500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Top Results

Part Manufacturer Description Datasheet BUY
DS3695ATM Texas Instruments Multipoint RS485/RS422 Transceivers 8-SOIC -40 to 85 visit Texas Instruments
DS3695ATMX/NOPB Texas Instruments Multipoint RS485/RS422 Transceivers 8-SOIC -40 to 85 visit Texas Instruments Buy
DS3695AM/NOPB Texas Instruments Multipoint RS485/RS422 Transceivers 8-SOIC 0 to 70 visit Texas Instruments Buy
DS3695AM Texas Instruments Multipoint RS485/RS422 Transceivers 8-SOIC 0 to 70 visit Texas Instruments
DS3695ATMX Texas Instruments Multipoint RS485/RS422 Transceivers 8-SOIC -40 to 85 visit Texas Instruments
DS3695ATM/NOPB Texas Instruments Multipoint RS485/RS422 Transceivers 8-SOIC -40 to 85 visit Texas Instruments

RJ12 to RS485

Catalog Datasheet MFG & Type PDF Document Tags

delta dvp HMI rs485 connection

Abstract: RJ12 to RS485 ) Introduction RJ12 ADP485-01 is mainly designed to connect Delta product by RS-485 interface. It is equipped , 68-2-6 (TEST Fc)/IEC 61131-2 & IEC 68-2-27 (TEST Ea) COM1, COM2, and RJ12 PIN Explanation RS-485 , RJ12 ( : 6 7 8 9 RS-485 ADP485-01 (120 ) RS-485 Definition 1 +15V 2 , Terminating Resistance 5 6 DIN 7 RS-485 8 RJ12 ) VFD GND RS-485 ASD-A ASD-B /30 , 60 6 Definition 3 PIN RS485- Definition 3, 6 8 connect to
-
Original
ADPCAB03A delta dvp HMI rs485 connection RJ12 to RS485 Serial DB9 to RJ12 delta plc servo sg 90 RJ12 db9 RJ12-VFD RS485- ADPCAB03B RJ12-ADP485-01 RS-485-

RJ12 connector

Abstract: RJ12 to RS485 Adapter DRRJ45T8 RJ-45 Parallel Connector DRRJ DRRJ45P6 CBJ11BD5 RJ-12 to RJ-12 1' Cable CBLRLC01 RJ-12 to RJ-12 10' Cable CBLRLC02 RJ-45 to RJ-45 1' Cable CBLRLC03 RJ-45 to RJ , Examples: DLC, IAMS, ITMS, and PAX. A Red Lion Controls device with an RS485 RJ-11 port is connected to the DRRJ11T6 adapter using the CBJ11BD5 cable. The terminal block is then wired to run the RS485 MODBUS serial information to another device. RJ-11 DIMENSIONS In inches (mm) RS232 via RJ-12
Red Lion Controls
Original
RJ12 connector LP0554 RJ-11/12 CBLRLC04 CBLRLC07

rj12 rs485

Abstract: 10 HP CAPACITOR START SINGLE PHASE motor WIRING DIAGRAM -2 D2-260 CPU GS1 RJ12 RS-485 Modbus RTU CLICK PLCs DL05 PLCs RJ12 to HD15 RJ12 to RJ12 , -2 D2-260 CPU RS-485 Modbus RTU DL06 PLCs RJ12 to HD15 RJ12 to RJ12 RJ12 to 5-pin plug Port , -485HD15-CBL â'" ZIPLink RS485 #7; communication cable for connection to the DL06 and D2-260 15-pin ports â'¢ USB-485M â'" USB to RS-485 PC adapter #7; (see â'Communications Productsâ' chapter for detailed , ), 0 to 20 mA; Multi-Speed Inputs 1 to 4, RS-232C/RS-485 communication interface Setting by
Automation Direct
Original
rj12 rs485 10 HP CAPACITOR START SINGLE PHASE motor WIRING DIAGRAM edr40 230VC SJ100-022NFU SJ100-037LFU SJ100-075LFU GS3-2010 GS2-41P0

RJ12 to RS232

Abstract: RJ12 to RS485 current and one phase to neutral voltage measurement. Outputs S1: S2: RS485 port RS232 port , management of communication from a single instrument to PC (RS232); By means of RS232 serial port, RS485 , and power supply. 2kVAC/DC between mesuring inputs and RS485/RS232/programming port (RJ12) 4kVAC , are subject to change without notice CPT-DINBDS190606 7 CPT-DIN RS485 Serial port , Specifications are subject to change without notice CPT-DINBDS190606 CPT-DIN Outputs connections RS485
Carlo Gavazzi
Original
RJ12 to RS232 IEC-60688 Wiring Diagram rj12 CPT-DIN RJ12 female connector CPT-DIN Basic Version 260VAC/DC 60VAC/DC RS422/485

RJ12 to RS232

Abstract: Wiring Diagram rj12 Range code System Power supply Outputs Option ing, with up to 3 analogue outputs, or RS485 , -analogue outputs: 0 to 10V DC RS485/RS422 port RS232 port Dupline bus Neutral current Phase-phase voltage , , energies, dmd By means of RS232 serial port, RS485 serial port or RS232 configuration port (RJ12 , @ I 3mA between measuring inputs and RS485/RS232/ programming port (RJ12) Dielectric strength , degree Weight 4kVAC RMS between power supply and RS485/RS232/programming port (RJ12) 4kVACRMS
Carlo Gavazzi
Original
EN62053-21 EN62053-31 Dupline CPT-DIN Advanced Version EN62053-31 pulse EN6205 RS422/485/RS232 EN62053-23 10VDC CPT-DINADS110706

CPT-DIN

Abstract: -analogue outputs: 0/4 to 20mA DC 1-analogue output: 0 to 10V DC 3-analogue outputs: 0 to 10V DC RS485/RS422 , (RS485) (@ C ±5° R.H. ≤60%) 25° C, Range accuracy: 0.02In to 0.05In Current System type: 3 , Relay outputs Purpose Type Insulation RS422/RS485 Connections Addresses Protocol From 0 to , port, RS485 serial port or RS232 configuration port (RJ12) Softw a re functions System selection , / programming port (RJ12) 4kVAC RMS between power supply and RS485/RS232/programming port (RJ12
-
Original
Abstract: -232 communications, RJ11 termination -S4 DP40-S4 110 Isolated RS-485 communications, RJ12 termination , -9SC4 30 RS-485 9 D pin converter from RJ12 phone jack DP40-25SC4 30 RS-485 25 D pin converter from , a 5 point scalable meter. The 5 point scalable option lends itself to varying cross sections on , III and IIIL/Up to 10,000 Divisions ß 5 Point Linearization ß Scales in Any Engineering Unit lb , divisions max Operating Temperature: 0 to 50°C (32 to 122°F) Storage Temperature: -40 to 85°C (-40 to Omega Engineering
Original
DP41-W DP41-W-GN DP40-A DP40-B DP40-R DP40-S2

iDRN-PS-1000

Abstract: RJ12 connector DRX series DB9-RJ12 30 DB9 to RJ12 Connector Adapter, includes 7ft. RJ12 cord DB25-RJ12 30 DB25 to RJ12 Connector Adapter, includes 7ft. RJ12 cord RJ12T 15 RJ12â'Tâ' Split Connector for RS-485 instruments, includes 7 ft. RJ12 cord 150 $ iDRN-PS-1000 DIN RAIL MOUNT (35mm) THERMOCOUPLE , -1000 Switching Supply Powers up to 7 Units Model No. iDRN-PS-1000 Price Description 150 Power Supply (switching), 95 to 240 Vac input, 24 Vdc output @ 850 mA (power 7 units) SOFTWARE OPC-SERVER 295 OPC
Newport Electronics
Original
iDRN-PS-1000 DRN-PS-1000 DRX-RS485-SW 95/98/NT/XP DRN-RS232-SW 95/98/NT CAT-285

RJ11 diagram

Abstract: RJ11 female socket ) RJ-45 (8P8C) RJ-45 (8P8C) RS-232 DSub 25 Receptacle to RS-485/RS-422 4-Pin Terminal Block/RJ , way Male to male 15 way Pin to Pin 25 way 37 way G517 97005 G517 97006 G517 97007 G517 , Durability 75 cycles Colour Suffix may be added to Part Number. This Suffix is for Internal use , Female to female Pin to Pin G517 97009 G517 97010 G517 97011 G517 97012 Current Voltage Male to female Pin to Pin G517 97013 G517 97014 G517 97015 G517 97016 G517 97017 G517 97018
Amphenol
Original
RJ11 diagram RJ11 female socket G517/527 RS-485/RS-422 DSUB-G51797010-25

RJ12 to RS485

Abstract: RS-485 repeaters, up to 254 modules may be connected to a single RS-485 port. The iDRX Series digital conditioners may be connected to an RS-485 bus using either screw terminator or RJ-12 connector , Input Ranges: 0 to 400 mV to 0 to 400 Vac full scale Interface:RS-485; RJ-12 or screw terminal , module provides an RS-485 Serial output that can be transmitted directly to computers and other devices with serial communications capability, or converted to Ethernet. On an RS-485 bus, up to 32
Omega Engineering
Original
C-12B
Abstract: characteristics like R422/RS485 port RS2 3 2 Configura tion Bus Connections Baud-rate Data format RJ12 , communication from a single instrument to PC (RS232); By means of RS232 serial port, RS485 serial port or , /programming port (RJ12) 4kVAC RMS between power supply and RS485/RS232/programming port. 4kVACRMS (for 1 , subject to change without notice CPT-DINBDS080610 CPT-DIN Outputs connections RS485 TX- RX , waves (voltages/currents) â'¢ Power supply: 90 to 260VAC/DC and 18 to 60VAC/DC â'¢ Protection degree -
Original

RJ10 to RS232

Abstract: 4925 B -2008R Description Connector RS-232 to RS-422/RS485 9F/10P RS232-422/485 D B 2 5 / D B 2 5 RS232-422/485 D , 2CC 15M S C T O SC Length 3M 15M 10M ( )+ / EthernetTransceivers 10B-T AUI to , -1008 2929 MCV-220Q09 RS232/RS422 2 3 3 1 SW-MCV850-Q09 RS232/RS485 5315 RS232/HM485 RS232/485 , -210C 4820 5835 9841 2764 18060 HT-500 HT-568R HT-314B K 111-01 HT-200R 8P8C/RJ-45,6P6C/RJ-12,6P4C/RJ-11 8P8C/RJ-45,6P6C/RJ-12,6P4C/RJ-11 110/88-TYPE UPT(RJ45) Professional Modular Crimps
Centenary Materials Catalog
Original
RJ10 to RS232 4925 B RJ10 to RS485 RJ45 CAT-6 AMP HT-2008R amp rj45 JTB000-01 54V003MCC2-01 54V015MCC2-01 JT1000-02 RID45-234 RID45-5678
Abstract: : 0 to 400 mV to 0 to 400 Vac full scale Interface: RS-485; RJ-12 or screw terminal connector , connected to a single RS-485 port stretching up to 4,000 ft., more with RS-485 repeaters. ETHERNET CONNECTION The Optional EIS-2 iServer module can connect up to thirty-two (32) iDRX RS-485 Signal , duplex) RS-485 (NEWPORT® Serial Protocol and MODBUS Serial Protocol) iDRN Output: 0 to 10 V@10 mA max , $ Software Selectable Input Ranges iDRX-ACV: 0 to 400 mV to 0 to 400 Vac iDRX-ACC: 0 to 10 mA Newport Electronics
Original

iLD24-FP

Abstract: Displays ) Approvals: CE per EN50081-1, EN50082-2, EN61010-1 Multi-Point Address (RS-485): 0 to 199 Flow Control , Device with RS-485 Pin Function -Tx/-Rx +Tx/+Rx COM Remote Display RJ-12 4 3 Screw Terminal , Remote Display RJ-12 Screw Terminal 4 (Tx) 3 (Tx) 3 (Rx) 2 (Rx) 5 1 2. Wiring RS-485 Interface. The RS-485 standard (multipoint) allows a computer, one or more devices and Big Displays (up to 32 , ) Press d to request â'Processâ' Value. a) RS-232 Mode, will send: *X01 b) RS-485 Mode, will send
Newport Electronics
Original
iLD24-FP Displays

iLD46-FP

Abstract: Displays , 7E1- 7 bit,even, 1 stop bit 8N1 â'" 8 bit, No parity, 1 stop bit Multi-Point Address (RS-485): 0 to , Device with RS-485 Pin Function -Tx/-Rx +Tx/+Rx COM Remote Display RJ-12 4 3 Screw Terminal , ) Press d to request â'Processâ' Value. a) RS-232 Mode, will send: *X01 b) RS-485 Mode, will send , Stop Bit 8N1 8 Bit, No parity, 1 Stop Bit COMM Communication Standard 232 RS-232 Standard 485 RS-485 , . 3. When used in RS-485 Mode, the device must be accessed with an appropriate Address Value. 4
Newport Electronics
Original
iLD46-FP
Abstract: 8N1 â'" 8 bit, No parity, 1 stop bit Multi-point Address (RS485): 0 to 199 Flow Control: No Flow , Remote Display RJ-12 4 3 Screw Terminal 3 2 1 4. Write alphanumeric characters to the Big , Bit, No parity, 1 Stop Bit COMM Communication Standard 232 RS-232 Standard 485 RS-485 Standard , Serial Bus. 3. When used in RS-485 Mode, the device must be accessed with an appropriate Address Value. 4. Latched Mode: Alarm remains latched until reset. To reset already latched alarm select any menu Newport Electronics
Original
Abstract: parity, 1 stop bit Multi-point Address (RS485): 0 to 199 Panel Cutout: 414.3 L x 179.4 W mm , to request â'Processâ' Value. a) RS-232 Mode, will send: *X01 b) RS-485 Mode, will send: *01X01 Device with RS-485 Pin Function -Tx/-Rx +Tx/+Rx COM Remote Display RJ-12 4 3 Screw Terminal , 232 RS-232 Standard 485 RS-485 Standard AddR Device Address 0000. Address Value .0099 INtF , continuously into the Serial Bus. 3. When used in RS-485 Mode, the device must be accessed with an Newport Electronics
Original
Abstract: 8N1 â'" 8 bit, No parity, 1 stop bit Multi-point Address (RS485): 0 to 199 Flow Control: No Flow , to request â'Processâ' Value. a) RS-232 Mode, will send: *X01 b) RS-485 Mode, will send: *01X01 Device with RS-485 Pin Function -Tx/-Rx +Tx/+Rx COM Remote Display RJ-12 4 3 Screw Terminal , Bit, No parity, 1 Stop Bit COMM Communication Standard 232 RS-232 Standard 485 RS-485 Standard , Serial Bus. 3. When used in RS-485 Mode, the device must be accessed with an appropriate Address Value Newport Electronics
Original
Abstract: Multi-point Address (RS485): 0 to 199 Panel Cutout: 414.3 L x 179.4 W mm (16.31â' L x 7.06â' W , Remote Display RJ-12 4 3 Screw Terminal 3 2 1 4. Write alphanumeric characters to the Big , ) In the examples for RS-485 it is assumed that the device address is 01. â'¢ (DOWN) RJ12 , 232 RS-232 Standard 485 RS-485 Standard AddR Device Address 0000. Address Value .0099 INtF , continuously into the Serial Bus. 3. When used in RS-485 Mode, the device must be accessed with an Newport Electronics
Original

iLD44-FP

Abstract: Displays , 7E1- 7 bit,even, 1 stop bit 8N1 â'" 8 bit, No parity, 1 stop bit Multi-Point Address (RS-485): 0 to , Device with RS-485 Pin Function -Tx/-Rx +Tx/+Rx COM Remote Display RJ-12 4 3 Screw Terminal , ) Press d to request â'Processâ' Value. a) RS-232 Mode, will send: *X01 b) RS-485 Mode, will send , Stop Bit 8N1 8 Bit, No parity, 1 Stop Bit COMM Communication Standard 232 RS-232 Standard 485 RS-485 , . 3. When used in RS-485 Mode, the device must be accessed with an appropriate Address Value. 4
Newport Electronics
Original
iLD44-FP
Showing first 20 results.