500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Top Results

Part Manufacturer Description Datasheet BUY
CLA60MT1200NTZ IXYS Corporation TRIAC visit Digikey
BCR08DS-14AT13#B10 Renesas Electronics Corporation TRIAC visit Digikey
BCR16FM-14LJ#BB0 Renesas Electronics Corporation TRIAC visit Digikey
BCR5FM-12LB#BB0 Renesas Electronics Corporation TRIAC visit Digikey
BCR8CM-12LB#BB0 Renesas Electronics Corporation TRIAC visit Digikey
BCR3FM-12RB#BB0 Renesas Electronics Corporation TRIAC visit Digikey

TRIAC BT 136

Catalog Datasheet MFG & Type PDF Document Tags
Abstract: ) max- BT 136- -500 600 700 800 max. 500 600 700 800 'tsm 'tsm max. max. 25 30 V A A MECHANICAL DATA Fig , will not trigger any device; Tj = 120 °C; gate open circuit BT 136 series dVD/dt < 100 V/fis BT 136 series G dVD/dt < 200 V/jis BT 136 series F dVD/dt < 50 V/m s BT136 series E dVD/dt typ. 50 V , current {!(.) Latching current (![_); Vq = 12 V T2+ G+ BT136 series BT 136 series G BT136 series F BT136 , . ^Although not recommended, off-state voltages up to 800 V may be applied without damage, but the triac may -
OCR Scan
BTi36 triac BT 06 400 triac BT 06 600 BT 136 TRIAC TRIAC BY 136 triac BT 06 700 220AB M1625 BT136F
Abstract: current (l|_j) Latching current (l[_); Vq = 12 V T2+ G+ BT136 series BT 136 series G BT136 series F BT 136 series E BT 136â'"500D/600D GT > 35 H < 15 L 50 H < 30 L 25 < 15 < 20 GT H L > 10 , - *Although not recommended, off-state voltages up to 800 V may be applied without damage, but the triac may , temperature of the terminals does not exceed 125 °C. During these overload conditions the triac may lose , based on sinusoidal currents (f = 50 Hz); Tj = 120 °C prior to surge. The triac may temporarily lose -
OCR Scan
BT136-500 BT136G triac tag 87 working triac bt136 triac bt 135 TRIAC BT 136-500D TO220 D8384 bt136 triac BT136- M1644 D8573
Abstract: V T2+ G+ BT136 series BT 136 series G BT136 series F BT 136 series E BT 136â'"500D/600D GT , - *Although not recommended, off-state voltages up to 800 V may be applied without damage, but the triac may , the temperature of the terminals does not exceed 125 °C. During these overload conditions the triac , . on-state current based on sinusoidal currents (f = 50 Hz); Tj = 120 °C prior to surge. The triac may , IPHIN M 1 643 Fig.8 Typical commutation dV/dt for BT136 series versus Tj. The triac should commutate -
OCR Scan
temperature control by triac BT136 TRIAC TAG 90 BT136 motor BT136 application note TRIAC bt136 Triac cross reference bt136 M81-1647/12
Abstract: T2+ G+ BT136 series bt 136 series G BT136 series F BT136 series E BT136â'"500D/600D GT H L , System (IEC 134). Voltages (in either direction) BT 136-5 00 600 700 800 Non-repetitive peak , triac may switch into the on-state. The rate of rise of on-state current should not exceed 3 A//vs , the triac may lose control. Therefore the overload should be terminated by a separate protection , -
OCR Scan
TRIAC bt136 500d of TRIAC BT136 triac bt136 characteristics lighting control by triac BT136 BT136-500D Triac bt136 600d D027173 MSA060 T0-220 G027174 GD271 D0E71
Abstract: -d lcom/d t = 1,8A/ms; 'T(RM S) = 4 a ; T mb = 85 °C ; gate open c irc u it; V q = v DWMmax BT 136 , , off-state voltages up to 800 V may be applied w ith ou t damage, but the triac may switch into the on-state , 10 10 15 BT136 series G BT136 series F BT136 series E BT 136-500D/600D , conditions the triac may lose control. Therefore the overload should be terminated by a separate protection , rior to surge. The triac may tem porarily lose control follow ing the surge. *TSM Fig,7 O n-state -
OCR Scan
triac bt 12 TAG 69 triac BT136 AN BT13 s41h BT136 Series E 711D02
Abstract: 1 BT 136 - ser les = â'" M 1 ''Hit , may be applied without damage, but the triac may switch into the on-state. The rate of rise of , Manufacturer N AMER PHILIPS/DISCRETE bTE ]> â  ^53^31 0027108 7^7 HAPX MOUNTING INSTRUCTIONS 1. The triac , the triac may lose control. Therefore the overload should be terminated by a separate protection , sinusoidal currents (f = 50 Hz); Tj = 120 °C prior to surge. The triac may temporarily lose control -
OCR Scan
UBC667 TRIAC BT 127 bt 13 g triac BT 80 GT35 DS614 DDB7111 S3T31 MLA863 0D271
Abstract: Information Scheme (BTA and BTB series) BT A 12 - 600 BW RG Triac series Insulation A = insulated B = , or surface-mount packages, the BTA12, BTB12 and T12 triac series is suitable for general purpose AC , 12 35 - 600 G (-TR) Triac series Current 12 = 12A Sensitivity 35 = 35mA 05 = 5mA Voltage 600 , 1.25 0.45 0.60 0.017 1.21 1.36 0.047 0.054 8.95 9.35 0.352 0.368 10.00 , 1.25 1.40 0.049 0.055 0.45 0.60 0.018 1.21 1.36 0.048 8.95 9.35 0.352 2.44 2.64 0.096 10.00 STMicroelectronics
Original
triac bta12 triggering BTA12 600V bta12 speed control application Triac BTB12 600 B BTA12 interface with ac motor bta12 phase control application 2500VRMS E81734 T12-R T12-G BTA12- BTB12-
Abstract: or surface-mount packages, the BTA12, BTB12 and T12 triac series is suitable for general purpose AC , BTA12, BTB12 and T12 Series Figure 13: Ordering Information Scheme (BTA and BTB series) BT A 12 - 600 BW RG Triac series Insulation A = insulated B = non insulated Current 12 = 12A Voltage 600 , Figure 14: Ordering Information Scheme (T12 series) T 12 35 - 600 G (-TR) Triac series Current 12 = , 0.037 1.25 0.45 0.60 0.017 1.21 1.36 0.047 0.054 8.95 9.35 0.352 0.368 10.00 STMicroelectronics
Original
triacs bt 12 600v BT 130 triac bta12 triac motor TRIAC BTB 16 600 tube TRIAC BTB12 600 TRIAC BTB 16 600 BW
Abstract: logic-level triac (for example, BT 136/600 D). The gate of this triac is decoupled with a 220nF/16V capacitor , . Therefore, wide firing-angle limits could result in an incorrect triac ignition. XTAL1 C R XTAL2 , ranging from ­0.7V to +0.7V. A low pass filter is required to filter voltage drops (generally after triac , , there are two external diodes for maximum port protection. The triac is ignited in the T2+G­ and T2­G­ quadrants. It is important that the Triac Terminal 1 is connected to a negative ground (GND=N). Note: The ZiLOG
Original
triac BT 408 DIMMER BT136 600 SCHEMATIC dimmer conrad DIMMER BT136 Zilog dimmer Z86E02 AN001700-Z8X0299
Abstract: Ignition capability of the Z86E02 MCU requires a logic-level triac (for example, BT 136/600 D). The gate of this triac is decoupled with a 220nF/16V capacitor, and the gate current is limited by a 1k , firing-angle limits could result in an incorrect triac ignition. Figure 4. RC Oscillator XTAL1 C R VSS , +0.7V. A low pass filter is required to filter voltage drops (generally after triac ignition). , protection. The triac is AN001701-Z8X0400 Application Note Dimmer Using the Z8 Microcontroller 5 ZiLOG
Original
ac load dimmer with microcontroller SCHEMATIC simple dimmer 230v light dimmer zero crossing dimmer ir dimmer circuits bt136 phase control application
Abstract: Series Figure 13: Ordering Information Scheme (BTA08 and BTB08 series) BT A 08 - 600 BW (RG) Triac , either in through-hole or surface-mount packages, the BTA08, BTB08 and T8 triac series is suitable for , Information Scheme (T8 series) T 8 10 - 600 B (-TR) Triac series Current 8 = 8A Sensitivity 10 = 10mA , A2 R C B G A2 1.25 0.45 0.60 0.017 1.21 1.36 0.047 0.054 D 8.95 STMicroelectronics
Original
TRIAC BTB08 specifications BTA08 ST TRIAC BTA 28 TRIAC BTB08 BTA54 triac bta08 BTA08- BTB08-
Abstract: information scheme (BTA16 and BTB16 series) BT A 16 - 600 BW RG TRIAC series Insulation A = insulated B = , BTA16, BTB16 T1610, T1635 16 A SnubberlessTM, logic level and standard Triacs Features A2 Medium current Triac Low thermal resistance with clip bonding Low thermal resistance , ) TRIAC series Current 16 = 16 A Sensitivity 10 = 10 mA 35 = 35 mA Voltage 600 = 600 V 800 = 800 V , 1.21 1.36 0.047 0.054 D 8.95 9.35 0.352 0.368 E 10.00 10.28 0.393 STMicroelectronics
Original
T1610G ac motor triac bta16 BTA16 Application note triac BT 16 rating TRIAC BTB16 specifications ST BTB16 UL1557 2002/95/EC T1635G
Abstract: information scheme (BTA16 and BTB16 series) BT A 16 - 600 BW RG TRIAC series Insulation A = insulated B = , BTA16, BTB16 T1610, T1635 16 A SnubberlessTM, logic level and standard Triacs Features A2 Medium current Triac Low thermal resistance with clip bonding Low thermal resistance , ) TRIAC series Current 16 = 16 A Sensitivity 10 = 10 mA 35 = 35 mA Voltage 600 = 600 V 800 = 800 V , 1.21 1.36 0.047 0.054 D 8.95 9.35 0.352 0.368 E 10.00 10.28 0.393 STMicroelectronics
Original
BTA 50 800 triac bta16 applications TRIAC BTA-SERIES triac btb16
Abstract: surface-mount packages, the BTA/BTB12 and T12 triac series is suitable for general purpose AC switching. They , BTA/BTB12-xxxBW BTB: non insulated TO-220AB package ORDERING INFORMATION BT A 12 - 600 BW (RG) TRIAC SERIES INSULATION: A: insulated B: non insulated SENSITIVITY & TYPE B , : Tube (-TR) TRIAC SERIES PACKAGE: G: D2PAK CURRENT: 12A VOLTAGE: 600: 600V 800: 800V , . 0.169 0.181 0.098 0.106 0.001 0.009 0.027 0.037 0.048 0.055 0.60 0.017 0.024 1.36 0.047 STMicroelectronics
Original
Abstract: ORDERING INFORMATION BT A 12 TRIAC SERIES INSULATION: A: insulated B: non insulated CURRENT: 12A 600 , DESCRIPTION Available either in through-hole or surface-mount packages, the BTA/BTB12 and T12 triac series is , : 10mA LOGIC LEVEL VOLTAGE: 600: 600V 800: 800V T 12 35 TRIAC SERIES CURRENT: 12A - 600 G , 0.60 0.017 0.024 1.36 0.047 0.054 9.35 0.352 0.368 10.28 0.393 0.405 5.28 0.192 0.208 15.85 0.590 0.624 STMicroelectronics
Original
BT 126 TRIAC triac BTA 32 600 bt 1690 triac BTA12 triacs bt 12 800v PAK/TO-220AB
Abstract: 3/10 BTA/BTB08 and T8 Series ORDERING INFORMATION BT A 08 - 600 BW TRIAC SERIES , DESCRIPTION Available either in through-hole or surface-mount packages, the BTA/BTB08 and T8 triac series is , 800: 800V CURRENT: 8A T 8 10 - 600 B (-TR) TRIAC SERIES CURRENT: 8A , 0.037 0.048 0.055 0.60 0.017 0.024 1.36 0.047 0.054 9.35 0.352 0.368 10.28 0.393 0.405 5.28 STMicroelectronics
Original
TRIAC BTa 18 600 BW triac BT 140 BTB108-xxxBW TRIAC BTA series TRIAC BTa 18 600 B triac BTA 140
Abstract: Scheme (BTA16 and BTB16 series) BT A 16 - 600 BW RG Triac series Insulation A = insulated B = non , through-hole or surface-mount packages, the BTA16, BTB16 and T16 triac series is suitable for general purpose , ) Triac series Current 16 = 16A Sensitivity 35 = 35mA Voltage 600 = 600V 800 = 800V Package G = , 1.36 0.047 0.054 D 8.95 9.35 0.352 0.368 10.00 10.28 0.393 0.405 G B2 STMicroelectronics
Original
triacs bt 16 600v triac bt 160 600v triacs bt 16a 600v BTB16-XXXBW TRIAC BTB16 600 BTA16 motor control T16-G BTA16- BTB16-
Abstract: surface-mount packages, the BTA/BTB16 and T16 triac series is suitable for general purpose AC switching. They , Part Number 600 V 800 V BTA/BTB16-xxxB X BTA/BTB16-xxxBW ORDERING INFORMATION BT A 16 - 600 BW TRIAC SERIES SENSITIVITY & TYPE B: 50mA STANDARD BW: 50mA SNUBBERLESS C , : 16A T 16 35 - 600 G (-TR) TRIAC SERIES PACKAGE: G: D2PAK CURRENT: 16A VOLTAGE , 0.055 0.60 0.017 0.024 1.36 0.047 0.054 9.35 0.352 0.368 10.28 0.393 0.405 5.28 0.192 0.208 STMicroelectronics
Original
TRIAC BTa 12 600 circuit triac btb16 TRIAC BTB 08 BTA 18 800 TRIAC BTA 70 IT-180
Abstract: INFORMATION BT A 24 - (RG) TRIAC SERIES INSULATION: A: insulated B: non insulated VOLTAGE , either in through-hole of surface and T25 mount packages, the BTA/BTB24-25-26 triac series is suitable , in TOP3 3/9 BTA/BTB24, BTA25, BTA26 and T25 Series T 25 35 - 600 G (-TR) TRIAC , 1.36 0.047 9.35 0.352 10.28 0.393 5.28 0.192 15.85 0.590 1.40 0.050 1.75 0.055 0.40 0° Typ STMicroelectronics
Original
TRIAC BTB T25 ac motor triac bta25 triac bt 151 triac TOP3 25a 800V triac bt 24 600v RD91 triac BTB24 BTA24
Abstract: power setting for the load is controlled by a logiclevel triac (for example, BT 136/800 E). The gate of the triac is decoupled with a 220nF/16V capacitor, and the gate current is limited by a 1k¾ resistor , triac is ignited in the T2+G­ and T2­G­ quadrants. It is important that the triac terminal 1 is , mandatory time count to ignite the triac on the correct phase angle. A lower value for variable phase_angle , timer1irq_count=0 timer1irq_count= timer1irq_count +1 Ignite triac Yes Correct phase angle? No ZiLOG
Original
50HZ oscillator sinus BT136 testing BT136 SCHEMATIC CIRCUIT z8 microcontroller sample programs 50hz to 60hz converter circuit diagram on z-ram X86XXX Z86C02/E02/L02 AN001600-Z8X0299
Showing first 20 results.