500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Top Results

Part Manufacturer Description Datasheet BUY
PTDC1000QPWQ1 Texas Instruments Ultrasonic Analog-Front-End 28-TSSOP visit Texas Instruments
PGA460TPWQ1 Texas Instruments Automotive Ultrasonic Signal Processor & Transducer Driver 16-TSSOP -40 to 105 visit Texas Instruments
PGA460TPWRQ1 Texas Instruments Automotive Ultrasonic Signal Processor & Transducer Driver 16-TSSOP -40 to 105 visit Texas Instruments Buy
TDC1000PWR Texas Instruments Ultrasonic Sensing Analog Front End for Level, Concentration & Flow Sensing 28-TSSOP -40 to 125 visit Texas Instruments Buy
TDC1000PW Texas Instruments Ultrasonic Sensing Analog Front End for Level, Concentration & Flow Sensing 28-TSSOP -40 to 125 visit Texas Instruments
PGA460TPWR Texas Instruments Ultrasonic Signal Processor and Transducer Driver 16-TSSOP -40 to 105 visit Texas Instruments Buy

Ultrasonic amplifier schematic circuit

Catalog Datasheet MFG & Type PDF Document Tags

RF transmitter rt4 433.9

Abstract: RT2-433 Integrated Antenna High Reliability Laser Trimming Process CIRCUIT SCHEMATIC VCC In Wireless , Reliability DIL Package CIRCUIT SCHEMATIC VCC In Wireless security systems Car Alarm systems , gate controls Sensor reporting CIRCUIT SCHEMATIC VCC EA In Electrical Characteristics , systems Car Alarm systems Remote gate controls Sensor reporting CIRCUIT SCHEMATIC VCC EA In , Wireless security systems Car Alarm systems Remote gate controls Sensor reporting CIRCUIT SCHEMATIC
Telecontrolli
Original

40KHZ ULTRASONIC transducers

Abstract: 40KHz ultrasonic interface optimized. The MSP430 and the ultrasonic signal amplifier circuit are powered by a regulated 3.6-V supply , R6 100K R4 100K Figure 1. Circuit Schematic 4 CC Ultrasonic Distance Measurement , . 9 6 6 6 7 7 7 7 List of Figures 1 Circuit Schematic . . . . . . . . . . . . . . . . . , . Figure 1 shows the circuit schematic diagram of this application. The MSP430F413 (U1) is the core of , single-supply operation of the operational amplifier. The amplified ultrasonic signal swings above and below
Texas Instruments
Original
40KHZ ULTRASONIC transducers 40KHz ultrasonic interface ultrasonic transducer 40khz 9V 40khz ultrasonic receiver and transmitter ultrasonic distance circuit design 40KHz Ultrasonic Transducer SLAA136A

Ultrasonic amplifier schematic circuit

Abstract: 400EP14D who are not very familiar with analog circuit and/or the operation of ultrasonic transducers. By using this module engineers can focus firstly on the other fields of digital circuit and software , analog circuit based on the module construction or consult with factory for making your own module for , frequencies High Gain Amplifier: varies with time over 32 steps Integrated Band Pass Filter: reduces , transmitted, the slope of the variable gain amplifier, and the pulse repetition rate Board size: 27.9 * 18
Pro-Wave Electronics
Original
SRM400 400EP14D PW0268 400EP18A Ultrasonic amplifier schematic circuit ultrasonic distance measurement circuit design sonar PW-0268 250KH BAV99 BSS123

Ultrasonic amplifier schematic circuit

Abstract: ultrasonic distance circuit design who are not very familiar with analog circuit and/or the operation of ultrasonic transducers. By using this module engineers can focus firstly on the other fields of digital circuit and software , analog circuit based on the module construction or consult with factory for making your own module for , frequencies High Gain Amplifier: varies with time over 32 steps Integrated Band Pass Filter: reduces , transmitted, the slope of the variable gain amplifier, and the pulse repetition rate Board size: 27.9 * 18
Pro-Wave Electronics
Original
150 khz ultrasonic transducers circuit diagram of transducer RC CAR circuit diagram ultrasonic amplifier circuit diagram sonar ranging circuit diagram of rc car 660KHZ MMBT3904

ultrasonic microcontroller based distance meter

Abstract: circuit diagram of moving LED message display ultrasonic acoustic transducer and the ranging circuit board (Figure 2). Together these components can , design. The schematic of the circuit board is shown in Fig. 2. Chapter 6: New Jersey Institute of , Ultrasonic Cane For The Blind Designer: Tow-Odd Hoydal Disabled Coordinator: Dr. Thomas Findley Kessler , and the Ultrasonic Ranger with the Ultrasonic Ranger as a primary mobility aid. The Ultrasonic Ranger circuitry is divided into separate modules. The first module is the ultrasonic ranging module. It
-
Original
ultrasonic microcontroller based distance meter circuit diagram of moving LED message display 8751 microcontroller simple circuit diagram of moving LED message display ultrasonic sensor for obstacle detection with microcontroller ic Ultrasonic transmitter receiver

Ultrasonic amplifier schematic circuit

Abstract: infrared receiver diode ilte r P e a k H o ld Q 4 5 ^ G ro u n d Internal Schematic Circuit Description (Refer to Fig. 1) Q 1-Q 4 set the bias on the amplifier input at approximately 2.8V Q 6 -Q 1 0 form the input amplifier, which has a gain of about 8 0 dB when R(Pin 6) = 0 Q5 sinks input current from the photo-diode , GL3273 REMOTE CONTROL WIDEBAND AMPLIFIER WITH DETECTOR Description The GL3273 is intended for , used with tuned circuit for narrow bandwidth, lower noise operation. · Small package size · Minimum
-
OCR Scan
L3273 infrared receiver diode ultrasonic receiver impedance ultrasonic preamp

40KHZ ULTRASONIC transducers

Abstract: ultrasonic range meter IC URL: http://www.prowave.com.tw Ultrasonic Sonar Ranging IC - PW0268 Features: SSOP20 , Gain Amplifier: varies with time over 32 steps Integrated Band Pass Filter: reduces external component , of the variable gain amplifier, and the pulse repetition rate. The PW0268 IC is suitable for use in , : The PW-0268 ultrasonic sonar ranging IC is ideally suited for echo ranging systems. This chip has many , transducer sensitivities. The 32-step Time Controlled Variable Gain Amplifier slope can be modified by
Pro-Wave Electronics
Original
K4000001 ultrasonic range meter IC distance measure ultrasonic transducer k4000004 Ultrasonic Transducer application notes 400EP18A application Piezo Transducer ultrasonic S40000 S32768 K4000002 K4000003 235SR130

AN-69 for lm384

Abstract: Ultrasonic amplifier schematic circuit projector systems, etc. See AN-69 for circuit details. n n n n n n n n Schematic Diagram , LM384 - 5-W Audio Power Amplifier Features Typical Application click for larger image · , Application Notes (see below) Datasheet RoHS Compliance Information LM384 5W Audio Power Amplifier LM384 5W Audio Power Amplifier (Japanese) Package Availability, Models Package Part Number Type , 1000 25 NSUZXYYTTE# LM384N General Description The LM384 is a power audio amplifier for
National Semiconductor
Original
AN-69 for lm384 12v 50 watt audio amplifier circuit diagram 5W AUDIO AMPLIFIER CIRCUIT DIAGRAM saxon N14A phonograph

"Piezoelectric Sensor"

Abstract: ultrasonic piezoelectric transducer driver and other moving components. Ultrasonic analysis, an extension of vibration analysis, uses higher , and ultrasonic noise will increase. An increase of about 12 dB indicates possible impending failure , , vibration analysis and ultrasonic analysis require two different pieces of equipment. A single, cost-effective instrument that can monitor the complete frequency range would be useful. A schematic diagram of a vibration and ultrasonic analysis signal chain is shown in Figure 1. Normalized Amplitude The
National Semiconductor
Original
ultrasonic piezoelectric transducer driver schematic ultrasonic sensor radar using ultrasonic sensor 2 MHz ultrasonic sensor CIRCUIT piezoelectric SENSOR 40 KHZ

T40 16 ultrasonic

Abstract: T40-16 ,r40-16 ultrasonic sensor Implementation The schematic of the ultrasonic range finder is given in Section 4. Details of the ultrasonic , Amplification Circuit Upon receiving an ultrasonic signal through a reception sensor, the signal is amplified , Ultrasonic Range Finder (Ultrange) Figure 5. Signal Detection Circuit After the amplification circuit , 38024F CPU Board is connected to the Ultrasonic Range Finder circuit as follows: 38024F CPU Board Ultrasonic Range Finder Object JP4 Ultrasonic Transmitter Circuit TX 3 P32/ TMOFH H8/38024F
Renesas Technology
Original
T40 16 ultrasonic T40-16 ,r40-16 ultrasonic sensor Sensor Ultrasonic 40Khz rx tx T40-16 ultrasonic sensor Ultrasonic Range Finder Ultrasonic power generator schematic H8/300L H8/38024 AN0403006/R

ultrasonic generator 40khz

Abstract: T40-16 r40-16 ultrasonic sensor The schematic of the ultrasonic range finder is given in section 4. Details of the ultrasonic , Amplification Circuit Upon receiving an ultrasonic signal through a reception sensor, the signal is amplified , Series Ultrasonic Range Finder (Ultrange) Figure 5 Signal Detection Circuit After the amplification , The H8/38024F CPU board is connected to the Ultrasonic Range Finder circuit as shown in figure 6: 38024F CPU Board Ultrasonic Range Finder Objec t JP4 Ultrasonic Transmitter Circuit TX 3
Renesas Technology
Original
ultrasonic generator 40khz T40-16 r40-16 ultrasonic sensor medical application of ultrasonic waves T40 ultrasonic sensor T40-16 Piezoelectric Crystal application of ultrasonic sound waves RES06B0009-0100/R

ultrasonic 40 khz transducer

Abstract: RCA photomultiplier servo amplifier A3B, which is biased from the LVDT demodulator output. The output of the circuit is , amplifier which drives the Q3-Q5 combination to complete a feedback loop around the Q1-Q2 driven , current source. The LF412 amplifier performs a current-to-voltage conversion with the 1 M resistor , characteristics and very long life. Figure 1 details a typical PMT along with a signal conditioning circuit. The , . In this circuit, the detector is terminated directly into a high speed 50 oscilloscope. In Figure 5b
National Semiconductor
Original
ultrasonic 40 khz transducer RCA photomultiplier mk-109 ultrasonic transducer excitation circuit lvdt accelerometer Schaevitz accelerometer LM329 AN-301

RCA photomultiplier

Abstract: 2n2222 h 331 amplifier A3B which is biased from the LVDT demodulator output The output of the circuit is taken across the , circuit The tube is composed of a photosensitive cathode an anode a focusing electrode and ten dynode , dynode potentials to the tube The supply is stabilized by the LF412 amplifier which drives the Q3-Q5 , tube output and appears as an almost ideal current source The LF412 amplifier performs a , milliseconds the optical chopper provides a modulated light signal to the detector The amplifier output may be
National Semiconductor
Original
2n2222 h 331 ultrasonic transducer drive circuits MK109 schematic ultrasonic distance meter LVDT sensor for aerospace lvdt accelerometer sensor

decode counter 7490

Abstract: ultrasonic transducer driver circuits ultrasonic transducer is desirable to promote fast, low jitter, hi-fidelity response free of resonances and , their respective owners. BOTTLE CAP AND STIFFENING PLATE GLASS BOTTLE 6" ULTRASONIC TRANSDUCER , (ALL CAP VIEWS ARE X-RAY) Figure 1. Ultrasonic Transducer Rigidly Mounts Within Stiffened Cap , Figure 2. Photograph Details Cap Assembly, Partially Views Glass Enclosed Measurement Path. Ultrasonic , drives it with a short impulse, launching an ultrasonic event into the measurement path. Simultaneously
Linear Technology
Original
decode counter 7490 ultrasonic transducer driver circuits Ultrasonic transmitter receiver transit time hp5082-7300 Ultrasonic Electrostatic Transducer ultrasonic transducer polaroid AN131-14 AN131-15 AN131-16

ultrasonic transducers 50w 40 khz

Abstract: Ultrasonic amplifier 50w bandwidth and high voltage output of the MP39 allows driving ultra-sonic transducers via a resonant circuit including the transducer and a matching transformer. The load circuit appears resistive to the MP39. 12-14 30 23 24 MP39 25 ULTRA-SONIC AMPLIFIER EXTERNAL CONNECTIONS - MP39CL , internal amplifier losses. The current limiting resistor may not be placed anywhere in the output circuit , POWER OPERATIONAL AMPLIFIER MP39 M I C R O T E C H N O L O G Y HTTP://WWW.APEXMICROTECH.COM
Apex Microtechnology
Original
DIP10 ultrasonic transducers 50w 40 khz Ultrasonic amplifier 50w 100khz ultrasonic transducers Ultrasonic Ceramic Transducers MP39 546-APEX MP39U

ultrasonic transducers 50w 40 khz

Abstract: Ultrasonic amplifier 50w MP38. 12-14 30 23 24 MP38 6 25 18-20 26 ULTRA-SONIC AMPLIFIER EXTERNAL , POWER OPERATIONAL AMPLIFIER MP38 M I C R O T E C H N O L O G Y HTTP://WWW.APEXMICROTECH.COM , cost-effective high voltage MOSFET power operational amplifier constructed with surface mount components on a , portion of the amplifier to operate at higher supply voltages than the high current output stage. The amplifier is then biased to achieve close linear swings to the supply rails at high current for extra
Apex Microtechnology
Original
IN3029 Ultrasonic amplifier MP38 MP38U

ultrasonic transducers 50w 40 khz

Abstract: Ultrasonic amplifier 50w allows driving ultra-sonic transducers via a resonant circuit including the transducer and a matching , CC NC -ILIM -50V RCL ULTRA-SONIC AMPLIFIER TUNED TRANSFORMER GENERAL Please read , amplifier to operate at higher supply voltages than the high current output stage. The amplifier is then , where output crossover distortion is not important. Power Operational Amplifier FEATURES · HIGH , power operational amplifier constructed with surface mount components on a thermally conductive but
Apex Microtechnology
Original
MP39A MP38A

1 MHZ ULTRASONIC transducers

Abstract: 100khz ultrasonic transducers bandwidth and high voltage output of the MP38 allows driving ultra-sonic transducers via a resonant circuit , ULTRA-SONIC AMPLIFIER TUNED TRANSFORMER Please read Application Note 1 "General Operating Considerations , ±100 Volts (200V total). Optional boost voltage inputs allow the small signal portion of the amplifier to operate at higher supply voltages than the high current output stage. The amplifier is then biased , where output crossover distortion is not important. Power Operational Amplifier FEATURES · HIGH
Cirrus Logic
Original
1 MHZ ULTRASONIC transducers ULTRASONIC transducer 50w

Ablebond 36-2

Abstract: 71-1LM1 DC ­ 15 GHz HBT Series-Shunt Amplifier Technical Data HMMC-5220 Features · High Bandwidth, F , 15 GHz, 9.5 dB gain, feedback amplifier designed to be used as a cascadable gain block for a variety , sensitivity to process variations and provides 50 ohm input/output port matches. Furthermore, this amplifier , a 50 system. amplifier's gain may be reduced by ~0.5 dB. Figure 4 shows a recommended bonding , with an ultrasonic power of roughly 55 dB for a duration of 76 ± 8 msec. A guided wedge at an
Hewlett-Packard
Original
Ablebond 36-2 71-1LM1 Ablebond 190 ablebond technical hmmc-5 5968-1782E

ultrasonic transducers 50w 40 khz

Abstract: Ultrasonic amplifier 50w ULTRA-SONIC AMPLIFIER TUNED TRANSFORMER GENERAL Please read Application Note 1 "General Operating , amplifier losses. The current limiting resistor may not be placed anywhere in the output circuit except , amplifier to operate at higher supply voltages than the high current output stage. The amplifier is then , where output crossover distortion is not important. Power Operational Amplifier FEATURES · HIGH , power operational amplifier constructed with surface mount components on a thermally conductive but
Cirrus Logic
Original
Showing first 20 results.