NEW DATABASE - 350 MILLION DATASHEETS FROM 8500 MANUFACTURERS

Datasheet Archive - Datasheet Search Engine

 

Direct from the Manufacturer

Part Manufacturer Description PDF Samples Ordering
TCM1050P Texas Instruments Dual Transient-Voltage Suppressor 8-PDIP ri Buy
TCM1050DR Texas Instruments Dual Transient-Voltage Suppressor 8-SOIC ri Buy
TCM1050D Texas Instruments Dual Transient-Voltage Suppressor 8-SOIC ri Buy

Triac soft turn on

Catalog Datasheet Results Type PDF Document Tags
Abstract: TRIAC pulse train output will turn on 2 seconds once detecting an active motion Figure 1. Quick Check , Turn on 25% during night without motion voltage variation conforms to the criteria (refer to the , for triac drive and level for relay CDS to enable/disable output Adjustable output on time duration , disabled during this period, meanwhile, TRIAC and RELAY output will hold on in order to indicator system , control by switching the ZC signal. Open AUTO TRIAC output can soft start when activated by a ... Original
datasheet

12 pages,
171.19 Kb

AUTOMATIC LIGHT transfer function amplifier circuit re200b PIR D 203 S Triac based Lamp Dimmer power control 230v light dimmer PIR SENSOR IS MOTION SENSOR RE200B sensor dimmer 1-10V design 220v dimmer triac 220v light dimmer re200b amplifier PT8A2612 PT8A2612 abstract
datasheet frame
Abstract: Pin Description Pin No. Symbol Description 1 LOW Soft wind output (driving TRIAC). 2 HEAD Swing head control output (driving TRIAC). 3 BD Buzzer output. 4 OSCI 455k Hz crystal oscillator input. 5 , Condition Operating Voltage Vdd 4.0V 4.5V 6.0V Current On TRIAC Driver Pin Itriac - 10mA - Vout = 3V , wind modes : Constant wind. Rhythmical wind. Sleep wind. . Three wind grades : Soft wind. Medium wind , supply. 20 LIGHT Lamp control output (driving TRIAC). 21 HIGH Strong wind output (driving TRIAC). 22 ... OCR Scan
datasheet

7 pages,
2254.9 Kb

10822 455k d 1667 SD308 SD308-B SD308-C SD308-D SD308-E SD308-F SD7017-455 TRIAC Soft start circuit SD308-A Temperature Base Fan Speed controller triac arc control Triac soft turn on SD308 abstract
datasheet frame
Abstract: Condition Operating Voltage Vdd 4.0V 4.5V 6.0V Current On TRIAC Driver Pin Itriac - 10mA - Vout = 3V , wind modes : Constant wind. Rhythmical wind. Sleep wind. . Three wind grades : Soft wind, Medium wind. , , 1997 E? Super Device SD307 SD307 Pin Description Pin No. Symbol Description 1 LOW Soft wind output (driving TRIAC). 2 HEAD Swing head control output (driving TRIAC). 3 BD Buzzer output. 4 OSCI 455k Hz , LED pattern common pin 2. 17 vss Negative power supply. 18 LIGHT Lamp control output (driving TRIAC ... OCR Scan
datasheet

7 pages,
1993.88 Kb

d 1667 LED 220V lamp circuit SD307 SD307-A SD307-B SD307-C SD307-E SD307-F SD7017-455 220V LED lamp circuit diagram SD307-D SD307 abstract
datasheet frame
Abstract: Device SD306 SD306 Pin Description Pin No. Symbol Description i LOW Soft wind output (driving TRIAC). 2 HEAD Swing head control output (driving TRIAC). 3 BD Buzzer output. 4 OSCI 455k Hz crystal oscillator , Condition Operating Voltage Vdd 4.0V 4.5V 6.0V Current On TRIAC Driver Pin Itriac - 10mA - Vout = 3V , wind modes : Constant wind. Rhythmical wind. Sleep wind. . Three wind grades : Soft wind. Medium wind , pin. 17 HIGH Strong wind output (driving TRIAC). 18 MID Medium wind output (driving TRIAC). F-9 SS ... OCR Scan
datasheet

7 pages,
1883.22 Kb

SD306-F d 1667 fan triac triac arc control SD306 SD306-A SD306-B SD306-C SD306-D SD306-E 455k Triac soft turn on SD306 abstract
datasheet frame
Abstract: reduction in power supplied would result. Since it is not possible to turn the triac off during a cycle, the , Conditions 31 41 mA Pin 4 voltage = 13.5V including triac gate drive current SHUNT VOLTAGE , in operation Load current inhibit in operation 5V on ramp C -0.8 +0.8 Vreg -0.5 -100 -75 , ) ABSOLUTE MAXIMUM RATINGS ELECTRICAL Triac gate voltage pin 2 Repetitive peak input current pin 4 Non , by incorporating a filtering capacitor across the tacho input. Negative Triac Gate Firing Pulses ... Original
datasheet

5 pages,
3246.7 Kb

triac phase control motor gate firing of d.c drive capacitor ac for triac capacitor trip device Phase control circuit soft start triac ac motor control with triac triac control 16 pin a circuit for firing angle in triac 5v DRIVE TRIAC GATE triac dc motor control circuits NEGATIVE DRIVE TRIAC GATE TDA2086 TDA2086 abstract
datasheet frame
Abstract: SD7oo5 Pin Description Pin No. Symbol Description 1 LOW Soft wind output (driving TRIAC). 2 HEAD Swing head control output (driving TRIAC). 3 BD Buzzer output. 4 OSCI 32768 Hz crystal oscillator , 5.0V Current On TRIAC Driver Pin Itriac - 10mA . Vout=3V Current On LED Driver Pin Idriving - 6mA , wind modes : Constant wind, Rhythmical wind, Sleep wind. . Three wind grades . Soft wind. Medium wind. , (driving TRIAC). 18 MID Medium wind output (driving TRIAC). F-2 Super Device SD7oo5 Absolute Maximum ... OCR Scan
datasheet

7 pages,
1827.05 Kb

SD7005-D SD7005-C SD7005 SD7005 abstract
datasheet frame
Abstract: an on/off switch The triac fires at each zero crossing Soft start to lengthen bulb life by reducing , once your hand fully leaves the sense field. On/Off Modes: The device will turn the lamp full on or , not turn the lamp on or off; your hand must be first removed for a second, then placed firmly over , sensitive (a common problem) then it can be very hard to turn the lamp full on/off by a large hand touch on , OFF MODE TWO Standard ON/OFF Soft start ON/OFF Dimmer Memory Dimmer No Mem ... Original
datasheet

5 pages,
153.95 Kb

dimmer switch QUANTUM CAPACITIVE AC LAMP DIMMER dimmer diagrams lamp dimmer with switch switch mode lamp dimmer lamp touch switch light dimmer soft start touch dimmer IC Quantum QT116 qt116 240VAC touch dimmer QT116 240VAC QT116 abstract
datasheet frame
Abstract: current at Triac turn on for universal motor 80 I(A) With soft start 60 Without soft start , turn on due to too short gate pulse width and Diagram b in Figure 5 shows a good Triac turn on. The , peak current at turn on as shown in Figure 8 can damage an 8 A Triac as it is close to ITSM value (max , reduction Triac turn on at peak mains voltage allows the reduction of the peak inrush current by 75% , show an example of Triac switching on a 2200 W universal motor with or without soft start. The ... Original
datasheet

16 pages,
695.04 Kb

gate pulse transformer AC Motor speed and soft start fridge triac control microwave oven schematic AN441 TRIAC control circuit Halogen lighting transformer Triac soft turn on universal AC Motor soft start triac drive circuit microwave oven magnetron microwave oven transformer AN441 abstract
datasheet frame
Abstract: the voltage on the ramp capacitor, (the discharge rate being equal but opposite to the soft start , supplied would result. Since it is not possible to turn the triac off during a cycle, the triac and motor , only. For more information on Zarlink's obsolete products and replacement product lists, please visit , including triac gate drive current SHUNT VOLTAGE REGULATOR Pin 4 Regulating voltage Voltage monitor , on ramp C -0.8 +0.8 Vreg -0.5 -100 -75 0 1 -50 V µA mV 100 30 40 60 10 mV ... Original
datasheet

6 pages,
539.23 Kb

AC Motor soft start IC triac tacho tda2086 TDA2086 TDA2086 abstract
datasheet frame
Abstract: result. Since it is not possible to turn the triac off during a cycle, the triac and motor should be , controlled acceleration. I Negative triac firing pulses 100mA guaranteed minimum. I Warning LED drive , voltage = 13.5V including triac gate drive current -16 -11 -14.75 -13.5 -9 V V -5.35 , operation Load current inhibit in operation 5V on ramp C V µA mV 60 10 1mA external load V , ) (0.3 Vreg) ABSOLUTE MAXIMUM RATINGS ELECTRICAL Value Units Triac gate voltage pin 2 ... Original
datasheet

6 pages,
43.27 Kb

tachogenerator and universal motor Triac soft start ic triac drive circuit voltage regulator using triac drill motor speed control circuit washing machine motor tacho power generator control circuit 220v DC MOTOR SPEED CONTROL USING triac ac tacho 220v ac voltage stabilizer circuit 80 ac to 220v ac stabilizer TDA2086 TDA2086 TDA2086 abstract
datasheet frame

Datasheet Content (non pdf)

Abstract Saved from Date Saved File Size Type Download
Over 1.1 million files (1986-2014): html articles, reference designs, gerber files, chemical content, spice models, programs, code, pricing, images, circuits, parametric data, RoHS data, cross references, pcns, military data, and more. Please note that due to their age, these files do not always format correctly in modern browsers. Disclaimer.
 
to turn on the device through S1, and 0V to turn off the device through S2. A remarkable effect applied to the gate through diode D1 is sufficient to charge the input capacitance C in and turn on and turn off the switch, a pulse is applied to the diode D2 which turns on T2, which in turn T1. As the pulse duration times required to turn the devices on and off are very small, this TRIAC on or off generates voltage spikes and uncontrolled dV/dt. In most cases a TRIAC
www.datasheetarchive.com/files/stmicroelectronics/stonline/books/ascii/docs/3703-v1.htm
STMicroelectronics 25/05/2000 17.9 Kb HTM 3703-v1.htm
applying different voltages: 15V to turn on the device through S1, and 0V to turn off the device through the gate through diode D1 is sufficient to charge the input capacitance C in and turn on the off the switch, a pulse is applied to the diode D2 which turns on T2, which in turn discharges the the pulse duration times required to turn the devices on and off are very small, this principle dimming circuits are controlled by TRIACs. Turning a TRIAC on or off generates voltage spikes and
www.datasheetarchive.com/files/stmicroelectronics/stonline/books/ascii/docs/3703.htm
STMicroelectronics 20/10/2000 18.38 Kb HTM 3703.htm
Output Max. Power to TRIAC Output Min. Power to TRIAC Set Fuzzy Mode Turn off the power Set Non-fuzzy on different characteristics of floor surfaces will be very desired for today's market. This new based on a new control-fuzzy logic. Fuzzy logic is a relatively new technology that enables machines and do. This note describes a universal motor power control implemented on a standard microcontroller inputs simultaneously. In a conventional vacuum cleaner, power control is designed based on a sample
www.datasheetarchive.com/files/stmicroelectronics/stonline/books/ascii/docs/2497-v4.htm
STMicroelectronics 11/01/2000 31.27 Kb HTM 2497-v4.htm
TRIAC Set Fuzzy Mode Turn off the power Set Non-fuzzy Mode Set Non-fuzzy Mode scrub to a more sophisticated mode. A vacuum cleaner that is able to do the cleaning based on based on a new control-fuzzy logic. Fuzzy logic is a relatively new technology that enables machines way people do. This note describes a universal motor power control implemented on a standard simultaneously. In a conventional vacuum cleaner, power control is designed based on a sample floor whereby
www.datasheetarchive.com/files/stmicroelectronics/stonline/books/ascii/docs/2497-v2.htm
STMicroelectronics 25/05/2000 31.22 Kb HTM 2497-v2.htm
to TRIAC Set Fuzzy Mode Turn off the power Set Non-fuzzy Mode Set Non-fuzzy Mode RETURN more sophisticated mode. A vacuum cleaner that is able to do the cleaning based on different represents the first and most visible group of the next generation of consumer products based on a new describes a universal motor power control implemented on a standard microcontroller running software using designed based on a sample floor whereby cleaning on different floors depends largely on the user's
www.datasheetarchive.com/files/stmicroelectronics/stonline/books/ascii/docs/2497-v3.htm
STMicroelectronics 16/01/2001 31.83 Kb HTM 2497-v3.htm
Key Pressed? Output Max. Power to TRIAC Output Min. Power to TRIAC Set Fuzzy Mode Turn off the mode. A vacuum cleaner that is able to do the cleaning based on different characteristics of floor most visible group of the next generation of consumer products based on a new control-fuzzy logic. universal motor power control implemented on a standard microcontroller running software using the fuzzy cleaner, power control is designed based on a sample floor whereby cleaning on different floors depends
www.datasheetarchive.com/files/stmicroelectronics/stonline/books/ascii/docs/2497.htm
STMicroelectronics 02/04/1999 29.4 Kb HTM 2497.htm
Output Max. Power to TRIAC Output Min. Power to TRIAC Set Fuzzy Mode Turn off the power Set Non-fuzzy on different characteristics of floor surfaces will be very desired for today's market. This new based on a new control-fuzzy logic. Fuzzy logic is a relatively new technology that enables machines and do. This note describes a universal motor power control implemented on a standard microcontroller inputs simultaneously. In a conventional vacuum cleaner, power control is designed based on a sample
www.datasheetarchive.com/files/stmicroelectronics/stonline/books/ascii/an/2497.htm
STMicroelectronics 17/09/1999 31.27 Kb HTM 2497.htm
Pressed? Output Max. Power to TRIAC Output Min. Power to TRIAC Set Fuzzy Mode Turn off the mode. A vacuum cleaner that is able to do the cleaning based on different characteristics of floor most visible group of the next generation of consumer products based on a new control-fuzzy logic. universal motor power control implemented on a standard microcontroller running software using the fuzzy inputs simultaneously. In a conventional vacuum cleaner, power control is designed based on a sample
www.datasheetarchive.com/files/stmicroelectronics/stonline/books/ascii/docs/2497-v1.htm
STMicroelectronics 20/10/2000 31.94 Kb HTM 2497-v1.htm
constant torque region. w Ability to supply a rated current on a continuous basis at any frequency. operations, each inverter switch is on for 1805 and a total of three switches are on at any instant of time. writing sequentially on the 3 selected bits of the digital I/O port as shown in figure 6: t t t U V 2 6 4 (decimal) Fig. 6 - Digit sequency on ST52x301 parallel port The Timer high frequency PWM whose duty cycle is managed by the Triac counter register of the ST52x301 pin (24).
www.datasheetarchive.com/files/stmicroelectronics/stonline/books/ascii/docs/6416.htm
STMicroelectronics 20/10/2000 22.07 Kb HTM 6416.htm
rated current on a continuous basis at any frequency. Rectifier Inverter Motor AC line Filter DC step modulation) With square wave inverter operations, each inverter switch is on for 1805 and a total of three switches are on at any instant of time. The resulting voltage is shown in figure 4. Motor obtained by writing sequentially on the 3 selected bits of the digital I/O port as shown in figure 6: t t t 2 6 4 (decimal) Fig. 6 - Digit sequency on ST52x301 parallel port The Timer
www.datasheetarchive.com/files/stmicroelectronics/stonline/books/ascii/docs/6416-v1.htm
STMicroelectronics 02/04/1999 19.31 Kb HTM 6416-v1.htm