500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Top Results

Part Manufacturer Description Datasheet BUY
DMD-DISCOVERY-3000-STARTERKIT Texas Instruments Discovery 3000 Starter kit visit Texas Instruments
DMD-DISCOVERY-1100-STARTERKIT Texas Instruments Discovery 1100 Starter kit visit Texas Instruments
CYCLONEIII-STARTER-REF Texas Instruments Cyclone III Starter Kit visit Texas Instruments
MULTI-CAL-SYSTEM-STARTER-KIT Texas Instruments Multi-Cal-System Basic Starter Kit visit Texas Instruments
ASLK-STARTERKIT Texas Instruments Analog System Lab Starter Kit ASLKv2010 visit Texas Instruments
LDC1000NHRT Texas Instruments 5V, High Resolution, Inductance to Digital Converter for Inductive Sensing Applications 16-WSON -40 to 125 visit Texas Instruments

contactor starter for a single phase capacitor start induction motor

Catalog Datasheet MFG & Type PDF Document Tags

3 phase motor start with contactor

Abstract: single phase capacitor induction motor modules Size 0.55kW 1.1kW 2.2kW For use on the following types of motor: q Capacitor start , to retrofit. Single phase snatch-free soft-start modules provide a compact and simple means of , circuit breaker* or start contactor and overload. Motor circuit breaker* or start contactor and , Motor circuit breaker* or start contactor and overload. K1 1 2 P M L1 Adjustments M , accordance with the wiring regulations must be provided. A circuit breaker, motor starter or additional
RS Components
Original

overload protection of induction motor

Abstract: contactor starter for a single phase capacitor start induction motor . current in C A is 2 A) E N L1 L1 Motor circuit breaker* or start contactor and overload. Motor circuit breaker* or start contactor and overload. K1 K1 1 2 Adjustments M - , capacitor E N Motor circuit breaker* or start contactor and overload. K1 2 PE , start modules Size 2.2kW RS stock number 209-6340 For use on the following types of motor , on line started single phase induction motors. Damage to products, packaging and the maintenance
-
Original

capacitor start induction motor

Abstract: 3 phase motor start with contactor motor: q Capacitor start, capacitor run with centrifugal switch q Permanent capacitor q Capacitor start, capacitor run with internal switching facility. Single phase snatch-free soft-start modules Size 2.2kW RS stock no. 209-6340 General Single phase snatch-free soft-start modules provide a compact and , single phase induction motors. Damage to products, packaging and the maintenance cost and down time of , ) E N L1 Motor circuit breaker* or start contactor and overload. K1 Motor circuit breaker* or
-
Original

capacitor start induction motor

Abstract: contactor starter for a single phase capacitor start induction motor modules Size 2.2kW For use on the following types of motor: q Capacitor start, capacitor run with , shocks of direct on line started single phase induction motors. Damage to products, packaging and the , circuit breaker* or start contactor and overload. Motor circuit breaker* or start contactor and , Motor circuit breaker* or start contactor and overload. K1 1 2 P M L1 Adjustments M , accordance with the wiring regulations must be provided. A circuit breaker, motor starter or additional
RS Components
Original

2.2KW induction motor

Abstract: single phase induction motors modules Size 0.55kW 1.1kW 2.2kW For use on the following types of motor: q Capacitor start , to retrofit. Single phase snatch-free soft-start modules provide a compact and simple means of , circuit breaker* or start contactor and overload. Motor circuit breaker* or start contactor and , Motor circuit breaker* or start contactor and overload. K1 1 2 P M L1 Adjustments M , accordance with the wiring regulations must be provided. A circuit breaker, motor starter or additional
RS Components
Original

autotransformer starter

Abstract: Allen-Bradley MV soft starter voltage drives provide a single solution for all medium voltage speed control requirements. The PowerFlex , interwiring is reduced to a single DeviceNet cable · New 8 ampere, Class 1 DeviceNet cabling · Tested for , methods for a variety of applications. Its unique control options offer enhanced motor starting and , ownership by using a single control infrastructure for the entire range of factory automation applications , Non-Reversing Starter Description of Features 400 A · Fixed mounted vacuum contactor · HIGH and LOW
Allen-Bradley
Original

VARISTOR 385 K14

Abstract: Protection Relay Load Cablesâ'"Moved for Full Voltage Start Main Starter Cubicle Ratings â , 10.1-2. Induction Motor Reduced Voltage Autotransformer Starter, Vacuum Contactor with Optional EMR , version of the SL Contactor is supplied as standard for those applications requiring a 400A contactor , bars connect the contactor line and load terminals to the power components in the starter cell. A , contactor is inserted into the starter cell. The contactor is held in position by a bolt and bracket
EATON
Original

5611A B

Abstract: siemens softstarter wiring diagram 3RW40 field level, ASInterface connects actuators and sensors â'" from temperature sensor to motor starter â , 4-pole, 4 NO, 200 . 1000 A Accessories and Spare Parts For 3RT, 3RH Contactors and Contactor , for 3TC, 3TF, 3TK contactors Controls â'" Contactors and Contactor Assemblies Introduction 2 , . 83 + 3RB29 06 10 . 100 A(Chap. 3) 3RV10 motor starter protectors (protection equipment: motor , select combinations of motor starter protector and contactor as explained in â'Fuseless Load Feedersâ
Siemens
Original
5611A B siemens softstarter wiring diagram 3RW40 3TF6 1KB4 3RP15 05-1AP30 H-1/187

crouzet 88 810.0 Automation Controls

Abstract: pc star ups SERVICE MANUAL pdf and NZM circuit-breakers up to 630 A â'¢ Outgoers for motor starters up to 250 kW â'¢ Empty , for up to 15 removable compartments for power outgoers and motor starters or â'¢ Section for up to , Removable compartments â'¢ Power outgoers up to 630 A âMotor starters up to 90 kW â'¢ Module is for , for power outgoers and motor starters â'¢ High packing density â'¢ Uniform, straightforward , 4b MODAN for withdrawable units â'¢ Power outgoers up to 630 A âMotor starters up to 200 kW
EATON
Original
crouzet 88 810.0 Automation Controls pc star ups SERVICE MANUAL pdf EATON crouzet 88 810.1 crouzet timer top 948 B10D D-53115 PU08703001Z-EN

westinghouse to Cutler-Hammer cross reference

Abstract: WESTINGHOUSE life line contactor speed regulation, this device is known as a starter rather than a controller. Applications for starter , .V12-T13-69 Overview Type N Contactor Citation Starter Product Description Cutler-Hammer , â'" 5 3 Replacement Capabilities Size 1 Contactor 6 Technology Upgrades There are no replacement parts available. Replace with new contactor or starter. 4 5 Size Size , 16 17 Size 5 Contactor Parts are no longer available for Pre-3 Star. 18 19 20 21 22
EATON
Original
westinghouse to Cutler-Hammer cross reference WESTINGHOUSE life line contactor Cutler-Hammer type m RELAY 927566 Cutler-Hammer 9586 westinghouse contactor V12-T13-2 V12-T13-72 V12-T13-76 V12-T13-87 CA08100014E V12-T13-1

wiring diagram for water pump control by VFD

Abstract: vfd circuit diagram for motor rating over the speed range specified in Appendix A: q Standard AC squirrel cage induction motor q Standard AC synchronous motor (DC brush type or AC brushless type) q Standard AC wound rotor induction , protection and isolation of the VFD from the main supply, an input starter (sized for motor current) shall , specified in the attached Appendix A data sheet, a bypass starter shall be provided. The manufacturer for , voltage shall be 208 ­ 575 volt, 3 phase as specified on the attached data sheet (Appendix A).
Allen-Bradley
Original
wiring diagram for water pump control by VFD vfd circuit diagram for motor Spare parts POWERFLEX 7000 PLC based industrial application project with VFD vfd circuit diagram for ac motor using pwm wiring diagram motor start delta with VFD 7000-SR001F D-74834 7000-SR001E-EN-P

relay HM 810

Abstract: H9208 solution for your application demands, offering a complete product lineup of electric motors, adjustable , from ½ to 10,000 HP and 230 to 6,600 V and our low and medium voltage motor controls range from 3 to , #7; A #7; uto-Restart Operation/Catch a Spinning Motor GX7 ââââS15/S11 , EMA 1 Enclosure N â'¢ #7; EC 2005 Motor Overload Retention (No External N Motor Overloads Required , '" 40 HP Style: AA â'" Includes motor circuit protector AE â'" Includes motor circuit protector
Toshiba
Original
relay HM 810 H9208 autotransformer starter medium voltage

westinghouse to Cutler-Hammer cross reference

Abstract: 10000 watt stabilizer transformer winding formula . Note: â  If required, accessories are available on Page A-13. â  The standard IT. starter is for 3-phase , available on Page A-13. â  The standard IT. starter is for 3-phase applications only. â  See Table A , 101 = FVNR Starter 111 = FVNR Contactor 501 = FVR Starter 511 = FVR Contactor Overload Type A = , forward and reverse contactors â'" one control point for wiring NEMA Full Voltage Reversing Contactor , Voltage (Uimp) 6 kV ᕃ á•" ᕠᕠAuxiliaries add approximately 1.0" (25 mm) to depth for single
EATON
Original
10000 watt stabilizer transformer winding formula N05NCXRD3A CN15GN3 N101BS0A3A N101DS2K3A AN16TN0 CA08102002K

1562E

Abstract: ISA-S71 are available within a single controller: · · · · · · · · Soft Start with Selectable , . Vacuum Bypass Contactor A contactor shall be provided to bypass the SCRs once the motor is up to full , /60 Hz. It shall be rectified to provide a DC operating voltage for the vacuum contactor coils and , loop control of a motor to match the specific torque requirements of centrifugal pumps for both , requirements of all types of industries for well over six decades. From the original oil-immersed contactor
Rockwell Automation
Original
1562E ISA-S71 star delta starter single line drawing Allen-Bradley bulletin 1502 contactor starter for a single phase capacitor start induction motor Allen-Bradley MV soft starter 1560E 1560E-SR022C-EN-P 1500-SR020 1500-TD220 1560E-PP001

ATS22C17S6

Abstract: ATS22C59Q IcL. Example: for a 400 V - 110 kW motor with a line current of 195 A, the minimum soft starter rated , starter. A separate contactor should be used to switch the capacitors off when the motor is off, or , 6 Steps for setting up the soft starter (also refer to Quick Start guide , the motor cable. â'¢ Before performing work on the soft starter system: - Disconnect all power , starter setup and motor performance display. The ATS22 is available in 15 rated currents from 17 to 590 A
Schneider Electric
Original
ATS22C17S6 ATS22C59Q schneider star delta timer ATS22C48Q ATS22C11Q ATS22D62Q BBV51330 UL508

SC03Y

Abstract: SC-05 Fuji Standard D Code Contactor SW series magnetic motor starter SC 25 B A A N ­M 22 TB , corrosive atmospheres. See page 01/62. This is a standard type magnetic contactor with a 3-phase , phase sequence protective device *2 Contactor Starter ­ SW-03/2E+QE-0N ­ SW-0/2E+QE-0N ­ , /2E+QE-0N SW-N2/2E+QE-0N Page 01/58 For single-phase resistance load Contactor Starter , /2E Page 01/56 With phase-loss and phase sequence protective device *2 Contactor Starter
-
Original
SC03Y SC-05 Fuji square d starter type sc03 Fuji 3pole 3 phase magnetic Contactor SC-N* "Fuji" SCN5 SC-03 SZ-WN10J SZ-WN11J SW-N10/3H SW-N11/3H

magnetic Contactor wiring diagrams and float switch

Abstract: CL03A starter with start/emergency stop push-button Power circuit Use of two phases (single phase) Three phase , A B C D E F G H I X · Link modules for mechanical and electrical connection of the manual motor starter and the M / CL contactor range · Base plates for Din rail and busbar adapters · Wiring kits for , ! ! ! ! pg. B.8 pg. B.10 pg. B.12 pg. B.14 For fuseless starter application turn the contactor , manual motor starter. Then fit the contactor plastic cover into the contactor front to have the terminal
GE Power Protection
Original
magnetic Contactor wiring diagrams and float switch CL03A FDN36MC080GD star delta FORWARD REVERSE STARTER FDN36MC100GD GPF10C02 0580U 0820U H-1340 B-9000 C/4601/E/EX

MFL1003

Abstract: mccb 60947-2 max zs 40.47 2000 (b) For single phase line-neutral faults, take the cable resistance and double (x2) the resistance to obtain the line-neutral value. 4.75 400 Notes: (a) This applies for 3-phase , CAUSES OF SPASMODIC TRIPPING MODULAR CONTACTORS 26 28 29 30 31 32 world from a single source , should ensure the suitability of the products for installation. To this end it is a requirement for the , CHARACTERISTICS 48 49 50 50 52 52 52 52 53 53 54 55 SELECTING THE CORRECT MOTOR STARTER 60
EATON
Original
MFL1003 mccb 60947-2 max zs memshield 2 project on dol starter wiring bs88 zs levels

SZ-Z5

Abstract: SC-05 Fuji for the new Thermal Overload Relays P ï¼'ï¼ urchasing magnetic â'Œ #7; contactor and Thermal Overload Relay separately and combining them as a magnetic motor starter Magnetic Contactor Thermal , pushbuttons, hence best suited for direct-on-line starting. â'¢ Superior motor protection â'" Built-in highly , range (See the next page.) Types and ratings Max. motor capacity (kW) Single- 3-phase phase 110V , 4 5.5 7.5 7.5 7.5 Rated operational current (A) Single- 3-phase phase 110V 200V 380V
Fuji Electric
Original
SZ-Z5 AR15C DR15C AF15C DF15C AR16C DR16C

blown fuse indicator project report

Abstract: ELECTRONIC circuit diagram of digital hearing aid motor controller spare parts listing and pricing 6. Include name and phone number for a local , 800 A The contactor shall have visual contact wear indicators. No special tools are required for , once the motor is up to full speed. When a stop option is selected, the bypass contactor will open , . [Optional: The bypass contactor shall be capable of providing a full voltage start in case of emergency , experience in the manufacturer of medium voltage smart motor controllers (SMCs) for use in similar
-
Original
blown fuse indicator project report ELECTRONIC circuit diagram of digital hearing aid project report on traffic light controller automatic water pump control project smart Hearing Aid Circuit Diagram 3 phase motor soft starter with two SCR 1560EW-SR001C-EN-E
Showing first 20 results.