500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Top Results

Part Manufacturer Description Datasheet BUY
SN74ALS528D Texas Instruments Fuse-Programmable Identity Comparators 16-SOIC 0 to 70 visit Texas Instruments
LM8502TMX/NOPB Texas Instruments Intelligent Lighting Management Unit That Fuses a 1.2A Dual High-Side Flash LED Drive 30-DSBGA -30 to 85 visit Texas Instruments
LM8502TME/NOPB Texas Instruments Intelligent Lighting Management Unit That Fuses a 1.2A Dual High-Side Flash LED Drive 30-DSBGA -30 to 85 visit Texas Instruments Buy

Search Stock

Shift+Click on the column header for multi-column sorting 
Part
Manufacturer
Supplier
Stock
Best Price
Price Each
Ordering
Part : AB1FUSE435U5XB Supplier : Schneider Electric Manufacturer : Newark element14 Stock : - Best Price : - Price Each : -
Part : AB1FUSE435U5XJ Supplier : Schneider Electric Manufacturer : Newark element14 Stock : - Best Price : - Price Each : -
Part : AB1FUSE435U5XM Supplier : Schneider Electric Manufacturer : Newark element14 Stock : - Best Price : - Price Each : -
Part : AB1FUSE435U6X Supplier : Schneider Electric Manufacturer : Newark element14 Stock : - Best Price : $14.98 Price Each : $20.77
Part : AB1FUSE435U6XM Supplier : Schneider Electric Manufacturer : Newark element14 Stock : - Best Price : - Price Each : -
Shipping cost not included. Currency conversions are estimated. 

b1 fuse

Catalog Datasheet MFG & Type PDF Document Tags

b1 fuse

Abstract: UL1950 voltage from pair 1 to pair 2 2) Passing Criteria: a) No charring of cheesecloth indicator b1) fuse or wiring simulator (Bussmann MDL-2A fuse) does not interrupt b2) I2t < 100 A2-sec. c) Meet dielectric , by requiring that a wiring simulator (often represented by a 1.6A fuse) did not open during the test , Criteria2 1 M, L, F 600 V, 40 A, 1.5 sec a, b1, b2, c 2 M, L, F 600 V, 7 A, 5 sec. a , circuit a, c L 120 V, 25 A 30 min. or until open circuit a, b1, c 4 5 Notes 1
Tyco Electronics
Original
UL1950 b1 fuse UL-497A TR600 TS600-170

AD513

Abstract: MSOP-10 A1 VDD GND W1 B1 FUSE LINKS 1 SDA SCL The AD5172/73 is controlled using a 2 , . AD5172 W1 GND AD0 AD1 SDA SCL B1 W2 B2 FUSE LINKS 2 1 The AD5172/73 is a dual channel, 256-position, One-Time Programmable(OTP) digital potentiometer that employs fuse link , resistance value. After the final value is determined, a fuse blow command is executed which freezes the , AD5173 S 0 S = Start Condition A = Acknowledge OW = Overwrite fuse setting and program
Analog Devices
Original
MSOP-10 AD513 OP279 B 11 MSOP-10 AD 50K preset POT 100K preset 256-P AD5172/AD5173 AD5173BRM2 AD5173BRM10-R2 AD5173BRM10-RL7

AD5173BRMZ50

Abstract: VR 100K preset operating temperature: -40°C to +125°C FUNCTIONAL BLOCK DIAGRAMS A1 W1 B1 FUSE LINKS VDD 1 , SCL 04103-001 FEATURES Figure 1. AD5172 Functional Block Diagram W1 B1 W2 B2 APPLICATIONS FUSE LINKS VDD 1 GND AD0 AD1 SDA SCL RDAC REGISTER 1 ADDRESS DECODE 2 , (OTP) digital potentiometers1 that employ fuse link technology to achieve memory retention of , the resistance value. During OTP activation, a permanent blow fuse command freezes the wiper
Analog Devices
Original
AD5173BRMZ50 VR 100K preset AD8610 FDV301N FDV302P MO-187-BA RM-10 D04103-0-4/09

AD5172

Abstract: AD5173 available Software replaces µC in factory programming applications W1 A1 B1 FUSE LINKS VDD , SERIAL INPUT REGISTER SCL Figure 1. AD5172 W1 B1 W2 B2 APPLICATIONS 1 GND AD0 , programmable (OTP) digital potentiometers1 that employ fuse link technology to achieve memory retention of , position (analogous to placing epoxy on a mechanical trimmer). FUSE LINKS VDD RDAC REGISTER 1 , feature that allows for new adjustments even after a fuse has been blown. However, the OTP setting is
Analog Devices
Original
NDS0610 C04103

AD5173BRMZ10-RL7

Abstract: AD5172 programming applications A1 W1 B1 FUSE LINKS VDD 1 GND A2 W2 B2 2 RDAC , . AD5172 Functional Block Diagram W1 B1 W2 B2 APPLICATIONS 1 GND AD0 AD1 SDA SCL , blow fuse command freezes the wiper position (analogous to placing epoxy on a mechanical trimmer). , -position, one-time programmable (OTP) digital potentiometers 1 that employ fuse link technology to achieve memory , resolution, solid-state reliability, and superior low temperature coefficient performance. FUSE LINKS
Analog Devices
Original
AD5173BRMZ10-RL7 C04103-0-6/06

AD5172

Abstract: AD5173 available Software replaces C in factory programming applications A1 W1 B1 FUSE LINKS VDD , SERIAL INPUT REGISTER SCL Figure 1. AD5172 W1 B1 W2 B2 APPLICATIONS 1 GND AD0 , programmable (OTP) digital potentiometers1 that employ fuse link technology to achieve memory retention of , setting the resistance value. During OTP activation, a permanent blow fuse command freezes the wiper position (analogous to placing epoxy on a mechanical trimmer). FUSE LINKS VDD RDAC REGISTER 2
Analog Devices
Original

AD5172

Abstract: AD5173 Software replaces µC in factory programming applications A1 W1 B1 FUSE LINKS VDD 1 GND , REGISTER SCL Figure 1. AD5172 W1 B1 W2 B2 APPLICATIONS FUSE LINKS VDD 1 GND , channel, 256-position, one-time programmable (OTP) digital potentiometers1 that employ fuse link , , a permanent blow fuse command freezes the wiper position (analogous to placing epoxy on a , temporary OTP overwrite feature that allows for new adjustments even after the fuse has been blown
Analog Devices
Original
AD5173BRM100 AD5173BRM100-RL7 AD5173EVAL1
Abstract: Devices are Pb-Free and are RoHS Compliant A1 ELECTRICAL SCHEMATIC Fuse A2 Table 1. PIN DESCRIPTIONS 4-bump CSP Package Pin A1 A2 B1 & B2 Fuse Terminal 1 TVS Channel / Fuse Terminal 2 Device Ground GND B1 & B2 Description TVS PACKAGE / PINOUT DIAGRAMS Orientation Marking 1 2 A B 2 A2 B2 1 A1 A1 , Fusing time Fuse life time Stand-off quiescent current Break down voltage Conditions B1 and B2 floating , , CSP form factor. This device is designed for: http://onsemi.com · · · · Fuse Transient ON Semiconductor
Original
CM6136 567CA 000/T BRD8011/D CM6136/D
Abstract: A2 TVS Channel / Fuse Terminal 2 B1 & B2 GND B1 & B2 Device Ground PACKAGE / PINOUT , and B2 floating (Note 2) ROPEN Resistance after open fuse B1 and B2 floating tFUSE Fusing time B1 and B2 floating; I = 5 A (Note 3) tLIFE Fuse life time B1 and B2 floating; I = , pitch, CSP form factor. This device is designed for: â'¢ â'¢ â'¢ â'¢ http://onsemi.com Fuse , (CSP) â'¢ These Devices are Pbâ'Free and are RoHS Compliant ELECTRICAL SCHEMATIC Fuse A1 A2 ON Semiconductor
Original

CQM1-OD212

Abstract: CQM1-OD214 points/common, 1 circuit) Internal Current Consumption Fuse 90 mA max. at 5 VDC max. 7 A (one per common), one only Fuse is not user replaceable. Service Power Supply 15 mA min. at 24 VDC , Output LED OUT0 to OUT07 Internal Circuits 24 VDC COM Fuse 7A Terminal Connections 0 1 B0 A0 2 3 B1 A1 4 5 B2 A2 6 7 B3 A3 NC NC B4 A4 NC NC , points (16 points/common, 1 circuit) Internal Current Consumption Fuse 170 mA max. at 5 VDC 5 A
-
Original
CQM1-OD211 CQM1-OD212 CQM1-OD214 CQM1-OD213 CQM1-OD215 CQM1-OA221 a7 transistor OUT03 OUT04 CQM1-OA222 OUT00

194r-hs4e

Abstract: 195-GA10 230VDC Fuse Type/Size UL/ Class J (max size) 200A 400A BS88 DIN B1,B2 O,OO,COO CSA , fused or non-fused styles. Non-fused styles permit use of your own fuse blocks. Fused switches, with integral fuse carriers reduce panel space requirements while shortening wiring time and reduce cost. Some of the World's most common fuse styles are available: UL Class J & CC, Canadian HRCI-J & HRCII-C, British Standard BS88 and DIN ­ A fuse for nearly every application. 2 Reliability Accessories
-
Original
194r-hs4e 195-GA10 194R-NJ100P3 194R-NJ030P3 194R-NJ200P3 hs4e 500-13UNC 194R-NN800P3 194R-NN600P3 194R-NN600P 194R-NN800P 194R-SG001A-US-P

ABB CONVERTER E4

Abstract: Siba nh fuse Sicherungen für den Halbleiter- und Leitungsschutz gRL Fuse links for semiconductor and line , / fuse base Mikroschalter / Aux. Switch Artikel-Nr. Verzeichnis / part-no. index URL 2 techn , Fuse links for semiconductor and line protection gRL NH-Sicherungseinsätze nach DIN 43620 LV fuse , 250 A ³ 315 A £ 400 A ³ 450 A a1 b1 e4 e1 e2 f c1 47 47 65 65 65 65 , 40 48 48 60 60 Sicherungseinsätze nach DIN 43653 fuse links acc. DIN 43653 Abb. fig
SIBA
Original
ABB CONVERTER E4 Siba nh fuse Siba 20 209 20 SIBA 20 189 04 ABB NH000 NH000

BS88 fuse

Abstract: fix bolt Fuse Switches s On load fuse switch to IEC 947-3 s 3 and 4 pole versions s 20A to , 400V Amps Frame Size BS88 Fuse size Handles Black ­ Rotary Door Interlock Red/Yellow ­ Rotary Door , A2-A3 Ratings @ 400VAC AC22 AC23 Fuse size BS88 A A Making capacity @ 400VAC AC23B A , 500 Rated conditional short-circuit current BS88 kA Rms 80 80 80 100 Fuse switch , 0.5 1 1.3 2 Maximum Torque Settings (Nm) On terminal bolt/On fuse bolt On shaft
IMO
Original
CF793020 CF793032 SF793032 SF793063 SF793100 CF793N20 BS88 fuse fix bolt AC22 79E0018

bs88 fuse

Abstract: frame IEC-34-1 Fuse Switches s On load fuse switch to IEC 947-3 s 3 and 4 pole versions s 20A to , 6 6 B1-B4 7 8 Frame Size BS88 Fuse size Handles Black ­ Rotary Door Interlock Red , 400VAC AC22 AC23 Fuse size BS88 A A Making capacity @ 400VAC AC23B A Rms 200 320 , conditional short-circuit current BS88 kA Rms 80 80 80 100 Fuse switch cut off current kA , Maximum Torque Settings (Nm) On terminal bolt/On fuse bolt On shaft securing bolt Weight 3/4P Kg
IMO
Original
frame IEC-34-1 ops u 500 385 fuse bs88 79A0005 rotary series 2500 switch 79E0012 SF793160 SF793200 SF793250 SF793315 SF793400 SF793630

XPS-ASf

Abstract: XPS-ASF5142 Module fuse protection Control unit voltage between S11-S12, S21-S22 or S11-B1 Minimum voltage and , state outputs - max. thermal current (Ithe) - output fuse protection conforming to IEC 947-5-1, DIN , B S12 S21/S31 S22 S32 B1 Y1 Y2 23 13 Y34 XPS-ASF T ­ K1 + 115 V 230 V K1/K2 Fusible Fuse K2 K1 A2 A1/A2 Logic Logique PE S33/S41 S42 (3 , electronic fuse operating status (3) If no safety mats or edges are connected, terminals S33/41-S42 and S21
-
Original
S41-S42 DC-13 XPS-ASf XPS-ASF5142 XPS-AS XPS-ASF3442 xpsasf5142 XPS-Apf S11-S21 S31-S32 S33-S34 AC-15

S553-6500-B1

Abstract: Interwinding Capacitance pF max Sec Coil A S553-6500-B1 Coil B Coil A Coil B Coil A , SCHEMATIC S553-6500-B1 Primary 1 Coil A Secondary 16 15 3 14 5 12 Coil B 7 Primary 11 10 Secondary ©2001 Bel Fuse Inc. Specifications subject to change without notice. 05.01 Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 · Tel 201-432-0463 · Fax 201-432-9542 · , MECHANICAL S553-6500-B1 SUGGESTED PCB PAD LAYOUT 0.80 (20.32) MAX 0.100 (2.54) 0.375 (9.52
Bel Fuse
Original
S553-6500-B1 TM01105

kd 012GL

Abstract: fuse drawer for 5 x 20 or 6,3 x 32 mm fuses, with or without voltage selector (step switch) ­ Version with line filter/shield see page 113 Fuse drawer Pushbutton for front panel actuation Standard or Medical 50 75 100 Fuse drawer Bowden cable eliminates wiring between pushbutton and , are allready wired · the fuse drawer "Fingergrip" can be removed by hand · For added safety "Extra-Safe" fuse drawers are available. Extra-safe fuse drawers satisfy international standards for medical
SCHURTER
Original
kd 012GL

XPS ar

Abstract: AR351144P Module inputs fuse protection Start button monitoring Control unit voltage and current (between , current Output fuse protection Minimum current Minimum voltage Electrical durability Response time on , S52 S11 S12 A1 B1 S52 XPS AR XPS AR A2 B2 A1 B1 S21 A2 B2 S22 S11 S12 S11 S52 S22 A2 B2 A1 B1 S11 S21 A2 B2 S22 S11 S52 S1 S1 S2 , detected Start configurations Automatic start With start button monitoring ESC A1 B1 S33
-
Original
XPS ar AR351144P iso 14119 diagnost XPSAR371144 en iso 13850 XPSAR311144 954-1/EN/ISO 1088/ISO 954-1/ISO Y31/Y64 Y31/Y74 S11-S22
Abstract: A2 TVS Channel / Fuse Terminal 2 B1 and B2 GND B1 & B2 Device Ground MARKING DIAGRAM , Resistance A1 â' A2 B1 and B2 floating; TA = 25°C (Note 2) ROPEN Resistance after open fuse B1 , 3) tLIFE Fuse life time B1 and B2 floating; I = 2 A; TA = 25°C (Notes 3 and 4) IOFF , '¢ Fuse Transient Voltage Suppression (TVS) Electrostatic Discharge Protection Electrical Overstress , Footprint Chip Scale Package (CSP) â'¢ These Devices are Pbâ'Free and are RoHS Compliant Fuse A1 A2 ON Semiconductor
Original
CM6114 567CB CM6114/D
Abstract: switch for Bowdencable actuation, fuseholder with interchangeable fuse drawer for 5 x 20 or 6,3 x 32 mm , KD Fuse drawer Pushbutton for front panel actuation 50 75 100 Bowden cable eliminates wiring , elements are already wired · the fuse drawer "Fingergrip" can be removed by hand · For added safety "Extra-Safe" fuse drawers are available. Extra-safe fuse drawers satisfy international standards for medical , cut-out for the actuating part B1 Derating curves for fuseholder Fuses 5 x 20 mm 1-pole Admissible SCHURTER
Original
Showing first 20 results.