NEW DATABASE - 350 MILLION DATASHEETS FROM 8500 MANUFACTURERS

Datasheet Archive - Datasheet Search Engine

 

Catalog Search Results

Catalog Datasheet Results Type PDF Document Tags
Abstract: INTEGRATED CIRCUITS AN126 AN126 Applications using the SG3524 SG3524 1987 Feb Philips Semiconductors Philips Semiconductors Application note Applications using the SG3524 SG3524 AN126 AN126 EC35 (3C8) pair , the primary so that the pulse width will be reduced should transformer saturation occur. SG3524 SG3524 , BUZ41A BUZ41A Power FETs in the primary side of the step-down transformer at a 50kHz rate. (The main oscillator operates at 100kHz.) The transformer consists of 120T of #24 wire center-tapped at 60T. This is ... Original
datasheet

3 pages,
31.66 Kb

EC35 AN126 sg3524 push-pull converter design Ferroxcube 3C8 flyback TRANSFORMER EC35 sg3524 flyback off-line flyback regulator 100w Ferroxcube 3C8 sg3524 application flyback transformer philips sg3524 applications transformer 50KHz 100W sg3524 boost AN126 SG3524 AN126 abstract
datasheet frame
Abstract: Transformer Design Example It is determined to use a Philips EC35-3C8 core set and to add the necessary gap , demand. With the current mode supply the energy supplied to the inductor or transformer primary (which , the transformer. A ceramic Pin 4: Timing network, RTCT. An R/C network is connected between VREF , fixed voltage feed is used without a low current start-up and bootstrap supply from the transformer , supplied from a source separate from the output transformer, will not sense low supply conditions at the ... Original
datasheet

7 pages,
75.9 Kb

uc3842 application UC3842 constant power EC35 switching power uc3842 25V 4700uf flyback uc3842 application note uc3842 constant current uc3842 application circuit UC3842 smps design boost uc3842 application note flyback uc3842 flyback uc3842 power supply AN1272 UC3842 AN1272 abstract
datasheet frame
Abstract: Transformers OFF-LINE Switch Mode APPLICATION NOTES Power throughput of different transformer types operating at 100KHz switching frequency. POWER RANGE (W) Transformer TYPE , PQ3535 PQ3535 PQ4040 PQ4040 EC35 EC41 S . M . P . S . Transformers EER 50 ~ 100 100 ~ 200 200 ~ 500 , of simple regulation circuit. 5. Collector current reduced by turn ratio of transformer , Large transformer core with air gap may restrict applications. Average radio interference. 6. ... Original
datasheet

13 pages,
912.14 Kb

EE65 EI40 transformer ee55 core transformer ETD34 pq3230 EF32 TRANSFORMER EE42 core EE16 core transformer POT3019 EF20 TRANSFORMER Transformer ee19 EC35 TRANSFORMER flyback transformer tv HIGH FREQUENCY Transformer ee19 datasheet abstract
datasheet frame
Abstract: Load Regulation 4/6 APPLICATION NOTE APPENDIX POWER TRANSFORMER - T1 Core : Ferroxcube EC-35 , time of Q1, energy is stored in the air gap of transformer (inductor) T1. At this time the polarity of , When this level is reached, Q1 is turned off and the polarity of all transformer windings reverses , TRANSFORMER CONSTRUCTION 5/6 APPLICATION NOTE Information furnished is believed to be accurate and ... Original
datasheet

6 pages,
70.07 Kb

UC1842 flyback transformer diagram Capacitor ec-35 EC35 switching power EC35 TRANSFORMER HIGH FREQUENCY Transformer ec35 Ferroxcube 3C8 SGSP369 95VAC 130VAC 117VAC AN247/1188 UC1842 abstract
datasheet frame
Abstract: Load Regulation 4/6 APPLICATION NOTE APPENDIX POWER TRANSFORMER - T1 Core : Ferroxcube EC-35 , time of Q1, energy is stored in the air gap of transformer (inductor) T1. At this time the polarity of , When this level is reached, Q1 is turned off and the polarity of all transformer windings reverses , TRANSFORMER CONSTRUCTION 5/6 APPLICATION NOTE Information furnished is believed to be accurate and ... Original
datasheet

6 pages,
381.92 Kb

UC1842 TRANSFORMER EC35 HIGH FREQUENCY Transformer ec35 ferroxcube toroid core 3c8 Ferroxcube 3C8 SGSP369 EC35 TRANSFORMER 95VAC 130VAC 117VAC AN247/1188 UC1842 abstract
datasheet frame
Abstract: ) Transformer Model Number: SNX-2468-1 SNX-2468-1 EC35 2 Np 13 N s2 12 N s1 10 6 9 Figure 30. , gate-drive circuit IC. 2 CTR This is the drain of the low-side MOSFET. Typically, a transformer is , triggered. This protection is used when auxiliary winding of the transformer to supply VCC to the , problems may occur due to the radiated noise from main transformer, the inequality of the secondary-side leakage inductances of main transformer, and so on. Among them, it is one of the dominant reasons that ... Original
datasheet

17 pages,
1009.85 Kb

TRANSISTOR c104 EER-3542 EER3542 FAN7621BSJ FAN7621BSJX HIGH FREQUENCY Transformer ec35 KA431 SCR C103 EC35 bobbin an4151 FAN7621B FAN7621 EC35 TRANSFORMER SNX-2468-1 FAN7621B abstract
datasheet frame
Abstract: (Ae=106 mm ) Bobbin: EC35 (Horizontal) Transformer Model Number: SNX-2468-1 SNX-2468-1 EC35 2 Np 13 N s2 , circuit IC. 2 CTR This is the drain of the low-side MOSFET. Typically, a transformer is connected , radiated noise from main transformer, the inequality of the secondary-side leakage inductances of main transformer, and so on. Among them, it is one of the dominant reasons that the control , 23V, OVP is triggered. This protection is used when auxiliary winding of the transformer to supply ... Original
datasheet

17 pages,
625.46 Kb

SNX-2468-1 FAN7621SJ FAN7621SJX KA431 LLC resonant converter application note AN4151 FAN7621N opto-coupler scr FAN7621 HIGH FREQUENCY Transformer ec35 EC35 TRANSFORMER FAN7621 abstract
datasheet frame
Abstract: the transformer or inductor. Data sheet curves for the EC-35 core with 3C81 material recommend a 60 , converters delivering less than 150 W. It is inexpensive since © MOTOROLA INC. 1991 the transformer itself , outputs merely requires the addition of another secondary winding on the power transformer, a diode, and , advantage of the half bridge is that it transfers energy using the transformer core in the first and the , transformer turns ratio, current in the power transistor during its off time is zero, and the power ... OCR Scan
datasheet

12 pages,
597.88 Kb

WIMA MKS-3 PQ32-30 two transistor forward EC35 TRANSFORMER uc3844 smps power supply uc3844 transformer uc3845 flyback uc3845 half bridge an1108/d uc3844 substitution number AN1108 TDK RM6 WIMA MKS 3 AN1108/D AN1108 AN1108/D abstract
datasheet frame
Abstract: and adequate dynamic regulation, and provides guidelines for transformer design and component , For output power levels less than ~150W, the design of the power transformer (coupled inductor) is , In particular, only one magnetic element (i.e., the transformer) is employed as no inductors are used , compares primary and secondary current and transformer energy storage waveforms for these two cases. 1. a , Transformer Figure 2. Discontinuous vs Continuous Flyback Waveforms For the present design, a discontinuous ... OCR Scan
datasheet

21 pages,
755.92 Kb

flyback transformer construction EC35 crt flyback transformer 600W TRANSISTOR 40khz LG flyback 5B2 bridge rectifier ic Ferroxcube 3C8 flyback UC3840 Flyback transformer design and ratings unitrode PWM ferroxcube Ee core Ferroxcube 3C8 UC3840 abstract
datasheet frame
Abstract: value. To obtain a large leakage inductance, sectional winding method is used. Core: EC35 (Ae=106 mm2) Bobbin: EC35 (Horizontal) Transformer Model Number: SNX-2468-1 SNX-2468-1 Figure 30. Transformer Construction , circuit IC. 10 VCTR This is the drain of the low-side MOSFET. Typically, a transformer is , the transformer to supply VCC to FPSTM is utilized. 6.7 Thermal Shutdown (TSD): The MOSFETs and , from main transformer, the inequality of the secondary side leakage inductances of main transformer ... Original
datasheet

16 pages,
866.55 Kb

zero-voltage-switching EC35 bobbin fairchild Resonant IC KA431 lm 2468 TDA 200W AN-4151 EC35 TRANSFORMER FSFR2100 SNX-2468-1 FSFR2100 abstract
datasheet frame

Extended Electronics Archive (Experimental)

Abstract Saved from Date Saved File Size Type Download
Over 1.1 million files (1986-2013): html articles, reference designs, gerber files, chemical content, spice models, programs, code, pricing, images, circuits, parametric data, RoHS data, cross references, pcns, military data, and more. Please note that due to their age, these files do not always format correctly in modern browsers. Disclaimer.
 
Load Regulation + 3.5 % + 2.3 % + 2.4 % APPLICATION NOTE 4/6 APPENDIX POWER TRANSFORMER - T1 Core : Ferroxcube EC-35/3C8 Gap : 0.25mm. in each outer leg Note : For reduced EMI put gap in center leg only. Use 0.5mm. TRANSFORMER CONSTRUCTION APPLICATION NOTE 5/6 Information furnished is believed to be accurate , energy is stored in the air gap of transformer (inductor) T1. At this time the po- larity of the output reached, Q1 is turned off and the polarity of all transformer windings reverses, for- ward biasing the
www.datasheetarchive.com/files/stmicroelectronics/stonline/books/ascii/docs/1688-v1.htm
STMicroelectronics 02/04/1999 6.99 Kb HTM 1688-v1.htm
Load Regulation + 3.5 % + 2.3 % + 2.4 % APPLICATION NOTE 4/6 APPENDIX POWER TRANSFORMER - T1 Core : Ferroxcube EC-35/3C8 Gap : 0.25mm. in each outer leg Note : For reduced EMI put gap in center leg only. Use 0.5mm. TRANSFORMER CONSTRUCTION APPLICATION NOTE 5/6 Information furnished is believed to be accurate , energy is stored in the air gap of transformer (inductor) T1. At this time the po- larity of the output reached, Q1 is turned off and the polarity of all transformer windings reverses, for- ward biasing the
www.datasheetarchive.com/files/stmicroelectronics/stonline/books/ascii/docs/1688-v2.htm
STMicroelectronics 14/06/1999 6.96 Kb HTM 1688-v2.htm
.5 % + 2.3 % + 2.4 % APPLICATION NOTE 4/6 APPENDIX POWER TRANSFORMER - T1 Core : Ferroxcube EC-35/3C Q1. During the on time of Q1, energy is stored in the air gap of transformer (inductor) T1. At transformer windings reverses, for- ward biasing the output rectifiers. All the energy stored is now . TRANSFORMER CONSTRUCTION APPLICATION NOTE 5/6 Information furnished is believed to be accurate and
www.datasheetarchive.com/files/stmicroelectronics/stonline/books/ascii/docs/1688.htm
STMicroelectronics 20/10/2000 9.03 Kb HTM 1688.htm
Regulation + 3.5 % + 2.3 % + 2.4 % APPLICATION NOTE 4/6 APPENDIX POWER TRANSFORMER - T1 Core : Ferroxcube EC-35/3C8 Gap : 0.25mm. in each outer leg Note : For reduced EMI put gap in center leg only. Use 0.5mm. TRANSFORMER CONSTRUCTION APPLICATION NOTE 5/6 Information . During the on time of Q1, energy is stored in the air gap of transformer (inductor) T1. At this time reference inside IC1. When this level is reached, Q1 is turned off and the polarity of all transformer
www.datasheetarchive.com/files/stmicroelectronics/stonline/books/ascii/docs/1688-v3.htm
STMicroelectronics 25/05/2000 8.78 Kb HTM 1688-v3.htm
Siemens EC 35/17/10 (B6633 B6633 B6633 B6633 & - G0500 G0500 G0500 G0500 - x 127) 40 2 x 0.8 mm. VOGT 250 m H Toroidal Coil, Part Number are more efficient than linear types so the transformer and heatsink can be smal - ler and cheaper thermal re - sistance of : R th heats. = 0.85C/W 85C/W 85C/W 85C/W and the transformer must supply a power of : P diss diode. It follows that the transformer must be roughly 30VA and the heatsink thermal resistance about the cost of the transformer and an impressive 80-90% on the cost of the heatsink. Considering also the
www.datasheetarchive.com/files/stmicroelectronics/stonline/books/ascii/docs/4269-v2.htm
STMicroelectronics 14/06/1999 66.05 Kb HTM 4269-v2.htm
Siemens EC 35/17/10 (B6633 B6633 B6633 B6633 & - G0500 G0500 G0500 G0500 - x 127) 40 2 x 0.8 mm. VOGT 250 m H Toroidal Coil, Part Number are more efficient than linear types so the transformer and heatsink can be smal - ler and cheaper thermal re - sistance of : R th heats. = 0.85C/W 85C/W 85C/W 85C/W and the transformer must supply a power of : P diss diode. It follows that the transformer must be roughly 30VA and the heatsink thermal resistance about the cost of the transformer and an impressive 80-90% on the cost of the heatsink. Considering also the
www.datasheetarchive.com/files/stmicroelectronics/stonline/books/ascii/docs/4269-v1.htm
STMicroelectronics 02/04/1999 66.09 Kb HTM 4269-v1.htm
) Core Type No Turns Wire Gauge Siemens EC 35/17/10 (B6633 B6633 B6633 B6633 & - G0500 G0500 G0500 G0500 - x 127) 40 2 x 0.8 mm the transformer and heatsink can be smal - ler and cheaper. But how much can you gain ? We can transformer must supply a power of : P diss = 14 x 4 = 56W It must therefore be dimensioned for : 56 ; the L296 itself and the recirculation diode. It follows that the transformer must be roughly 30VA - lator allows a saving of roughly 50% on the cost of the transformer and an impressive 80-90% on the
www.datasheetarchive.com/files/stmicroelectronics/stonline/books/ascii/docs/4269.htm
STMicroelectronics 20/10/2000 70.97 Kb HTM 4269.htm
) (continued) Core Type No Turns Wire Gauge Siemens EC 35/17/10 (B6633 B6633 B6633 B6633 & - G0500 G0500 G0500 G0500 - x efficient than linear types so the transformer and heatsink can be smal - ler and cheaper. But how much transformer must supply a power of : P diss = 14 x 4 = 56W It must therefore be dimensioned for in two elements ; the L296 itself and the recirculation diode. It follows that the transformer the L296 switching regu - lator allows a saving of roughly 50% on the cost of the transformer and
www.datasheetarchive.com/files/stmicroelectronics/stonline/books/ascii/docs/4269-v3.htm
STMicroelectronics 25/05/2000 67.91 Kb HTM 4269-v3.htm
d 902b8e313d865a58e8bc9335719301c55499d4aa47a * * Transformer d0d369bb7cc91199b03bfd1053b267c36186a3
www.datasheetarchive.com/download/86927205-919714ZC/slum240.zip (UCC25230.LIB)
Texas Instruments 08/11/2011 56.57 Kb ZIP slum240.zip
*$ENCRYPTED_LIB *$INTERFACE * * (C) Copyright Texas Instruments Incorporated 2007. All rights reserved. * * This Model is designed as an aid for customers of Texas Instruments. * No warranties, either expressed or implied, with respect to this Model * or its fitness for a particular purpose is claimed by Texas Instrum
www.datasheetarchive.com/download/72188377-919831ZC/slvj003b.zip (tps51124p_encr.lib)
Texas Instruments 06/08/2011 95.1 Kb ZIP slvj003b.zip