NEW DATABASE - 350 MILLION DATASHEETS FROM 8500 MANUFACTURERS

Datasheet Archive - Datasheet Search Engine

 

Direct from the Manufacturer

Part Manufacturer Description PDF Samples Ordering
PMP2916 Texas Instruments Sync Buck for Metro Ethernet 3.3V@50A ri Buy
TPS51727RHATG4 Texas Instruments Dual-Phase, D-CAP+? Mode Step Down Power Management IC for 50A+ Applications 40-VQFN -10 to 100 ri Buy
TPS51727RHAR Texas Instruments Dual-Phase, D-CAP+? Mode Step Down Power Management IC for 50A+ Applications 40-VQFN -10 to 100 ri BuyFREE Buy

contactor 50 A

Catalog Datasheet Results Type PDF Document Tags
Abstract: Braking Devices VersiBrake 36A 3.9 Features: A A A A A A A A DC braking with , Devices VB 230-36 VB 400-36 Function: A A A A A A A A Typical Applications: control via motor contactor standstill detection braking current limited to rated device current remanence time optimization braking current infinitely adjustable potential-free output for motor contactor interlocking , contactor sawing machines centrifuges wood working machines textile machines conveying systems L1 ... Original
datasheet

2 pages,
164.85 Kb

400-36 75kW braking contactor connection DC MOTOR 24v delta motor power control circuit 220vdc signalling relay star delta connection circuit diagrams contactor 400 A star-delta starting motors 75kw dc motor contactor 100 A datasheet abstract
datasheet frame
Abstract: Crydom Hybrid Solid State Contactor Introduction 1 What is a "Hybrid Solid State Contactor"? A power relay configured as a 3 phase contactor which combines both solid state and , dissipation in the EM contacts. Traditional DP contactor mounting and wire termination. 3 Where would a , Contactor Enviro SSR Thermal Cost Hybrid Solid State Contactor This is a comparison of some , the solid state and electromechanical technologies? Combining the 2 technologies creates a ... Original
datasheet

14 pages,
774.44 Kb

contactor 3 phase ac ssr contactor 100 A 1 phase contactor contactor connection food heat lamps GENERAL ELECTRIC ac contactor contactor 3 phase power contactor General Electric Solid State datasheet abstract
datasheet frame
Abstract: operational current AC-3 380 V 400 V Ie A 45 AC-3 220 V 230 V P kW 11 AC-3 380 V 400 , rating for three-phase motors, 50 ­ 60 Hz Max. changeover time s Actuating voltage < 20 230V 50Hz, 240V 60Hz Individual components of the combination Mains contactor Q11 DILM25-10 DILM25-10 + DILA-XHI20 DILA-XHI20 Delta contactor Q15 Part no. DILM25-01 DILM25-01 + DILA-XHI20 DILA-XHI20 Star contactor Q13 Part no. , fuse protection and the input wiring for the mains contactor and delta contactor are to be common or ... Original
datasheet

3 pages,
830.02 Kb

C2007G DILA-XHI20 DILM25 230v,50Hz wiring diagram auxiliary contactor DILM25-01 etr4 DILM17-01 ETR4-51 230V50HZ contactor 2 KW contactor overload contactor SDAINLM45 SDAINLM45 230V50HZ SDAINLM45 abstract
datasheet frame
Abstract: 50 / 60 Hz 11 VA Input Control Day/night contactor Output of the contactor is closed when the , electromechanical relays with those of a solid-state relay. The result is a compact relay capable of 5M+ operations , Series Hybrid Solid State Relays Current 20 A 20 A 20 A 20 A Output voltage 90-260 V AC 90-260 , crossing Bistable Day/Night Contactor Part number 84138000 84138001 84138101 84138201 Hybrid , advantage without the drawbacks Lifetime > 5 million operations full load Noiseless Functions: contactor ... Original
datasheet

2 pages,
90.88 Kb

EN 60947-4-3 AC51 BISTABLE RELAY datasheet abstract
datasheet frame
Abstract: Frequency Max. power consumption 90-260 Vac 50 / 60 Hz 11 VA Input Control Day/night contactor , electromechanical relays with those of a solid-state relay. The result is a compact relay capable of 5M+ operations , Series Hybrid Solid State Relays Current 20 A 20 A 20 A 20 A Output voltage 90-260 V AC 90-260 , crossing Bistable Day/Night Contactor Part number 84138000 84138001 84138101 84138201 Check , operations full load Noiseless Functions: contactor ­ bistable 17.5 mm DIN rail mount UL/c UL (listed ... Original
datasheet

2 pages,
91.1 Kb

EN 60947-4-3 bistable relay AC51 datasheet abstract
datasheet frame
Abstract: 3RA13 3RA13, 3RA14 3RA14 Contactor Assemblies 3RA14 3RA14 Contactor Assemblies for Wye-Delta Starting 3RA14 3RA14 complete units, 3 . 75 kW Overview A dead interval of 50 ms on reversing is already integrated in the time relay function. Note: Contactor assemblies for wye-delta starting in special , K3 delta contactor. A solid-state time-delay auxiliary switch block is snapped onto the front of the complete contactor assemblies, size S00 up to 7.5 kW, while a timing relay is mounted onto the ... Original
datasheet

2 pages,
113.46 Kb

46-4JB0 3RB20 26-1QB0 wye-delta 3RT10 siemens 3rb20 3RT10 65 star delta connection 3RT10 SIEMENS Installation 3RT10 SIEMENS 3RB29 siemens contactor siemens trip relay 241 Siemens 3RT10 siemens relays 3RU11 S00-S00-S00 3RT10 S00-S00-S00 abstract
datasheet frame
Abstract: connection to the contactor coil terminals LCtD40 to D115 (3P or 4P) Operating voltage 50/60 Hz and , TeSysTM D-Line Contactor Accessories Coil Suppressors, Cabling Accessories www.SquareD.com For , in AC contactor coils Effective protection of circuits sensitive to high frequency interference. · , (4P), Snap-on mounting and connection without tools to the contactor coil terminals Screw connection to the contactor coil terminals LCtD12 and D25 (4P) Pre-TeSys Contactors LCtD40 to D150 ... Original
datasheet

1 pages,
80.23 Kb

LA4-DE LC1D09 line contactor contactor schneider catalog lad4rcg Schneider LC1DT20 LC1DT20 contactor coils LAD4TB LC1D09 CONTACTOR LA4DC1U Schneider LC1DT20 contactor LC1D09 schneider LAD4RCU RC SUPPRESSOR datasheet abstract
datasheet frame
Abstract: data sheet TEST CONTACTOR FusionQuad® Test Contactor Test Hardware List: Amkor FusionQuad® Test Contactor: Amkor Technology is now offering the FusionQuad® Test Contactor Amkor's FusionQuad® represents a breakthrough in leadframe-based plastic packaging through the effective , bottom lands within a standard VQFP package format. The novel integration of bottom lands provides a cost-effective platform for increased lead count in a small form factor. FusionQuad® not only extends the I/O ... Original
datasheet

1 pages,
526.87 Kb

contactor Amkor Technology NS6040 laptop ic list datasheet abstract
datasheet frame
Abstract: Rated operational current AC-3 400 V Ie A 45 Max. rating for three-phase motors, 50 ­ 60 Hz AC-3 230 V P kW 11 Max. rating for three-phase motors, 50 ­ 60 Hz AC-3 400 V P kW 22 Max. rating for three-phase motors, 50 ­ 60 Hz AC-3 500 V P kW 30 Max. rating for three-phase motors, 50 ­ 60 Hz AC-3 690 V P kW 22 Max. changeover time s Actuating voltage < 20 110V 50 Hz, 120V 60 Hz Individual components of the combination Mains contactor K1M Part ... Original
datasheet

3 pages,
818.18 Kb

3 phase motor delta star SDAINLM45 DILM17 110V50HZ 120V60HZ DILM25-10 DILA-XHI20 DILM25-01 DILM17-01 ETR4-51 SDAINLM45 abstract
datasheet frame
Abstract: Rated operational current AC-3 400 V Ie A 55 Max. rating for three-phase motors, 50 ­ 60 Hz AC-3 230 V P kW 15 Max. rating for three-phase motors, 50 ­ 60 Hz AC-3 400 V P kW 30 Max. rating for three-phase motors, 50 ­ 60 Hz AC-3 500 V P kW 37 Max. rating for three-phase motors, 50 ­ 60 Hz AC-3 690 V P kW 30 Max. changeover time s Actuating voltage < 20 110V 50 Hz, 120V 60 Hz Individual components of the combination Mains contactor K1M Part ... Original
datasheet

3 pages,
818.2 Kb

OVERLOAD RELAY etr4 DILM32-01 star delta wiring DILM32-10 DILM32 sdainlm55 SDAINLM55 110V50HZ 120V60HZ DILA-XHI20 DILM25-01 ETR4-51 SDAINLM55 abstract
datasheet frame

Datasheet Content (non pdf)

Abstract Saved from Date Saved File Size Type Download
Over 1.1 million files (1986-2014): html articles, reference designs, gerber files, chemical content, spice models, programs, code, pricing, images, circuits, parametric data, RoHS data, cross references, pcns, military data, and more. Please note that due to their age, these files do not always format correctly in modern browsers. Disclaimer.
 
devices such as contactor and relay circuits or solenoid valves. The devices provide a non-regulated rated CM 50/125 - Primary Switched-Mode Power Supply Units for Demanding Applications With a regulated and adjustable output voltage of +22,5 to 28.5 V DC, they provide an output current of 2.5 A or 5 A. Capacitive loads and selective systems are safely managed by regulated current supply units, a conventional mains transformer whose output voltage is rectified and
www.datasheetarchive.com/files/phoenix-contact/linien/ide060706.html
Phoenix Contact 25/07/2002 2.26 Kb HTML ide060706.html
can be as much as 50 um. For small pad size, a 50 um shift can be quite significant pad shift challenging areas for the equipment and test engineers. The handler must be able to use a variety of contactor increase demand in CSP volume ramp and the package variations, a new manufacturing strategy has been using a matrix frame. The test for TQFP and TSSOP is typically done in a singulated format. The TQFP and CSP (Figure 1) are typically sawn in to individual unit for test. A new substrate manufacturing
www.datasheetarchive.com/files/national/htm/nsc02558.htm
National 28/06/2001 35.35 Kb HTM nsc02558.htm
currents in the ranges 0...0.2 A to 0...55 A Active and passive r.m.s. value current transducers for converting sinusoidal alternating currents in the ranges 0...1 A and 0...5 A Contactor for sinusoidal alternating currents up to 16 A Voltage transducer DC voltage evaluated by means of a bipolar output signal. For the 230 V/50 Hz power system, this lamps, heaters etc.) are operated in a conventional 230 V power system, no distortions are produced on
www.datasheetarchive.com/files/phoenix-contact/linien/ide060403.html
Phoenix Contact 22/07/2002 6.37 Kb HTML ide060403.html
conventional contactor control. The following versions are available: The EM-MP 45 N mounting plate for screwing on size 0 switchgear. The enclosed EM-MPG 45 mounting plate, which resembles a housing mounting plate, The enclosed, trapezoidal SISM 45 mounting plate, shaped like a mounting rail, is used can be supplied with a taller interior to accommodate more electronic components. The connecting lines The EM-MP 70 mounting plate offers a larger mounting area. It is also ideal for transformer
www.datasheetarchive.com/files/phoenix-contact/linien/ide10119.html
Phoenix Contact 22/07/2002 2.91 Kb HTML ide10119.html
1. PFC controller 2. Contactor 3. Capacitor 4. Capacitor bank The current of the power converter is composed of a mix of sinusoidal currents, a fundamental component with line frequency and a number of harmonics whose frequencies are integral multiplies of the to a certain harmonic frequency whose harmonic currents can be suppressed by up to 90%. almost their entire capacitor power. Tuned filter circuits cannot be regulated by a VAr controller
www.datasheetarchive.com/files/epcos/htmls/web/produkt_katalog/html/t_info/application_e.html
Epcos 31/08/2001 67.92 Kb HTML application_e.html
1. PFC controller 2. Contactor 3. Capacitor 4. Capacitor bank The current of the power converter is composed of a mix of sinusoidal currents, a fundamental component with line frequency and a number of harmonics whose frequencies are integral multiplies of the to a certain harmonic frequency whose harmonic currents can be suppressed by up to 90%. almost their entire capacitor power. Tuned filter circuits cannot be regulated by a VAr controller
www.datasheetarchive.com/files/epcos/htmls/web/produkt_katalog/html/t_info/print/application_e.html
Epcos 31/08/2001 44.91 Kb HTML application_e.html
Components FlashFile(TM) Memory Programmer - Handler 12/23/97 3:50:11 PM Vendor Information are touched only once by the system with the programmer pin contactor. This reduces any possibility of Components are centered using a patented laser illuminated camera mounted to the pick-and-place head to guarantee each part is placed exactly in the socket without bending its leads. The system incorporates a laser marking system to help reduce component handling to a minimum. The vision centering and
www.datasheetarchive.com/files/intel/design/flcomp/devtools/4e6de_1a.htm
Intel 13/05/1998 5.73 Kb HTM 4e6de_1a.htm
Components Intel(R) StrataFlash(TM) Memory Programmer - Handler 12/23/97 3:50:11 PM Vendor Information are touched only once by the system with the programmer pin contactor. This reduces any possibility of Components are centered using a patented laser illuminated camera mounted to the pick-and-place head to guarantee each part is placed exactly in the socket without bending its leads. The system incorporates a laser marking system to help reduce component handling to a minimum. The vision centering and
www.datasheetarchive.com/files/intel/design/flcomp/devtools/4e6f6_1a.htm
Intel 13/05/1998 5.57 Kb HTM 4e6f6_1a.htm
Components Bulk Erase Programmer - Handler 12/23/97 3:50:11 PM Vendor Information Tool with the programmer pin contactor. This reduces any possibility of damage during the centering and programming sockets with 0.001" (0.025mm) accuracy in less than one second. Components are centered using a exactly in the socket without bending its leads. The system incorporates a laser marking system to help reduce component handling to a minimum. The vision centering and closed-loop positioning systems of the
www.datasheetarchive.com/files/intel/design/flcomp/devtools/4e6d6_1a.htm
Intel 13/05/1998 5.69 Kb HTM 4e6d6_1a.htm
Components First Generation Bulk Erase Programmer - Handler 12/23/97 3:50:11 PM Vendor Information are touched only once by the system with the programmer pin contactor. This reduces any possibility of Components are centered using a patented laser illuminated camera mounted to the pick-and-place head to guarantee each part is placed exactly in the socket without bending its leads. The system incorporates a laser marking system to help reduce component handling to a minimum. The vision centering and
www.datasheetarchive.com/files/intel/design/flcomp/devtools/49e021a6.htm
Intel 05/02/1998 5.86 Kb HTM 49e021a6.htm