500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Top Results

Part Manufacturer Description Datasheet BUY
TPS61087DRCR Texas Instruments 18.5V, 3.2A, 650kHz / 1.2MHz Step-Up DC-DC Converter with Forced PWM Mode 10-VSON -40 to 85 visit Texas Instruments Buy
TPS61085DGKR Texas Instruments 18.5V, 2A, 650kHz / 1.2MHz Step-Up DC-DC Converter w/ Forced PWM Mode 8-VSSOP -40 to 85 visit Texas Instruments
TPS61087DRCT Texas Instruments 18.5V, 3.2A, 650kHz / 1.2MHz Step-Up DC-DC Converter with Forced PWM Mode 10-VSON -40 to 85 visit Texas Instruments Buy
TPS61087DRCRG4 Texas Instruments 18.5V, 3.2A, 650kHz / 1.2MHz Step-Up DC-DC Converter with Forced PWM Mode 10-VSON -40 to 85 visit Texas Instruments
HPA01142PWR Texas Instruments 18.5V, 2A, 650kHz / 1.2MHz Step-Up DC-DC Converter w/ Forced PWM Mode 8-TSSOP -40 to 85 visit Texas Instruments
TPS61085TDGKR Texas Instruments 18.5V, 2A, 650kHz, 1.2MHz Step-Up DC-DC Converter with Forced PWM Mode (extended temp range) 8-VSSOP -40 to 105 visit Texas Instruments Buy

SAE AS39029 force

Catalog Datasheet MFG & Type PDF Document Tags

WA23-395L

Abstract: WA23 . Conforms to SAE AS39029 requirements. Terminate with pneumatic crimp tool shown on next page. Figure , 46 Amperes 26 millivolts maximum 5 ounce minimum 220 lbs. (978 newtons) SAE AS39029 para. 4.7.5, EIA-364-06 SAE AS39029 para. 4.7.5, EIA-364-06 SAE AS39029 para. 4.7.6, EIA-364-37 SAE AS39029 para. 4.7.9, EIA-364-08 Durability 500 mating cycles SAE AS39029 para. 4.7.10 CONTACT REMOVAL TOOL , separately. Qualified to M22520/23, the WA23 tool is specified for use with SAE AS39029 closed barrel
Glenair
Original
WA23-395L WA23 locator to wa23 SAE/AS39029 850-014F 850-013F M22520/23-01 WA23-2 M22520/23-02

WA23-395L

Abstract: . Conforms to SAE AS39029 requirements. Terminate with pneumatic crimp tool shown on next page. Figure , AS39029 para. 4.7.5, EIA-364-06 SAE AS39029 para. 4.7.5, EIA-364-06 SAE AS39029 para. 4.7.6, EIA-364-37 SAE AS39029 para. 4.7.9, EIA-364-08 Durability 500 mating cycles SAE AS39029 para. 4.7.10 , use with SAE AS39029 closed barrel copper alloy contacts. PNEUMATIC TOOL 859-025 LOCATOR , DESCRIPTION REQUIREMENT PROCEDURE Test Current Contact Resistance Minimum Separation Force Crimp
Glenair
Original

WA23-395L

Abstract: locator to wa23 . Conforms to SAE AS39029 requirements. Terminate with pneumatic crimp tool shown on next page. Part Number , cycles PROCEDURE SAE AS39029 para. 4.7.5, EIA-364-06 SAE AS39029 para. 4.7.5, EIA-364-06 SAE AS39029 para. 4.7.6, EIA-364-37 SAE AS39029 para. 4.7.9, EIA-364-08 SAE AS39029 para. 4.7.10 CONTACT REMOVAL , specified for use with SAE AS39029 closed barrel copper alloy contacts. PNEUMATIC TOOL 859-025 LOCATOR , Specifications DESCRIPTION Test Current Contact Resistance Minimum Separation Force Crimp Tensile Strength
Glenair
Original
SAE AS39029 force AS-39029 pneumatic sae-as39029 QUADRAX CONNECTOR

WA23-395L

Abstract: steel hood. Conforms to SAE AS39029 requirements. Terminate with pneumatic crimp tool shown on next , SAE AS39029 para. 4.7.5, EIA-364-06 SAE AS39029 para. 4.7.5, EIA-364-06 SAE AS39029 para. 4.7.6, EIA-364-37 SAE AS39029 para. 4.7.9, EIA-364-08 SAE AS39029 para. 4.7.10 Wire Dia. (in.) Wire Dia. (mm , separately. Qualified to M22520/23, the WA23 tool is specified for use with SAE AS39029 closed barrel , Contact Resistance Minimum Separation Force Crimp Tensile Strength Durability REQUIREMENT 46
Glenair
Original
M81969/14-12

IEC-60512-6

Abstract: stub ACME torque force SAE AS39029 Table 9 EIA-364-37 Demating force (Series 804) Series 804 , Standards SAE AS39029 3 B Contacts, Electrical Connector, General Specification For REQUIREMENTS , , copper alloy contacts REQUIREMENT PROCEDURE SAE AS39029 Table 5 Wire Size 8 10 12 14 16 , REQUIREMENT PROCEDURE Low level contact resistance SAE AS39029 Table 4 Insulation resistance , Size Series 800 803 804 Series 801 Series 805 B Minimum Force in Pounds 5 5 25
Glenair
Original
IEC-60512-6 stub ACME torque EIA-364-32 IEC-60512-11-4 EIA-364-26 MIL-STD-810 EIA-364-10 EIA-364-03
Abstract: alloy contacts meet the requirements of SAE AS39029. Use with all Series 28 HiPer-D crimp connectors , (3.58) MIN .237 / .231 (6.02 / 5.87) .518 (13.16) REF .289 / .279 (7.34 / 7.09) See SAE AS39029 for additional electrical, mechanical and environmental specifications. D-3 YELLOW GREEN , Sep. Force: 0.7 ounces Crimper: 809-015 (M22520/2-01) Positioner: Pin 859-018 (M22520/2-09 Glenair
Original
QQ-N-290 M39029 M39029/58-360 M39029/57-354 M22520/2-06 M81969/14-01
Abstract: series 28 HiPer-D Contacts and Tools #20 crimp contacts for standard HiPer-D connectors #20 Crimp Contacts Fig. 1 #20 contacts accept #20 to #24 AWG wire. These gold-plated copper alloy contacts meet the requirements of SAE AS39029. Use with all Series 28 HiPer-D crimp connectors with size , , passivated. D See SAE AS39029 for additional electrical, mechanical and environmental specifications , Temperature Range: -65° to + 200° C. Socket Min. Separation Force : 0.7 ounces White Blue Orange à Glenair
Original
M39029/64-369 M39029/63-368 20AWG M22520/2-08 M81969/39-01

EIA-364-31 method iv

Abstract: EIA-364-35 Resistance SAE AS39029 Table V Max Wire Test Voltage Size Current Drop 8 46 26 10 , Force Contact Min. Min. Size Ounces Newtons 22 0.5 0.14 20 0.7 0.19 SAE AS39029 Mating and Un-mating Force, connectors with size 20 or size 22 contacts Shell Min. Max , and un-mating force. EIA-364-09 IEC-60512-5 Test 9a Corrosion (Salt Mist) No exposure of , force and dielectric withstanding voltage. EIA-364-10 Altitude Immersion No evidence of
Glenair
Original
EIA-364-35 EIA-364-31 method iv EIA-364-31 IEC-60512-5 test 9a D-5948 EIA-364-23 EIA-364-21 IEC-60512-3-1 EIA-364-29 EIA-364-13
Abstract: -364-83 Unwired connectors Socket Contact Engagement and Separation Force C ontact engagement and separation forces shall meet the requirements of SAE AS39029 Table 9 SAE AS39029 Thermal Shock No , Removal Force (Maintenance Aging) Contact resistance (copper alloy) Contact resistance (ferrous , Protection IP67 rating SHELL FORCE SIZE (lbs.) 18 50 20 75 24 85 28 105 32 115 , cycles. SAE AS50151 Para. 4.6.20 EIA-364-10 MIL-STD-810G Method 508.6 MIL-DTL-38999L Para Glenair
Original
EIA-364-105 MIL-DTL-38999 EIA-364-28 MIL-STD-810F

crimping positioners by manufacturer

Abstract: Mil Spec Contacts For Series 79 Micro-Crimp Connectors Aerospace Standard AS39029 (SAE) defines the , stainless steel hoods to protect against probe damage. Approved to SAE AS39029. Contacts are bulk packaged , copper alloy. Approved to SAE AS39029. VSWR rating 1.5:1 maximum up to 700 MHz. 5000 megohm insulation , contacts are gold-plated copper alloy. Approved to SAE AS39029. VSWR rating 1.5:1 maximum up to 700 MHz , contacts. For example, pin contacts used in MIL-C-38999 connectors are specified in AS39029/58. Each
Glenair
Original
crimping positioners by manufacturer AS39029/58 01-AUG-2008
Abstract: '¢ Integrated retention clip and o-ring sealing â'¢ Contacts meet all applicable SAE AS39029 requirements â'¢ Contacts accommodate wire range of 30-24 AWG (.042 max diameter) â'¢ Low mating force, 1/3 insertion force of typical fixed Micro-D TwistPin â'¢ Minimum of 2 guide pins to prevent Glenair
Original

IEC-60512-4-1

Abstract: IEC-60512-5 resistance SAE AS39029 Table V Max Wire Test Voltage Size Current Drop 12 23 42 14 , -364-29 SAE AS39029 Threaded coupling connector coupling torque shall not exceed the following , resistance, DWV, and mating and unmating force. B E-Mail: sales@glenair.com K L M Reference , Impact Contact retention Contact Size 23 20 20HD 16 12 Contact separation force , 24 32 36 23 Series 804 quick-disconnect connectors K L Unmating force (Series 804
Glenair
Original
EIA-364-20 IEC-60512-4-1 EIA-364-83 EIA-365-02 EIA-365-35 IEC-60512-1-1 ASTM-E595 01-JANUARY-2010

Series 841

Abstract: Series 80 Stingerâ"¢ Connectors Series 841, 844 and 845 Mighty Mouse Stingerâ"¢ Equipped Connectors General Information ƒƒ Front-release crimp contact solution ƒƒ High-density .050â' centers ƒƒ Integrated retention clip and O-ring sealing ƒƒ Stingerâ"¢ contacts meet all applicable requirements of SAE AS39029 ƒƒ Low mating force, 1/3 insertion force of typical fixed Micro-D twist pin ƒƒ Available for Series 801 (threaded stub-ACME), 804 (push-pull) and 805
Glenair
Original
Series 841

MS422N

Abstract: SGMC104 customer â'dock to stockâ' programs. Applicable products qualified to MIL-DTL-24308, SAE AS39029, DSCC , , AS39029/34 and MIL-C-28748/14, SAE AS39029/35. SAE Eleven c ­ onnector variants, 4 , contacts are QPL listed under SAE AS39029 and MIL-DLT-24308 specifications. PosiBand is also qualified , contact, which can cause electrical failure. 7 #7;PosiBand is qualified under SAE AS39029 and MIL-DTL , Qualified to: â'¢ SAE AS39029/34 & 39029/35 Telecommunication: â'¢ UL File # E49351 C H A R A C T
Positronic Industries
Original
MS422N SGMC104 Positronic Industries Positronic SGM SERIES MC422N C-008 F-32020

EIA-364-31

Abstract: IEC-60512-5 DESCRIPTION PROCEDURE Contact Resistance SAE AS39029 Table V Max Wire Test Voltage Size , 12 3.0 Min. Newtons 0.14 0.19 0.56 0.83 B EIA-364-10 Altitude Immersion A SAE AS39029 Impact, Cable Connectors Fluid Immersion Contact Separation Force C D F G H , , DWV, and mating and unmating force. EIA-364-09 IEC-60512-5 Test 9a Corrosion (Salt Mist) No , force and dielectric withstanding voltage. No evidence of moisture on connector interface or contacts
Glenair
Original
IEC-60512-6-4 IEC-60512-23-3 EIA-364-42 olive oil IEC-60512-11-12 IEC-60512-6-3 1000MH

positronic

Abstract: Positronic Industries ' programs. Applicable products qualified to MIL-DTL-24308, SAE AS39029, DESC 85039, MIL-DTL-28748, Space , , MIL-C-28748/14, SAE AS39029/34 and SAE AS39029/35. Eleven connector variants, 4 through 104 , body. Posiband contacts are QPL listed under SAE AS39029. 1 DIMENSIONS ARE IN INCHES [MILLIMETERS , listed under SAE AS39029 specification. For more details about the advantages of the PosiBand® system , '¢ MIL-C-28748/13 & 28748/14 Contacts Qualified to: â'¢ SAE AS39029/34 & 39029/35 Telecommunication
Positronic Industries
Original
ISO9001 ISO14001 AS9100 MIL-STD-790

M39029 pin crimp Coaxial

Abstract: Radial arinc 620 601 033 application requirements. About SAE AS39029 Crimp Contacts In a marketplace saturated with specialty , approved to SAE AS39029. Shielded Coaxial Contacts Shielded coaxial contacts have a special role in the , contacts conform to the requirements of Aerospace Standard AS39029. This SAE specification defines the , AS39029 QPL and Glenair Commercial High-Performance Connector Contacts United States ï , ® Italy  Spain  Japan Aircraft On Ground? Need Contacts Now? AS39029 In Stock
Glenair
Original
M39029 pin crimp Coaxial Radial arinc 620 601 033 Reducing sleeve, AWG 16-20 MIL-PRF-29504 D38999 MIL-PRF-28876 D-61449

DD-78

Abstract: FC8020D2 crimp tool Printed Board Mount PosiBand® Closed Entry MIL-DTL-24308 and SAE AS39029 UL Recognized File #E49351 , qualified to MIL-DTL24308 and SAE AS39029 (see page 82 for more information). Densi-D series connectors , SUPPLIED WITH CONNECTOR OR ORDERED SEPARATELY. QUALIFIED TO SAE AS39029 Note: Connectors can be kitted , SPECIFICATION CONTACTS FEMALE CONTACT STANDARD FINISH: per SAE AS39029 specifications MALE CONTACT , terminations. The low press-in force required to install the contacts into the board eliminates printed board
Positronic Industries
Original
DD-78 FC8020D2 crimp tool FS8022D2 LR54219

Performance Specifications

Abstract: . Newtons 27 67 111 111 EIA-364-29 Contact Separation Force Contact Min. Size Ounces 23 0.5 20 0.7 16 2.0 12 3.0 Min. Newtons 0.14 0.19 0.56 0.83 SAE AS39029 Mating and Unmating Force Maximum mating/unmating force: (6 pounds) + (# of size 23 contacts X , , shell-to-shell resistance, DWV, and mating and unmating force. EIA-364-09 IEC-60512-5 Test 9a Corrosion , and oils. Connector shall meet mating/unmating force and dielectric withstanding voltage. EIA
Glenair
Original
Performance Specifications EIA-364-70 IEC-60512-2-6 EIA-364-66 IEC-60529 EIA-364-54

m19500/469

Abstract: m19500/469-01 OF AUTOMOTIVE ENGINEERS (SAE) AS39029/57 - Contacts, Electrical Connectors, Socket Crimp , ) (Application for copies should be addressed to the Society Of Automotive Engineers, SAE World Headquarters , soldered to the leads or AS39029/57contacts may be used. Other clips may be used provided they have equal or less mass than the AS39029/57 contact. No forced air shall be permitted and the diodes shall be , Air Force - 85 NASA - NA DLA - CC Preparing activity: DLA - CC (Project 5961-2008-067
-
Original
m19500/469 m19500/469-01 jxm19500/469-01 jm19500 M19500 MIL-PRF-19500/469 MIL-PRF-19500/469D MIL-PRF-19500/469C M19500/469-01 MIL-PRF-19500 M19500/469- JXM19500/469-01
Showing first 20 results.