500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Top Results

Part Manufacturer Description Datasheet BUY
ISL32741EFBZ Intersil Corporation PROFIBUS Compliant 6kV VDE-Reinforced Isolated RS-485 Transceiver; SOIC16; Temp Range: See Datasheet visit Intersil
ISL32741EIBZ-T Intersil Corporation PROFIBUS Compliant 6kV VDE-Reinforced Isolated RS-485 Transceiver; SOIC16; Temp Range: See Datasheet visit Intersil
ISL32741EIBZ Intersil Corporation PROFIBUS Compliant 6kV VDE-Reinforced Isolated RS-485 Transceiver; SOIC16; Temp Range: See Datasheet visit Intersil
ISL32741EFBZ-T7A Intersil Corporation PROFIBUS Compliant 6kV VDE-Reinforced Isolated RS-485 Transceiver; SOIC16; Temp Range: See Datasheet visit Intersil
ISL32741EFBZ-T Intersil Corporation PROFIBUS Compliant 6kV VDE-Reinforced Isolated RS-485 Transceiver; SOIC16; Temp Range: See Datasheet visit Intersil
ISL32741EIBZ-T7A Intersil Corporation PROFIBUS Compliant 6kV VDE-Reinforced Isolated RS-485 Transceiver; SOIC16; Temp Range: See Datasheet visit Intersil

VDE 0551 EN 60 742

Catalog Datasheet MFG & Type PDF Document Tags

VDE 0551 EN 60 742

Abstract: IEC-742 TRANSFORMER DIN EN 60 742, VDE 0551, EN 60 742, IEC 742, IEC 61 558 ENEC 10 (VDE), UL, C-UL zwischen Ein- und , Input voltage Frequency Output voltage safety isolating transformer to DIN EN 60 742, VDE 0551, EN 60 742, IEC 742, IEC 61 558 ENEC 10 (VDE), UL, C-UL between input and output circuit 5000 V, 50 Hz non-short-circuit-proof encapsulated prepared for class II equipment IP 00 + 40 °C VDE = B, UL = class 105 230 V 50 Hz to , °C VDE = B, UL = dass 105 230 V 50 Hz bis 60 Hz nach Tabelle Doppelspannung für Reihen- oder
-
OCR Scan

block VDE 0551 EN 60 742

Abstract: VDE 0551 t 60 e Ausgangsspannung Sicherheits-Transformator nach DINEN 60 742, VDE 0551, EN 60 742, IEC 742, IEC 61 558 ENEC 10 (VDE), UL, C-UL zwischen Ein- und Ausgangsstromkreisen 5000 V, 50 Hz bedingt kurzschlußfest vergossen vorbereitet für Geräte der Schutzklasse II IP00 + 40 °C VDE = E, UL = dass 105 230 V 50 Hz bis 60 Hz nach , safety isolating transformer to DIN EN 60 742, VDE 0551, EN 60 742, IEC 742, IEC 61 558 ENEC 10 (VDE), UL , prepared for class II equipment IP 00 + 40 °C VDE = E, UL = class 105 230 V 50 Hz to 60 Hz acc. to table
-
OCR Scan

VDE 0551 EN 60 742

Abstract: block VDE 0551 EN 60 742 VDE 0551, EN 60 742, IEC 742 cOutput Voltage: Acc. to Table Twin Secondary Windings for Series or , Block Transformers Visit Block Transformer's Website at www.blockusa.com FL Range Dual Primary 115 V + 115 V Low Profile — NEW — Features cDesign: Safety Isolating Transformer to VDE 0551, EN 60 742, IEC 742, IEC 61 55 cTest Voltage: Between Input and Output Circuits 5000 V, 50 Hz cType: Encapsulated cInput Voltage: 2 ¥115 V for Series or Parallel Connection cOutput Voltage: Acc. to Table Twin
Allied Electronics Catalog
Original

VDE 0551 EN 60 742

Abstract: transformer vde 0551 Data sheet: isolating transformers type TIM Description.: isolating transformer Approval. : VDE 0551/EN 60 742 Test voltage , .: 50 - 60 Hz Output voltage. : 2x115 V Connections , BLOCK TRANSFORM ATOREN ELEKTRONIK GMBH & CO. KG, 27283 VERDEN, GERM ANY 2 O utput p ow er 60 V A Type TIM 60 Height 76 mm Weight 1550 g Ground area 166 mm x 77 mm Input Voltage ( V ) .
-
OCR Scan

VDE 0551 EN 60 742

Abstract: transformer 230v to 60v . : VDE 0551/EN 60 742; UL 506;CSA 22.2 Test voltage. : PRI - SEC 4000 V , Frequency. : 50 - 60 Hz Output voltage. : 2 x 60V - 55V - , ) Weight ( kg ) A 78 84 96 105 150 150 B (1) 60 76 88 103 111 154 B (2) 72 96 96 , 105/60,5 The mounting kit type UB is made of rigid aluminium sections with an integrated steel
-
Original

VDE 0551 EN 60 742

Abstract: block VDE 0551 EN 60 742 : Safety Isolating Transformer to VDE 0551, EN 60 742, IEC 742 cOutput Voltage: Acc. to Table Twin , VDE 0551, cTerminals: Pins for Printed Circuit Boards EN 60 742, IEC 742 Description — NEW — cTest , Proof — NEW — Features Features (Continued) cDesign: Safety Isolating Transformer to VDE 0551, cTerminals: Pins for Printed Circuit Boards EN 60 742, IEC 742 cTest Voltage: Between Input and Output
Allied Electronics Catalog
Original

VDE 0551 EN 60 742

Abstract: PT 13/1/pc50a EN 60 742, IEC 742 : ENEC 10 (VDE), UL, C-UL : zwischen Ein- und Ausgangsstromkreisen 5000 V, 50 Hz : bedingt kurzschlußfest : vergossen : vorbereitet für Geräte der Schutzklasse II : IP00 : +40 °C : VDE = E, UL = dass 105 : safety Isolating transformer to VDE 0551 EN 60 742, IEC 742 : ENEC 10 (VDE), UL , Isolierstoffklasse des Isoliersystems : Sicherheitstransformator nach VDE 0551, Design Approvals Test voltage , : encapsulated : prepared for class II equipment : IP 00 : +40 °C : VDE = E,UL = class 105 Eingangsspannung
-
OCR Scan

vde 0550

Abstract: 8fl2 VDE 0551, EN 60 742, IEC 742, IEC 61 558 nach Tabelle zwischen Ein- und Ausgangsstromkreisen 5000 V, 50 Hz nicht kurzschlußfest vergossen vorbereitet für Geräte der Schutzklasse II IP00 +40 °C VDE, SEV = E, UL = dass 105 2x115 V für Reihen- oder Parallelschaltung 50 Hz bis 60 Hz nach Tabelle , isolating transformer to VDE 055 1, EN 60 742, IEC 742, IEC 61558 acc. to table between input and output , VDE, SEV =E,UL = class 105 2 x 115 V for series or parallel connection 50 Hz to 60 Hz acc. to table
-
OCR Scan

VDE0550

Abstract: vde 0550 : Sicherheitstransformator nach VDE 0551, EN 60 742, IEC 742 : nach Tabelle Design Approvals Test voltage Short circuit , Tabelle : safety isolating transform er to VDE 0551 E N 6 0 742, IEC 742 : acc. to table : between in p , II equipm ent : IP 00 : acc. to table : : : : VDE = B,UL = class 105 230 V 50 Hz to 60 Hz acc. to , : VDE = B, UL = dass 105 : 230 V : 50 Hz bis 60 Hz A usgangsspannung : nach Tabelle , Efficiency nach VDE 0550 Teil 1/12.69 ito V D E 0550 Part / 12.69 SEC-Leerlaufspannung x Faktor
-
OCR Scan

vde 0550

Abstract: VDE 0551 EN 60 742 des Isoliersystems Sicherheitstransformator nach VDE 0551, EN 60 742, IEC 742 nach Tabelle , er to VDE 0551, E N 6 0 742, /EC 7 4 2 acc. to table between in p u t and o u tp u t circuit 5000 V, 50 Hz short-circuit-proof encapsulated prepared for class II equipm ent IP 00 acc. to table VDE = B,UL = class 105 230 V 50 Hz to 60 Hz acc. to table twin secondary windings fo r series o r p a ra lle , e re ite t fü r Geräte der Schutzklasse II IP00 nach Tabelle VDE = B, UL = dass 105 Design
-
OCR Scan

block VDE 0551 EN 60 742

Abstract: X-1875 DIN EN 60 742, VDE 0551, EN 60 742, IEC 742, IEC 61 558 : acc. to table : between input and output , DIN EN 60 742, VDE0551, EN 60 742, IEC 742, IEC 61 558 Prüfzeichen nach Tabelle zwischen Ein- und , : + 40 °C : VDE, SEV = E, UL = class 105 : 2 x 115 V for series or parallel connection : 50 Hz to 60 , Isoliersystems : VDE, SEV = E, UL = dass 105 : 2x115V Eingangsspannung für Reihen- oder Parallel-Schaltung Frequenz : 50 Hz bis 60 Hz Ausgangsspannung : nach Tabelle Doppelspannung für Reihen- oder
-
OCR Scan
block VDE 0551 EN 60 742 X-1875 VDE 0551 EN 60 742

E251-230

Abstract: abb timer stt 11 . 51 3 M orp metsyS Schalter 16, 25 and 32 A Series E 220 DIN EN 60 669-1, VDE , 91 4 SK 0079 Z 00 in mm Switches 16, 25 and 32 A Series E 220 DIN EN 60 669-1, VDE , 240: AC 21 A to VDE 0660 Part 107, DIN EN 60 947-3 and IEC 947-3 E 270: AC 22 A to VDE 0660 Part 107 , DIN EN 60 669-1, VDE 0632 Part 1, IEC 947-3 Modular installation equipment Switches 45, 63, 80 , Switches 63 and 80 A E 463/3-KB, E 480/3-KB, E 463/3-SL DIN EN 60 669-1, VDE 0632 Part 1 M orp
ABB Stotz-Kontakt
Original
E251-230 abb timer stt 11 abb timer stt 17 s ABB STT 111 E 234-mfr E252-230 S0002 D-69006

bs 3535

Abstract: G101000252 EURORANGE TRANSFORMERS 230/240Vac PRIMARY TOROIDAL CONSTRUCTION HORIZONTAL OR VERTICAL FIXING OPTION THERMALLY PROTECTED PRIMARY FULLY ENCAPSULATED TO UL 94VO DUAL SECONDARIES LOW MAGNETIC FIELD LOW SURFACE TEMPERATURE CONFORMS TO EN 60/742 BS 3535 IEC 742 VDE 0551 UL 506 LOW INDUCED NOISE (AUDIBLE , 150mm long ±5mm EN60/742, BS 3535, IEC 742, VDE 0551, UL 506. 105°C Typs Load VA Secondary RMS , 25 43 45 C 75 101 75 82 49 D 36 36 40 E 50 60 75 50 Fixings M4x3 M4x3 M6x3 M4x3 12 Insert depth 8 8
-
OCR Scan
G101000252 bs 3535 AVEL 230/240V HD472-S1 50/60H EN60/742 G100150062 G100150122

230v AC primary to 9v 500ma secondary transformer

Abstract: 230v ac to primary 15v 500ma secondary transformer Benefits · International certifications: UL 506, CSA C22.2, EN 60/742, EN 61 558, SEV 1003, VDE 0551, VDE , . Flash tested: at 5K VAC. Mounting: On P.C. board. Certifications: VDE 0551, VDE 0570, IEC 742, UL 506, DIN/EN60 742, EN61 558, CSA C22.2, SEV 1003; EN 60-950 available on request. Transformer , High reliability General Specification for OB types Primaries: 115/230 V. Frequency: 50/60 Hz , transformers meet VDE Continued on next page 860/355-4711 · FAX 860/354-8597 www.avellindberg.com · sales
Avel Lindberg
Original
OB10-9 OB30-15 230v AC primary to 9v 500ma secondary transformer 230v ac to primary 15v 500ma secondary transformer 230V AC primary to 12V, 1A secondary transformer transformer 230V to 12V 500mA transformer 230v to 9v, 500ma secondary transformer 12v and 500ma transformer

DIN EN 60999-1

Abstract: EN 175 301-801 / DIN EN 60 742/VDE 0551: 1995-09 Isolating transformers and safety isolating transformers ­ , : 1998-03 IEC 60 255/DIN VDE 0435 (1999-01-00) VDE 0551 = DIN EN 60742 (1995-09) DIN EN 55 011/VDE 0875 part , principles, requirements and tests DIN EN 60 204 1/VDE 0113 part 1: 11.98 (IEC 60 204-1: 1992, modified , equipment in areas with explosion hazard DIN EN 60 079-14/VDE 0165 part 1: 08.98 EN 50 014: 1992/DIN VDE , Electrical equipment for areas with explosion hazard; intrinsic safety "i" DIN EN 60 529: VDE 0470 part 1
Wieland Electric
Original
0106-100/VDE DIN EN 60999-1 EN 175 301-801 DIN IEC 600 68-2-2 IEC 439-3 din iec 512 61529 110-1/VDE 0106-101/VDE 0108-1/VDE 0110-1/VDE 178/VDE

transformer 230 V 50 Hz

Abstract: compact power supply / safety isolating transformer according to VDE 0551, DIN EN 60 742, IEC 742 in , installation in control cubicle IP 20 prepared for class II equipment max + 60°C by self-cooling (natural air , Packaging 230 V, ac or 400 V, ac + 10% 50 Hz to 60 Hz typ. 24 V, dc rated voltage according to medium , screw-type terminals panel installation on mounting rails (DIN EN 50 022), up to 5 Amp. output voltage , against electric shock according to VDE 0106 part 101 and finger safe according to UVV VBG4 >indication of
-
OCR Scan
transformer 230 V 50 Hz

block VDE 0551 EN 60742

Abstract: transformer vde 0551 safety isolating transformer to VDE 0551, DIN EN 60742, IEC 742 in accordance with DIN 19240,and UL , temperature . : max.+ 40 °C (max. 60°C with reduced power rating) Insulation class of the insulation , . : 50 - 60 Hz Output voltage. : typ. 24V dc stabilized Output current , mounting rails (DIN EN 50 022) (additional screw mounting for 5A type) Packing , power supply typeGLS are designed for easy installation ontosatndard mounting rails (DIN EN 50 022
-
Original
block VDE 0551 EN 60742 transformer vde 0551 IEC-742 TRANSFORMER 24v transformer windings EN 60 742 transformer

vde 0551 en60742

Abstract: transformer vde 0551 en60742 Isoliersystems Sicherheitstransformator nach VDE 05S1, EN 60 742, IEC 742 nach Tabelle zwischen Ein- und , ; safety isolating transformer to VDE 0551, EN60742,IEC742 : acc. to table : between input and output , : acc, to table VDE = B,UL = class 105 230 V 50 Hz to 60 Hz acc. to table twin secondary windings for , Tabelle VDE = B, UL = dass 105 Design Approvals Test voltage Short circuit strength Type Safety class , ) Eingangsspannung Frequenz 230 V 50 Hz bis 60 Hz Ausgangsspannung Anschlüsse Befestigung Verpackung nach
-
OCR Scan
vde 0551 en60742 transformer vde 0551 en60742 VDE 0551 t 60 e vde 0550 VDE0550 nach VDE 0551

IEC-742 TRANSFORMER

Abstract: iec 742 (12.13 lb) Protection IEC 364-4-41 or HD 384.04.41 (KDE 0100, Part 410) Transformer to VDE 0551/EN 60742/IEC 742 Temperature range ­20_C to +60_C (­4_F to +140_F) Mounting attitude , 115/230V AC "5% 50/60 Hz Max. 4,0 mm2 (0.006 in2) 24V DC
Vickers
Original
iec 742 Vickers EN 60742 a-35 EHA-PSU-704-A 0551/EN GB-2419

transformer vde 0551

Abstract: DGU524-32 / Sicherheits transformator nach VDE 0551, DIN EN 60 742, IEC 742 in Verbindung mit DIN 19 240 : zwischen Ein , . +60 °C : Selbstkühlung : B : Y N d 11 (DG5), IlldO (DGU5) Design dc power supply/safety isolating transformer to VDE0551, DIN EN 60 742, IEC742 In accordance with DIN 19 240 between input and output circuit 4500 V, 50Hz enclosed, for installation in control cubicle IP 00 : I max. +60 °C by self , bis 60 Hz type DG 5: 3x400 Vac, ±5% type DGU5: delta connection: 3 x208,5 V/220 V/23 7,5 V/ 242.5 V
-
OCR Scan
DGU524-32 resistor 330 V1265 V1277 DG5400/24-6 DG5400/24-10