500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Top Results

Part Manufacturer Description Datasheet BUY
ISL32741EIBZ-T Intersil Corporation PROFIBUS Compliant 6kV VDE-Reinforced Isolated RS-485 Transceiver; SOIC16; Temp Range: See Datasheet visit Intersil
ISL32741EFBZ-T Intersil Corporation PROFIBUS Compliant 6kV VDE-Reinforced Isolated RS-485 Transceiver; SOIC16; Temp Range: See Datasheet visit Intersil
ISL32741EIBZ Intersil Corporation PROFIBUS Compliant 6kV VDE-Reinforced Isolated RS-485 Transceiver; SOIC16; Temp Range: See Datasheet visit Intersil
ISL32741EFBZ-T7A Intersil Corporation PROFIBUS Compliant 6kV VDE-Reinforced Isolated RS-485 Transceiver; SOIC16; Temp Range: See Datasheet visit Intersil
ISL32741EFBZ Intersil Corporation PROFIBUS Compliant 6kV VDE-Reinforced Isolated RS-485 Transceiver; SOIC16; Temp Range: See Datasheet visit Intersil
ISL32741EIBZ-T7A Intersil Corporation PROFIBUS Compliant 6kV VDE-Reinforced Isolated RS-485 Transceiver; SOIC16; Temp Range: See Datasheet visit Intersil

VDE 0570/EN 61558

Catalog Datasheet MFG & Type PDF Document Tags

DIN 34

Abstract: 230V -15V TRANSFORMER : 24V 0 24V 5,21 A 5,21 A STEU 250/48 IP 00 ta 40"C 9 VDE 0570 / EN 61558 [$D5A ETA Typ 5700 , vorbereitet für Geräte der Schutzklasse I Prepared for class I equipment IP00 B (UL class 130) 40°C VDE 0570/EN 61558 Teil 1 mit Teil 2-2 und 2-4; UL 506; CSA 22.2 Part 1 with Part 2-2 and 2-4 US UL File
-
OCR Scan

hahn BV UI 30

Abstract: en 61558 UI 21 : 1,0 BA · ­ 1,0 · 70°C/B · · ENEC 05, KEMA KEUR, CSA UL · C · , · · · · , . . EN 61558. HAHN ­ UI 21, UI 30, UI 39, UI 48 1,0 60,0 . HAHN , . , , 6000 / . ( VDE 0570 CEE 15 3750 ). 10 . 70 °C/B EN 61558 CEE 15. UI 30 , ta 70 °C/B VDE 0570/ EN 61558 ­ 115 : 1 ­ 4 3 ­ 6 ­ 230 : 3 ­ 4 , BV
-
Original

VDE 0570/EN 61558

Abstract: D78609 TRAFO SPK 006. Baugrösse / Size : EI 20 / 10 D 78609 TUNINGEN/GERM. 0,6 22,0 15,0 ±0.5 24,0±0,5 Potted under Vacuum Prüfzeichen: ±0,3 Split Bobin Vakuumvergossen 5,0 ±0.5 5,0 Short Circuit Proof Zweikammer Wicklung ±0,5 Kurzschlussfest 19 S P I T Z NAG E L 0,5 VA Nennleistung Power Rating Approvals: VDE 0570, EN 61558 UL - , D78609 Tuningen / Germany VDE UL CSA CE 1585 ja ja ja ja ja ja ja ja ja ja ja
-
Original
VDE 0570/EN 61558 50-60H

VDE 0570/EN 61558

Abstract: TRAFO SPK TRAFO SPK 030. 2,5 VA Nennleistung Power Rating Baugrösse / Size : EI 30 / 15,5 nicht Kurzschlussfest Zweikammer Wicklung Potted under Vacuum Prüfzeichen: 27,0 D 78609 TUNINGEN/GERM. Split Bobin Vakuumvergossen ± 0,5 S P I T Z NAG E L Short Circuit Proof Approvals: VDE 0570 EN 61558, UL 506, UL1585 Class 2 und ±0,5 "A" 3,5 Class 3, ( File E108 750 , 30E D78609 Tuningen / Germany VDE UL CSA CE 1585 ja ja ja ja ja ja ja ja ja
-
Original
TRAFO SPK E108 spitznagel 78609 78609 spitznagel

SPITZNAGEL D 78609 003

Abstract: D78609 TRAFO SPK 003. Baugrösse / Size : EI 20 / 7 D 78609 TUNINGEN/GERM. 0,6 22,0 15,0 ±0.5 24,0±0,5 Potted under Vacuum Prüfzeichen: ±0,3 Split Bobin Vakuumvergossen 5,0 ±0.5 5,0 Short Circuit Proof Zweikammer Wicklung ±0,5 Kurzschlussfest 15 S P I T Z NAG E L 0,35 VA Nennleistung Power Rating Approvals: VDE 0570, EN 61558 UL - , 20B D78609 Tuningen / Germany VDE UL CSA CE 1585 ja ja ja ja ja ja ja ja ja
-
Original
SPITZNAGEL D 78609 003 D-78609 D 78609 SPITZNAGEL D 78609 spitznagel 78609 trafo spk Trafo datasheets

BV UI 21

Abstract: / 60 ­ ta 70 °C/B VDE 0570/ EN 61558 ­ 115 : 1 ­ 9 4 ­ 12 ­ 230 : 4 ­ 9
-
Original
BV UI 21

VDE 0570/EN 61558

Abstract: SPITZNAGEL D 78609 spk 031 TRAFO SPK 031. 3,0 VA Nennleistung Power Rating Baugrösse / Size : EI 30 / 18 nicht Kurzschlussfest Zweikammer Wicklung ± 0,5 Potted under Vacuum Prüfzeichen: 30,0 Split Bobin Vakuumvergossen S P I T Z NAG E L D 78609 TUNINGEN/GERM. not Short Circuit Proof Approvals: VDE 0570 EN 61558, UL 506, UL1585 Class 2 und ±0,5 Class 3, ( File E108 750 ), CSA "A" , 30B 30B 30B 30B 30B 30F 30F 30F D78609 Tuningen / Germany VDE UL CSA CE 1585
-
Original
SPITZNAGEL D 78609 spk 031 EI-30/18 VDE 0570 trafo 5 A

Trafo spk 060

Abstract: 060090 TRAFO SPK 060. 5,50 VA Nennleistung Power Rating Baugrösse / Size : EI 42 / 15 Zweikammer Wicklung 27,5 5,0 37,0 ±0,5 27,5 mm Potted under Vacuum Approvals: VDE 0570 EN 61558, UL 506, UL1585 Class 2 und ±0,5 3,5 0,9 44,0 Split Bobin Vakuumvergossen 33,0 D 78609 TUNINGEN/GERM. not Short Circuit Proof Prüfzeichen: S P I T Z NAG E L ±0 , 42D D78609 Tuningen / Germany VDE UL CSA CE 1585 ja ja ja ja ja ja ja ja ja
-
Original
Trafo spk 060 060090 spitznagel spk 060 0601515 UL-1585 Trafo

BV UI 21

Abstract: UI30 VDE 0570/ EN 61558 ­ 115 : 1 ­ 6 3 ­ 8 ­ 230 : 3 ­ 6 BV BV BV BV BV BV
-
Original
UI30 bv 304 BV UI bv ui 304

BV UI 396 0079

Abstract: ENEC-05 /15 8/15 8/15 8/15 .* .* .* .* .* * ­ : 1,2/10/14/18/24/30 ­ ta 70 °C/B VDE 0570/ EN 61558 ­ 115 : 1 ­ 8 3 ­ 10 ­ 230 : 3 ­ 8 BV BV BV BV BV BV UI
-
Original
BV UI 396 0079 ENEC-05 BV UI 396 0084 UI39

VDE 0570/EN 61558

Abstract: VDE 0570 - Description . : safety isolating transformer according to VDE 0570/EN , . according to VDE 0570/EN 61 558 -1 : 1997 with part 2-6 *according to VDE 0570/EN 61 558 -1 , . according to VDE 0570/EN 61 558 -1 : 1997 with part 2-6 *according to VDE 0570/EN 61 558 -1 , . according to VDE 0570/EN 61 558 -1 : 1997 with part 2-6 *according to VDE 0570/EN 61 558 -1 , . according to VDE 0570/EN 61 558 -1 : 1997 with part 2-6 *according to VDE 0570/EN 61 558 -1
BLOCK Transformatoren-Elektronik
Original
LS100 2X18 FL412 HV transformer specification transformer specification LS10 0570/EN FL52/5 FL52/6 FL52/8 FL52/9

transformer EN 61558

Abstract: iec 61558 nach IEC 61558, EN 61558, VDE 0570 zwischen Ein- und Ausgangsstromkreisen 3750 V, 50 Hz , ,0 4,0 1,5 2,5 dc power supply / safety isolating to IEC 61558, EN 61558, VDE 0570 between , Befestigung Verpackung : : : : £5 % Schraubklemmenanschluß Tragschienenmontage (DIN EN 50022 , vorbehalten : screw-type terminals : panel installation on mounting rails (DIN EN 50022) : individual in cardboard box Packaging Beschreibung ­ stabiles Kunstoffgehäuse für Tragschienenmontage (DIN EN 50022
-
Original
transformer EN 61558 iec 61558 en 61558 61558 IEC61558

0-9v 500ma transformer

Abstract: EI30 transformer VDE 0570/EN 61 558, UL 506, CSA 22.2 Mftrs. List No. 230V Primary (VBEI Series) 0.5VA - 0.25VA per , terminals Ì Manufactured to IEC 61558-2-13, DIN EN 61558-2-13, VDE 0570 part 2-13 Short circuit proof , secure board mounting Manufactured & tested to VDE 0570, EN61558, EN60950 Approvals to UL5085, cUL5085 3 , mounting possible Dual output can be connected in series or in parallel Constructed and tested to VDE 0570 , secondaries for series and parallel connection Ì Vacuum encapsulated to UL94V0 Ì EN 61-558 IEC 61-558 Ì UL
Element14 Catalog
Original
0-9v 500ma transformer EI30 transformer transformer 230v ac BABT CR 0090 SIM300 RoHS 230v to 6v step down transformer B66421U0250K187 B66421U0315K187 B66422W1010D001 B66422B2000X000 B66423GX187 B66424W1012D1

iec 61558

Abstract: Ford f 150 control Sicherheits- und Trenntransformator nach IEC 61558, EN 61558, VDE 0570 Prüfzeichen Prüfspannung UL, C-UL (Canada) zw isch en Eingangs- und Ausgansstrom kreisen m ind. 2500 V, 50 Hz in Ab , 61558, EN 61558, VDE 0570 UL, C-UL (Canada) betw een inp u t a n d o u tpu t circuit min. 2500 V, 50 H , ) Ausgangsspannung Anschlüsse Befestigung nach Tabelle CAGE CLAM P-A nschlußklem m en 4 m m 2 (g egenüberliegend ). B efestigung sm aße entsp rech en DIN 41308 B latt 2. Alte rn ativ sind die Typen mit K om b
-
OCR Scan
Ford f 150 STEU1600/23

41308

Abstract: iec 61558 Artikeldetail-kopf Information for: USTE, low inrush current control-, safety isolating- and isolating transformer STE/STU Approvals: Design Test voltage Frequency range Type Protection index Safety class Ambient temperature Cooling method Input voltage Input voltage range Output voltage Terminals Fixing means Description Low inrush universal current control-, safety isolating- and isolating transformer to IEC 61558, EN 61558, VDE 0570, UL 506 between input and output
-
Original
41308

batibus

Abstract: Transformer kaschke Trennspannung nach VDE 0570 (pr. EN 61558) wird in die Schnittstellen mit Benutzerzugang (Personenschutz , voltage according to VDE 0570 (pr. EN 61558) are realized in interfaces with user access (protection of , (+50%-30%) interface side 3750 500 * VDE Reg.-No. 5753 428 2(1) Prüfspannung Netz/Schnittstelle
Kaschke Components
Original
batibus Transformer kaschke

EI - 28 TRANSFORMER

Abstract: EI - 33 TRANSFORMER Sicherheitstransformator nach IEC 61558-2-6, DIN EN 61558-2-6, VDE 0570 Teil 2-6 *Netztransformator nach IEC 61558-2-1, DIN EN 61558, VDE 0570 Teil 2-1 (ohne VDE-Prüfzeichen) Short circuit proof safety isolating transformer to IEC 61558-2-6, DIN EN 61558-2-6, VDE 0570 part 2-6 *Transformer to IEC 61558-2-1, DIN EN 61558-2-1, VDE 0570 part 2-1 (without VDE-Approval) W v 1 X Typ Type Eingangsspannung Input voltage , VA 22.0 VA Power Prüfzeichen C-UL-US, ENEC 10 (VDE) C-UL-US, ENEC 10 (VDE) C-UL-US, ENEC 10 (VDE
-
Original
EI - 28 TRANSFORMER EI - 33 TRANSFORMER EI 28 transformer 2x24 transformer 220 EI 33 transformer EI - 33 CA TRANSFORMER
Abstract: Data sheet: Safety isolating transformers type DCT Description.: dc power supply/ safety isolating transformer Manufactured to.: EN 61558 / VDE 0570 , EN 50 022) Packing.: separately packed in cartons Schematic , supplies encapsulated in resin. These power supplies have stable plastic cases for panel mounting on DIN EN , circuit and overload * for panel installation on mounting rails (DIN EN 50 022) transformer -
OCR Scan
Abstract: '  Single-phase control transformers according to VDE 0570 part 2-2, EN 61558-2-2 Single-phase isolation transformers according to VDE 0570 part 2-4, EN 61558-2-4 ï'  Design: Type RSTN 50 RSTN 75 RSTN , information: Single-phase grid transformers according to VDE 0570 part 2-1, EN 61558-2-1 Single-phase control transformers according to VDE 0570 part 2-2, EN 61558-2-2 Single-phase isolation transformers according to VDE 0570 part 2-4, EN 61558-2-4 Single-phase safety transformers according to VDE 0570 part RIEDEL
Original
D-74532 D-38875