NEW DATABASE - 350 MILLION DATASHEETS FROM 8500 MANUFACTURERS
VPF-S300 EN61000-3-2 VPF-S300-12 VPF-S300-18 VPF-S300-24 VPF-S300-36 - Datasheet Archive
VPF-S300 Switching Power Supply Rev. 12-2006 Features ·Universal AC Input / Full Range ·Remote Sense & Remote
1/5 VPF-S300 VPF-S300 Switching Power Supply Rev. 12-2006 Features ·Universal AC Input / Full Range ·Remote Sense & Remote On/Off ·High power density: 7.15 watts/inch3 ·Power factor corrected to EN61000-3-2 EN61000-3-2 class D ·Approved to UL/CUL/TUV/CB/CE & Class B Emissions ·U-Chassis ·Protections: short circuit/overload/over voltage/over temp ·Extended temperature range: -40 ~ +75 ºC available Preset Model VPF-S300-12 VPF-S300-12 VPF-S300-18 VPF-S300-18 VPF-S300-24 VPF-S300-24 VPF-S300-36 VPF-S300-36 VPF-S300-48 VPF-S300-48 Voltage 12V 18V 24V 36V 48V Ripple & Noise 5, Output Current Output 1, 12 - 15 16 - 21 22 - 30 31 - 41 42 - 55 2, 3 V V V V V Minimum 0A 0A 0A 0A 0A Maximum 4 25 A 18.75 A 13.64 A 9.68 A 7.15 A Regulation +/- 1% +/- 1% +/- 1% +/- 1% +/- 1% 6 (Vpp) 1% 1% 1% 1% 1% Max Power 7 300 W 300 W 300 W 300 W 300 W Notes: 1 Customer must specify output voltage. 2 Output is fully isolated. 3 Output voltage is measured at output power connector. 4 O u t p u t c u r r e n t l i m i t e d b y m a x . p o w e r. 5 1 % M i n u m u m l o a d i s r e q u i r e d t o m a i n ta i n t h e r i p p l e a n d r e g u l a t i o n . 6 Ripple and noise is measured from 10KHz to 20 MHz at output terminals with a 0.1 µF ceramic c a pa c i t o r a n d a 2 2 µ F e l e c t r o l y t i c c a pa c i t o r i n pa r a l l e l . 7 M u s t u s e 2 2 C F M t o a c h i e v e m a x . p o w e r. V-Infinity, LLC, 20050 SW 112th Ave., Tualatin, OR 97062 www.v-infinity.com 1-866-372-1258 2/5 VPF-S300 VPF-S300 Switching Power Supply Rev. 12-2006 Input Parameter Input Frequency Input Voltage Input Current Inrush Current Power Factor Conditions/Description Min 47 90 Nom Max 63 264 5 35 Units Hz VAC Amps Amps Min Nom Max Units At 90 VAC full load Peak measured at 230 VAC and full load, cold start Active power factor correction meets EN61000-3-2 EN61000-3-2 class D Output Parameter Conditions/Description Transient Response Output voltage returns to within 1% in less than 2.5 mS for a 50% load change. Peak Overshoot Efficiency Turn on delay Hold up time Adjustability Remote sense Remote inhibit LED display (LED 1) Power Good transient does not exceed 5% Turn-on and turn-off overshoot shall not exceed 5% over nominal voltage. At 230 V and full load 80% At 120 VAC 1 second At 120 VAC and 80% of rated maximum load 20 mS Output user adjustable +/- 5% Designated as RS+ and RS- on the CN3. Total voltage compensation for cable losses with respect to the main output. Defined RSW on CN3, requiring a TTL low signal to inhibit output Green - the power supply is operating normally. Orange - when any protection occurs or RSW is low. Designated as PG on the CN3. This signal goes high 100-500 mS after the output reaches regulation. It goes low at least 1 mS before loss of regulation. Protection Circuit Parameter Input fuse Input-voltage Overload Short circuit Output overvoltage Over temp. Conditions/Description Built-in ac fuse. A blown fuse usually indicates permanent damage to the power supply serviceable by factory only. Power supply shuts down when ac input is under 80 +/- 5 VAC. When ac line reappears over 86 +/- 5 VAC, the power supply restarts automatically. Current limiting starts at 110-140% of the rated output current and recovers automatically. Short circuit can be continuous. Recovers automatically upon removal of short. Output is protected against overvoltage. Unit shuts downa and latches when voltage at output terminals exceeds 130%. AC input needs to be reset to restart the powers supply. Power supply shuts down when temperature is in excess of 85 ºC. Auto recovery. V-Infinity, LLC, 20050 SW 112th Ave., Tualatin, OR 97062 www.v-infinity.com 1-866-372-1258 3/5 VPF-S300 VPF-S300 Switching Power Supply Rev. 12-2006 General and Safety Parameter Operating temp. Optional operating Storage temp. Optional storage temp. Operating humid. Storage humid. Conditions/Description Derates linearly from 100% load at 50 ºC to 50% load at 70 ºC. Derates linearly from 100% load at 50 ºC to 37.5% load at 75 ºC. Max 50 Units ºC -40 75 ºC -20 -40 Non-condensing Non-condensing Min 0 Nom 85 85 ºC ºC 5% 5% 90% 95% RH RH EMI Safety FCC Part 15, CISPR 22 class B, Conducted. Approved to UL60950-1 UL60950-1, CSA C22.2 No.60950-1-03, TUV EN60950-1 EN60950-1, CE Mark (LVD) EN61000-3-2 EN61000-3-2,3 and IEC61000-4 IEC61000-4 Series Regulations and CB. Leakage Current at 264 VAC 3.5 mA Isolation Voltage Applied for 3 seconds (HI-POT) Primary to secondary: 3000 VAC Primary to transformer core: 1500 VAC Primary to earth ground: 1500 VAC Grounding Test Allowable resistance measured when 25 A current is 0.1 Ohm applied from the ground pin of the three prong plug to the farthest earthed connection point. Warranty Standard warranty length 2 years MTBF According to MIL-HBK-217 MIL-HBK-217 at 30 ºC 100,000 hours Burn-in Full load, at 45 +/- 5 ºC, 230 VAC. Burn-in for 1 8 hour up to 8 hours in early productions. Time reduced gradually as product matures. Note : Customer must specify extended temperature on PO. Mechanical Parameter Weight Enclosure Mounting screws Conditions/Description Min Nom 7(L) x 4(W) x 2(H) Two sets of 8 threaded mounting holes available on the enclosure B: 6-32, maximum insertion depth of 0.2 inches. C: M4, maximum insertion depth of 0.2 inches. Max 950 Units grams inches Input Connector - (CN1) Parameter AC input (Option 1) AC Input (Option 2) Conditions/Description Molex Part No. 26-48-1201 or similar (5 pin). Suggested mating plug: Molex Part No. 09-91-0500 or equivalent (5 pin, 3 used) DINKLE Terminal block Part No. DT-35-A02W-03 DT-35-A02W-03 (3 pin, M3 Screw) 8.25mm spacing Suggested mating connector: Molex 19198-0016 or similar V-Infinity, LLC, 20050 SW 112th Ave., Tualatin, OR 97062 www.v-infinity.com 1-866-372-1258 4/5 VPF-S300 VPF-S300 Switching Power Supply Rev. 12-2006 Output Connector - (CN2) Parameter Output (Option 1) Conditions/Description Molex Part No. 09-91-2000 or similar. (14 pin) Output pin assignment, VO+ (Pins 1-7), VO- (Pins 8-14) Suggested mating connector: Molex 14 pin (part No. 09-91-1400) Output (Option 2) Howder Terminal block Part No. HD-121-8P HD-121-8P (8 pin, M3.5 Screw) 9.5mm spacing Output pin assignment, VO+ (Pins 1-3), VO- (Pins 4-6) Suggested mating connector: Molex 19198-0045 or similar. Note: Output connector needs to be specified on the PO. Logic Connector - (CN3) Parameter Logic Pin Assignments: Fan Conditions/Description JS B5B-XH-A Suggested mating connector: JST XHP-5 or equivalent , Contact: SXH-002T-P0 SXH-002T-P0.6. 1. PG 2. INH 3. RTN 4. VIS5. VIS+ JST B2B-XH-A Suggested mating connector: JST XHP-2 or equivalent, Contact: SXH-001T-P0 SXH-001T-P0.6. V-Infinity, LLC, 20050 SW 112th Ave., Tualatin, OR 97062 www.v-infinity.com 1-866-372-1258 5/5 VPF-S300 VPF-S300 Switching Power Supply Rev. 12-2006 INPUT IN Neu r l t tra Neu a Li e Lin n GN D VO+ VOVO VO+ VOVO OUTP OUTPUT M4 M4 V-Infinity, LLC, 20050 SW 112th Ave., Tualatin, OR 97062 www.v-infinity.com 1-866-372-1258