NEW DATABASE - 350 MILLION DATASHEETS FROM 8500 MANUFACTURERS
SV401 691HT STT04 HHT275 Z-20160 Z-20162 Z-20161 Z-20165 V11523 TH202 TH02/-102 - Datasheet Archive
Data Sheet 10/11 8.64 EN Temperature Transmitter, field mounted TH202/TH202-Ex HART programmable, Pt 100 (RTD), thermocouples,
FieldIT Data Sheet 10/11 8.64 EN Temperature Transmitter, field mounted TH202/TH202-Ex HART programmable, Pt 100 (RTD), thermocouples, electrical isolation Level 0: Information Input Resistance thermometer (2, 3, 4 wire circuit) Thermocouples Resistance remote signalling unit (0.5000 ) Voltages, mV (125.+1200 mV) Output 2 wire technique 4.20 mA, HART signal Electrical isolation (I/O) Measured error 0.1 K Customer-specific linearization 32 tie points Continuous sensor and self-monitoring Parameter saved permanently in EEPROM Monitoring of data integrety every 10 s Wire break monitoring in acc. with NAMUR NE 89 Substitution strategy in case of error (NE 43) Approvals for explosion protection Intrinsically safe II 2 (1) G EEx [ia] ib IIC T6, mount in zone 1 II 3 G EEx n A II T6, mount in zone 2 Pressure proof II 2 G EEx d IIC T6, mount in zone 1 Input functionality (absolute, differential, average value) EMC acc. to EN 50082-2 and NE 21 Parameterization Device Management Tool: SV401 SV401 (SMART VISION) Hand held terminals: 691HT 691HT, STT04 STT04, HHT275 HHT275 CoMeter (HART configurator/LC display) 5 years warranty Excellent long term stability Temperature linear output signal Enhanced self diagnostics Temperature Transmitter, field mounted TH202/TH202-Ex HART programmable, Pt 100 (RTD), thermocouples, electrical isolation 10/11 8.64 EN Technical data Sensor short-circuit < 5 (for RTD) Output Sensor break (temperature/resistance measurement 2, 3, 4 wire) Measuring range 0. 500 > 530 Measuring range 0.5000 > 5.3 k Output signal (temperature linear) 4.20 mA Sensor wire break monitoring in accordance with NAMUR NE 89 Sensor wire break detection 3 wire resistance measurement > 35 4 wire resistance measurement > 3.7 k Residual ripple (peak-to-peak) < 0.3 % Current consumption < 3.6 mA Input filter 50/60 Hz Maximum output current 23.6 mA Thermocouples Parameterizable current error signal Underranging 3.6 mA Overranging 22 mA Default value 3.6.23.6 mA Types B, E, J, K, L, N, R, S, T, U Damping t63 = 0.30 s Voltages 125 mV.+ 125 mV 125 mV.+1200 mV Input Minimum measuring span 2 mV/50 mV Resistance Resistance thermometer (IEC 751, JIS, SAMA) n · Pt 100/Ni 100 to Pt 1000/Ni 1000; Cu (n = 0.1, 0.2, 0.5, 1, 1.2, 2, 3.10) Min. measuring span 15 K/50 K Resistance 0.500 /0.5000 Min. measuring span 5 /50 Sensor wire break monitoring in accordance with NAMUR NE 89 Pulsed with 1 µA outside of the measuring interval Monitoring disconnectible Thermocouple measurement > 5 k Voltage measurement > 5 k Input filter 50/60 Hz Internal reference junction Pt 100, via software switchable (no jumper necessary) Maximum line resistance (Rw) per core 2, 3, 4 wire 7.5 , 10 , 50 Measuring current 300 µA Input element Standard Measuring range Min. measuring span Sensor IEC 584 1 Thermocouple type B Thermocouple type E Thermocouple type J Thermocouple type K Thermocouple type R Thermocouple type S Thermocouple type T Thermocouple type N 250.+1820 °C 250.+1000 °C 210.+1200 °C 250.+1372 °C 50.+1768 °C 50.+1768 °C 200.+ 400 °C 200.+1350 °C (+482.+3308 °F) (418.+1832 °F) (346.+2192 °F) (418.+2502 °F) ( 58.+3215 °F) ( 58.+3215 °F) (328.+ 752 °F) (328.+2462 °F) 235 °C 30 °C 37 °C 54 °C 171 °C 193 °C 50 °C 60 °C (423 °F) ( 54 °F) ( 67 °F) ( 98 °F) (308 °F) (348 °F) ( 90 °F) (108 °F) DIN 43710 Thermocouple type L Thermocouple type U 200.+ 900 °C ( 76.+ 482 °F) 200.+ 600 °C (328.+1112 °F) 36 °C 40 °C ( 65 °F) ( 72 °F) IEC 751; JIS; SAMA1) 2, 3 and 4 wire Resistance thermometer Pt 100 Resistance thermometer Pt 1000 200.+ 850 °C (328.+1562 °F) 200.+ 850 °C (328.+1562 °F) 15 °C 50 °C ( 28 °F) ( 90 °F) DIN 437602) 2, 3 and 4 wire Resistance thermometer Ni 100 Resistance thermometer Ni 500 60.+ 250 °C ( 76.+ 482 °F) 60.+ 250 °C ( 76.+ 482 °F) 8 °C 15 °C ( 15 °F) ( 28 °F) Resistance 0.500 /0.5000 5 /50 Voltage mV 125 mV.+ 125 mV 125 mV.+1200 mV 2 mV 50 mV 1) 2) 2 IEC 751 a = 0.00385, JIS a = 0.003916, SAMA a = 0.003902 Edison Curve No. 7 Temperature Transmitter, field mounted TH202/TH202-Ex HART programmable, Pt 100 (RTD), thermocouples, electrical isolation 10/11 8.64 EN Power supply (poling protected) Mechanical construction Supply voltage Non Ex application Us = 8.5.30 V DC For Ex Application, max. Ui = 8.5.29.4 V DC 2 wire methode: power supply wires = signal wires Dimensions Confer dimensional drawing Weight 1.25 kg (without accesories) Influence of supply voltage < 0.05 %/10 V Housing material Aluminium stainless steel maximum residual ripple 1 % US (< 500 Hz) Type of protection IP 67 Power demand of indicators (Power demand of transmitter and indicator have to be added) Digital indicator Usd = 2 V DC or with cable screw connections 2 x M20 x 1.5 (metal) Ground screw external/internal 6 mm2 M5 / 2.5 mm2 M4 ( U smax U smin ) R ( k ) = -23.6 Terminals, pluggable 2.5 mm2, screw terminals 910 Maximum permissible load R Electrical connection Thread (alternatively) 2 x M20 x 1.5, 2 x 1/2" GK, 2 x 1/2" NPT, 2 x 3/4" NPT CoMeter (HART configutor/LC display) Usd = 2.9 V DC Maximum load epoxy color (RAL 9002) 788 With CoMeter Characteristics at rated conditions According to IEC 770 (related to 25 °C)1) Digital measured error Pt 100 Thermocouples Linear resistance 500 /5000 Linear voltage 120 mV/1200 mV ge n n ra io 250 at er p (HC) O 0 8,5 11,4 14,4 17,3 Z-20160 Z-20160 V DC Power supply Us 30 ± 0.1 K ± 20 µV ± 40 m/200 m ± 20 µV/50 µV D/A measured error ± 0.05 % of measuring span Additional influence of the internal reference junction Pt 100 DIN IEC 751 Kl. B General characteristics Output signal refreshment rate Pt 100 0.4 s (Input signal change < 0.25 K/s) Thermocouples 0.2 s (Input signal change < 2.5 K/s) Vibration resistance Vibration in operation Resistance to shock Influences Influence of ambient temperature Pt 100/resistance measurement2) ME ( ) < ( 0.05 % + - × 0.008 % ) / 10 K MS ( ) 2g acc. to DIN IEC 68T.2 6 acc. to DIN IEC 68T.2 27 Thermocouple/mV3) Electrical isolation (I/O) 1.5 kV AC (60 s) ME ( mV ) 0.14 K < ( 0.05 % + - × 0.01 % + - × 100 % ) / 10 K MS ( mV ) MS ( K ) Long-term stability 0.1 % p.a. Percentage related to measuring span MS = ME MA MA = lower range value, ME = upper range value Environment conditions Ambient temperature range 40.85 °C Transport and storage temperature 40.100 °C Relative humidity < 100 % 1) Percentage related to set measuring span Specified values corresponds to 3 (Gaussian normal distribution) Pt 100 (0.400 °C): Influence of ambient temperature < (0.05 % + 0.013 %)/10 K = 0.063 %/10 K 3) Type K (0.1000 °C): Influence of ambient temperature < (0.05 % + 0.01 % + 0.014 %)/10 K = 0.074 %/10 K 2) Condensation Permitted 3 Temperature Transmitter, field mounted TH202/TH202-Ex HART programmable, Pt 100 (RTD), thermocouples, electrical isolation Explosion protection Electromagnetic compatibility (EMC) Pt 100: measuring range 0.100 °C, span 100 K Intrinsically safe Zone 1 Marking EC Type Examination certificate Temperature class T6/T5/T4 II 2 (1) G EEx [ia] ib IIC T6 PTB 99 ATEX 2139 X 50 °C/65 °C/85 °C Supply circuit Output [ib] Input [ia] Max. voltage Ui = 29.4 V Uo = 5.6 V Short circuit current Ii = 130 mA Io = 1.5 mA4) Max. power Pi = 0.8 W Po = 20 mW Internal inductance Li = 220 µH Lo = 1 mH Internal capacitance Ci = 15 nF Co = 1.55 µF Zone 2 Marking Conformity statement Temperature class T6/T5/T4 Type of test Burst to signal/ data lines Static discharge Contact plate (indirect) Terminals for supply6) Terminals for sensors6) Radiated field 80 MHz.1 GHz Coupling 150 kHz 80 MHz II 1 D EEx [ia] ib T 120 °C According to ATEX Pressure-proof enclosure II 2 G EEx d IIC T6 PTB ATEX 1144 X 50 °C/65 °C/85 °C Canadian Standards Association and Factory Mutual Nonincendive FM Explosionsproof FM/CSA 4) 5) 4 8 kV 6 kV 4 kV no influence no influence no influence 10 V/m < 1.0 % 10 V IEC 1000 4 4 < 1.0 % 1000 4 2 1000 4 3 1000 4 6 II 3 G EEx n A II T6 PTB 99 ATEX 2216 X 50 °C/65 °C/85 °C Zone 20: Non intrinsically safe type Marking II D 1 T 135 °C5) EC Type Examination certificate Acording to ATEX Marking EC Type Examination certificate Temperature class T6/T5/T4 Influence < 0.1 % In case of an input signal change > 0.25 K/s for Pt100 or > 2.5 K/s for thermocouples a measured value plausibility check is performed. Dust-explosionproof Zone 20: intrinsically safe type Marking EC Type Examination certificate Degree 3 kV According to NAMUR NE 21 recommendation. 6) Intrinsically Safe FM/CSA 10/11 8.64 EN Class I, Div. 1/Div. 2, Groups A, B, C, D Class II, Div. 1/Div. 2, Groups E, F, G Class III Class I, Zone 1, AEx [ia] ib IIC T6 Class I, Zone 1, Ex [ia] ib IIC T6 Class I, Div. 2, Groups A, B, C, D, T6 Class II, Div. 1/Div. 2, Groups F, G, T6 Class III T6 Class I, Div. 1/Div. 2, Groups A, B, C, D, T6 Class II, Div. 1/Div. 2, Groups E, F, G, T6 Class III T6 See 1. supplement PTB 99 ATEX 2139 X With this marking, a 63 mA fuse must be inserted in the 4.20 mA circuit before the transmitter Air discharge (at 1 mm distance) Temperature Transmitter, field mounted TH202/TH202-Ex HART programmable, Pt 100 (RTD), thermocouples, electrical isolation 10/11 8.64 EN Displays (option) Digital display CoMeter (HART configurator and LC display) Digital display Process value, sensor value or loop current value indicator Fed through current loop LC display: 3½ digits (± 1999), digit height 10 mm, 7 segments Standard scaling 0.100 % Linear scaling for measuring ranges and units possible Description of the physical unit (labels) CoMeter (HART configurator and LC display) 4 function keys for request and programming (Code protection) Fed through current loop LC display: 5 digits (± 1999), digit height 7,6 mm, 7 segments Sign and floating point 10 segment bargraph (heading of measuring range) 7 digits alphanumeric characters 6 mm, 14 segments Display Response time Measuring error Overvoltage or maximum current EMC Temperature Humidity Digital display CoMeter 0.5 s 1.3 s ± 0.1 % ± 0.15 % 150 % of 215 mA input range EN 50082 2 20.+70 °C 0.100 %, condensating permitted Mind limits of application Dual function HART transmitter programming unit (all HART functions except for freely configurable characteristic curve and TAG Number) Process value, sensor value or loop current value indicator Communication/parameterization Hand held terminal HHT 691HT 691HT, STT04 STT04, HHT275 HHT275 CoMeter Hart conigurator and LC display Request function Process variable, analog and display value, description of measuring point, serial number, error behaviour, lower/upper measuring range limit Device Management Tool SV401 SV401 (SMART VISION) Change function Sensor type,sensor circuit, measuring range, damping, mains filter, error signalling Parameter Sensor type, error signalling, measuring range, general characteristics (i. e. TAG number), damping, signal simulation of output Special function Zero point adjustment, simulation of output signal, adjustment of output signal, wet calibration Software interface AMS, Cornerstone CoMeter E NE PA S OU or Isolators Controller Recorders . (250 min.)* Line resistance HE RE EX PL O S IVE KE CU IGHT WHE N CIR T E NS ION E N AT M OS P ER US C Processinterface SO - + V R RI ABB +123.4 °C (optional) GND or 691HT 691HT, STT04 STT04, HHT275 HHT275 FSK Modem *if necessary Z-20162 Z-20162 L IV IT S A 5 EP Temperature Transmitter, field mounted TH202/TH202-Ex HART programmable, Pt 100 (RTD), thermocouples, electrical isolation 10/11 8.64 EN Connection diagram 1 1 1 1 3 + 3 3 3 3 4 + 4 K2 3 1 3 1 3 1 3 K1 K2 4 4 4 4 Reference junction 2 2 2 2 b) c) d) e) V DC 2 a) 2 4 V DC 4.20 mA 4 1 3 K1 Input Output 1 f) g) h) i) f) Thermocouple g) Double thermocouple (average value or differential temperature measurement) h) Voltage measurement i) Double voltage measurement (average value or differential temperature measurement) a) b) c) d) Resistance thermometer, 2 wire circuit Resistance thermometer, 3 wire circuit Resistance thermometer, 4 wire circuit Double resistance thermometer, 2 wire circuit (average value or differential temperature measurement) e) Potentiometer input, 4 wire circuit Dimensional diagram (Dimensions in mm) AGLFD housing 40 90 PA S OU US 72 HE V CO T E NS ION E N AT M OS P T WHE N C IRC M8 SO T IGH ER V R RI ABB +123.4 °C 40 NE E 97 L IV UI TS A RE EX PL O KE S IVE EP 48 ~20 38 27 125 Electrical connections 2" AGLF housing 90 11 L IV NE E PA S OU CU HE V CO T IGH ER T E NS ION E N AT M OS P 97 US T WHE N C IR SO RE I EX PL O KE S IVE EP 48 Electrical connections 6 Locksrew V R RI IT S A Thread Thread 115 Potential equalisation srew M5 Z-20161 Z-20161 Z-20165 Z-20165 + Us = 8,5.30 V DC - 1 Microprocessor Temperature Transmitter, field mounted TH202/TH202-Ex HART programmable, Pt 100 (RTD), thermocouples, electrical isolation 10/11 8.64 EN Ordering information Catalog No. TH202/TH202-Ex V11523 V11523(without expolsion protection) 1 TH202 TH202 With explosion protection: Type of protection: intrinsically safe PTB / ATEX II 2 (1) G EEx [ia] ib IIC T6 (Zone 1) 5 TH202-Ex FM / CSA Class I, Div. 1/Div. 2, Groups A, B, C, D 7 TH202-Ex Class II, Div. 1/ Div. 2, Groups E, F, G Class III Class I, Zone 1, AEx [ia] ib IIC T6 Class I, Zone 1, Ex [ia] ib IIC T6 II 3 G EEx n A II T6 (Zone 2) N TH202-Ex N PTB / ATEX Class I, Div. 2, Groups A, B, C, D T6 nonincendive M TH202-Ex N FM / CSA Class II, Div. 2, Groups F, G T6 Class III T6 (Zone 20) Type of protection: Dust-explosionproof ATEX II 1 D EEx [ia] ib T 120 °C (intrinsically safe type) S TH202-Ex ATEX II 1 D T 135 °C (Non intrinsically safe type) G TH202 TH202 Type of protection: Pressure-proof enclosure / explosionproof II 2 G EEx d IIC T6 D TH202-Ex d PTB / ATEX Class I, Div. 1/Div. 2, Groups A, B, C, D T6 E TH202-Ex d FM Class II, Div. 1/Div. 2, Groups E, F, G T6 Class III T6 Display / construction AGLF housing without display N AGLFD housing with digital indicator D AGLFD housing with Cometer C Aluminium A Material Stainless steel E Connections with cable screw connection 2 pieces M20 x 1,5 cable screw connection1) M 2 pieces pressure proof cable screw connection1) D Thread M20 x 1.5 1 (without cable screw connection) 1/2" NPT 2 3/4" NPT 3 1/2" GK 4 Mounting field housing without 1 Wall mounting (carbon steel) 2 Wall mounting (stainless steel) 3 2" Pipe mounting (carbon steel) 4 2" Pipe mounting (stainless steel) 5 Programming Factory standard parameter: S Pt 100, 4 wire circuit, damping off, direct action characteristic overranging at sensor or device error (22 mA) Customer-specified parameter definition K without 0 Certificates 2 point calibration certificate 1 9 point calibration certificate 2 EUR Deliv. time 3 wks. 413,70 * 441,00 * 441,00 * 441,00 * 441,00 * 441,00 * 441,00 * 441,00 * 441,00 * 160,70 * 209,00 * 125,00 * 32,20 * 40,20 * 16,10 29,50 32,20 51,00 * * * * - 21,50 * 75,60 * 107,10 * Accessories Catalog No. EUR Deliv. time ABB FSK modem [EEx ib] IIC (parameter setting in the installation) see Data Sheet 10/63-6.71 EN Device Management Tool SV401 SV401 (SMART VISION) see Data Sheet 10/63-1.20 EN TH02/-102 TH02/-102 /-202 driver for AMS software 1.4 (Rosemount)2) 7957771 107,10 * 1) Metal screw connection EEx e or EEx d (cable-diameter 3.5.8.7 mm) 2) already integrated in AMS software version 5.0 or higher Notice: For a lokal programming on the desk can used as Hardware the universal FSK-Programming-Set (without Parasoft) (see Data Sheet 10/63-6.71 EN: ordering information) . 7 The IndustrialIT wordmark and all mentioned product names in the form XXXXXXIT are registered or pending trademarks of ABB. The Company's policy is one of continuous product improvement and the right is reserved to modify the information contained herein without notice. ABB has Sales & Customer Support expertise in over 100 countries worldwide. Printed in the Fed. Rep. of Germany (10.02) © ABB 2002 ABB Ltd. Salterbeck Trading Estate Workington, Cumbria CA14 5DS UK Tel: +44 (0)1946 830 611 Fax: +44 (0)1946 832 661 10/11 8.64 EN Rev. A www.abb.com ABB Inc. 125 E. County Line Road Warminster, PA 18974 USA ABB Automation Products GmbH Borsigstr. 2 63755 Alzenau Germany Tel: +1 215 674 6000 Fax: +1 215 674 7183 Tel: +49 6023 92 0 Fax: +49 6023 92 3430