SLUA455 bq27500 bq2750x SLUA450 SLUA449 bq2750xEVM SLUU287 SLUU307 EV2300 C/100 - Datasheet Archive
SLUA455 March 2008 Impedance Track Fuel Gauge Accuracy Test for GSM Phone Applications Ming Yu and Michael
Application Report SLUA455 SLUA455 March 2008 Impedance Track Fuel Gauge Accuracy Test for GSM Phone Applications Ming Yu and Michael Vega. Battery Management Solutions ABSTRACT The Texas Instruments Impedance TrackTM (IT) fuel gauge is designed for reporting remaining battery capacity and run time accurately. To effectively accomplish this reporting a real application environment must be used for test results. The test board should be designed as similar to the real application circuit as possible. This application report outlines the procedure for implementing an accuracy test for GSM and Smart phone applications using the TI System Side Single Cell Impedance Track Fuel Gauge bq27500 bq27500. The test setups, battery chemistry selection, and battery learning cycle are discussed in this report. Finally, the test results demonstrate that less than 1% remaining capacity accuracy can be achieved by the Impedance Track Fuel Gauge. 1 2 3 Contents Impedance Track Algorithm Background . 1.1 References . GSM Phone Accuracy Test Preparation . 2.1 GSM Phone Application . 2.2 Accuracy Test Requirements . 2.3 Chemistry Selection Cycling . 2.4 Battery Cell Learning Cycling . 2.5 Generate the Golden Image and Update bq27500 bq27500 Flash Content . GSM Phone Accuracy Test and Results . 1 2 2 2 3 4 5 6 6 List of Figures 1 2 3 4 5 6 7 1 Test Setup With Battery Cell . Configuration of Load Circuit . Learning Cycle Flow Chart . Phone-RSOC and Discharge Current vs. Discharge Time . Phone-RSOC and Battery Voltage vs. Discharge Time . Phone-RSOC Accuracy vs. RSOC . Phone-Remaining Capacity Accuracy vs. RSOC . 4 5 5 6 7 7 8 Impedance Track Algorithm Background The gas gauge algorithm uses three types of information to calculate Remaining Capacity (RM) and Full Charge Capacity (FCC): · Chemical-Depth of Discharge (DOD), and maximum chemical capacity Qmax · Electrical-internal battery resistance dependence on DOD, or State of Charge (SOC). SOC equals 1 minus DOD. · External-load and temperature. Full Charge Capacity is defined as the amount of charge passed from a fully charged state until the system Terminate Voltage is reached at a given rate of discharge (after subtracting the reserve capacity). Impedance Track is a trademark of Texas Instruments. Arbin Instruments is a trademark of Arbin Instruments. SLUA455 SLUA455 March 2008 Submit Documentation Feedback Impedance Track Fuel Gauge Accuracy Test for GSM Phone Applications 1 www.ti.com GSM Phone Accuracy Test Preparation Note: FCC depends on the rate of discharge and is lower at higher rates and low temperatures because the cell I*R drop causes the Terminate Voltage threshold to be reached early. Relative State of Charge (RSOC) is defined as: RSOC = (RM × 100) ÷ FCC The algorithm differentiates between charge, discharge and relaxation modes of operation. See the Theory and Implementation of Impedance TrackTM Battery Fuel-Gauging Algorithm in bq2750x bq2750x Family (SLUA450 SLUA450) application report for additional details. These items are updated by the Impedance Track algorithm: · Chemical Depth of Discharge (DOD) or State of Charge (SOC = 1 DOC) · Qmax · Resistance · Temperature Model · Remaining Capacity (RM) and Full Charge Capacity (FCC) The Relative State of Charge (RSOC) Error is defined as: RSOC Error = RSOC calculated RSOCreported where RSOCcalculated = (FCC Qstart PassedQ) × 100 ÷ FCC and RSOCreported is the RSOC reported by bq27500 bq27500 Impedance Track algorithm. Remaining Capacity Error is defined as: RM Error = (RMcalculated RMreported ) ÷ FCC where RM calculated = FCC Qstart PassedQ and RM reported is the RM reported by bq27500 bq27500 Impedance Track algorithm. PassedQ is passed charge from the beginning of discharge to present. Qstart is the starting charge at the beginning of discharge. 1.1 References For additional information related to this application report, see: · Theory and Implementation of Impedance TrackTM Battery Fuel-Gauging Algorithm in bq2750x bq2750x Family (SLUA450 SLUA450) · Going to Production with the bq2750x bq2750x (SLUA449 SLUA449) · bq2750xEVM bq2750xEVM System Side Single-Cell Impedance TrackTM Technology Evaluation Module (SLUU287 SLUU287) · bqEASY for Single Cell Impedance TrackTM Devices (SLUU307 SLUU307) 2 GSM Phone Accuracy Test Preparation 2.1 GSM Phone Application Unlike notebook battery applications having a relatively constant load profile, cell phones, smart phones, or PDAs (GSM, CDMA, 3G GSM or 3G CDMA communication protocol dependent) have a pulsating load profile. This application type always raises questions regarding, "how well Impedance Track can accurately predict the battery remaining capacity and what is the impact of the pulsating current?" In this example, a NOKIA 6106b GSM phone is used to check the Impedance Track accuracy. As mentioned in Theory and Implementation of Impedance TrackTM Battery Fuel-Gauging Algorithm in bq2750x bq2750x Family (SLUA450 SLUA450) application report, the Qmax and Resistance can be updated only when certain criteria are met. There is some confusion that under a pulsating current, an accurate OCV reading may be difficult to achieve. In order to reveal the truth, this criteria should be carefully examined. 2 Impedance Track Fuel Gauge Accuracy Test for GSM Phone Applications SLUA455 SLUA455 March 2008 Submit Documentation Feedback www.ti.com GSM Phone Accuracy Test Preparation First, zero current is not needed for an Open Circuit Voltage (OCV) reading. Only a low current (that is, less than C/20 rate) is needed. This is very common in cell phone and smart phone applications when they are in standby mode. During the relaxation, a short spike current pulse does not wake-up the gauge from relaxation mode. The current must remain high and exceed a specified time limit for the cell to exit the relaxation mode. Second, if a single voltage read point is taken exactly at the moment of the spike, it is ignored because the Impedance Track checks if the current exceeded a specific current threshold. If it does, Impedance Track uses the previous OCV reading. 2.2 Accuracy Test Requirements To correctly measure and calculate the Remaining Capacity (RM) and Full Charge Capacity (FCC) to get Relative State of Charge (RSOC), (1) the battery cell chemistry must be accurately selected through battery chemistry selection cycling and (2) the battery cell resistance profile must be accurately learned through battery cell learning cycle. Before starting all battery cycling, the Print Circuit Board (PCB) with bq27500 bq27500 should be carefully calibrated. Check application report Going to Production with the bq2750x bq2750x (SLUA449 SLUA449) for the correct calibration procedure. The test setup (Figure 1) includes: · A bq27500 bq27500 EVM or any application specified test board with bq27500 bq27500. · A PC with the bq Evaluation Software properly installed. · A PC USB interface that is connected to the EV2300 EV2300 communication module. See the bq2750xEVM bq2750xEVM System Side Single-Cell Impedance TrackTM Technology Evaluation Module (SLUU287 SLUU287) application report for detailed setup requirements. The GSM phone original BL-4C battery pack is modified. The battery cell is carefully removed from the original battery pack. The cell protection circuit board is removed to expose the positive and negative terminal. The original thermistor is discarded. For proper operation of the phone, the thermistor terminal on the phone is connected to the thermistor on test board. The battery terminals from the phone then connect to battery terminals through wires. See Figure 1 for battery cell modification and test setup. SLUA455 SLUA455 March 2008 Submit Documentation Feedback Impedance Track Fuel Gauge Accuracy Test for GSM Phone Applications 3 www.ti.com GSM Phone Accuracy Test Preparation Figure 1. Test Setup With Battery Cell PC/bqEVSW EV2300 EV2300 Nokia 6106 Thermistor 2 I C BL_4C bq27500 bq27500 EVM Load Cell 2.3 + Pack Pack+ Load+ Chemistry Selection Cycling The battery cell chemistry must be carefully selected. The bq Evaluation Software provides a procedural tool called bqEASY that helps the user to set up the cell, based on the cell manufacturer specification and system requirements to do the chemistry selection cycle. bqEASY uses a four-point method for chemistry selection and the results are usually within 1% error of the actual chemistry learned from more sophisticated cycling system, such as the Arbin InstrumentsTMsystem. TI offers the help for customer who needs to identify the cell chemistry using the Arbin Instruments system. The Arbin Instruments system takes more points when determining the cell chemistry, therefore it takes longer. bqEASY has a chemistry database with most known chemistries that have been characterized in TI using the Arbin Instruments system. If the battery cell chemistry can not be matched to any known profiles, the battery cell needs to be sent back to TI to determine the actual chemistry through the Arbin Instruments system and a new profile can be generated. For bqEASY to select the chemistry correctly, the cell must be charged very close to its maximum cell voltage. Normally, this is 4.2 V, before the chemistry selection cycling. The charge taper current should be less than C/100 C/100 when charging is terminated. A programmable electronic load or resistor is also needed to generate a less than C/5 discharge rate during the discharge cycle. The chemistry selection cycle requires a controlled load profile (see Figure 2). The EV2300 EV2300 HDQ port is used to periodically turn on the load using the FET or relay. 4 Impedance Track Fuel Gauge Accuracy Test for GSM Phone Applications SLUA455 SLUA455 March 2008 Submit Documentation Feedback www.ti.com GSM Phone Accuracy Test Preparation Figure 2. Configuration of Load Circuit Electronic Load or Resistor ~ C/5 EV2300 EV2300 HDQ Connector EVM Load+ VOUT 100 kW Load GND Use N-CH FET with low Vgs or small 5V coil relay such as OMRON G6RN-1 Chemistry selection cycling will select the correct chemistry profile from the bqEASY built-in chemistry database and program these values into the bq27500 bq27500 data flash for Impedance Track algorithm to use. 2.4 Battery Cell Learning Cycling The battery learning cycle is used to obtain the actual cell Qmax and cell resistance value, updated based on the chemistry determined from Chemistry Selection Cycling. It is very critical that the correct chemistry be selected before proceeding with learning cycling. A complete learning cycle consists of the procedure shown in Figure 3. Before starting the learning cycle, if the chemistry is known, the chemistry profile should be programmed into bq27500 bq27500 data flash and the test board should be calibrated. During the learning cycle, Qmax is updated twice. The first Qmax update happens after the charge cycle during the two-hour relaxation period. The second Qmax update happens after the second discharge cycle during the five-hour relaxation period. See the Theory and Implementation of Impedance TrackTM Battery Fuel-Gauging Algorithm in bq2750x bq2750x Family (SLUA450 SLUA450) application report for more information. Figure 3. Learning Cycle Flow Chart Calibration is completed Chemistry profile is programmed Fully discharge cell to Terminate Voltage with C/5 discharge rate Charge cell to Full Charge Voltage with CC/CV method. (Max charge rate 1C Terminate charging when taper current < C/100 C/100) Wait 5 hrs Cell Relax Enable IT Wait 2 hrs Cell Relax Generate Golden Image Save DFI file SLUA455 SLUA455 March 2008 Submit Documentation Feedback Update Status = 02 Wait 5 hrs Cell Relax Second Qmax update First Qmax update Discharge cell to Terminate Voltage with C/5 rate. Ra updated Impedance Track Fuel Gauge Accuracy Test for GSM Phone Applications 5 www.ti.com GSM Phone Accuracy Test and Results 2.5 Generate the Golden Image and Update bq27500 bq27500 Flash Content After the cell learning cycle has completed the final five-hour relaxation, bq27500 bq27500 is ready to be updated with the golden image (flash contents learned during the cycling). bqEASY provides the user-interface that helps you generate the golden image file and at the correct time, update the necessary flash contents with the value learned during the learning cycle. This includes updating the OCV table with correct Qmax value, updating all the resistance tables with learned resistance values, resetting the cycle count, disabling the Impedance Track algorithm for mass programming, and so forth. Once the golden image is programmed into bq27500 bq27500, the set up is ready for real application testing. 3 GSM Phone Accuracy Test and Results The Nokia 6106 GSM phone used in this test is a registered phone. During the test, actual phone calls in and out of this phone along with applications such as playing games are carried out. The battery voltage and the discharge current are logged with time stamp. Using TI provided bq Evaluation software, the logging process can be easily implemented. The logging information is needed for post-processing to obtain the accuracy results. Depending on the battery capacity and the actual application, the total test time can range from five to nine hours. In this test, the LCD screen is frequently turned on to maximize the phone battery use. As shown in Figure 4, the discharge current reported by the Impedance Track is being averaged by the Analog to Digital Converter (ADC) in bq27500 bq27500 and by the Impedance Track algorithm. Although the GSM phone is running on GSM protocol (1) but the reported peak current is around 200 mA when the phone's LCD screen is on and only around 80 mA when the screen is off. When receiving a call, the current spike can go up to between 300 mA and 400 mA. Figure 4. Phone-RSOC and Discharge Current vs. Discharge Time 0 80 100 60 200 Current 40 300 20 Discharge Current - mA RSOC - Relative State of Charge - % 100 400 RSOC 0 0:00 (1) 6 1:23 3:13 5:01 500 6:41 t - Time - Hours:Minutes GSM waveform: 1 A for 0.48 ms and 72 mA for 4.76 ms. Impedance Track Fuel Gauge Accuracy Test for GSM Phone Applications SLUA455 SLUA455 March 2008 Submit Documentation Feedback www.ti.com GSM Phone Accuracy Test and Results Figure 5. Phone-RSOC and Battery Voltage vs. Discharge Time 4200 80 4000 Voltage 60 3800 40 3600 Battery Voltage - mV RSOC - Relative State of Charge - % 100 RSOC 3400 20 0 0:00 1:23 3:13 3200 6:41 5:01 t - Time - Hours:Minutes The RSOC accuracy for this particular test is calculated from the data log file and Figure 6 shows the RSOC accuracy during the entire discharge cycle. As the discharge starts, the error is about 1%, but as the phone goes into standby mode, which is around RSOC = 80%, the accurate OCV reading is taken by the Impedance Track, ir regardless of the high current spikes happening (with delay). Figure 6. Phone-RSOC Accuracy vs. RSOC RSOC - Relative State of Charge Accuracy - % 1 0 1 2 3 0 10 20 30 40 0 60 70 80 90 100 RSOC - Relative State of Charge - % This test has proved that the Impedance Track algorithm works as expected even for pulsating load profile. The high current spike does not affect Impedance Track accuracy. SLUA455 SLUA455 March 2008 Submit Documentation Feedback Impedance Track Fuel Gauge Accuracy Test for GSM Phone Applications 7 www.ti.com GSM Phone Accuracy Test and Results The Remaining Capacity accuracy is calculated. This is one of the critical parameters that can predict the actual run time of the cell phone. As shown in Figure 7, the RM accuracy is within 1%. During the entire application cycle, the Impedance Track algorithm has made multiple RM adjustments based on the load current, the battery temperature, and so forth. The bq27500 bq27500 has very accurately reported the remaining capacity with less than 1% error during the entire discharge cycle. Figure 7. Phone-Remaining Capacity Accuracy vs. RSOC Remaining Capacity Accuracy - % 0.5 0 0.5 1.0 1.5 0 10 20 30 40 0 60 70 80 90 100 RSOC - Relative State of Charge - % 8 Impedance Track Fuel Gauge Accuracy Test for GSM Phone Applications SLUA455 SLUA455 March 2008 Submit Documentation Feedback IMPORTANT NOTICE Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to TI's terms and conditions of sale supplied at the time of order acknowledgment. TI warrants performance of its hardware products to the specifications applicable at the time of sale in accordance with TI's standard warranty. Testing and other quality control techniques are used to the extent TI deems necessary to support this warranty. Except where mandated by government requirements, testing of all parameters of each product is not necessarily performed. TI assumes no liability for applications assistance or customer product design. Customers are responsible for their products and applications using TI components. To minimize the risks associated with customer products and applications, customers should provide adequate design and operating safeguards. TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right, copyright, mask work right, or other TI intellectual property right relating to any combination, machine, or process in which TI products or services are used. Information published by TI regarding third-party products or services does not constitute a license from TI to use such products or services or a warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the third party, or a license from TI under the patents or other intellectual property of TI. Reproduction of TI information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompanied by all associated warranties, conditions, limitations, and notices. Reproduction of this information with alteration is an unfair and deceptive business practice. TI is not responsible or liable for such altered documentation. Information of third parties may be subject to additional restrictions. Resale of TI products or services with statements different from or beyond the parameters stated by TI for that product or service voids all express and any implied warranties for the associated TI product or service and is an unfair and deceptive business practice. TI is not responsible or liable for any such statements. TI products are not authorized for use in safety-critical applications (such as life support) where a failure of the TI product would reasonably be expected to cause severe personal injury or death, unless officers of the parties have executed an agreement specifically governing such use. Buyers represent that they have all necessary expertise in the safety and regulatory ramifications of their applications, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any use of TI products in such safety-critical applications, notwithstanding any applications-related information or support that may be provided by TI. Further, Buyers must fully indemnify TI and its representatives against any damages arising out of the use of TI products in such safety-critical applications. TI products are neither designed nor intended for use in military/aerospace applications or environments unless the TI products are specifically designated by TI as military-grade or "enhanced plastic." Only products designated by TI as military-grade meet military specifications. Buyers acknowledge and agree that any such use of TI products which TI has not designated as military-grade is solely at the Buyer's risk, and that they are solely responsible for compliance with all legal and regulatory requirements in connection with such use. TI products are neither designed nor intended for use in automotive applications or environments unless the specific TI products are designated by TI as compliant with ISO/TS 16949 requirements. Buyers acknowledge and agree that, if they use any non-designated products in automotive applications, TI will not be responsible for any failure to meet such requirements. Following are URLs where you can obtain information on other Texas Instruments products and application solutions: Products Amplifiers Data Converters DSP Clocks and Timers Interface Logic Power Mgmt Microcontrollers RFID RF/IF and ZigBee® Solutions amplifier.ti.com dataconverter.ti.com dsp.ti.com www.ti.com/clocks interface.ti.com logic.ti.com power.ti.com microcontroller.ti.com www.ti-rfid.com www.ti.com/lprf Applications Audio Automotive Broadband Digital Control Medical Military Optical Networking Security Telephony Video & Imaging Wireless www.ti.com/audio www.ti.com/automotive www.ti.com/broadband www.ti.com/digitalcontrol www.ti.com/medical www.ti.com/military www.ti.com/opticalnetwork www.ti.com/security www.ti.com/telephony www.ti.com/video www.ti.com/wireless Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265 Copyright © 2008, Texas Instruments Incorporated