500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Top Results

Part Manufacturer Description Datasheet BUY
X9313UMZ-3T1 Intersil Corporation Digitally Controlled Potentiometer, Linear, 32 Taps, 3 Wire Interface, Terminal Voltages ± VCC; MSOP8, PDIP8, SOIC8; Temp Range: See Datasheet visit Intersil Buy
X9313WMZ-3 Intersil Corporation Digitally Controlled Potentiometer, Linear, 32 Taps, 3 Wire Interface, Terminal Voltages ± VCC; MSOP8, PDIP8, SOIC8; Temp Range: See Datasheet visit Intersil Buy
X9313ZMIZT1 Intersil Corporation Digitally Controlled Potentiometer, Linear, 32 Taps, 3 Wire Interface, Terminal Voltages ± VCC; MSOP8, PDIP8, SOIC8; Temp Range: See Datasheet visit Intersil Buy
X9313ZSZ Intersil Corporation Digitally Controlled Potentiometer, Linear, 32 Taps, 3 Wire Interface, Terminal Voltages ± VCC; MSOP8, PDIP8, SOIC8; Temp Range: See Datasheet visit Intersil Buy
X9313UMZ Intersil Corporation Digitally Controlled Potentiometer, Linear, 32 Taps, 3 Wire Interface, Terminal Voltages ± VCC; MSOP8, PDIP8, SOIC8; Temp Range: See Datasheet visit Intersil Buy
X9313WPZ-3 Intersil Corporation Digitally Controlled Potentiometer (XDCP™), Linear, 32 Taps, 3 Wire Interface, Terminal Voltages ± VCC; MSOP8, PDIP8, SOIC8; Temp Range: See Datasheet visit Intersil Buy

center tap voltage transformer

Catalog Datasheet MFG & Type PDF Document Tags

230v input to 12v output as step down transformer

Abstract: 12V DC to 230V AC inverters circuit diagram be seen that the transformer secondary voltage can be specified as 28VCT (center tap). For a bridge , the transformer current can be approximated as: For a Full-Wave Center Tap 1.2 x 0.35 = 0.42 A or , a Full-Wave center tap application Secondary rating: 28 VCT @ 0.42 A Approx. transformer power , . Transformer Secondary Current VREG REG C + VOUT DC Full-Wave center tap 1. VREG is , 4 diodes. The extra diodes result in double the voltage drop as that in a center tap circuit
ZETTLER Electronics
Original
230v input to 12v output as step down transformer 12V DC to 230V AC inverters circuit diagram 230v to 12v center tap transformer 230v ac 5v adapter circuit schematic 230v to 12v ac step down transformer 230v 50 Hz CENTER TAP transformer

ethernet transformer Application Note

Abstract: ethernet transformer center tap twisted pair medium, and the PD takes the 48V differential off the center tap of the transformer of the , differential voltage (Vport) onto the center taps of the PSE side of the transformer and looks for a valid PD , DC component other than the typical 3.3V pull-up on the center tap of the transformer for analog , transformer center tap and RX transformer center tap, giving a 0V differential between the two center taps , from the center taps of the transformer on the PD side of the twisted pair medium as shown below in
Standard MicroSystems
Original
ethernet transformer Application Note ethernet transformer center tap center tap transformer 18 0 18 ethernet transformer centre tap schematic diagram 48V power supply Poe center tap transformer IEEE802

Design -5V dc power supply using center-tapped transformer

Abstract: erj8enf1001 center tap of the RF transformer is driven by the VCM output pin of the SPT7864/66 which is typically , center tap of the RF transformer at the RF-IN connection. Note that series damping resistors (value , V. The transformer's secondary center tap pin may also be driven SPT AN7864/66 3 10/8/01 , clock transformer center tap. Not installed: allows the clock signals to be biased by the ADC , V of common-mode voltage, internally provided. The board supports straight AC transformer coupling
Signal Processing Technologies
Original
SPT7864 ED5044-ND H143-ND1 Design -5V dc power supply using center-tapped transformer erj8enf1001 input and output center tap transformer ECS-T1CY475R mfr-25fbf EB7864/66 RJ-8ENF1001 ERJ-8ENF4990 ERJ-8ENF5230 MFR-25FBF

center tap transformer for rf signal

Abstract: input and output center tap transformer to connector P1. Installed: allows a fixed voltage to be applied to the clock transformer center tap , 's secondary center tap pin may also be driven with approximately 1.6 V from a voltage divider or an external , Mini-Circuit T1-6T RF transformer (1:1, with center tap), center-tapped secondary with a 1 dB pass-band from , OUTPUT The center tap of the RF transformer is driven by the VCM output pin of the SPT7864/66/68 , capable of driving 50 µA, typically. It is used to drive the center tap of the RF transformer at the
Signal Processing Technologies
Original
center tap transformer for rf signal 7868 74VLT244 AD8138 tap control transformer H143 AN7864/66/68 EB7864/66/68 ERJ-8ENF2211 760-3-R47 40F6045 74LVT244

erj8enf1001

Abstract: AN786 : allows a fixed voltage to be applied to the clock transformer center tap. Not installed: allows the , . The transformer circuit consists of a Mini-Circuit T1-6T RF transformer (1:1, with center tap , accommodate the user's drive circuit. DIGITAL OUTPUT The center tap of the RF transformer is driven by , of driving 50 µA, typically. It is used to drive the center tap of the RF transformer at the RF-IN , normally provided by the ADC and is typically 1.5 V. The transformer's secondary center tap pin may also
Fairchild Semiconductor
Original
AN786 ECU-V1H102KBM ECU-V1H103KBM SPT7866 Amphenol Assembly instructions

MIL-STD-1553 cable connector

Abstract: MIL-STD-1553 connector widths of 0.04" (2.5mm) and use short, direct paths for transformer signal and center tap conductors. Ground and Power Planes When transmitting, the transformer center tap (on the transceiver IC side , -1553 Protocol Logic * This center tap is GND often not connected Shielded Twisted Pair MIL-STD , Bus Transceiver N = 1:1.41 * This center tap is often not connected GND , width for the center tap should at least match the analog drive conductor width, but ground plane can
HOLT Integrated Circuits
Original
AN-550 HI-1573 MIL-STD-1553 cable connector MIL-STD-1553 connector HI-1573PS 1553 coupler MIL-HDBK-1553A SMD 2512 resistors MIL-STD-1553 MILSTD-1553 MIL-STD-1553B MIL-STD1553

CATV Wideband Transformer Splitter

Abstract: agilent ads balun baluns/transformers and a diode quad. Center tap of the LO transformer is grounded and center tap of the , APPLICATION NOTE For Balanced to balanced transformation, choose a transformer with center tap on both , shows a push-pull amplifier using transistors. Base biasing is applied through center tap of T1 and , parameters and applications Conventional transformers made of core-and-wire optionally have center tap on , Balun applications, choose a balun with center tap on balanced side as it provides excellent amplitude
Mini-Circuits
Original
AN-20-002 LT5514 AN20002 CATV Wideband Transformer Splitter agilent ads balun TC1-1-13 How RF Transformers Work HELA-10 M127387
Abstract: , it consists of a pair of 1:4 baluns/transformers and a diode quad. Center tap of the LO transformer is grounded and center tap of the RF Balun (right) is used for extracting IF (See Figure 14). 9.5 , applied through center tap of T1 and collectors through T2. Configurations A,B and F can be used for this , optionally have center tap on primary or secondary or on both sides and are limited to an upper frequency of , lowest insertion loss. For Balun applications, choose a balun with center tap on balanced side as it Mini-Circuits
Original
M150261
Abstract: tap of the LO transformer is grounded and center tap of the RF Balun (right) is used for extracting , Transformer? A Transformer is a passive device that â'transformsâ' or converts a given impedance, voltage , Equations Figure 4: Transformer showing dot convention with respect to voltage and current direction , transistors. Base biasing is applied through center tap of T1 and collectors through T2. Configurations A , core-and-wire optionally have center tap on primary or secondary or on both sides and are limited to an upper Mini-Circuits
Original

b-3067

Abstract: BUS-25679 -61590 Universal ACE and the BUS-65149RT hybrid, the transformer center tap, pin 2, MUST NOT be grounded. The , (with the opposite signal polarity). If the transformer center tap is grounded, there is a strong , output stage, through one leg of the isolation transformer to the transformer center tap. It is important to realize that the high current path is through the transformer center tap and not through the , polarity signals. For the BU-61590 or BUS-65149, the transformer center tap must not be grounded. In
Data Device
Original
BU-65620 b-3067 BUS-25679 ddc b-3067 HLP-6002 datasheet center tapped transformer AN/B-27 1-800-DDC-5757 A5976
Abstract: outlets (6 right-angle outlets and 1 designated transformer outlet) 4-ft. cord 1080 joule rating $25 , total outlets (6 at right angle and 1 designated transformer plug outlet), 4 foot cord and diagnostic , from the strongest surges and line noise 7 total AC outlets (6 right angle and 1 transformer plug , convenient wall/desk mounting UL1449 3rd Edition Rated (400V all modes), UL1363 (Power Tap), cUL (Canada , / type 7 NEMA 5-15R Transformer accommodation Supports 1 large transformer plug accessory Tripp Lite
Original
TLP74R NEMA5-15P/O NEMA5-15R/4- NEMA5-15R
Abstract: , it consists of a pair of 1:4 baluns/transformers and a diode quad. Center tap of the LO transformer is grounded and center tap of the RF Balun (right) is used for extracting IF (See Figure 14). 9.5 , Balanced to balanced transformation, choose a transformer with center tap on both primary and secondary , transformers made of core-and-wire optionally have center tap on primary or secondary or on both sides and are , lowest insertion loss. For Balun applications, choose a balun with center tap on balanced side as it Mini-Circuits
Original
Abstract: Highlights 7 outlets (6 right-angle outlets and 1 designated transformer outlet) 4-ft. cord 1080 joule , total outlets (6 at right angle and 1 designated transformer plug outlet), 4 foot cord and diagnostic , from the strongest surges and line noise 7 total AC outlets (6 right angle and 1 transformer plug , ), UL1363 (Power Tap), cUL (Canada) Exceeds IEEE 587 category A & B surge suppression specifications $25 , Breaker (amps) 15 Outlet quantity / type 7 NEMA 5-15R Transformer accommodation Supports 1 Tripp Lite
Original
TLP74RB

centertapped transformer

Abstract: tap of the transformer. This capacitor helps to stabilize the voltage on the supply line and protects , transformer ET product to the center tap for an application with VDD (max) = 5.5V, is 13.1V-µs. An application with VDD (max) = 3.3V has a transformer ET product to the center tap requirement of 7.9V-µs. , primary-to-secondary transformer winding ratio can be chosen to adjust the isolated output voltage. The device allows up to 500mA of current into the primary transformer winding with a supply voltage up to +5.5V.
Maxim Integrated Products
Original
centertapped transformer MAX258
Abstract: power supply. The transformer secondary voltage should be approximately .8 times the DC voltage of the unregulated power supply per side of the center tap or the transformer should be 1.6 times VDC center tapped , VOLTAGE (VO LTS) RMS CURRENT (AM PS) Full-Wave Center Tap Full-Wave Bridge Dual Complementary , supplies used: 1) 2) 3) 4} The ferroresonant transformer will supply a constant output voltage over a wide variation of the transformer input voltage. The problems with using a ferroresonant power -
OCR Scan
15VDC
Abstract: tap of the transformer. This capacitor helps to stabilize the voltage on the supply line and protects , transformer ET product to the center tap for an application with VDD (max) = 5.5V, is 13.1V-µs. An application with VDD (max) = 3.3V has a transformer ET product to the center tap requirement of 7.9V-µs. , primary-to-secondary transformer winding ratio can be chosen to adjust the isolated output voltage. The device allows up to 500mA of current into the primary transformer winding with a supply voltage up to +5.5V. Maxim Integrated Products
Original

BU-63133L8

Abstract: BU63133L8 transformer coupled, MIL-STD-1553 Bus implementation. The center tap of the primary winding (the side of the , possible and with the shortest leads to the center tap of the transformer(s) and ground plane. Furthermore, when transmitting, large currents will flow from the 3.3V plane, into the transformer center tap , ISOLATION TRANSFORMER BETA P/N LVB-4203/B-3372 COUPLING TRANSFORMER NOTES: 1. Transformer center tap , with the shortest leads to the center tap of the transformer(s) and ground. 2. The BU-63133 should have
Data Device
Original
BU-63133L8 BU63133L8 DLVB-4233 DLVB-4213 harris 15530 DSS-1003 MIL-STD-883 B-09/05-0

LVB-4213

Abstract: BU63133L8 transformer coupled, MIL-STD-1553 Bus implementation. The center tap of the primary winding (the side of the , possible and with the shortest leads to the center tap of the transformer(s) and ground plane. Furthermore, when transmitting, large currents will flow from the 3.3V plane, into the transformer center tap , possible, and with the shortest leads to the center tap of the transformer(s) and ground. 2. The BU , Capacitance (Notes 1-6, 12) Threshold voltage, transformer Coupled, Measured on Stub (Note 7) Common-Mode
Data Device
Original
LVB-4213

center tap transformer

Abstract: Pulse Transformer AES3 side of the system is connected to the center tap of the output transformer. The remote device gets DC power from the input transformer's center tap. Decoupling filters should be used on both ends. 10.4 , CENTER TAP TRANSFORMER CABLE CENTER TAP TRANSFORMER PHANTOM POWER SOURCE Fig. 21 Dual Output Transmitter 110 Balanced / 75 Unbalanced TRANSMITTER CENTER TAP TRANSFORMER 1:1 UNBAL 75 S OUT 110 , has less margin and interference rejection. A step-up transformer can increase the signal voltage
-
Original
Pulse Transformer AES3 SMALL high frequency transformer Design of H.F. Wideband Power Transformers Design of H. F. Wideband Power Transformers SC979-03 audio transformer
Abstract: transformer accommodation INPUT Nominal Input Voltage(s) Supported 120V AC Recommended Electrical , between transformer outlets = 57mm Keyhole slot center to center measurement Distance between , off unused outlets. Attractive white housing with keyhole mounting slots and 3 designated transformer , ) FORMAT: Corded multi-outlet strip with transformer spaced outlets SUPPRESSION AC: 150V RMS Clamping/1440 , outlets with 3 transformer plug outlet that doesn't block remaining outlets 25 foot AC line cable Tripp Lite
Original
TLP825 NEMA5-15R/25 50/60H
Showing first 20 results.