NEW DATABASE - 350 MILLION DATASHEETS FROM 8500 MANUFACTURERS

Datasheet Archive - Datasheet Search Engine

 

Direct from the Manufacturer

Part Manufacturer Description PDF Samples Ordering
VC10F16K Honeywell Sensing and Control VC Series, 16 kOhms, 10.0 W, Fixed, Wirewound Resistor ri Buy
15PA258 Honeywell Sensing and Control Toggle Switch Sealing Ring, Military procurement number M5423/16-01 ri Buy
510E1A48F416PB Honeywell Sensing and Control 510E Series mechanical encoder, 2-bit: 16 cycles per revolution, 16 detents per rev., PC type B-110 terminals ri Buy

Sprecher Schuh L2 16

Catalog Datasheet Results Type PDF Document Tags
Abstract: : Allan-Bradley/Sprecher + Schuh 0,1 - 0,16 - 0,25 - 0,4 - 0,63 - 1,0 - 1,6 - 2,5 - 4 6,3 - 9 0,16 0,25 0,4 0 , /µs 50 A/µs Funktionsdiagramm L1 L2 L3 Eine Überlastüberwachung ist nicht im Gerät eingebaut. L1 L2 L3 Uc 24-110 V ~ Der Motorstarter steuert zwei Phasen. Die dritte Phase liegt ständig an , Bild 2) Dies ist mit dem Elektronischen Motorstart RSE einfach zu erreichen: L1 L2 L3 L1 L3 C1 L1 1) Die Leistung zum Motor trennen und das RSE dazwischensetzen. L2 L3 C1 ... Original
datasheet

4 pages,
73.18 Kb

Telemecanique 660-GRB abb dc motor Sprecher Schuh KTA 3 Ferraz 660-GRB 10-25 3-25-Hersteller sprecher kta 25 RSE 40 Sprecher Schuh rse c1 sprecher kta 3-25 kta 3-25 sprecher IEC 947 2 datasheet abstract
datasheet frame
Abstract: Schuh 0.25 0.4 0.63 1 1.6 2.5 4 6.3 10 16 Motor controller type: 127 , controller is switching 2 lines. The 3rd line is continuously connected to the load. L2 U/ T1 Uc 110-480V A2 0 A1 U Operation Diagram 1 L2 V W Operation Diagram 2 Mains Ue , with the RSE soft-starting relay: L1 L2 L3 L1 L2 L3 C1 L1 L2 L3 C1 L1 L2 L3 A1 1) Cut the cable to the motor and insert the RSE relay. A2 A3 U/T1 2 ... Original
datasheet

4 pages,
97.04 Kb

ABB Softstart Sprecher Schuh KTA 3 Sprecher Schuh L2 16 3 phase Overload Telemecanique Ferraz 660-GRB 10-25 motor DC 48 VOLT 3 PHASE 3 phase 7.5 hp induction motor winding telemecanique overload overload protection of induction motor Telemecanique GV 2 Sprecher schuh kta Sprecher Schuh datasheet abstract
datasheet frame
Abstract: Series L2 Rotary Cam Switches Sprecher + Schuh's comprehensive line of L2 rotary cam , , Sprecher + Schuh maintains three different stocking levels of L2 switches: · Stock Items - All switch , your Sprecher + Schuh representative for publication no: Tech-LMSD K2 · Emergency OFF switches - , , but may require assembly before they are shipped. · Custom made switches Sprecher + Schuh can , , always consult with your Sprecher + Schuh representative to determine if a stock or standard switch is ... Original
datasheet

33 pages,
2092.89 Kb

LA2-G2853 LA2-20-CU Sprecher Schuh Sprecher Schuh LA-2-12 le2 20 LE2-20- Sprecher Schuh CT 4-9 Sprecher L2-12 LE2-20 Sprecher Schuh le2-25 LE2-16- Sprecher Schuh LE 2-25 Sprecher Schuh LE2-16 datasheet abstract
datasheet frame
Abstract: protection circuit breaker type KTA3-25Manufacturer : Allan Bradley/Sprecher + Schuh Motor controller type , , AVG 14 0.5 mm2, AWG 20 0.6 Nm 10 mm2, or 2 x 6 mm2 AWG 6 or 2 x AWG 10 1 mm2, AWG 16 2.0 Nm UL , (Contacts open). Functional Diagram L1 L2 L3 All dimensions in mm L1 L2 L3 Uc 110-480 V A3 , soft start is very simple with the RSE soft-starting relay: L1 L2 L3 L1 L2 C1 L1 L2 L3 Fusing Considerations The motor controller provides by-passing of the semiconductors ... Original
datasheet

4 pages,
305.32 Kb

telemecanique overload 15 KW motor KTA3 overload protection of induction motor Sprecher Schuh L2 16 RSE4025-C RSE4025-C10 relays telemecanique RSE Bradley telemecanique magnetic contactor ac induction motor of .25 HP Sprecher Schuh datasheet abstract
datasheet frame
Abstract: 0.16 Manufacturer: Allan-Bradley/Sprecher + Schuh 0.25 0.4 0.63 1 1.6 2.5 4 , is continuously connected to the load. L2 U/ T1 Uc 110-480V A2 0 A1 U Operation Diagram 1 L2 V W Operation Diagram 2 Mains Ue Motor voltage 1 100% 3 2 , Direct On Line start into a soft start is very simple with the RSE soft-starting relay: L1 L2 L3 L1 L2 L3 C1 L1 L2 L3 C1 L1 L2 L3 A1 1) Cut the cable to the ... Original
datasheet

4 pages,
97.05 Kb

overload protection of induction motor Sprecher sprecher kta 3-25 telemecanique relay telemecanique overload telemecanique limit switch 3 phase Overload Telemecanique Sprecher Schuh L2 16 relays telemecanique RSE telemecanique magnetic contactor kta 3-25 sprecher 3 phase squirrel cage induction motor datasheet abstract
datasheet frame
Abstract: Switches K1 Series L2 Rotary Cam Switches Sprecher + Schuh's comprehensive line of L2 rotary , configuration. For this reason, Sprecher + Schuh maintains three different stocking levels of L2 switches: · , switches and how to apply them, ask your Sprecher + Schuh representative for publication no: Tech-LMSD , Sprecher + Schuh can manufacture a full array of custom switches within reasonable time frames. Refer , ordering a custom switch, always consult with your Sprecher + Schuh representative to determine if a ... Original
datasheet

54 pages,
2589.85 Kb

LA2-G3393 Sprecher Schuh CT 3-23 AC-22A sprecher schuh le2-16 cam switch Sprecher Schuh le marking k52 LA2-G3394 Sprecher Schuh LE 2 Sprecher Schuh LE2-16 LA2-G2853 Sprecher Schuh L2-16 Sprecher Schuh le2-12 Sprecher Schuh LE2-20 datasheet abstract
datasheet frame
Abstract: 0.16 Manufacturer: Allan-Bradley/Sprecher + Schuh 0.25 0.4 0.63 1 1.6 2.5 4 , On Line start into a soft start is very simple with the RSE soft-starting relay: L1 L2 L3 L1 L2 L3 C1 L1 L2 L3 C1 L1 L2 L3 A1 1) Cut the cable to the motor , Contactor C1 is therefore needed as a service switch for the motor. I> L1 L2 L3 L1 L2 L3 I> L1 N L2 I> L3 S1 A1 ~ A2 A3 L1 L2 L3 L1 L2 U/T1 U/T2 W/T3 ... Original
datasheet

4 pages,
80.99 Kb

3-25-Manufacturer 3 phase squirrel cage induction motor sprecher kta 25 3 phase 7.5 hp induction motor winding telemecanique heaters Sprecher Schuh relays telemecanique RSE telemecanique limit switch telemecanique overload telemecanique magnetic contactor Ferraz 660-GRB datasheet abstract
datasheet frame
Abstract: 0.16 Manufacturer: Allan-Bradley/Sprecher + Schuh 0.25 0.4 0.63 1 1.6 2.5 4 , On Line start into a soft start is very simple with the RSE soft-starting relay: L1 L2 L3 L1 L2 L3 C1 L1 L2 L3 C1 L1 L2 L3 A1 1) Cut the cable to the motor , Contactor C1 is therefore needed as a service switch for the motor. I> L1 L2 L3 L1 L2 L3 I> L1 N L2 I> L3 S1 A1 ~ A2 A3 L1 L2 L3 L1 L2 U/T1 U/T2 W/T3 ... Original
datasheet

4 pages,
248.25 Kb

telemecanique overload telemecanique contactor Sprecher schuh kta sprecher kta 3-25 telemecanique overload relay kta 3-25 Sprecher Schuh sprecher schuh KTA 3-25 datasheet abstract
datasheet frame
Abstract: DIN-rail mounting All Sprecher + Schuh solid state relays come standard with an LED to indicate when , Application Notes Series SA Solid State Relays 3 Phase Solid State Relay Applications The Sprecher + Schuh , control All of Sprecher + Schuh's Series SAS(R) SSR's use high noise immunity circuitry in addition to , Series SAR(S) Solid State Relays Reliable performance for millions of operations Sprecher + Schuh's SAR(S) line of solid state relays are the ideal solution for applications where high speed ... Original
datasheet

21 pages,
571.65 Kb

SAS6-50-1D SAR6-25-1D 28V relay latching solid state relay application notes SSR schematics 20000 watt schematics power amp Sprecher 4-5 SAR6-75-1 Sprecher Schuh star delta SAR6-50-1D 28V 50A Relay 5 leg relay free datasheet abstract
datasheet frame
Abstract: Sprecher+ Schuh Type Ref. 100-ML09N3 100-ML09N3 CAV 4-9-10-ÊVË AC [A] 230 V 400 / 415 V 500 V 20 , load 3 Aux. cont. Allen-Bradley Cat. No. Sprecher+ Schuh Type Ref. [A] [HP] [FLA , 5.5 7.5 9 14.5 20 12 16 / 15 4 7 7 10 13 690 V ­ ­ 5 7 9.3 CAB6 / CA 6 , 10 - 13 - 15 - - 16 17 - - 60 Hz - 05 - 08 - 10 - - - 13 15 - - 16 17 - 54 55 - - - ... Original
datasheet

46 pages,
1084.57 Kb

100-C43 Allen-Bradley 100-C12 10 sprecher schuh KTA 3-25 allen bradley 100-c12 Sprecher Schuh CA 4-5C-10 sprecher and schuh ca 4-9 star delta wiring diagram motor start y PLC ELEVATOR CONTROL Allen-Bradley contactor 100 c12 100-C60 00 Allen-Bradley c09-10 allen bradley 100-c43 100-M 100-C 100-M abstract
datasheet frame