 0 , 60 70 80 t (°C) GNR20A GNR20A I(A) 25 20 15 10 5 0 0 10 20 30 40 50 , Relay Contactor Part numbers Type 22.5 mm Current (A) 20 20 20 20 20 20 20 20 30 30 , 20 30 40 50 60 70 80 t (°C) GNR30A GNR30A I(A) 35 30 25 20 15 10 5 0 18 ... Crouzet
Original
datasheet

28 pages,
1863.9 Kb

Semiconductor Relay Crouzet 84130102 84130158 crouzet Crouzet 89 750 150 GNR25DCZ 180-280V EN 60947-4-3 GNR10DCZ 84130116 84130103 Relay c GNR20DMZ TEXT
datasheet frame
Abstract: 3RA13 3RA13, 3RA14 3RA14 Contactor Assemblies 3RA14 3RA14 Contactor Assemblies for Wye-Delta Starting 3RA14 3RA14 complete units, 3 . 75 kW Overview A dead interval of 50 ms on reversing is already integrated in the time relay function. Note: Contactor assemblies for wye-delta starting in special , K3 delta contactor. A solid-state time-delay auxiliary switch block is snapped onto the front of the complete contactor assemblies, size S00 up to 7.5 kW, while a timing relay is mounted onto the ... Original
datasheet

2 pages,
113.46 Kb

3RA13 46-4JB0 3RT10 65 3RT19 star delta connection siemens 3rb20 3RT10 3RT10 SIEMENS Installation 3RB29 3RT10 SIEMENS siemens contactor wye-delta siemens relays 3RU11 SIEMENS MOTOR CONTACTOR OVERLOAD BLOCK Siemens 3RT10 3RA14 siemens star delta contactor siemens trip relay 241 3RB20 SIEMENS siemens contactor 3rt10 TEXT
datasheet frame
Abstract: A Typical Contactor Drop-out Time Settings Typical Contactor Drop-out Time Settings (Table A , application with a Bulletin 1502 contactor by a third party (OEM). Scope This document applies to the , A wide range of supply voltage (110 ­ 240 V AC 50/60 Hz, 110 - 250 V DC) allows implementation in multiple applications Consistent vacuum contactor pick-up time (at a given supply voltage) ensures , . When replacing an older series of IntelliVAC with a newer one, note that the Module and Contactor ... Rockwell Automation
Original
datasheet

48 pages,
607.1 Kb

ALLEN BRADLEY DIPS 1503-UM053A-EN-P 48 VDC interposing relay 1503-UM051C-EN-P timer contactor Allen-Bradley bulletin 1502 contactor Allen-Bradley SMC 150 series B relay contactor wiring diagrams 1503VC Allen-Bradley bulletin 1500 EH 80 contactor contactor wiring diagram with timer INTELLIVAC wiring diagram contactor TEXT
datasheet frame
Abstract: A Typical Contactor Drop-out Times Table A.1 ­ Contactor Drop-out Times , application with a Bulletin 1502 contactor by a third party (OEM). Description IntelliVAC is an , Features A wide range of supply voltage (110 ­ 240 V AC 50/60 Hz, 110 - 250 V DC) allows implementation in multiple applications Consistent vacuum contactor pick-up time (at a given supply voltage , coordinate with the power supply and contactor. The fuse ratings shown in Table 3.A allow the passage of ... Allen-Bradley
Original
datasheet

44 pages,
538.11 Kb

1502UM052 catalog for capacitor duty contactor 4001 EH INTELLIVAC 80158-779-52-R microcontroller based ac motor starter wiring diagram contactor 80158 80026-430-01-R BMC2 1503-UM051C-EN-P 1503VC 1503VC 80158-779-51-R Allen-Bradley bulletin 1502 1503VC-BMC3 80174-902-14-R 1502-UM052A-EN-P contactor wiring diagram with timer Allen-Bradley bulletin 1500 TEXT
datasheet frame
Abstract: no. 31, 22, 13 contactor arrangements with a 4-pole auxiliary switch block, terminal markings in acc. with DIN EN 50 005 contactor arrangements with a 4-pole auxiliary switch block, terminal , . with EN 50 012 or EN 50 005) 1-pole auxiliary switch block (a maximum of 4 can be snapped on , acc. with EN 50 012: 3RT101 3RT101 Contactor (Frame size S00) A1(+) 1 A1(+) 1 3 5 13 21 31 43 , . · The minimum on-time is 200 ms. · To dampen switching overvoltages of the contactor coil, a ... Original
datasheet

41 pages,
2069.7 Kb

3RT192 3RT1916-2D 3RT103 3RT102 3RH1140 3RT1926-2E 3RT19 3RT107 3RT104 3RH1921-1EA 3RH19 21 3RH1921-1CD01 3rh1921-1 3RT1926 3RH1911-1GA22 3RA1954-2A 3RH1911-1FA22 3RH1921 TEXT
datasheet frame
Abstract: compatible contacts • Mutual positive guidance to the main contactor poles (excluding L types) â , side: 6 total. • True DC Coil contactors - max. 4 N.O. contacts on the front of the contactor, or , the contactor 1-pole (typical) • Snap-on design - mounts without tools • Electronic , guidance to the main contactor poles (excluding L-types) 2-pole (typical) ➊ Max. number of , contactor, 2-N.O. contacts on the side, 4-N.C. front or side: 6 total. • DC Coil contactors - max. 4 N.O ... Sprecher + Schuh
Original
datasheet

12 pages,
1034.79 Kb

CA31210 TEXT
datasheet frame
Abstract: delays in a range of settings q Mechanical latch blocks to hold the contactor in with only a pulsed , in this range. Each contactor has a range of features: q Each contactor has one N/O auxiliary contact with a thermal rating (Ith) of 10A. Each contactor 22kW and above has an additional N/C auxiliary , separately from the contactor. The adaptor can be DIN rail mounted or bolted to a backplate. 7 , allow a 24Vdc low level signal from a PLC to switch the control voltage of the contactor ... RS Components
Original
datasheet

10 pages,
107.55 Kb

OVERLOAD lr2-d13 Starting Current 15kW Motor 440v telemecanique D range contactors la1 dn 22 24V 5A VDE RELAY telemecanique telemecanique VDE 0660 telemecanique IEC 158-1 solid state timer relays telemecanique VDE 0660 iec 947 IEC 158-1 VDE 0660 LR2D13 telemecanique lr2d13 overload contactor LR2-D13 LR2-D13 Telemecanique VDE 0660 - 107 LR2-D13 telemecanique LR2-D13 TEXT
datasheet frame

Archived Files

Abstract Saved from Date Saved File Size Type Download
Most solder mask shifting for the BGA and CSP substrate can be as much as 50 um. For small pad size, a equipment and test engineers. The handler must be able to use a variety of contactor technologies. Johnstech With the increase demand in CSP volume ramp and the package variations, a new manufacturing strategy and TSSOP is typically done using a matrix frame. The test for TQFP and TSSOP is typically done in a pads for plating. The FBGA and CSP (Figure 1) are typically sawn in to individual unit for test. A new
/datasheets/files/national/htm/nsc02558.htm
National 28/06/2001 35.35 Kb HTM nsc02558.htm
CM Series CM 50/125 - Primary Switched-Mode Power Supply Units for Demanding Applications With a regulated and adjustable output voltage of +22,5 to 28.5 V DC, they provide an output current of 2.5 A or 5 A. Capacitive loads and Conventional Technology In linear regulated current supply units, a conventional mains transformer suited for the power supply for electro-mechanical I/O devices such as contactor and relay circuits or
/datasheets/files/phoenix-contact/linien/ide060706.html
Phoenix Contact 25/07/2002 2.26 Kb HTML ide060706.html
: Flash Memory Components Fast Flash Programmer - Handler 12/23/97 3:50:11 PM Vendor FPGAs. Component leads are touched only once by the system with the programmer pin contactor. This one second. Components are centered using a patented laser illuminated camera mounted to the incorporates a laser marking system to help reduce component handling to a minimum. The vision centering and microcontrollers Programs and marks in a single operation File Attachments
/datasheets/files/intel/design/flcomp/devtools/4e6da_1a.htm
Intel 13/05/1998 5.56 Kb HTM 4e6da_1a.htm
: Flash Memory Components First Generation Bulk Erase Programmer - Handler 12/23/97 3:50:11 PM contactor. This reduces any possibility of damage during the centering and marking operations, and increases ) accuracy in less than one second. Components are centered using a patented laser illuminated camera mounted leads. The system incorporates a laser marking system to help reduce component handling to a minimum. The , FPGAs, CPLDs, and microcontrollers Programs and marks in a single operation File
/datasheets/files/intel/design/flcomp/devtools/49e021a6.htm
Intel 05/02/1998 5.86 Kb HTM 49e021a6.htm
interface functions to be implemented to link electronic control and conventional contactor control. The switchgear. The enclosed EM-MPG 45 mounting plate, which resembles a housing, is used to snap on size 0 , trapezoidal SISM 45 mounting plate, shaped like a mounting rail, is used to snap on size 0 switchgear. fitted inside the mounting plate. The SISM 45-H version can be supplied with a taller mounting plate offers a larger mounting area. It is also ideal for transformer constructions with loads up
/datasheets/files/phoenix-contact/linien/ide10119.html
Phoenix Contact 22/07/2002 2.91 Kb HTML ide10119.html
: Flash Memory Components Intel(R) StrataFlash(TM) Memory Programmer - Handler 12/23/97 3:50:11 PM contactor. This reduces any possibility of damage during the centering and marking operations, and increases ) accuracy in less than one second. Components are centered using a patented laser illuminated camera mounted leads. The system incorporates a laser marking system to help reduce component handling to a minimum. The , FPGAs, CPLDs, and microcontrollers Programs and marks in a single operation File
/datasheets/files/intel/design/flcomp/devtools/4e6f6_1a.htm
Intel 13/05/1998 5.57 Kb HTM 4e6f6_1a.htm
: Flash Memory Components FlashFile(TM) Memory Programmer - Handler 12/23/97 3:50:11 PM Vendor FPGAs. Component leads are touched only once by the system with the programmer pin contactor. This one second. Components are centered using a patented laser illuminated camera mounted to the incorporates a laser marking system to help reduce component handling to a minimum. The vision centering and microcontrollers Programs and marks in a single operation File Attachments
/datasheets/files/intel/design/flcomp/devtools/4e6de_1a.htm
Intel 13/05/1998 5.73 Kb HTM 4e6de_1a.htm
: Flash Memory Components Bulk Erase Programmer - Handler 12/23/97 3:50:11 PM Vendor FPGAs. Component leads are touched only once by the system with the programmer pin contactor. This one second. Components are centered using a patented laser illuminated camera mounted to the incorporates a laser marking system to help reduce component handling to a minimum. The vision centering and microcontrollers Programs and marks in a single operation File Attachments
/datasheets/files/intel/design/flcomp/devtools/4e6d6_1a.htm
Intel 13/05/1998 5.69 Kb HTM 4e6d6_1a.htm
: Flash Memory Components High Integration Boot Block Programmer - Handler 12/23/97 3:50:11 PM contactor. This reduces any possibility of damage during the centering and marking operations, and increases ) accuracy in less than one second. Components are centered using a patented laser illuminated camera mounted leads. The system incorporates a laser marking system to help reduce component handling to a minimum. The , FPGAs, CPLDs, and microcontrollers Programs and marks in a single operation File
/datasheets/files/intel/design/flcomp/devtools/49e061a6.htm
Intel 05/02/1998 7.11 Kb HTM 49e061a6.htm
: Flash Memory Components High Value FlashFile(TM) Memory Programmer - Handler 12/23/97 3:50:11 PM contactor. This reduces any possibility of damage during the centering and marking operations, and increases ) accuracy in less than one second. Components are centered using a patented laser illuminated camera mounted leads. The system incorporates a laser marking system to help reduce component handling to a minimum. The , FPGAs, CPLDs, and microcontrollers Programs and marks in a single operation File
/datasheets/files/intel/design/flcomp/devtools/49e0e1a6.htm
Intel 05/02/1998 6.91 Kb HTM 49e0e1a6.htm