NEW DATABASE - 350 MILLION DATASHEETS FROM 8500 MANUFACTURERS
VTL5C1, 5C2 PACKAGE DIMENSIONS inch (mm) PLASTIC POTTING CONTOUR NOT CONTROLLED - Datasheet Archive
VTL5C1, 5C2 PACKAGE DIMENSIONS inch (mm) PLASTIC POTTING CONTOUR NOT CONTROLLED DESCRIPTION VTL5C1 offers 100db dynamic range,
Low Cost Axial Vactrols VTL5C1, 5C2 PACKAGE DIMENSIONS inch (mm) PLASTIC POTTING CONTOUR NOT CONTROLLED DESCRIPTION VTL5C1 offers 100db dynamic range, fast response time, and very high dark resistance. VTL5C2 features a very steep slope, low temperature coefficient of resistance, and a small light history memory. ABSOLUTE MAXIMUM RATINGS @ 25°C LED Forward Voltage Drop @ 20 mA: Maximum Temperatures Storage and Operating: Cell Power: Derate above 30°C: LED Current: Derate above 30°C: 40°C to 75°C 175 mW 3.9 mW/°C 40 mA 1 0.9 mA/°C LED Reverse Breakdown Voltage: 3.0 V 2.0V (1.65V Typ.) Min. Isolation Voltage @ 70% Rel. Humidity: 2500 VRMS Output Cell Capacitance: 5.0 pF Cell Voltage: 100V (VTL5C1), 200V (VTL5C2) 0.5 pF Input - Output Coupling Capacitance: ELECTRO-OPTICAL CHARCTERISTICS @ 25°C ON Resistance 2 Part Number Material Type VTL5C1 VTL5C2 OFF 3 Resistance @ 10 sec. (Min.) Response Time 4 Slope (Typ.) Dynamic Range (Typ.) @ 0.5 mA -R@ 5 mA R DARK -R@ 20 mA Turn-on to 63% Final RON (Typ.) Turn-off (Decay) to 100 k (Max.) Input current Dark Adapted (Typ.) 1 1 mA 10 mA 40 mA 20 k 600 200 50 M 15 100 db 2.5 ms 35 ms 0 1 mA 10 mA 40 mA 5.5 k 800 200 1 M 24 69 db 3.5 ms 500 ms Refer to Specification Notes, page 41. PerkinElmer Optoelectronics, 10900 Page Ave., St. Louis, MO 63132 USA Phone: 314-423-4900 Fax: 314-423-3956 Web: www.perkinelmer.com/opto 43 Typical Performance Curves Output Resistance vs. Input Current VTL5C1 Response Time VTL5C1 Output Resistance vs. Input Current VTL5C2 Response Time VTL5C2 Input Characteristics Notes: 1. At 1.0 mA and below, units may have substantially higher resistance than shown in the typical curves. Consult factory if closely controlled characteristics are required at low input currents. 2. Output resistance vs input current transfer curves are given for the following light adapt conditions: (1) (2) (3) (4) 3. PerkinElmer Optoelectronics, 10900 Page Ave., St. Louis, MO 63132 USA 25°C - 24 hours @ no input 25°C - 24 hours @ 40 mA input +50°C - 24 hours @ 40 mA input 20°C - 24 hours @ 40 mA input Response time characteristics are based upon test following adapt condition (2) above. Phone: 314-423-4900 Fax: 314-423-3956 Web: www.perkinelmer.com/opto 44