500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Top Results

Part Manufacturer Description Datasheet BUY
B57230V2103J260 TDK Epcos RESISTOR, TEMPERATURE DEPENDENT, NTC visit Digikey
B57230V2103F260 TDK Epcos RESISTOR, TEMPERATURE DEPENDENT, NTC visit Digikey
10-4 Signal Transformer Inc Power Transformer visit Digikey
12.8-4 Signal Transformer Inc Power Transformer visit Digikey
16-2 Signal Transformer Inc Power Transformer visit Digikey
24-1 Signal Transformer Inc Power Transformer visit Digikey

Transformer EN60742 230 v

Catalog Datasheet MFG & Type PDF Document Tags
Abstract: QXYRWHP 7RURLGDO7UDQVIRUPHU'DWD6KHHW 1RY Control Panel Transformer, 500VA Vprim Brown , No. Primary Full Load Vprim [V] Vsec [V] Rated Current No Load per Sec [A] Vsec [V] * 310-3152 SFB0500-230-12 230 12V -0- 12V 20.833 12.61V -0- 12.61V * 310-3196 SFB0500-230-24 230 24V -0- 24V 10.417 25.60V -0- 25.60V 310-3231 SFB0500-230-55 230 55V -0- 55V , the requirements of : EN60742 Class II, Non-Short-Circuit Proof EN60065 Class II (IEC65) EN60950 -
Original
SFB0500-400-12 VDE0551 Transformer EN60742 50/60H 250VA SFB0500-400-24 SFB0500-400-55 VDE0550
Abstract: No. Primary Full Load Vprim [V] Vsec [V] 310-3118 SFB0075-230-12 230 12V -0- 12V 3.125 13.40V -0- 13.40V 310-3168 SFB0075-230-24 230 24V -0- 24V 1.563 26.97V -0- 26.97V 310-3203 SFB0075-230-55 230 55V -0- 55V 0.682 61.74V -0- 61.74V 310-3253 , QXYRWHP 7RURLGDO7UDQVIRUPHU'DWD6KHHW 1RY Control Panel Transformer, 75VA Vprim Brown , output. Connection lead insulation. Rated Current No Load per Sec [A] Vsec [V] Class H (180 -
Original
SFB0075-400-12 SFB0075-400-24 6174V 2301-2 bs415 SFB0075-400-55 BS415 VDE0106 VDE0470
Abstract: . Primary Full Load Vprim [V] Vsec [V] 310-3124 SFB0160-230-12 230 12V -0- 12V 6.667 13.36V -0- 13.36V 310-3174 SFB0160-230-24 230 24V -0- 24V 3.333 26.71V -0- 26.71V 310-3219 SFB0160-230-55 230 55V -0- 55V 1.455 60.90V -0- 60.90V 310-3247 SFB0160 , QXYRWHP 7RURLGDO7UDQVIRUPHU'DWD6KHHW 1RY Control Panel Transformer, 160VA Vprim Brown , . Connection lead insulation. Rated Current No Load per Sec [A] Vsec [V] Class H (180°C) Class B (130 -
Original
SFB0160-400-24 Nuvotem Talema en60742* 80va transformer 12V 24V transformer SFB0160-400-12 SFB0160-400-55
Abstract: QXYRWHP 7RURLGDO7UDQVIRUPHU'DWD6KHHW 1RY Control Panel Transformer, 320VA Vprim Brown , No. Primary Full Load Vprim [V] Vsec [V] Rated Current No Load per Sec [A] Vsec [V] * 310-3146 SFB0320-230-12 230 12V -0- 12V 13.333 13.12V -0- 13.12V 310-3180 SFB0320-230-24 230 24V -0- 24V 6.667 25.95V -0- 25.95V 310-3225 SFB0320-230-55 230 55V -0- 55V , the requirements of : EN60742 Class II, Non-Short-Circuit Proof EN60065 Class II (IEC65) EN60950 -
Original
12v transformer 130 at16a SFB0320-400-12 SFB0320-400-24 SFB0320-400-55
Abstract: Models Voltage range Current range UCS 50 (current source) 30 V 0 - 50 mA â'¢ Input â'¢ Transformer : 230 / 115 V AC 48 - 62 Hz : Split bobbin, potted, safety transformer According to,VDE0551, EN60742 â'¢ Ripple + noise â'¢ Temperature coeff. â'¢ Stability â'¢ Test voltage Input / Output , -turn screwdriver adjustment : By external potmeter 10 kâ"¦ : By 0-5 V analog programming â'¢ Programming input , after 20 min warm up. : 10 MOhm : 33 kOhm : 3.3 kOhm : 0.33 kOhm : 10 Âus : 33 V +/- 5% : -20 DELTA Elektronika
Original
Delta Elektronika F10-3
Abstract: range Current range 5 U 5 (voltage source) 5 U 15 - 15 (voltage source) 5-6V 2 x 12 - 15 V 1A 0 - 200 mA Specifications â'¢ Input : 230 / 115 V AC 48 - 62 Hz â'¢ Transformer : Split bobbin, potted, safety transformer According to, VDE0551, EN60742 â'¢ Test voltage Input , 12 -15 V (also unequal voltage) It can be used in 4 different configurations. â'¢ Two isolated outputs, each â'¢ Outputs in parallel â'¢ Outputs in series â'¢ Outputs in series, dual : 12-15 V DELTA Elektronika
Original
EN55022B
Abstract: transformer used to 400VA 561-836 supply one of these units must have an accurate and stable output voltage , transformer the 50VA 578-474 regulation must be such that if one or more units fails Electronic the resultant , regulation on partial load. 4 C14093 Transformer selection and considerations Maintenance free range When selecting a transformer for use with low voltage lamps always run it at the maximum rating where Features possible, eg. 50W lamp use a 50VA transformer, for four 50W lamps use a 200VA transformer etc. l Conforms RS Components
Original
electronic transformer halogen 12v 50W Halogen lighting toroidal transformer 240v input 12v output transformer TOROIDAL transformer specification RS transformer 200va Class 130B transformer
Abstract: VA ratings. I V BLK Derated VA From To 30 60 100 160 230 330 500 20 50 75 120 175 250 400 , 230 230 230 Secondary Voltage (V) 9+9 12 + 12 15 + 15 18 + 18 22 + 22 25 + 25 30 + 30 9+9 12 + 12 15 + , custom design (see page 11 for custom transformer specification guidelines and request form). Some , mm / 6" (±5 mm / .2") stranded, PVC insulated. Double-insulated primary leads: UL1672 (105° C, 300 V). Secondary leads: UL3266 (125° C, 300 V) Clearance: allow 4 mm / .2" over mounting hardware Avel Lindberg
Original
Y236853 Y236854 Y236906 Y236954 Y236956 Y236103 Y236202 600VA UL506/CSA UL1411/CSA Y236803 Y236804 Y236807
Abstract: Printtransformatoren 40 Printtransformator VCM montierbar 5 VA bis 50 VA, PRI: 230 V PCB transformers PCB transformer VCM with mounting brackets 5 VA to 50 VA, PRI: 230 V Ausführung Prüfzeichen , Printtransformatoren Printtransformator VCM montierbar 5 VA bis 50 VA, PRI: 230 V PCB transformers PCB transformer , ; safety isolating transformer to VDE 0551, EN60742,IEC742 : acc. to table : between input and output , : acc, to table VDE = B,UL = class 105 230 V 50 Hz to 60 Hz acc. to table twin secondary windings for -
OCR Scan
vde 0551 en60742 transformer vde 0551 en60742 VDE 0551 t 60 e vde 0550 transformer vde 0551 VDE 0551 EN 60 742
Abstract: Range Transformer Specifications - 50VA Load (VA) 50 50 50 50 50 50 50 50 50 Secondary Voltage (V) 6+6 , Specifications - 230VA Load (VA) 230 230 230 230 230 230 230 230 230 Secondary Voltage (V) 12 + 12 15 + 15 18 + , Transformer Mounting Specifications Load (VA) 15, 30, 50 63, 80, 100, 120 160, 230, 330 500, 625, 800, 1000 , each transformer. Leads: 150 mm / 6" (±5 mm / .2") stranded, PVC insulated. Double-insulated primary leads: UL1672 (105º C, 300 V). Secondary leads: UL3266 (125º C, 300 V) Clearance: allow 4 mm / .2" over Avel Lindberg
Original
Y236808 Y236405 Y236901 Y236658 Y236806 Y236101 1000VA D4000
Abstract: FE Series - (Encapsulated) Single Primary - Toroidal Transformers A high quality range of fully encapsulated toroidal transformers with flying leads. Featuring a single primary winding rated at 230(V) 50/60Hz, and dual secondary windings. Secondary windings can be connected in series or parallel or used , with EN60742, EN60065 and EN60950. · 100% electrical and flash tested. Specifications VA , transformer via the external frame work. This would constitute a shorted turn and would cause irreparable Multicomp
Original
0-9V 1A Transformer specification transformer 0-12v 0-18v transformer toroidal transformer 8000 18v transformer 1a 0-12V
Abstract: FE Series - (Encapsulated) Single Primary - Toroidal Transformers A high quality range of fully encapsulated toroidal transformers with flying leads. Featuring a single primary winding rated at 230(V) 50/60Hz, and dual secondary windings. Secondary windings can be connected in series or parallel or used , with EN60742, EN60065 and EN60950. · 100% electrical and flash tested. Specifications VA , transformer via the external frame work. This would constitute a shorted turn and would cause irreparable Multicomp
Original
0-15v transformer ti0273 TI02 TI-027351 TI-027344 TI-027335
Abstract: Industrial Control Transformers Industrial control transformers are used to reduce supply voltages to 230 V , 208 V 0.6 1.0 1.5 2.0 3.5 4.0 5.0 4.0 6.0 8.0 12.0 12.0 20.0 30.0 230 V 0.6 1.0 , parallel: 240 V Group F series: 230 V parallel: 115 V Group I Series: 24 V parallel: 12 V Group J Series: 480 V & 240 V: 240 V & 120 V Group K Series: 240 V: 120 V Exception: 150 VA transformer TA , . Primary Fuse Sizing Chart VA 50 120 V 1.2 208 V 0.6 230 V 0.6 240 V 0.6 277 V 0.6 Acme Electric
Original
gould shawmut fuse WESTINGHOUSE ELECTRIC fuse siemens magnetic contactor Westinghouse Motor protection relay Joslyn Clark furnas contactors
Abstract: 8.65 6.16 8.65 8.65 8.48 8.65 AIM Series Autotransformer 115/220/230/240 V ac Ì Common input and , should have a PTRV of four times the secondary rms voltage. Full wave V out = 0.707 x secondary volts (due to centre tap). Voltage doubler V out = 1.414 x secondary volts x 2 (Note: C is usually = FC). Other circuits V out = 1.414 x secondary volts. Regulation = (Off load voltage-full load voltage) x 100 off load voltage 223882 35 Transformers Transformer Connections, Twin Primary RATING (VA) Style Element14 Catalog
Original
0-9v 500ma transformer EI30 transformer transformer 230v ac 230v to 6v step down transformer SIM300 RoHS BABT CR 0090 B66421U0250K187 B66421U0315K187 B66422W1010D001 B66422B2000X000 B66423GX187 B66424W1012D1
Abstract: 218-681-6674 · FAX: 218-681-3380 · www.digikey.com Hammond Part No. Toroidal Transformer H PC Mount , kV (IEC742, VDE055 & EN60742). Primaries and secondaries for parallel or series connection. Ambient , XY Total V/Sec t mm mm gr % °C Eff. % 1.6 39.6 x 39.6 x 18.5 35.56 82 29 , Range V/ 220V Sec t Eff. Fuse* VA % °C % mA · · · · UL 1585 Class 2 &3 - File #E96720 , regulated power supply transformer, 5VDC and ±12VDC. Contact Digi-Key for an application note. FLAT DigiKey Electronics Catalog
Original
pt1017 mt 1389 vde SMD Code 12W SOT-23 600w 12V 230V Inverter schematic mw 137 600g PT1000 NTC TEMPERATURE CHART MK-6000CA-ND MK-9000CA-ND MK260CA-ND J100-KIT-ND J200-KIT-ND 1600-KIT-ND
Abstract: supplies batteries mains electrical 216 221 230 ordering and index today's solution for tomorrow , stated by the formula: V = I x R where V is the applied voltage I is the current in Amps R is the , V x I where P is in Watts V is in Volts I is in Amps Note: RMS values of V & I must be used for alternating current circuits. This can be combined with Ohm's law to yield: P = I 2 x R or P = V 2/R Where R is Ohms For an AC circuit containing non-resistive components: P = V x I x PF Where PF is the Power Maplin Catalog
Original
induction cooker fault finding diagrams enamelled copper wire swg table AC digital voltmeter using 7107 db 3202 diac siemens mkl capacitor YY63T