NEW DATABASE - 350 MILLION DATASHEETS FROM 8500 MANUFACTURERS

Datasheet Archive - Datasheet Search Engine

 

Catalog Search Results

Catalog Datasheet Results Type PDF Document Tags
Abstract: ExStik® Waterproof Chlorine Meter Direct reading of Total Chlorine down to 0.01ppm Unaffected by color/turbidity of the sample Features: · Direct reading of Total Chlorine provides fast and easy , electronic calibration · Memory stores, tags and recalls up to 15 readings · Unique flat surface chlorine , Chlorine and Temperature plus analog bargraph indicator · Complete with meter and flat surface Chlorine , batteries, and 48" (1.2m) neckstrap Testing Chlorine level in public reservoir ExTabTM Chlorine ... Original
datasheet

1 pages,
235.61 Kb

datasheet abstract
datasheet frame
Abstract: Data Sheet SS/AW400 SS/AW400 Issue 3 Residual Chlorine Monitor AW400 AW400 Total and Free Residual Chlorine Measurement ­ add potassium iodide to reagent to convert free chlorine measurement to total chlorine Reagentless Operation ­ reduced operating costs with reagentless operation at a pH of 7.5 or , ­ instant response to changes of residual chlorine, unlike batch/DPD methods Pressure Regulated , For the measurement of Free and Total Residual Chlorine, Chlorine Dioxide or Ozone in water ... Original
datasheet

8 pages,
425.13 Kb

automatic WATER pressure pump CONTROL bottle feeder chlorine chlorine dioxide PT100 ABB datasheet PT100 level sensor water ph sensor water level control applications free water ph level sensor water pH measurement sensor sensor swimming pools chlorine feed pump SS/AW400 AW400 SS/AW400 abstract
datasheet frame
Abstract: oxygen, ozone, chlorine, temperature, conductivity and redox potential, suiting a wide range of , the case of chlorine, both the total chlorine concentration and the free chlorine concentration are measured. The free chlorine concentration includes chlorine that exists in solution as Cl2 and OCl-, whilst the total chlorine concentration also includes chlorine that has formed complexes, such as , Concentration The measurement of dissolved oxygen, chlorine and ozone concentrations employs a ... Original
datasheet

2 pages,
118.77 Kb

Oxygen sensor module LA12 GAS SENSOR for oxygen water flow sensor electrochemical gas sensors datasheet dissolved dissolved oxygen sensor ph sensor datasheet abstract
datasheet frame
Abstract: LGS09 LGS09 Chlorine Sensor SPECIFICATION 3x3 mm Standard Power LGS09 LGS09 Heater Resistance at 21°C , Chlorine Typical Value 195 K Sensor Resistance in 3ppm Chlorine Fast response · Improved Range & , Sensor Resistance in 5ppm Chlorine Typical Value 415 K Typical sensor measurement voltage Typical , accelerated thermal ageing at 480°C for 1 year. See MIL-STD-883D MIL-STD-883D Capteur's `LG' series chlorine sensors , Selector. LGS09 LGS09 Chlorine Sensor 5ppm Resistance / K Figure 3ppm 1.5ppm 400 300 ... Original
datasheet

2 pages,
47.55 Kb

LGS09 GAS SENSOR for ozone electrochemical gas sensors datasheet carbon monoxide sensor electrochemical carbon dioxide sensor 2SJ182L Capteur Sensors electrochemical gas sensors LGS09 abstract
datasheet frame
Abstract: ) 6002 Chlorine, hydrogen chloride, and sulfur dioxide or chlorine dioxide or hydrogen sulfide (escape only) (a)(b) 60922 6003 Certain organic vapors, chlorine, hydrogen chloride, and sulfur dioxide or hydrogen sulfide (escape only) or hydrogen fluoride (a)(b) P100/Chlorine, hydrogen chloride, and sulfur dioxide or chlorine dioxide or hydrogen sulfide (escape only) (a)(b) 60923 P100/Certain organic vapors, chlorine, hydrogen chloride, and sulfur dioxide or hydrogen sulfide ... Original
datasheet

4 pages,
132.23 Kb

SA-2500 3M 6000 6889 3M belt chloride ups FT-10 P100 Relief Valve DATA SHEET SA-1500 11J6200 Cartridge Filter sa 732 6895 3M datasheet abstract
datasheet frame
Abstract: 6001 6002 Certain organic vapors (a)(b) Chlorine, hydrogen chloride, and sulfur dioxide or chlorine dioxide or hydrogen sulfide (escape only) (a)(b) Certain organic vapors, chlorine, hydrogen chloride, and , )(b) Formaldehyde and certain organic vapors (a)(b)(c) Certain organic vapors, chlorine, hydrogen chloride, chlorine dioxide, sulfur dioxide, hydrogen sulfide (escape only) ammonia/methylamine, formaldehyde or hydrogen fluoride (a)(b)(c) Mercury vapor or chlorine gas (a)(b) 60921 60922 P100/Certain ... Original
datasheet

4 pages,
316.29 Kb

datasheet abstract
datasheet frame
Abstract: ), chlorine (CL), and antimony (Sb303) are not intentionally added during the manufacturing process. A Green , less than 900ppm of chlorine and bromine, known as halogens, and avoids the use of brominated flame ... Original
datasheet

1 pages,
63.9 Kb

SB203 marking 222 HV9910NG HV9910NG abstract
datasheet frame
Abstract: ITS-P-10002FH ITS-P-10002FH FH52 Series 0.5 mm Pitch, 2 mm Height, Robust FPC/FFC Connector Features 1. Increased FPC/FFC retention force with tabs 2. Robust lock structure with unique contact design 3. Board area under the connector is available for PCB patterning 4. Board placement with automatic equipment 5. RoHS compliant, Halogen-free product* *This product satisfies halogen free requirements defined as 900 ppm maximum chlorine, 900 ppm maximum bromine, and 1500 ppm maximum total of chlorine and bromine. ... Original
datasheet

1 pages,
350.37 Kb

ITS-P-10002FH ITS-P-10002FH abstract
datasheet frame
Abstract: RECOMMENDED SOLDERING CONDITIONS OF WAVE SOLDERING (WS60-00-1 WS60-00-1) The following is recommended soldering conditions of wave soldering Maximum temperature (Solder temperature) Time at maximum temperature Preheating temperature (Package's surface temperature) Maximum number of flow processes Maximum chlorine content of rosin flux : 260 or below : 10s or less : 120 or below : 1 time : 0.2 % (wt.) or less WS60-00-1SSD-A-M0034-4 WS60-00-1SSD-A-M0034-4 ... Original
datasheet

1 pages,
4.51 Kb

Chlorine WS60001 WS60001SSDAM00344 WS60001 abstract
datasheet frame
Abstract: removing the residual flux with freon-based and chlorine-based cleaning solvent. 2. Cautions regarding , 30 s · Number of reflows Three · Flux Rosin flux containing small amount of chlorine (The flux with a maximum chlorine content of 0.2 Wt% is recommended.) (2) Wave soldering · Temperature , solder including plastic mold portion.) · Flux Rosin flux containing small amount of chlorine (The flux with a maximum chlorine content of 0.2 Wt% is recommended.) (3) Soldering by soldering iron · ... Original
datasheet

12 pages,
814.39 Kb

PS2521L-1-F3 PS2521L-1-A PS2521L-1 PS2521-1 ps2521 PS2521-1 abstract
datasheet frame

Extended Electronics Archive (Experimental)

Abstract Saved from Date Saved File Size Type Download
Over 1.1 million files (1986-2013): html articles, reference designs, gerber files, chemical content, spice models, programs, code, pricing, images, circuits, parametric data, RoHS data, cross references, pcns, military data, and more. Please note that due to their age, these files do not always format correctly in modern browsers. Disclaimer.
 
Notice (storage and operating condition) < SOLDERING > 1. Rosin-based flux is to be used. Do not use strong acidic flux with halide content exceeding 0.2%wt. (chlorine conversion value) 2. When soldering, do not exceed 5 seconds and keep 240�� to 260�� 3. When soldering, avoid . Do not use products in a chemical atmosphere such as chlorine gas, acid or sulfide gas. 2. Do humidity. 2. Do not store products in a chemical atmosphere such as chlorine gas, acid or sulfide
www.datasheetarchive.com/files/murata/products/data/a03x/ee1_xxx1.txt
Murata 09/08/2000 2.43 Kb TXT ee1_xxx1.txt
Notice of Lead Type EMI filter < SOLDERING > 1. Rosin-based flux is to be used. Do not use strong acidic flux with halide content exceeding 0.2%wt. (chlorine conversion value) 2. When soldering, do not exceed 5 seconds and keep 240°C to 260°C 3. When soldering, avoid mechanical stress such as chlorine gas, acid or sulfide gas. 2. Do not use products near water, oil or organic chemical atmosphere such as chlorine gas, acid or sulfide gas.
www.datasheetarchive.com/files/murata/products/data/a03x/te1_xxxe.txt
Murata 12/10/1996 2.46 Kb TXT te1_xxxe.txt
Notice (storage and operating condition) < SOLDERING CONDITIONS > 1. Flux, Solder �Rosin-based flux should be used. Do not use strong acidic flux with halide content exceeding 0.2%wt (chlorine conversion value.) �Use 63/37 solder (Sn 63%/Pb 37%) or 60/40 solder (Sn 60%/Pb 40%) 2. Flow soldering �Products should be soldered by flow method under the following humidity. Don't keep products in corrosive gases such as sulfur, chlorine gas or acid, or it
www.datasheetarchive.com/files/murata/products/data/a03x/ee2_xxx1.txt
Murata 14/01/2000 1.29 Kb TXT ee2_xxx1.txt
Chip monolithic ceramic capacitors (chips) can experience degradation of termination solderability when subjected to high temperature or humidity, or if exposed to sulfur or chlorine gases. (Reference Data 1. Solderability)
www.datasheetarchive.com/files/murata/products/data/a18x/c2eb1m.txt
Murata 03/07/2000 0.22 Kb TXT c2eb1m.txt
The component will be damaged when an excessive stress is applied. All kinds of reflow soldering must not be applied to the leaded ceramic filter in plastic case. Do not clean or wash the component as it's not hermetically sealed. Do not use strong acidity flux, more than 0.2wt% chlorine content, in re-flow soldering.
www.datasheetarchive.com/files/murata/products/data/a07x/senjonge.txt
Murata 27/05/1999 0.33 Kb TXT senjonge.txt
Please do not apply an excess stress to ceramic filter as it may damage component. All kinds of reflow soldering must not be applied on this component. On flow soldering, do not use strong acidity flux (more than 0.2wt% chlorine content).
www.datasheetarchive.com/files/murata/products/data/a07x/e71g1501.txt
Murata 06/09/1996 0.25 Kb TXT e71g1501.txt
such as chlorine gas, acid or sulfide gas. < STORAGE AND HANDLING REQUIREMENTS > 1. Storage Period such as chlorine gas, acid or sulfide gas.
www.datasheetarchive.com/files/murata/products/data/a03x/ee0_xxx1.txt
Murata 09/08/2000 2.2 Kb TXT ee0_xxx1.txt
such as chlorine gas, acid or sulfide gas. < STORAGE AND HANDLING REQUIREMENTS > 1. Storage Period such as chlorine gas, acid or sulfide gas.
www.datasheetarchive.com/files/murata/products/data/a03x/te0_xxxe.txt
Murata 22/10/1999 2.18 Kb TXT te0_xxxe.txt
exceeding 0.2%wt (chlorine conversion value) Use 63/37 solder (Sn 63%/Pb 37%) or 60/40 solder in temperature and humidity. Chemical exposure to sulfur, chlorine gas or acid may
www.datasheetarchive.com/files/murata/products/data/a03x/te2_xxxe.txt
Murata 06/09/1996 2.11 Kb TXT te2_xxxe.txt
NOTICE Note the following to prevent quality degradation. 1. Store the capacitors in an environment whose tempetature and relative humidity range from -10 to 40% and 30 to 70%RH respectively and away from direct sunlight and shock. 2. Avoid storing the capacitors in an atmosphere containing corrosive gases (chlorine, hydrogen sulfide, oxidation sulfur, nitrogen oxide etc.). 3. Do not directly touch capacitors with hands. 4. Please consult us in advance when using mounting
www.datasheetarchive.com/files/murata/products/data/a04x/k98mce02.txt
Murata 26/06/1998 0.55 Kb TXT k98mce02.txt