500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Top Results

Part Manufacturer Description Datasheet BUY
SAS-160-1-1124-8D (6883750002) TE Connectivity (6883750002) SAS-160-1-1124-8D visit TE Connectivity

SCXI-1124

Catalog Datasheet MFG & Type PDF Document Tags

SCXI-1124

Abstract: use several SCXI-1124s in an SCXI system along with other signal conditioning I/O modules. The SCXI-1124 , SCXI 6-Channel Isolated Digital-to-Analog Converter Module SCXI-1124 SCXI-1124 6 isolated , SCXI-1124 is a 6-channel isolated source for DC (low bandwidth) voltage or current signals. The SCXI-1124 , configurable, and includes an onboard EEPROM for storing calibration constants. The SCXI-1124 is ideal for , control several SCXI-1124 modules. Figure 1 is a block diagram of the SCXI-1124. Its major functions
National Instruments
Original
SCXI-1200

SCXI-1124

Abstract: PCI-6032E ! Visit ni.com/info and enter scxi1124. See page 276 to configure your complete SCXI system. 316 , outputs · NI-DAQ driver simplifies configuration and measurement Module SCXI-1124 Frequency Input , Included See page 21 Input Signal Range (0-20 mA) Overview The National Instruments SCXI-1124 is a 6-channel isolated source for static DC (low bandwidth) voltage or current signals. The NI SCXI-1124 , configurable, and includes an onboard EEPROM for storing calibration constants. The SCXI-1124 is ideal for
-
Original
PCI-6032E SCXI-1581 2000/NT/XP ICSES003 CISPR-11

AT-MIO-16

Abstract: SCXI-1124 SCXI 6-Channel Isolated Digitalto-Analog Converter Module SCXI-1124 Features SCX1-1124 6 , Application Software LabVIEW BridgeVIEW LabWindows/CVI LabWindows ComponentWorks SCXI-1124 Overview The SCXI-1124 is a 6-channel isolated source for DC (low bandwidth) voltage or current signals. The SCXI-1124 includes six independently isolated 12-bit DAC channels, each of which you can configure , SCXI-1124 is ideal for applications requiring isolated voltage or current outputs to control a
National Instruments
Original
AT-MIO-16 AT-MIO-16E-2 486/DX

din mount 96 pin cable connector

Abstract: TBX-1326 Modules SCXI-1100, SCXI-1102, SCXI-1181 SCXI-1120, SCXI-1121 SCXI-1124 SCXI-1162, SCXI-1162R, SCXI , terminals for signal connections to the SCXI-1124 module. You cable the TBX-1325 to the SCXI-1124 with , Resistance ­ When used with SCXI modules that source an analog output voltage, such as the SCXI-1124 or , introduce errors caused by voltage drops in the cable. For example, the SCXI-1124 analog output module can
National Instruments
Original
TBX-1326 din mount 96 pin cable connector SBS-96F TBX-1303 TBX-1328 TBX-24F CB-50 TBX-13033

SCXI-1124

Abstract: SCXI-1102 unless otherwise noted. SCXI-1581 SCXI-1124 Excitation Analog Output ­ Output Characteristics , . SCXI-1124. European Compliance EMC , and Windows NT; Not for Waveform Generation. to the SCXI-1124 User Manual for more information
-
Original
SCXI-1310 777687-10 SCXI-1300 TBX-96 SH96-96

SCXI-1163R

Abstract: SCXI-1308 -1126 SCXI-1124 SCXI-1162, SCXI-1162HV, SCXI-1163, SCXI-1163R SCXI-1120, SCXI-1120D, SCXI-1121,SCXI , -1325 .777207-25 The TBX-1325 is a terminal block with 30 screw terminals for signal connections to the SCXI-1124 module. You cable the TBX-1325 to the SCXI-1124 with the SH48-48-A shielded cable. Signal Conditioning , as the SCXI-1124 or excitation voltage of the SCXI-1121, the wire resistance of the shielded cable (0.21 /m per wire) can introduce errors caused by voltage drops in the cable. For example, the SCXI-1124
-
Original
SCXI-1104 SCXI-1327 SCXI-1308 SCXI 1163 1324f opentherm R96-96 SH32-32-A SH48-48-B TBX-1316 SCXI-1120/D SCXI-1125

EN 13034

Abstract: SCXI-1100 -1181 SCXI-1120, SCXI-1120D, SCXI-1121, SCXI-1126 SCXI-1120, SCXI-1120D, SCXI-1121, SCXI-1126 SCXI-1124 , connections to the SCXI-1124 module. You cable the TBX-1325 to the SCXI-1124 with the SH48-48-A shielded , voltage, such as the SCXI-1124 or excitation voltage of the SCXI-1121, the wire resistance of the , , the SCXI-1124 analog output module can source a maximum of 5 mA in voltage output mode. Therefore, a
National Instruments
Original
EN 13034

SCXI-1124

Abstract: SCXI-1163 conditioning front-end for PC plug-in DAQ boards. The SCXI-2000 chassis and SCXI-1124 communications module , -1121 SCXI-1122 SCXI-1126 SCXI-1140 SCXI-1141 SCXI-1124 SCXI-1160 SCXI-1161 SCXI-1162 SCXI
National Instruments
Original
SCXI-200 RS-232/RS-485 RS-485 RS-232 SCXI-2400 SCXI-1000/1001

scxi-1306

Abstract: 20-screw SCXI-1100, SCXI-1102, SCXI-1102B/C, SCXI-1181 SCXI-1120/D, SCXI-1125, SCXI-1126 SCXI-1124 SCXI , -1120D SCXI-1126 SCXI-1125 SCXI-1121 SCXI-1122 SCXI-1124 SCXI-1127 SCXI-1128 SCXI-1129 SCXI , -1325 .777687-25 26-screw terminal block for the SCXI-1124 module. Figure 7. SCXI-1328 Terminal Block SCXI , -1325 .777207-25 Terminal block with 30 screw terminals for signal connections to the SCXI-1124 module. You cable the TBX-1325 to the SCXI-1124 with the SH48-48-A shielded cable. Figure 13. TBX-1326 Figure 14
National Instruments
Original
scxi-1306 20-screw lvdt sensor SCXI-1315 SCXI-1540 SCXI-1331 SCXI-13 TC-2095 BNC-2095 2007-9360-321-101-D

NEC IC Product Guide Product Catalog

Abstract: AT-MIO-64F-5 Conditioning Modules Module Type Description Isolation SCXI-1124 Analog output Six 12-bit DACs , SCXI1124 SCXI1140, 1141 SCXI1161 SCXI11601 SCXI1162 (HV), 1163 (R) SCXI1180 SCXI1181 , SCXI1120, 1121 SCXI1122 SCXI1124 SCXI1140, 1141 SCXI1160 SCXI1161 SCXI1162( HV), 1163 , module (SCXI-116x or SCXI-1124) Table 15. Reserved DAQ Device Analog Input Channel Channel Status , input channels when cabled directly to: SCXI-1124 or SCXI-116x 1 The SCXI-1100 output connector
National Instruments
Original
NEC IC Product Guide Product Catalog AT-MIO-64F-5 AT-MIO-16 E 10 AT-MIO-16F-5 NB-DIO-96 SCXI-1349 340746D-01 AT-485

SCXI-1303

Abstract: SCXI-1304 terminals for signal connections to the SCXI-1124 module. SCXI-1326 The SCXI-1326 is a high-voltage , signal input range to 250 Vrms, switch configurable per channel 2 SCXI-1122 SCXI-1124 SCXI
National Instruments
Original
SCXI-1303 SCXI-1304 SCXI-1321 SCXI-1302 SCXI-1180 SCXI-1305 SCXI-132X SCXI-1320

NB-DIO-96

Abstract: 16E10 Modules Module Type Description Isolation SCXI-1124 Analog output Six 12-bit DACs, current , Block SCXI1100, 1102 SCXI-1303 · SCXI-1300 SCXI1120, 1121 · SCXI1122 SCXI1124 , -1328 · SCXI1120, 1121 SCXI1122 SCXI1124 SCXI1140, 1141 SCXI1160 SCXI1161 , output module (SCXI-116x or SCXI-1124) Table 15. Reserved DAQ Device Analog Input Channel Channel , to: SCXI-1100, SCXI-1102, SCXI-1122 SCXI-1121 SCXI-1120, SCXI-1140, or SCXI-1141 SCXI-1124 or
National Instruments
Original
16E10 PCI-MIO-16XE-10 Digital IC National catalog SCXI-1181K PR50-50F NB-DIO-24 340746C-01

SCXI-1302

Abstract: opentherm located in module SCXI-1326 SCXI-1122 SCXI-1124 SCXI-1140 SCXI-1141 SCXI-1160 SCXI-1161 SCXI , 26 screw terminals for signal connections to the SCXI-1124 module. SCXI-1326 ­ The SCXI-1326 is a
National Instruments
Original
SCXI-1330 SCXI-1322 SCXI-13032 SCXI-1324 SCXI-1301 SCXI-1325

SCXI-1100

Abstract: SCXI-1102 -1122 SCXI-1124 SCXI-1160 SCXI-1161 SCXI-1162, SCXI-1162HV SCXI-1163, SCXI-1163R SCXI-1200 Type
National Instruments
Original
NT/95/3

SCXI-1102

Abstract: SCXI-1581 · ni.com SCXI-1124. European Compliance
National Instruments
Original
transistor 1102 Logger

strain gauge and load cells rs232

Abstract: PC-DIO-24 Choices Module Channels Description Ranges/Switching Load Isolation Page SCXI-1124
National Instruments
Original
strain gauge and load cells rs232 PC-DIO-24 HyperLabs rs485 multiplexer

SCXI-1180

Abstract: strain gauge and load cells rs232 Module Channels Description Ranges/Switching Load Isolation SCXI-1124 6 Analog
National Instruments
Original

strain gauge and load cells rs232

Abstract: NB-DIO-96 Module Channels Description Ranges/Switching Load Isolation SCXI-1124 6 Analog
National Instruments
Original
NB-DIO-32F 1102B