500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Top Results

Part Manufacturer Description Datasheet BUY
PMP2278 Texas Instruments Buck (18V@3A) for X-ray Detectors visit Texas Instruments
AFE0256GBTD Texas Instruments 256-Channel Analog Front-End for Flat-Panel Digital X-ray Detector 0- 0 to 85 visit Texas Instruments
AFE1256GBTD Texas Instruments 256-Channel Analog Front-End for Flat-Panel Digital X-ray Detector 0- 0 to 85 visit Texas Instruments
AFE0064IPBKR Texas Instruments 64 Channel Analog Front End for Digital X-Ray Detector 128-LQFP -40 to 85 visit Texas Instruments
AFE1256TDS Texas Instruments 256-Channel Analog Front-End for Flat-Panel Digital X-ray Detector 314-COF 0 to 85 visit Texas Instruments
AFE2256TDU Texas Instruments 256-Channel Analog Front End (AFE) for Digital X-Ray, Flat-Panel Detectors 320-COF 0 to 85 visit Texas Instruments

X-RAY thickness

Catalog Datasheet MFG & Type PDF Document Tags

1kva inverter circuit diagram

Abstract: toshiba tosgage 7511 TOSGAGE -7511 TOSGAGE Series X-ray Thickness Gage General The X-ray thickness gage is used to measure the thickness of a strip continuously without contacting that strip. This gage uses the fact that the amount of radiation that passes through the strip varies with the thickness of that , . Figure 1 X-ray Thickness Gage TOSGAGE-7511 · A newly-developed X-ray generator is used, providing , Calibration Curve The X-ray generator, detector and other electrical circuits on the X-ray thickness gage
Toshiba
Original

220V Automatic Voltage Regulator schematic

Abstract: 2kva inverter circuit diagram TOSGAGE Series X-ray Thickness Gage TOSGAGE -7515 General · The operation-PC uses Windows® NT, and is a user-friendly PC. The X-ray thickness gage is used to measure the thickness of , Calibration Curve The X-ray generator, detector and other electrical circuits on the X-ray thickness gage , radiation that passes through the strip varies with the thickness of that strip. · A newly-developed , . The TOSGAGE-7515 focuses X-ray beams finely in the strip width direction to improve thickness
Toshiba
Original

1kva inverter circuit diagram

Abstract: 2kva inverter circuit diagram TOSGAGE Series X-ray Thickness Gage General The X-ray thickness gage is used to measure the thickness of a strip continuously without contacting that strip. This gage uses the fact that the amount of radiation that passes through the strip varies with the thickness of that strip. The TOSGAGE-7525 is a high quality thickness gage for cold rolling achieving outstanding safety, operability , , detector and other electrical circuits on the X-ray thickness gage are subject to drift as time passes
Toshiba
Original

circuit diagram blood gas analyzer

Abstract: Light Detector laser Structure Availability in dimension Scintillator effective area Substrate Scintillator (mm) Thickness Thickness (µm) (mm) Max. Min. Amorphous-Carbon 440 × 440 Plate with (17" × 17") Csl , Thickness type A (mm) (mm) (mm) Csl (Tl) 30.5 × 21 27 × 17 3 Csl (Tl) 50 × 10 47 à , ) 26.5 23.5 3 CsI Relative light Thickness output B (µm) (% Typ.) 150 70 150 40 150 , and scintillator thickness. CTF C (% Typ.) 18 E 33 E 18 E 33 E 18 E 33 E 18 E 33 E 18 E
Hamamatsu
Original
Abstract: Structure Availability in dimension Scintillator effective area Substrate Scintillator (mm) Thickness Thickness (µm) (mm) Max. Min. Amorphous-Carbon 440 × 440 Plate with (17" × 17") Csl Scintillator , ALS J8978 J9857 Substrate Scintillator Outer dimension Effective area Thickness type A (mm , CsI Relative light Thickness output B (% Typ.) (µm) 150 70 150 40 150 70 150 40 150 70 , thickness. CTF C (% Typ.) 18 E 33 E 18 E 33 E 18 E 33 E 18 E 33 E 18 E 33 E Type D HL Hamamatsu Photonics
Original
D-82211 SE-171-41 TMCP1031E04

scintillator

Abstract: lanex-R resistance, PL Abstract Reliable metrology data such as layer thickness and composition measured by X-ray , theoretical model, the compositions and thickness of the layers in a pHEMT epi wafer can be determined. For , , In composition, InGaAs channel thickness and Cap layer thickness. The %R&R contributions for Al composition, In composition, InGaAs channel thickness and cap layer thickness were 22.3, 10.8, 26.2, and 4.0 , increase in the Cap thickness %R&R to be due to sample selection, i.e. for these new samples the Al
Hamamatsu Photonics
Original
scintillator lanex-R mammography csi fop ZL99801885 lanex
Abstract: stencil design of the SPM 7 series. To ensure reliable solder joints, 150 µm thickness is generally recommended. The thickness of stencil determines the amount of solder in combination with the opening width , ‰ 38% Note: 1. Square without Via Holes Thickness of stencil is 100 µm. Thickness and Opening Width of Stencil To determine the appropriate pattern of the stencil, several thickness and , µm thickness and 200 µm opening width are preferred; as shown in Table 10 in comparison with Table Skyworks Solutions
Original

Senju M705-GRN360-K2-V

Abstract: Senju M705-GRN360-K2-V solder paste built-in X-ray image intensifier having an extremely thin aluminum input window. Its thickness is only , down to several keV which penetrate plastic (PET) materials. C7716 Series Input window thickness , 0.3mmt Current Model 0.5mmt 1.0mmt 10.0 Input window thickness 1.0mm 1.0 0.1 0 , difference in the dial plate thickness (number â'3â') can be verified. v Wristwatch X-ray tube
Fairchild Semiconductor
Original
Senju M705-GRN360-K2-V Senju M705-GRN360-K2-V solder paste Senju M705-GRN360-K2-V datasheet AN-9078 LFM-48W M705-GRN360-K2-V FSB70625 FSB70250 FSB70450
Abstract: built-in X-ray image intensifier having an extremely thin aluminum input window. Its thickness is only , different Al film thicknesses C7716 Series Input window thickness LPlastic bottle with cap 0.3 mm , TRANSMITTANCE (%) 0.3 mmt Current Model 0.5 mmt 1.0 mmt 10.0 Input window thickness 1.0 mm , Even a very slight difference in the dial plate thickness (number "3") can be verified. L Hamamatsu Photonics
Original
C7716-10 B0091EA 1043E04

x-ray tube

Abstract: intensifier size, stencil thickness, and aspect ratio are described in the following table: Table 2 Version Aperture shape Aperture opening Stencil thickness (mil) CA Rectangle CA Rectangle , Design Comp Type Profile Stencil Thickness CA POLARPAK RSS 5 mils Aperture , aperture opening / stencil thickness) is 2.5 · The minimum acceptable area ratio (LxW / 2(L+W)T) is 0.8 , Material: FR-4 Thickness: 3.175 mm [0.125 in.] Number of copper (Cu) layers: 16 Nominal outer layer
Hamamatsu
Original
x-ray tube intensifier microfocus x-ray Image intensifier tube CCD MARKING x-ray view box 1043E05

73494

Abstract: NXR-1400 affordable and readily available shield for some applications, but requires significant thickness to be effective. Copper likewise can shield much of the radiation but needs a greater thickness than zinc. Table , Application Note 1533 Aluminum would need to be fairly thick for filtering, requiring about 4x the thickness of copper for the same drift reduction. Since the filtering is proportional to thickness, an 8.5mm aluminum sheet would limit drift to about 88µV (10x thickness for 10x reduction) at the same exposure
Vishay Siliconix
Original
AN611 IPC-9701 73494 NXR-1400 ekra e5 ekra nicolet nxr1400 tamura solder paste SMD125T16L

"x-ray machine"

Abstract: RAD-60 TUBE Parameter X-ray Tube X-ray Tube Cooling Method X-ray Tube Window Material / Thickness Target , having an extremely thin aluminum input window. Its thickness is only 0.3mm or less, virtually at the
Intersil
Original
RAD-60 luggage security system RADOS dosimeter AN1533

x-ray tube

Abstract: X-RAY thickness / Thickness Target Material High Voltage Power Supply Power Consumption (Max.) Input Voltage Operating , intensifier having an extremely thin aluminum input window. Its thickness is only 0.3mm or less, virtually at
Hamamatsu Photonics
Original
L9631 X-RAY thickness t6.3a 250v X-RAY INSPECTION x-ray tube datasheet rs tube RS-232C TLSO1053E05

HAMAMATSU L9181

Abstract: L9181-02 / Source Head Shield cover Survey meter Thickness(mm) 0.22 1.3 1.74 Soft X-ray emitted area , SHIELDING EFFECT (%) 100 80 60 40 20 0 0.001 0.01 0.1 1 10 100 THICKNESS , 30 19.5 Shield material thickness 8 Shield material SUS 304 Aluminum plate Glass plate , HOLES DEPTH: 8 mm 86 7 1/4-20 UNC* TAPPA0082EC Thickness (mm) 0.22 1.3 1.74 , 1.0 s 1.5 s 2.0 s Shield material thickness Shield material SUS 304 Aluminum plate Acrylic
Hamamatsu Photonics
Original
L9181-02 IEC61326 HAMAMATSU L9181 x-ray tube L9181 L9181 x-ray TLSO1061E01
Abstract: TUBE UNIT Parameter X-ray Tube X-ray Tube Cooling Method X-ray Tube Window Material / Thickness , intensifier having an extremely thin aluminum input window. Its thickness is only 0.3mm or less, virtually at Hamamatsu Photonics
Original
TAPP1073E02

x-ray tube

Abstract: x-ray tube datasheet Material / Thickness Target Material Tube Voltage Operational Range Tube Current Operational Range 2 , thin aluminum input window. Its thickness is only 0.3mm or less, virtually at the limit of present
Hamamatsu Photonics
Original
L8121-03 IEC61326-1 IEC61010-1 x-ray tube operation l8121 IEC-61326-1 TLSO1057E03

L9421-02

Abstract: L9421 Parameter X-ray Tube X-ray Tube Cooling Method X-ray Tube Window Material / Thickness Target Material , . Its thickness is only 0.3mm or less, virtually at the limit of present technology providing excellent
Hamamatsu Photonics
Original
L9421-02 L9421 sharp ccd C7876-10 H8480 H8953 TLSO1055E03

x-ray tube

Abstract: TLSOB0102EA Parameter X-ray Tube X-ray Tube Cooling Method X-ray Tube Window Material / Thickness Target Material , from a built-in X-ray image intensifier having an extremely thin aluminum input window. Its thickness
Hamamatsu Photonics
Original
L10321 TLSOB0102EA xray TLSOF0185 TLSO1058E03

x-ray tube

Abstract: x-ray tube datasheet , etc. Object By adopting a thin sensor head with a thickness of only 50 mm, installation inside a , dimensional outline. FEATURES Connection to a computer is possible. Only 50 mm in thickness By adopting a line sensor as a detector, the thickness of the sensor head is reduced to a maximum of 50 mm
Hamamatsu Photonics
Original
L10101 50 kv TLSO1062E04
Showing first 20 results.