500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Top Results

Part Manufacturer Description Datasheet BUY
P31E42DHO107 TE Connectivity / Potter and Brumfield CONTACTORS visit Digikey Buy
P40P44A13P1-240 TE Connectivity / Potter and Brumfield CONTACTORS visit Digikey Buy
5-1393132-1 TE Connectivity / Potter and Brumfield CONTACTORS visit Digikey Buy
1423257-7 TE Connectivity / Potter and Brumfield CONTACTORS visit Digikey Buy
7-1393132-8 TE Connectivity / Potter and Brumfield CONTACTORS visit Digikey Buy
P30P42D12P1-12 TE Connectivity / Potter and Brumfield CONTACTORS visit Digikey Buy

contactor+50+A

Catalog Datasheet MFG & Type PDF Document Tags

1503VC-BMC4

Abstract: contactor wiring diagram with timer momentary open/close commands must be at least 50 milliseconds in duration. Refer to Figure 3.10 for a , Identifies information about practices or circumstances that can cause an explosion in a hazardous , death, property damage, or economic loss. Attentions help you identify a hazard, avoid a hazard, and , dangerous temperatures. IntelliVAC is a trademark of Rockwell Automation, Inc. Table of Contents , Electrical Ratings (Table 1.A) . 1-5 Mechanical Ratings (Table 1
Rockwell Automation
Original

VDE 0660 iec 158-1

Abstract: IEC 158-1 VDE 0660 ) < 40oC A 25 25 32 45 50 50 60 Rated making capacity Irms conforming to IEC-947-4 A 250 250 300 450 550 550 800 Rated breaking capacity Irms conforming to , 32 45 50 50 60 Rated making capacity Irms conforming to IEC-947-4 A 250 , 24 100 200 48 100 400 110 50 600 220 45 600 440 25 A 5 Connection to , 25-400 25-400 25-400 25-400 25-400 V Frequency limits 12 A Rated opeating
-
Original
NFC63-110 VDE0660 JEM1038 IEC60947-4 VDE 0660 iec 158-1 IEC 158-1 VDE 0660 NFC-63110 32A 4 pole relay 230v ac BS5424

wiring diagram contactor

Abstract: wiring diagram to hold contactor with NO, NC ATTENTION Identifies information about practices or circumstances that can cause an explosion in a , damage, or economic loss. Attentions help you: · identify a hazard · avoid a hazard · recognize the , alert people that surfaces may be at a dangerous temperature. Table of Contents Product , 400 A Medium Voltage Contactor User Manual Maintenance Chapter 4 Tool Requirements , . 4-20 Troubleshooting Chapter 5 Troubleshooting · Table 5.A
Rockwell Automation
Original
800T-XD2 1502-UM050C-EN-P wiring diagram contactor wiring diagram to hold contactor with NO, NC Allen-Bradley bulletin 1502 mitsubishi contactor JHP-70A contactor M-5605

GNR20DMZ

Abstract: Relay c 45-45 45-45 45-45 25-25 25-25 25-25 25-25 (1) A new 45 mm ­ 50 A version will be available at , I(A) 5 20 15 10 5 0 0 10 20 30 40 50 60 70 80 t (°C) 0 , 60 70 80 t (°C) GNR20A I(A) 25 20 15 10 5 0 0 10 20 30 40 50 , 20 30 40 50 60 70 80 t (°C) GNR30A I(A) 35 30 25 20 15 10 5 0 18 , 35,6 Curves GNR35B - GNR35D GNR35A I(A) GNR45B - GNR45D I(A) I(A) 50 40 40
Crouzet
Original
GNR20DMZ Relay c 84130103 84130116 ac motors crouzet 82 432 GNR10DCZ UL-94V0 73/23/EEC GNR25B GNR25D GNR25A

siemens contactor 3rt10

Abstract: 3RB20 SIEMENS complete units, 3 . 75 kW Overview A dead interval of 50 ms on reversing is already integrated in , assemblies for wye-delta starting are designed for standard applications. There is also a range of , at AC 50 Hz 400 V Rating kW For overload relays for motor protection, see "Protection Equipment , K3 delta contactor. A solid-state time-delay auxiliary switch block is snapped onto the front of the complete contactor assemblies, size S00 up to 7.5 kW, while a timing relay is mounted onto the
-
Original
3RA13 3RA14 3RT19 siemens contactor 3rt10 3RB20 SIEMENS siemens trip relay 241 siemens star delta contactor Siemens 3RT10 3RA19 13-2B 16-4BA31

1503VC-BMC5

Abstract: wiring diagram contactor A wide range of supply voltage (110 ­ 240 V AC 50/60 Hz, 110 - 250 V DC) allows implementation in , applications must be set for 50 millisecond drop-out time. Refer to Appendix A for typical drop-out time , Identifies information about practices or circumstances that can cause an explosion in a hazardous , death, property damage, or economic loss. Attentions help you identify a hazard, avoid a hazard, and , dangerous temperatures. IntelliVAC is a trademark of Rockwell Automation, Inc. Table of Contents
Rockwell Automation
Original
1503VC 1503-UM053A-EN-P 1503VC-BMC5 INTELLIVAC contactor wiring diagram with timer EH 80 contactor Allen-Bradley bulletin 1500 1503VC-BMC4

Allen-Bradley bulletin 1500

Abstract: contactor wiring diagram with timer Features A wide range of supply voltage (110 ­ 240 V AC 50/60 Hz, 110 - 250 V DC) allows implementation , contactors in MV SMC applications must be set for 50 millisecond drop-out time. Refer to Appendix A for , cause an explosion in a hazardous environment, which may lead to personal injury or death, property , you identify a hazard, avoid a hazard, and recognize the consequences. SHOCK HAZARD Labels may , motor) to alert people that surfaces may be dangerous temperatures. IntelliVAC is a trademark of
Allen-Bradley
Original
1503-UM051C-EN-P 1502-UM052A-EN-P 80174-902-14-R 1503VC-BMC3 80158-779-51-R BMC2 2X18R 2X24R 1503-UM051B-EN-P

3RH1921

Abstract: 3RH1911-1FA22 . with EN 50 012 or EN 50 005) 1-pole auxiliary switch block (a maximum of 4 can be snapped on , in acc. with DIN EN 50 005 contactor arrangements with a 4-pole auxiliary switch block, terminal , occur. They are cut off at approximately 400 V and have a shorter overall duration (approximately 50 us , . with EN 50 012 or EN 50 005) 11 2-pole auxiliary switch block, standard or electronic type 12 , switch block, infeed from below 4-pole auxiliary switch block (terminal markings in acc. with EN 50 011
-
Original
3RH1921 3RH1911-1FA22 3RA1954-2A 3RH1911-1GA22 3RT1926 3rh1921-1 NSB00448 3RB10 3RT1966-4EA3 3RT19664EA1 3RT1956-4EA2 3TX7500-0A

CA3-9-10

Abstract: Sprecher Schuh ca3 -30-110/240 112 110â'¦240V 50/60Hz 110â'¦250V DC Electronic Timing Module â'" âž' ON-Delay The , DC 0.1â'¦3s 1â'¦30s 10â'¦180s 110â'¦240V 50/60Hz CA7 all Electronic Timing Module â'" â , . 0.3â'¦3s 1â'¦30s 10â'¦180s 24V AC 50/60Hz CA7-9â'¦ CA7-37 CA7 all â'¢ Continuous adjustment , ) connector included (9mm) CM7 110â'¦240V 50/60Hz CA7 all ➠21 21 22 22 Mechanical , / AC3 / AC4) Ie [A] ➠kW (50 Hz) Series CA1U Obsolete UL/CSA HP (60 Hz) 1Ø 3Ø 400V
Sprecher + Schuh
Original
CA3-9-10 CA3-12-10 CA3-16-10 Sprecher Schuh ca3 Sprecher Schuh ca3-23-10 Sprecher Schuh CA3-12-10 TE404 CS7-PVB-02 CA7-PV-02 CA7-PVB-02 CS7-PV-11 CS7-PVB-11 CA7-30

telemecanique LR2-D13

Abstract: LR2-D13 control gear The RS `d2' range is a broad and versatile range of motor control gear for the many and varied control applications demanded in a world of increasing automation complexity and improvements in , , 45kW in a range of frame sizes and control voltages, including dc q Thermal overload relays, for full , mounted freestanding overload adaptor q Control relays with a range of contact configurations and control coil voltages, including dc q Front and side mounting instantaneous auxiliary control blocks in a range
RS Components
Original
telemecanique LR2-D13 LR2-D13 VDE 0660 - 107 LR2-D13 Telemecanique telemecanique lr2d13 overload contactor LR2-D13

IEC 947-5-1 VDE 0660

Abstract: relay contactor wiring diagrams 22: 2 NO 2 NC 31: 3 NO 1NC 40: 4 NO 0NC Coil voltage ( AC operated ) 24: AC24V 50/60Hz 48 , Motor Contactor Relays 73KN-##-## 1 2 3 1) 2) 3) Auxiliary Contact Modules A: for mini , A Type Pack 400V A Thermal Rated Current Ith A 24 230 2 10 J7KNA-AR-40 24 Coil voltage 1) 24V 50/60Hz 220-230V 50Hz Weight pcs. kg/pc. 10 0,16 10 , NC Distinc. Number acc. to DIN EN 50011 Ratings AC15 230V A Type Pack Weight
-
Original
AC48V AC240V AC440V IEC 947-5-1 VDE 0660 relay contactor wiring diagrams J73KN-A-40 J73KN-A-22 contactor coils 415v J73KN-A-11 50/60H AC110-115V AC120-125V AC220-230V

IEC 947-5-1 VDE 0660

Abstract: wiring diagram contactor ) 24: AC24V 50/60Hz 48: AC48-50V 50Hz,AC48V 60Hz 90: AC100V 50/60Hz 110: AC110-115V 50Hz,AC120-125V 60Hz 180: AC200V 50/60Hz 230: AC220-230V 50Hz,AC240V 60Hz 240: AC230V-240V 50Hz 400: AC380 , Modules for Mini Motor Contactor Relays J73KN-##-## 1 2 3 1) 2) 3) Auxiliary Contact Modules A , Operated Contacts NO O NC Distinc. Number acc. to DIN EN 50011 Ratings AC15 230V A Type Pack 400V A Thermal Rated Current Ith A 24 230 2 10 J7KNA-AR-40 24
-
Original
contactor coils 24v contactor coils 230v DC contactor 220V J7KNA-09-10-24 contactor 4pole J7KNA-AR-31 AC380-400V AC400-415V AC525-550V AC600V DC125V DC24V

magnetic Contactor wiring diagrams

Abstract: wiring diagram contactor MDRs. Crydom, a world class supplier of Solid State Relays and Controls, has introduced the 3RHP , a unique approach resulting in a Hybrid Solid State Contactor with ratings of up to 50Amps @ 600VAC. The following sections include a comprehensive description of the 3RHP operation, ratings , . Figure 2 shows a simplified comparison of key attributes for each type of switching technology where 100 , Figure 2 - Attributes of commercially available AC switching technologies. A quick review of Figure 2
Crydom
Original
magnetic Contactor wiring diagrams wiring diagram Magnetic contactor contactor 3 phase Wiring Diagram Solid State Switches normally closed contactors 50a wiring diagram auxiliary contactor
Abstract: , diagnostics, and re- Specifications General Specifications Nominal Current @ 45°C: 16, 25, or 50 A , ) 25 A Dimensions: 115 H x 54 W x 92.5 mm D (4.5 x 2.1 x 3.6") 25 A Weight: 500 g (1.1 lb) 50 A Dimensions: 115 H x 107 W x 92.5 mm D (4.5 x 4.2 x 3.6") 50 A Weight: 1.10 kg (2.42 lb) Compatible , , and 50 Amp Current Ratings ß PDLINK is Compatible with CN2100, CN2200 and CN2400 Series Controllers The SSC-TE10S is a solid state contactor for industrial applications such as resistive or Omega Engineering
Original
SSC-TE10S-16A/240-PDL1 CN2204 SSC-FU1038-16A SSC-FU1038-25A SSC-FU2258-50A SSC-FUSE-16A

relay contactor wiring diagrams

Abstract: J7KNA-AR-40 31: 3 NO 1NC 40: 4 NO 0NC Coil voltage (AC operated) 24: AC24V 50/60Hz 48: AC48V 50Hz 110 , Motor Contactor Relays J73KN-##-##-# 1 2 3 4 1) 2) 3) Auxiliary Contact Modules A: for mini , A Type 400V A Thermal Rated Current Ith A 24 230 2 10 J7KNA-AR-40 24 Pack Coil voltage 1) 24V 50/60Hz 220-230V 50Hz Weight pcs. kg/pc. 10 0,16 10 0 , NC Distinc. Number acc. to DIN EN 50011 Ratings AC15 230V A Type Pack Weight
OMRON
Original
marking 62Y zener diode J7KNA-AR-22 J73KN-A-02 AC230-240V DC48V DC60V DC110V 110VS 125VS

crouzet relay

Abstract: EN 60947-4-3 ) GNR30A I(A) 35 30 25 20 15 10 5 0 18 0 10 20 30 40 50 60 70 80 , GNR35A I(A) GNR45B - GNR45D I(A) I(A) 50 40 40 35 35 30 30 35 25 , 10 20 30 40 50 60 70 80 t (°C) GNR45A I(A) 50 45 40 35 30 25 20 , ) (A2s) (50 - 60 Hz) HP ratings at 480 V Static (off-state) dv/dt (V/us) Utilization category AC 51 (A , numbers Type 22.5 mm Current (A) 20 20 20 20 20 20 20 20 30 30 30 30 30 30 30 30
Crouzet
Original
GNR20DHZ crouzet relay EN 60947-4-3 GNR20D GNR25DCZ UL508 GNR20DCZ GNR20DHR GNR20DCR GNR20BHZ

catalog for 3RT series contactor* siemens

Abstract: 3RB2283-4AA1 personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property , taken. CAUTION with a safety alert symbol, indicates that minor personal injury can result if proper precautions are not taken. CAUTION without a safety alert symbol, indicates that property damage can result , present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage
Siemens
Original
catalog for 3RT series contactor* siemens 3RB2283-4AA1 3RT20 siemens star delta starter 3RV21 catalog for 3RT Power contactor* siemens A8E56203880102-02 3ZX1012-0RA21-1AC0

3th4293

Abstract: siemens 3th42 coil circuit (e.g. A = AC standard / without) Rated control supply voltage (e.g. P0 = 230 V, 50 Hz , S00 Control circuit Solenoid coil operating range â'¢ AC operation At 50 Hz At 60 Hz 0.8 . 1.1 x Us 0.85 . 1.1 x Us â'¢ DC operation At 50 °C At +60 °C 0.8 . 1.1 x Us 0.85 , operating range at 50 Hz: 0.8 to 1.1 x Us at 60 Hz: 0.85 to 1.1 x Us. 5/10 Siemens IC 10 · 2014 , ) Coil operating range at 50/60 Hz: 0.85 to 1.1 x Us at 60 Hz: 0.8 to 1.1 x Us. â  Accessories The
Siemens
Original
3RH21 3th4293 siemens 3th42 siemens IEC 60947-5-1 contactor siemens 3th43 3TH43 3TH42 3RH24 3RS18 3TG10 3RH11 PTMT0730

IEC/EN60947-4-1

Abstract: contactor coils 220v 12 = 12 - 32A 18 = 18 - 32A 25 = 25 - 32 A 32 = 32A 40 = 40 - 80A 50 = 50 - 80A 65 = 65 - 80A , , HVAC equipment, elevators and other systems. rail (35mm or 75mm) or mount directly to a panel with screws Efficient 50/60 Hz. coils (50 or 60 Hz coils optional) MECHANICAL 9A and 12A models measure , for UL evaluation. CE marked relay can be added to create a starter ELECTRICAL Coil , Typical Part Number > PBC - 009 A 1 - B7 Series: PBC = IEC Contactors with Integral Auxiliary
Tyco Electronics
Original
IEC/EN60947-4-1 contactor coils 220v timer contactor 380Vac a1218 A1725 PBA-31A PBA-13A PBA-40A PBA-04A PBA-11B PBA-20B

ETR4-70-A

Abstract: EMR4-F500-2 voltage 50/60 HZ: 115/230 V AC · Rated output voltage: 24 V DC · Rated output current: 1.25 A Type , (230V50HZ) 043814 1 off Coil terminal markings to EN 50 005 Other actuating voltages a Page 04/030 , . current Ith 220V 230V 240V 380V 400V 440V A A 6 346 ­ 440 V, 50/60 Hz Type , ) Terminal markings to EN 50 042 Terminal markings to EN 50 042 Std. pack A 3 ETR4 , 380 V 230 V 400 V 240 V 440 V Conv. therm. current Ith A 24 ­ 240 V, 50/60 Hz, AC 24
-
Original
TPE11DIL TPD11DIL ESR3-NO-31 EMR4-F500-2 EMR4-W500-2-C EMR4-W500-2-D ETR4-70-A ETR4-69-A moeller ets4-vs3 HPL0211-2001/2002 DILET11 DILET70 11DIL DILR22
Showing first 20 results.