NEW DATABASE - 350 MILLION DATASHEETS FROM 8500 MANUFACTURERS
STM-16 OC-48 GR-253-CORE OC-12 I-16/SR-1 TSTG72 F-91625 TR-EOP-000063 - Datasheet Archive
SDH / SONET integrated modules Multi-Source Compact Transmitter STM-16 / OC-48 Description These integrated modules are intended
Alcatel 1926 SDH SDH / SONET integrated modules Multi-Source Compact Transmitter STM-16 STM-16 / OC-48 OC-48 Description These integrated modules are intended to be used at SDH and SONET bit rates. The Alcatel 1926 SDH family is a range of compact transmitter modules and compact receiver modules, providing convenient and flexible interfaces for SDH / SONET systems operating at 2.488 Gbit/s and compliant with ITU-T G.957 & G.783 and Telcordia GR-253-CORE GR-253-CORE standards. The transmitter module contains an in-house uncooled laser diode module with a selectable retiming and laser driver. The module is housed in a space-saving 24-pin package, providing the same electrical access for overall applications. Features · New International Standard · Multisource Optical Interfaces · Space-saving package and minimizing cost · Upward compatibility with different features · Operating 1.3 µm wavelength. · Full performance in case temperature range - 5 °C to + 75 °C and - 40 °C to + 85 °C · Single power supply + 5V or - 5.2 V · Power consumption, 0.8 W typical · Alcatel Reliability and Qualification Program for built in quality · Uncooled FP or DFB laser · Clocked or Non-Clocked selectable · Up to 40 km span · Ultra low jitter generation · Digital laser degraded alarm · Back face monitor output Applications Used in transmission systems for Long Haul, Metro, Enterprise and Access markets, the Alcatel 1900 SDH family operates at SONET OC-3, OC-12 OC-12 and OC-48 OC-48 rates as well as at ITU-T SDH rates of STM-1, STM-4 and STM-16 STM-16. Covering all types of SDH / SONET optical interfaces (tributaries and aggregates) the Alcatel 1900 SDH modules are suitable for line systems, local loop systems, Add Drop Multiplexers and digital cross-connects as well as ATM systems. As part of the Alcatel 1900 SDH family, the Alcatel 1926 SDH module is suited for all types of STM-16 STM-16 (Intra-Office, Short Haul, Long Haul, Very Long Haul) and OC-48 OC-48 (Short-Reach, IntermediateReach and Long-Reach) optical interfaces. These modules ensure ease of use and offer new flexibility to system designers. Finally, Alcatel 1926 SDH module is the ideal solution for the exploding 2.5 Gbit/s market. Optical characteristics ITU / SONET Optical budget Center wavelength Optical output power Shutdown optical power Spectral width Extinction ratio Dispersion Path penalty Return loss Condition Symb Min Typical Max I-16/SR-1 I-16/SR-1 0 7 c 1266 1310 1360 Note 1 Snom -9.5 -6 -3 Note 1 Sidle -50 -40 Note 2 4 Note 3 Er 8.2 8.5 Note 4 12 1 24 Min Typical Max S-16.1/IR-1 0 12 1270 1310 1360 -4.5 -2 0 -50 -40 1 8.2 8.5 100 1 24 Min Typical Max L-16.1/LR-1 10 24 1280 1310 1335 -1.5 0 +3 -50 -40 1 8.2 8.5 250 1 24 Unit dB nm dBm dBm nm dB ps/nm dB dB Note 1: Measured at the connector interface. Provision of 0.5 dB is taken for S point measurement. Note 2 : Maximum full width of the central wavelength peak, measured 20 dB down from the maximum amplitude under modulation condition PRBS 223-1 Note 3: Measured at the connector interface under modulation condition PRBS 223-1. Note 4: Measured at BER 10-10. All parameters are specified End-of-Life within the overall relevant operating temperature range. The typical values are referenced to + 25 °C, nominal power supply, beginning of life. Electrical characteristics Parameter Condition Symbol Min Typical Max Unit Supply voltage Note 5 VSUP 4.75 5 5.46 V 140 370 mA Supply current Note 5 ISUP Power consumption PC 0.7 2 W Input data & clock voltage Note 6 ILD 0.5 0.8 1 Vpp Normalized back facet level Note 7 BKL 500 mV Monitor bias level Note 7 BSL 20 mV/mA Logic input & output TTL compatible Note 5: VCC-VEE; with VCC at + 5 V, VEE must be at 0 V; with VEE at - 5.2 V, VCC must be at 0 V. Note 6: Internally AC coupled to 50 load. This sensitivity is achieved by applying at minimum either a 0.5Vpp signal on one input while the other one is tied to ground or by applying two complementary 0.25Vpp signals on both inputs. Note 7: This voltage is measured taking VEE as a reference. All parameters are specified End-of-Life within the overall relevant operating temperature range. The typical values are referenced to + 25 °C, nominal power supply, beginning of life. Absolute maximum ratings Parameter Symbol Min Max Positive supply voltage VSUP 0 6 2 High frequency input voltage VIN Control input voltage VEE VCC-VEE Digital output voltage VEE VCC-VEE Analog output voltage VEE VCC-VEE Storage temperature Indoor TSTG -25 +75 Outdoor -40 +85 Storage 72h max TSTG72 TSTG72 -40 +85 Operating temperature Indoor TOP -5 +75 Outdoor -40 +85 Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only. Unit V Vpp V V V °C °C °C Outline drawing Pin description DI NRZ Data Input True: AC coupled input. A logical one on DI is related to a light on state on the optical fiber. Data line is retimed at the input of the module by the input clock signal when the function is selected. DI NRZ Data Input False: AC coupled input. A logical zero on DI is related to a light on state on the optical fiber. Data line is retimed at the input of the module by the input clock signal when the function is selected. CKI True Clock Input: AC coupled input. The rising edge is in the middle of the data pattern. CKI False Clock Input: AC coupled input. The falling edge is in the middle of the data pattern. SDC Shut Down Command: TTL compatible input. When high the module is in the shut down mode (no optical output power). When open (or low) the module is in the operating mode. SELC Clock Mode Select Command: TTL compatible input. When low (or open) the module operates in the clocked mode. When high the module operates in the non clocked mode. LDA Laser Degrade Alarm: TTL compatible output. When provided a digital alarm indicates that the laser is degraded. The active level is a low level. Pin out N° Symb 1 VEE 2 BACK(+) Description Negative Power Supply Back Facet Monitor N° 24 23 Symb VCC GND 3 4 5 6 BIAS(+) SDC SELC GND Laser Bias Monitor Shut Down Command Clock mode select Command Ground 22 21 20 19 CKI 7 8 9 10 11 12 NUC LDA NUC NUC GND VEE No User Connection Laser Degraded Alarm No User Connection No User Connection Ground Negative Power Supply 18 17 16 15 14 13 GND CKI GND DI GND Di GND NIC VCC Description Positive Power Supply Ground False clock input Ground True clock input Ground False data input Ground True data input Ground No Internal Connection Positive power supply BACK(+) Back Facet Monitor: Analog output. Voltage proportional to the normalized monitoring PIN current depending on the optical output power. BIAS(+) Laser Bias Monitor: Analog output. Voltage proportional to the laser bias current depending on the optical output power. NUC No User Connection: this lead must be left open. NIC No Internal Connection. August 2000 Copyright © 2000 Alcatel Optronics Ordering information Alcatel 1926 SDH ITU-T / SONET I-16.1/SR-1 (µm) 1.3 Budget (dB) 0.7 Dispersion (ps/nm) 12 Temp (°C) -5.+75 -40.+85 Transmitter part number 3CN 00326 ## 3CN 00327 ## Receiver part number 3CN 00336 ## 3CN 00337 ## S-16.1/IR-1 1.3 0.12 100 -5.+75 40.+85 3CN 00328 ## 3CN 00329 ## 3CN 00336 ## 3CN 00337 ## L-16.1/LR-1 1.3 10.24 250 -5.+75 40.+85 3CN 00330 ## 3CN 00331 ## 3CN 00338 ## 3CN 00339 ## Options Transmitter ## Customized versions are available for large quantities. Performance figures contained in this document must be specifically confirmed in writing by Alcatel Optronics before they become applicable to any particular order or contract. Alcatel Optronics reserves the right to make changes to the products or information contained herein without notice. Options Receiver ## Connector : A¡FC/PC B¡SC/PC Connector : A¡FC/PC B¡SC/PC Function : A¡Standard Function : A¡2R B¡3R 2.5 G C¡3R 2.7 G EUROPE Route de Villejust F-91625 F-91625 NOZAY CEDEX Tel : (+33) 1 64 49 44 39 Fax : (+33) 1 64 49 49 61 USA 12030 Sunrise Valley Drive RESTON - VA 22091-3495 Tel : (+1) 703 715 3922 Fax : (+1) 703 860 1183 JAPAN Dai-Tokyo Kasai Shinjuku Building 13F 3-25-3, Yoyogi, Shibuya-Ku TOKYO 151 - 0053 Tel : (+81) 3 5302 4341 Fax : (+81) 3 5302 4331 Standards Compliant with ITU-T G.957 & G.783 & G.691 Telcordia GR-253-CORE GR-253-CORE Optical fiber according to ITU-T G.652 Environment according to IEC 68-2 and MIL STD 883 Telcordia TR-EOP-000063 TR-EOP-000063 LASER RADIATION AVOID EXPOSURE TO BEAM Class 3A laser product ATTENTION OBSERVE PRECAUTIONS FOR HANDLING ELECTROSTATIC DISCHARGE SENSITIVE DEVICES