500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Yamatake Datasheet

Part Manufacturer Description PDF Type
APM-A3J1 Yamatake APM Series Compact Proximity Sensors Original
APM-A3K1 Yamatake APM Series Compact Proximity Sensors Original
APM-B3A1 Yamatake APM Series Compact Proximity Sensors Original
APM-B3B1 Yamatake APM Series Compact Proximity Sensors Original
APM-B3J1 Yamatake APM Series Compact Proximity Sensors Original
APM-B3K1 Yamatake APM Series Compact Proximity Sensors Original
APM-C3A1-S Yamatake APM Series Compact Proximity Sensors Original
APM-C3B1-S Yamatake APM Series Compact Proximity Sensors Original
APM-C3E1 Yamatake APM Series Compact Proximity Sensors Original
APM-C3J1 Yamatake APM Series Compact Proximity Sensors Original
APM-C3J1-S Yamatake APM Series Compact Proximity Sensors Original
APM-C3K1 Yamatake APM Series Compact Proximity Sensors Original
APM-C3K1-S Yamatake APM Series Compact Proximity Sensors Original
APM-D3A1 Yamatake APM Series Compact Proximity Sensors Original
APM-D3A1-S Yamatake APM Series Compact Proximity Sensors Original
APM-D3B1-S Yamatake APM Series Compact Proximity Sensors Original
APM-D3J1 Yamatake APM Series Compact Proximity Sensors Original
APM-D3J1-S Yamatake APM Series Compact Proximity Sensors Original
CY7200A1002 Yamatake Carbon Monoxide Transmitter Original
FE5V-TA6 Yamatake Photoelectric Switch Scan
Showing first 20 results.

Yamatake

Catalog Datasheet MFG & Type PDF Document Tags
Abstract: Yamatake-SIC Control Systems Co., Ltd. Shanghai Yamatake Jinshan Control Instruments Co., Ltd. Yamatake (Thailand) Co., Ltd. Yamatake Philippines, Inc. PT. Yamatake Berca Indonesia Yamatake Controls Singapore Pte. Ltd. YCV Corporation Yamatake Industrial Systems Co.,Ltd. China China Thailand Philippines , Panel Cutout Specifications are subject to change without notice. VZimATAKE Yamatake Corporation -
OCR Scan
ELECTROMAGNETIC Yamatake NW14 Scans-007331 Yamatake Counter SS2-3680-0100 9809-Y/Y
Abstract: No. SS2-MCM100-0100 Electromagnetic calorimeter Model MCM10A OVERVIEW The Yamatake model , rate is measured by an electromagnetic magnetic flow meter having field proven Yamatake technologies , calculation is necessary. · The Yamatake model MCM10A has a calorie consumption calculation program. · It , The Yamatake model MCM10A accumulates the totalized values of calorie consumption for both cooling and heating modes. Precise cooling/heating cost measurement Yamatake electromagnetic flow meter Yamatake
Original
JIS10K yamatake magnetic flow meter magnetic flow meter Pt 100 sensor connection yamatake yamatake FL calorimeter sensor JIS20K ANSI150
Abstract: transmitter. Based on Yamatake's proven Smart Transmitter technologies, the model PTG offers improved , . -1- First issue: Jun. 2001 Rev.11: Jul. 2003 No. SS2-PTG300-0100 (Rev.11) Yamatake , seal with ferrule cap nut type) -2- Yamatake Corporation No. SS2-PTG300-0100 (Rev , . 400 ms -3- No. SS2-PTG300-0100 (Rev.11) Yamatake Corporation Operating limit (T: 110 C , resistance is required for communication with the SFC or the HART®. Communicator. -4- Yamatake Yamatake
Original
PTG71 TDCS3000 PTG71G SUS316L ptg72g PTG71B HART 275 ptg72 PTG72 3000X
Abstract: required, please contact Yamatake's sales representatives. Yamatake Building Systems Co., Ltd. bears no , capacitive film humidity sensing element (FP3 specially developed by Yamatake) which ensures highly accurate , unknown. · If you use a Yamatake cotnroller, no problem will occur. Multi-loop controller , appliances. 5 AB-5965 Specifications are subjects to change without notice. Yamatake Building Systems Co., Ltd. Yamatake Corporation International Business Division Totate International Bldg Yamatake
Original
HTY7033 temperature PT100 Yamatake pt100 PT100 double fp3 matsushita TY7033Z0P00 HTY7033T1P00 HTY7033/ TY7033
Abstract: flowmeter converter is a high-performance, and highly reliable flowmeter based on Yamatake's proven MagneW , with conventional detectors. Please talk to your Yamatake Corporation representative for details , .3) Yamatake Corporation APPLICATIONS FUNCTIONAL SPECIFICATIONS Pulp and Paper Type of protection , communication - 8.5 V) / 0.025 With HART communication Load resistance: 250 minimum -2- Yamatake , counter reaches the preset value. -3- No. SS2-MGG210-0100 (Rev.3) Yamatake Corporation Yamatake
Original
MGG14C Yamatake MGG14C Yamatake MagneW MGG14C Yamatake converter mgg14c Yamatake converter magnew 3000 plus
Abstract: Pulp & Paper applications based on Yamatake's proven MagneW 3000 flow measurement technologies. The , existing models and those of other suppliers. Please consult your Yamatake representative for details , -0100 (Rev.3) Yamatake Corporation Digital output range/load resistance For converter (Model MGH14C , temperature limits -25 to +50°C (-13 to +122°F) Ambient humidity limits 5 to 100% RH -2- Yamatake , (gallon), mG (milli-gallon) Mass unit lb (pound) -3- No. SS2-MGH200-0100 (Rev.3) Yamatake Yamatake
Original
MGH18F f 531 flow meter flange jpi 150 SOURCE IRIDIUM 192 din pn10 PN16 MGH18
Abstract: flowmeter detector is a high performance, highly reliable flowmeter developed with Yamatake's proven MagneW , existing models and those of other manufacturers. Please consult your Yamatake representative for details , conventional converters. Please consult your Yamatake representative for details. · Model MGG 18/19 are , . SS2-MGG200-0100 (Rev.7) Yamatake Corporation APPLICATIONS FUNCTIONAL SPECIFICATIONS Pulp and , , etc. Shipbuilding Gas Circulating water for air conditioning, etc. -2- Yamatake Yamatake
Original
MGG18 Yamatake, mgg18f mgg18f MGG18D MagneW mgg18f G3451 Flange DIN PN25 MGG19
Abstract: will be decided by Yamatake. *10) When changing measurement point of input / output characteristic , gland adaptor, make sure that a Yamatake-made certified explosionproof cable gland adaptor is used. The , First issue: Jun. 2001 Rev.4: May. 2003 No. SS2-SLX100-0100 (Rev.4) Yamatake Corporation , (specific gravity) 0-100% Yamatake Corporation No. SS2-SLX100-0100 (Rev.4) FUNCTIONAL , standard If a range beyond those listed here is required, please consult with a Yamatake sales Yamatake
Original
S45C NUT Yamatake float transmitter Y131 SCS13A SLX110 liquid level indicator instruments
Abstract: . 1999 Rev.4: Oct. 2003 No. SS2-ATT100-0100 (Rev.4) Yamatake Corporation FUNCTIONAL , surge:1000 A -2- Yamatake Corporation No. SS2-ATT100-0100 (Rev.4) PHYSICAL SPECIFICATIONS , The Flameproof characteristics are guaranteed only when the supplied Yamatake explosion-proof packing , -0100 (Rev.4) Yamatake Corporation MODEL SELECTION ThermoPLUS Advanced Temperature Transmitter Field , H Calibration test report T -4- Yamatake Corporation No. SS2-ATT100-0100 (Rev Yamatake
Original
ASTM E230 C1602 LCD pt100 sensor JIS C1604 range M type A pt100 jis rtd pt100 sensor JIS C1604 ATT60 ATT60/70 ATT60/ SFC000010000P ATT70
Abstract: Vortex Flowmeter 0x8800 / 05,01 MagneW Yamatake MagneW V1.0-FF 0x0001 / 02,02 Yamatake MagneW 2W Yamatake MagneW 2W V1.0-FF 0x0c01 / 01,02 Yokogawa ADMAG AE Electromagnetic , Yokogawa DYF V1.0-FF 0x0006 / 01,02 ROTAMASS Gateway Rosemount 8800 V1.1-FF Yamatake , Yamatake AVPx03 V1.0-FF 0x0203 / 01,01 Yamatake AVPx03 V2.0-FF 0x0203 / 02,01 AVP204/AVP304 (SVP3000 Series) Yokogawa Westlock Intellis ICoT V2.0-FF AVPx03 V1 AVPx03 V2 Yamatake ABB Automation
Original
krohne ifc 090 Endress Hauser biffi actuator honeywell st3000 Yamatake honeywell honeywell CM42 TB82EC TB82PH TB82TC TB82TE 2PAA103000
Abstract: , which the processor unit converts into the sensor signal. This sensor can be used with Yamatake's , setting 1 Yamatake's Direct Digital Control unit IDC/M10 Safety Instructions Please read , where reliability or control accuracy is particularly required, please contact Yamatake's sales representatives. Yamatake Building Systems Co., Ltd. bears no responsibility for any benefit, or lack of benefit , subjects to change without notice. Yamatake Building Systems Co., Ltd. Yamatake Corporation Yamatake
Original
TY4700A TY4700A1004 TY4700A1012 HAND DRYER CIRCUIT DIAGRAM Yamatake DDC Yamatake pt3k Building Management System AB-5013A
Abstract: of Yamatake's Model ATT sensor are highly recommended. Combination of ATT71 temperature , Communicator (Sold separately) -1- First issue: Jul. 2002 No. SS2-ATT110-0100 Yamatake Corporation , DC) -2- Yamatake Corporation No. SS2-ATT110-0100 Table 2 Conversion accuracy Type of , resistance characteristics -3- No. SS2-ATT110-0100 Yamatake Corporation Example of accuracy , accuracy is 1.5/200 × 100 = 0.75% F.S.) Yamatake Corporation No. SS2-ATT110-0100 Explanation of Yamatake
Original
3 wire pt100 sensor wiring diagram Pt100 3 wire yamatake yamatake Sfc jPT100 pt100 JIS C1604-81 Yamatake level transmitter ATT61/71 ATT90 ATT92 SS2-ATT900-0100
Abstract: high performance and highly reliable flowmeter developed with Yamatake's proven MagneW 3000 flow , . Please consult your Yamatake representative for details. Type of protection · Model MGG 17 are , converters can be used in combination with our conventional converters. Please consult your Yamatake , : Feb. 1997 Rev.2: Jun. 2003 No. SS2-MGG200-0200 (Rev.2) Yamatake Corporation APPLICATIONS , model MGG14C converter 3 uS/cm or more -2- 160 C (320 F) Yamatake Corporation No Yamatake
Original
SS400 bolt nuts JPI150 MGG17D MGG17F SCS13 MagneW MGG17 SUS316
Abstract: issue: Jul. 2002 No. SS2-ATT900-0100 Yamatake Corporation SPECIFICATIONS Sheathed , . -2- Yamatake Corporation No. SS2-ATT900-0100 ASTM E230-1996 Class Class Class , . Consult with a Yamatake representative if the length is to be over 1 meter. Table 8 Thermoelectric motive , integrated test with model ATT61/71 temperature transmitter . -3- No. SS2-ATT900-0100 Yamatake , (°C) regardless of the - or + symbol. Pt100(R100/R0=1.3851) -4- Yamatake Corporation No Yamatake
Original
pt100 temperature sensor schematic Hoskins2300 PT100 WIRING SCHEMATIC thermoelectric pt100 thermo couple PT100 C1605-1995
Abstract: First issue: Jul. 2002 No. SS2-ATT910-0100 Yamatake Corporation Standard specifications of , Screwed Shape 38.4×3.9 32×37 Hex ATT97 28 Welded ØH ATT94 34 -2- Yamatake , ) Note) Handled as custom order. -3- No. SS2-ATT910-0100 Yamatake Corporation Surface , Protecting Well Hard facing (SF-6 thermal spray) Flange Yamatake Corporation No. SS2-ATT910 , . SS2-ATT910-0100 Yamatake Corporation Inspection standards Visual inspections The unit is visually Yamatake
Original
ATT91 NCF600 SUS310S SUH446 JIS blind flange B0405 STPG370 JIS blind flange TABLE 11 ATT98 ATT95 SUS304
Abstract: . 9 01 8 01 7 01 6 01 5 01 4 01 3 01 2 01 H as Yamatake Corporation rnsftrn specifications , . H as Yamatake Corporation specifications ISPECIFICATIONS CATALOG LISTING HPX-NT1 HPX-NT2 , NAME photoelectric switch NO. AD42433E KSrev 01 Yamatake Corporation â'¢â¡BfcttS , D-SW Yamatake Corporation IN MODE SELLECTION STATUS MODE INDICATION : RUN BLINKING A PUSH D-SW 3s , Yamatake Corporation * DETECTION FUNCTION SETTING IN MODE SELLECTION STATUS MODE INDICATOR : SET BLINKING -
OCR Scan
Yamatake HPX T1 HPX-nt1 Yamatake hpx yamatake HPX-NT2 Yamatake HPX V1 yamatake hpx series JE001-2043
Abstract: . SS2-STJ600-0100 (Rev.6) Yamatake Corporation APPLICATION NEPSI Flameproof approval Ex d II T6 (with , general purpose models) -2- Yamatake Corporation No. SS2-STJ600-0100 (Rev.6) Output Analog , , minimum voltage of 18.0V is required. -3- No. SS2-STJ600-0100 (Rev.6) Yamatake Corporation , meter body cover) Carbon steel (SNB7), SUS304, SUS630 Yamatake Corporation No. SS2-STJ600 , level 10cm or more Lower liquid level -5- No. SS2-STJ600-0100 (Rev.6) Yamatake Corporation Yamatake
Original
ST3000 PED Engineering STH940 STH960 Yamatake ST3000 smart transmitter JIS30K JIS10K 80a flange STH920/STH940/STH960/STH980 G11/2
Abstract: Foundation. -1- First issue: Apr. 1999 Rev.5: Oct. 2003 No. SS2-STJ400-0100 (Rev.5) Yamatake , H Bolt/nut material SNB7: -10°C SUS630: -6°C -2- Yamatake Corporation No. SS2-STJ400 , ten stages -3- No. SS2-STJ400-0100 (Rev.5) Yamatake Corporation OPTIONAL SPECIFICATIONS , specified. -4- Yamatake Corporation No. SS2-STJ400-0100 (Rev.5) PERFORMANCE SPECIFICATIONS , .5) Yamatake Corporation Model STG940 (Material of wetted parts: Diaphragm; Hastelloy C, Tantalum, SUS316L Yamatake
Original
STG960 scs14a equivalent Yamatake Pressure Transmitter STG 940 SF440A material SCS14A STG981
Abstract: First issue: Aug. 2000 Rev.1: Jan. 2004 No. SS2-MGN200-0100 (Rev.1) Yamatake Corporation , - = 0.113 m 1.84 × 2 × 3600 1.84 × W × 3600 -2- Yamatake Corporation No. SS2-MGN200 , (92 to 111) 207 (198 to 215) H5 -3- No. SS2-MGN200-0100 (Rev.1) Yamatake Corporation , provided with a cable (10 m). Figure 5 Terminal connections -4- Yamatake Corporation No , .1) Yamatake Corporation DIMENSIONS Bell mouth type 130 80 X-hole, N-each t H W D P1 Yamatake
Original
BELL MOUTH clearance calculation water level control BELL MOUTH MagneW3000 flowmeter electromagnetic flowmeter NNK140/941 W3000
Abstract: subject to change without notice. -1- Rev.10: Aug. 2002 No. SS2-5220-1100 (Rev.10) Yamatake , fill Fluorine oil (specific gravity: 1.915 at 25°C) -2- Yamatake Corporation No. SS2 , . SS2-5220-1100 (Rev.10) Yamatake Corporation MODEL SELECTION Basic model no. Cover material , ) Note) When ordering "Y" options, please write as: KDP22Y-2222A 1-5, 7 (Y -4- ) Yamatake , specification Note) For any combination of two or more Y-specification items, please consult your Yamatake Yamatake
Original
PREX3000 KDP11 KDP22 OM2-5220-0000 OM2-5220-1100 SF45A yamatake kdp22 mmH2O KDP22Y KDP11/22 ID2-5220-0020
Showing first 20 results.