500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Top Results

Part Manufacturer Description Datasheet BUY
XTR103BU/1K Texas Instruments 4-20mA Current Transmitter with RTD Excitation And Linearization 16-SOIC visit Texas Instruments
XTR103BU Texas Instruments 4-20mA Current Transmitter with RTD Excitation And Linearization 16-SOIC visit Texas Instruments
XTR103AU/1K Texas Instruments 4-20mA Current Transmitter with RTD Excitation And Linearization 16-SOIC visit Texas Instruments
XTR103AU Texas Instruments 4-20mA Current Transmitter with RTD Excitation And Linearization 16-SOIC visit Texas Instruments
XTR103AP2 Texas Instruments 4-20mA Current Transmitter with RTD Excitation And Linearization 16-PDIP visit Texas Instruments
XTR103BP Texas Instruments 4-20mA Current Transmitter with RTD Excitation And Linearization 16-PDIP visit Texas Instruments

RTD PT100 3wire

Catalog Datasheet MFG & Type PDF Document Tags
Abstract: Validation Key Increment Key Input Types and Ranges Type J J DIN K T E S R B N C RTD (Pt100, 3-wire) MV* Range -200 to 1200°C -328 to 2192°F -200 to 1000°C -328 to 1832°F -200 , Section A ß User Selectable Inputs: Thermocouple, RTD, Current, Voltage ß User Selectable Omega Engineering
Original

rtd pt100

Abstract: 7-segment 4 digit Function/Range J Thermocouple K Thermocouple RTD, PT100 3-wire E Thermocouple T Thermocouple Selection , Excitation POWER REQUIREMENTS AC DC ACCURACY @ 25°C as % of rdg Sensor Type RTD Pt 100 J K E T ENVIRONMENTAL
Simpson Electric
Original
rtd pt100 7-segment 4 digit rtd pt100 3 wire RS485 VAC/120VAC 10DCV 100DCV 300DCV
Abstract: , R, S, B; RTD Pt100, 3-Wire alpha=0.00385; Process: 0 to 50 mV, 0 to 10 V, 4 to 20 mA, 0 to 20 mA , % of span error; RTD Pt100, 50 â"¦/lead: , Warranty Program CN1166 Series 240 $ Basic Unit ß Universal Input: Thermocouple, RTD , : Adjustable ± input span P-38 RTD Sensor Current: 150 µA (approximately) Accuracy: ±0.25% of span  , (PT100) User-selectable with Operating Conditions â'bumplessâ' transfer into Ambient Temperature Omega Engineering
Original
RS-485 CN1166-R1-F3 GKQSS-316G-12 BD1600-R BD1600-DC BD1600-T

CTL-6-S

Abstract: Fuji Electric PXR4 Manual signal> Thermocouple °C Thermocouple °F RTD Pt100 3-wire type °C RTD Pt100 3-wire type °F 1 to 5V DC , Screw-terminal type 5 Thermocouple °C Thermocouple °F Resistance bulb Pt100 3-wire type °C Resistance bulb Pt100 3-wire type °F 1 to 5V DC 4 to 20mA DC 6 Relay contact output , Thermocouple °F Resistance bulb Pt100 3-wire type °C Resistance bulb Pt100 3-wire type °F 1 to 5V DC 4 to , Specification 4 T R Thermocouple °F Resistance bulb Pt100 3-wire type I (°C) Note 5
Fuji Electric
Original
CTL-6-S Fuji Electric PXR4 Manual PXW4 PXZ4 TRANSFORMER CTL-6-S CTL-12-S36-8 2010-9/15FOLS

pt100 sensor interface WITH ADC

Abstract: rtd temperature instrumentation amplifier circuit . 24 RTD Input with A/D Converter Output
Intersil
Original
pt100 sensor interface WITH ADC rtd temperature instrumentation amplifier circuit pt100 temperature sensor schematic PT100 bridge adc pt100 schematic pt100 temperature wheatstone AN1298 EL817 EL8170 BAT54S 2N7002

pt100 sensor interface WITH ADC

Abstract: rtd temperature instrumentation amplifier . 23 RTD Input with A/D Converter Output
Intersil
Original
rtd temperature instrumentation amplifier design the instrumentation amplifier with bridge circuit diagram of instrumentation amplifier instrumentation amplifier pt100 temperature sensor schematic channels PT100 Thermocouple Amplifier ISL28271

PXW4

Abstract: TRANSFORMER CTL-6-S > Thermocouple °C Thermocouple °F RTD Pt100 3-wire type °C RTD Pt100 3-wire type °F 1 to 5V DC 4 to 20mA DC , Screw-terminal type 5 Thermocouple °C Thermocouple °F Resistance bulb Pt100 3-wire type °C Resistance bulb Pt100 3-wire type °F 1 to 5V DC 4 to 20mA DC 6 Relay contact output , Resistance bulb Pt100 3-wire type °C Resistance bulb Pt100 3-wire type °F 1 to 5V DC 4 to 20mA DC 6 , self-tuning Heating and cooling (PID,fuzzy PID) Input signal Resistance bulb Pt100 Thermocouple Voltage
Fuji Electric
Original
fuji pxz4 Fuji Electric PXR4 humidity controller Manual CTL-6-S-H DSP31 PT100 Platinum Resistance Temperature Detector PT100 thermistor 2003-6/30FIS

RTD PT100 3wire

Abstract: PT-100 RTD 3 wire mm, thin film Pt100 RTD element, Class A accuracy with 4-wire fiberglass insulated cable 1 m (40 , Dia. x 25 long mm, Pt100 wire wound element, Class A accuracy with 3-wire fiberglass insulated cable , Response (63%) T Less Than 1 Second U #7; igh Accuracy Class A, Pt100 and H Pt1000 RTD Elements Standard , : RTD-3-F3105-36-T-1/3, 100 Ω, 2 x 2 mm, thin film Pt100 RTD element, 1â"3 DIN accuracy with 4 , -2-1PT100KN2515-36-T-MTP, 100 Ω, 1.5 Dia. x 25 long mm, Pt100 wire wound element, Class A accuracy with 3-wire PFA insulated
Omega Engineering
Original
RTD PT100 3wire PT-100 RTD 3 wire 4 wire rtd cable RTD-3-F3105-36-T-1 RTD-2-1PT100KN2528-36-G RTD-2-F3105-36-G RTD-2-F3102-36-G RTD-2-1PT100KN2515-36-G RTD-2-F3145-36-G RTD-2-F3142-36-G
Abstract: ) Pt100 Standard IEC/DIN/EN 60 751-2 Long-term test IEC 770 6.3.2 RTD measuring current , reproduced in full. No cable compensation {3} RTD 3-wire cable compensation 3-wire compensation for transfer resistance {4} RTD 3-wire cable compensation Potentiometer Resistance , FlexTop 2202 Temperature Transmitter 4.20 mA transmitter for Pt100 sensors 2-, 3- or 4 , Description FlexTop 2202 is a 4.20 mA loop-powered transmitter for Pt100 sensors. The Flex-Program has a Baumer
Original
UK/2013-02-10
Abstract: resistance {4} 3-wire cable compensation RTD Potentiometer Resistance R R 4 , FlexTop 2202 Temperature Transmitter 4.20 mA transmitter for Pt100 sensors 2-, 3- or 4 , transmitter for Pt100 sensors. The Flex-Program has a datalogging facility enabling the user to monitor , . Vibrations GL, test 2 (IEC 68-2-6) Pt100 Standard IEC/DIN/EN 60 751-2 Long-term test IEC 770 6.3.2 RTD measuring current 0.3 mA, continuously Sensor type 2-, 3- or 4-wires {1} Sensor Baumer
Original
EN/2011-11-29

RTD PT100 3wire

Abstract: MCR-SL-PT100-LP-I 5 6 3-wire 4-wire TC 1 RTD 1 1 RTD 1 RTD 1 MCR-FL-.-LP , supplied with the following default configuration: PT100 sensor, 0.100°C (32.212ºF) measuring range, 3-wire , I 1 1 2 3 4 Compressor PT100 in 3-wire technology PHOENIX CONTACT page 6 of 6 , Programmable Loop-Powered Temperature Measuring Transducer for PT100 Sensors MCR-SL-PT100-LP-I 1. Brief Description ­ For PT100 resistance thermometers in 2, 3 or 4wire technology ­ Can be mounted on
Phoenix Contact
Original
pt100 temperature sensor circuit connection Pt100 3 wire Phoenix/pt100 4-20 ma pt100 temperature transducers MCR-SL-PT100 rtd pt100 4-20ma connections

TR800

Abstract: RTD PT100 3wire , K, and Pt-100 RTD Bottom View of Cover Fixed-Range Units Offered in Standard or Special , process signals, including J, K, and Pt100 inputs. Each transmitter offers 2 to 3-wire compensation and , SPAN RTD: 20°C (36°F) min, 500°C (900°F) max TC: 10mV min span * 0+50 INPUT RTD: Pt-100, 2 , (for RTD) Stability (For Both Zero & Span): Pt-100 (100°C span): 0.03% of span/°C, TC/mV (25mV input , terminal two. For Pt-100 RTD Inputs, connect the Pt-100 leads to input terminals 4, 5, and 6 according to
Simpson Electric
Original
TR800 rtd pt100 4-20ma wiring diagram RTD PT-100 3 wire pt100 sensor wiring diagram rtd pt100 sensor PT-100 wiring diagram 500MH
Abstract: FlexTemp 2311 Universal Transmitter 4.20 mA transmitter RTD, T/C, mV and R inputs Isolation voltage 2 kVac Configuration via FlexProgrammer Accuracy better than 0.1°C (Pt100) Configurable , isolation between input and output. The input can be configured for RTD or T/C sensors, resistance , . The built-in temperature sensor or a remote Pt100 sensor can be used to compensate for "cold junction , CJC-compensation {1} Local < 0.7°C Storage temperature -55.90°C RTD measuring current 0.2 mA Baumer
Original
UK/2007-06-01

MCR-SL-PT100-LP-I

Abstract: PT100 application note configuration: PT100 sensor, 0.100°C (32.212ºF) measuring range, 3-wire termination. Headquar ters , MCR-SL-.-LP-. 5 RTD 1 3-wire 1 RTD 1 4-wire RTD 1 2 2 1 3 , default configuration: PT100 sensor, 0.100°C (32.212ºF) measuring range, 3-wire termination. To , / 3 0 m A 1 P O W E R 1 2 3 4 15.05.05 TNR: 5107584-02 PT100 in 3-wire , Programmable Loop-Powered Temperature Measuring Transducer for PT100 Sensors MCR-SL-PT100-LP-I 1
Phoenix Contact
Original
PT100 application note PT100 SENSOR PT100 IEC 751 pt100 thermometer PT100 temperature transducer 3 wire application note pt100

PT-100 385 4wire

Abstract: PT-100 385 3wire seven RTD types, plus volts and ohms. The 724 even handles high-speed pulsed RTD circuits and provides , PT-100 (385) 0.33 °C PT-100 (393) 0.3 °C PT-100 (JIS) 0.3 °C PT-200 (385) 0.2 , -1000 (385) Resistance 0.0 Ω to 400.0 Ω 0.1 Ω (4-wire) 0.15 Ω (2- and 3-wire) Resolution 0.1 °C J 0.7 °C 401 Ω to 1500 Ω 0.5 Ω (4-wire) 1 Ω (2- and 3-wire) K 0.8 °C T 0.8 °C 1500 Ω to 3200 Ω 1 Ω (4-wire) 1.5 Ω (2- and 3-wire) E 0.7 °C R
FLUKE
Original
PT-100 385 4wire PT-100 385 3wire rtd 1186 ITS-90 PTS-68 36-FLUKE
Abstract: Resistance TC R R + RTD 3-wire cable compensation External CJC-compensation No , FlexTop 2221 Universal Transmitter 4.20 mA transmitter with HART® communication. RTD, T/C, mV , Accuracy < 0.1°C (Pt100) Configurable linearisation, damping and status indication Current-trim and , configured for RTD or T/C sensors, resistance, current or voltage signals. Either 2-, 3- or 4-wire connection can be selected for the resistance input. The built-in temperature sensor or a remote Pt100 Baumer
Original
UK/2010-03-03
Abstract: Resistance TC R R + RTD 3-wire cable compensation External CJC-compensation No cable , FlexTop 2211 Universal Transmitter 4.20 mA transmitter RTD, T/C, mV and R inputs Isolation voltage 3.75 kVac Configuration via FlexProgrammer Accuracy better than 0.1°C (Pt100) Configurable , output. The input can be configured for RTD or T/C sensors, resistance, current or voltage signals , sensor or a remote Pt100 sensor can be used to compensate for "cold junction" (CJC) if thermocouples are Baumer
Original
EN/2011-11-18
Abstract: R R + RTD 3-wire cable compensation External CJC-compensation No cable compensation {3} 3-wire compensation for transfer resistance {4} 3-wire cable compensation Pt xxx RTD , FlexTop 2211 Universal Transmitter 4.20 mA transmitter RTD, T/C, mV and R inputs Isolation voltage 3.75 kVac Configuration via FlexProgrammer Accuracy better than 0.1°C (Pt100) Configurable , output. The input can be configured for RTD or T/C sensors, resistance, current or voltage signals Baumer
Original

pt100/RTD PT100

Abstract: rtd temperature instrumentation amplifier circuit : The measurement range is ­100°C to +200°C for a 3-wire Pt100 RTD connection. Determine the values for , ) TABLE I. RZ, RG, RLIN1, and RLIN2 Standard 1% Resistor Values for 3-Wire Pt100 RTD Connection with , standard 1% RG resistor values for a 3-wire Pt100 RTD connection with linearization. LINEARIZATION , the 1% resistor values for a 3-wire Pt100 RTD connection. If no linearity correction is desired, the , ) LOW UNADJUSTED ERROR TWO PRECISION CURRENT SOURCES: 800µA each LINEARIZATION 2- OR 3-WIRE RTD
Texas Instruments
Original
pt100/RTD PT100 signal conditioning circuit for pt100 4-20 mA 13000 transistor TO-220 basic standard current source pt100 temperature sensor circuit diagram circuit diagram bridge transducer 4-20ma XTR105 SBOS061B DIP-14 SO-14
Abstract: FlexTemp 2321 Universal Transmitter 4.20 mA transmitter with HART® communication. RTD, T/C, mV , Accuracy < 0.1°C (Pt100) Configurable linearisation, damping and status indication Current-trim and , and output. The input can be configured for RTD or T/C sensors, resistance, current or voltage , temperature sensor or a remote Pt100 sensor can be used to compensate for "cold junction" (CJC) if , rangesâ' Protocol HCF standard, Rev.5 CJC-compensation Local < 0.7°C Features {1} RTD Baumer
Original
Showing first 20 results.